HP 3000 HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 4.1A f - Page 11

Operating constraints, HP StorageWorks Storage System Scripting Utility, Avoiding problem situations

Page 11 highlights

Under storage, click Storage Networking, and then select HP StorageWorks SAN under HP StorageWorks SAN Solutions. NOTE: HP recommends that you not mix switch firmware versions in your SAN. It is a best practice to uniformly upgrade all switches in the SAN. Server support Windows supports the following servers: • AMD® Opteron-based ProLiant servers • Intel-based ProLiant X86 and ProLiant Blade servers • HP Integrity servers • Fujitsu PrimeQuest Itanium Servers Operating constraints You can find information about operating constraints specific to the EVA firmware and HP StorageWorks Command View EVA in their respective release notes. SAN boot procedures Booting from the SAN is supported for Windows 2000 and Windows 2003 for multipath configurations. SAN boot procedures are available on the HP StorageWorks website: http://h18004.www1.hp.com/products/storageworks/san/documentation.html HP StorageWorks Storage System Scripting Utility The latest version of the Storage System Scripting Utility (SSSU) is available on the software downloads HP website: http://www.hp.com/support/downloads Under storage, click Storage Software, and then select HP StorageWorks Command View EVA under Storage Device Management Software. Select the version of the HP StorageWorks Command View EVA. Avoiding problem situations This section describes problems that may arise and their solutions. SSSU Changing comments on a disk enclosure Use HP Command View EVA to change comments on a disk enclosure. If you try to change a disk enclosure comment using SSSU, the following error message appears: Error: Invalid Operation Changing the name of a disk enclosure Changing the name of a disk enclosure is not supported with SSSU or HP Command View EVA. If you try to change a disk enclosure name using SSSU, the following error message appears: HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 4.1A for Windows release notes 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13

Under
storage
, click
Storage Networking
, and then select
HP StorageWorks SAN
under
HP StorageWorks
SAN Solutions
.
NOTE:
HP recommends that you
not
mix switch
rmware versions in your SAN. It is a best practice to uniformly
upgrade all switches in the SAN.
Server support
Windows supports the following servers:
AMD® Opteron-based ProLiant servers
Intel-based ProLiant X86 and ProLiant Blade servers
HP Integrity servers
Fujitsu PrimeQuest Itanium Servers
Operating constraints
You can
nd information about operating constraints speci
c to the EVA
rmware and HP StorageWorks
Command View EVA in their respective release notes.
SAN boot procedures
Booting from the SAN is supported for Windows 2000 and Windows 2003 for multipath con
gurations.
SAN boot procedures are available on the HP StorageWorks website:
h
t
t
p
:
/
/
h
1
8
0
0
4
.
w
w
w
1
.
h
p
.
c
o
m
/
p
r
o
d
u
c
t
s
/
s
t
o
r
a
g
e
w
o
r
k
s
/
s
a
n
/
d
o
c
u
m
e
n
t
a
t
i
o
n
.
h
t
m
l
HP StorageWorks Storage System Scripting Utility
The latest version of the Storage System Scripting Utility (SSSU) is available on the software downloads
HP website:
h
t
t
p
:
/
/
w
w
w
.
h
p
.
c
o
m
/
s
u
p
p
o
r
t
/
d
o
w
n
l
o
a
d
s
Under
storage
, click
Storage Software
, and then select
HP StorageWorks Command View EVA
under
Storage Device Management Software
. Select the version of the HP StorageWorks Command View EVA.
Avoiding problem situations
This section describes problems that may arise and their solutions.
SSSU
Changing comments on a disk enclosure
Use HP Command View EVA to change comments on a disk enclosure. If you try to change a disk
enclosure comment using SSSU, the following error message appears:
Error:
Invalid Operation
Changing the name of a disk enclosure
Changing the name of a disk enclosure is not supported with SSSU or HP Command View EVA. If you try
to change a disk enclosure name using SSSU, the following error message appears:
HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 4.1A for Windows release notes
11