HP 3PAR StoreServ 7450 4-node HP 3PAR CIM API Programming Reference (OS 3.1.2 - Page 213
of LUNames. LUNames, DeviceNumbers and DeviceAccesses MUST
View all HP 3PAR StoreServ 7450 4-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 213 highlights
"or tape drives) through a 'default view' " "SCSIProtocolController (SPC) through a list of target " "ports. The 'default view' SPC exposes logical units to all " "initiators. This SPC is identified by an association to a " "StorageHardwareID with Name property set to the empty " "string. \n" "\n" "The parameters for this method are: Job - null if no job " "created, otherwise this is a reference to the job. LUNames " "- the list of names of the logical units to use. " "TargetPortIDs - the names of the target ports to use. " "DeviceNumbers - the device numbers (LUNs) to use. " "DeviceAccesses - permissions for the logical units. " "ProtocolControllers - SPCs involved in this operation. \n" "\n" "There are two modes of operation, create and modify. If a " "NULL value is passed in for the SPC, then the " "instrumentation will attempt to create a new default view. " "There could be multiple default view SPCs associated with " "each port. If an SPC is passed in, then the " "instrumentation adds the new paths to the existing SPC. \n" "\n" "For creating a default view SPC, all parameters, except " "ProtocolControllers, MUST be specified since SPCAllowsNoLUs, " "SPCAllowsNoTargets and SPCAllowsNoInitiators properties are " "all false, and ClientSelectableDeviceNumbers property is " "true, for a HP 3PAR Storage System. \n" "\n" "The LUNames, DeviceNumbers, and DeviceAccesses parameters " "are mutually indexed arrays - any element in DeviceNumbers " "or DeviceAccesses will set a property relative to the " "LogicalDevice instance named in the corresponding element " "of LUNames. LUNames, DeviceNumbers and DeviceAccesses MUST " "have the same number of elements. If these conditions are " "not met, the instrumentation MUST return a 'Invalid Parameter' " "status or a CIM_Error. \n" "\n" "For modifying an SPC, the HP 3PAR Storage System supports only " "the Add LUs to a view use case." "Add LUs to a view requires that the LUNames and DeviceNumbers " "parameters not be null and that the InitiatorIDs and TargetPortIDs " "parameters be null. \n" "\n" "The relevant rules of SCSI semantics are: \n" "- an SPC MAY NOT be exposed through a particular " "host/target port pair that is in use by another SPC. (In " "other words, an SPC and its associated logical units and " "ports together correspond to the logical unit inventory " "provided by SCSI REPORT LUNS and INQUIRY commands) \n" "- each LogicalDevice associated to an SPC MUST have a " "unique ProtocolControllerForUnit DeviceNumber (logical unit " "number) \n" "The instrumentation MUST report an error if the client " "request would violate one of these rules. \n" "\n" "If the instrumentation provides PrivilegeManagementService, " "the results of setting DeviceAccesses MUST be synchronized " "with PrivilegeManagementService as described in the " "ProtocolControllerForUnit DeviceAccess description."), ValueMap { "0", "1", "2", "3", "4", "5", "6..4095", "4096", "4097", "4098", "4099", "4100", "4101", "4102..32767", "32768..65535" }, Values { "Success", "Not Supported", "Unspecified Error", "Timeout", "Failed", "Invalid Parameter", "DMTF Reserved", "Method Parameters Checked - Job Started", "Invalid logical unit ID", "Invalid target port ID", "Invalid permission", "Requested logical unit number in use", 3PAR_TPD.mof 213