Control panel message Description Recommended action 2219-USB Key Provisioning file has invalid header identifier Provisioning file contained on the USB key 1. Recreate the provisioning file using has been corrupted or is not a valid version third party management console for the current ME firmware. software. 2. If the error persists and system BIOS has been recently updated, restore previous system BIOS version. Otherwise, update the ME firmware version. 3. If the error still persists, replace the system board. 2220-USB Key Provisioning file has mismatch version Provisioning file contained on the USB key is not a valid version for the current ME firmware. 1. Reboot the computer. 2. If the error persists and system BIOS has been recently updated, restore previous system BIOS version. Otherwise, update the ME firmware version. 3. If the error still persists, replace the system board. 2230-General error during MEBx execution Error occurred during MEBx execution which fails into the "General" grouping. Status information displayed along with the error provides further clarity into the failure. MEBx handles transference of information between the system BIOS and ME firmware. 1. Reboot the computer. 2. If the error persists, update to the latest BIOS version and ME firmware version. 3. If the error still persists, replace the system board. 2231-ME error during MEBx execution Error occurred during MEBx execution which fails into "ME" grouping. 1. Reboot the computer. 2. If the error persists, update to the latest BIOS version and ME firmware version. 3. If the error still persists, replace the system board. 2232-AMT error during MEBx execution Error occurred during MEBx execution which fails into "AMT" grouping. 1. Reboot the computer. 2. If the error persists, update to the latest BIOS version and ME firmware version. 3. If the error still persists, replace the system board. 2233-HECI error during MEBx execution Error occurred during MEBx execution which fails into "MEI or HECI" grouping. 1. Reboot the computer. 2. If the error persists, update to the latest BIOS version and ME firmware version. 3. If the error still persists, replace the system board. Invalid Electronic Serial Number Electronic serial number is missing. Enter the correct serial number in Computer Setup. 132 Appendix D POST Error Messages