HP 4000/6000/8000 HP StorageWorks 4000/6000/8000 Enterprise Virtual Array Conn - Page 4

Switch support, Failover/failback, FCA support, AlphaServer support, Table 2 FCA support

Page 4 highlights

Switch support This release supports the Fibre Channel (FC) switches and firmware versions listed in the HP StorageWorks SAN design reference guide, which you can download from the HP StorageWorks web site: http://h18004.www1.hp.com/products/storageworks/san/documentation.html NOTE: HP recommends that you not mix switch firmware versions in a SAN. It is a best practice to uniformly upgrade all switches in the SAN. Failover/failback Failback preference settings for the HSV controllers are specific to the operating system. For operating system failback information, see the HP StorageWorks 4000/6000/8000 Enterprise Virtual Array user guide. FCA support Table 2 lists the supported FCAs and the required firmware versions. Table 2 FCA support Adapter firmware FCA Driver (minimum) HP StorageWorks FCA2354 2 Gb, 64-bit/66MHz PCI PN DS-KGPSA-DA HP StorageWorks FCA2384 2 Gb, 64-bit/133MHz PCI-X PN DS-KGPSA-EA Native 3.93a0 Native 1.91x6 HP StorageWorks FCA2684 2 Gb, 64-bit/133MHz PCI-X PN DS-A5132-AA HP StorageWorks FCA2684DC 2 Gb, 64-bit/133MHz PCI-X Dual PN DS-A5134-AA Native 1.91x6 Native 1.91x6 HP StorageWorks A6826A 2 Gb, 64-bit/133MHz PCI-X Dual (supported only on Integrity servers) Native n/a (loaded by the driver) HP StorageWorks A9782A PCI-X 2 Gb FC, and 1 Gb Ethernet (supported only on Integrity servers) Native n/a (loaded by the driver) HP StorageWorks A9784A PCI-X 2 Gb FC, and 1 Gb Ethernet (supported only on Integrity servers) Native n/a (loaded by the driver) AlphaServer support Table 3 lists the EVA-compatible AlphaServers. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

Switch support
This release supports the Fibre Channel (FC) switches and firmware versions listed in the
HP StorageWorks
SAN design reference guide
, which you can download from the HP StorageWorks web site:
h
t
t
p
:
/
/
h
1
8
0
0
4
.
w
w
w
1
.
h
p
.
c
o
m
/
p
r
o
d
u
c
t
s
/
s
t
o
r
a
g
e
w
o
r
k
s
/
s
a
n
/
d
o
c
u
m
e
n
t
a
t
i
o
n
.
h
t
m
l
NOTE:
HP recommends that you
not
mix switch firmware versions in a SAN. It is a best practice to uniformly
upgrade all switches in the SAN.
Failover/failback
Failback preference settings for the HSV controllers are specific to the operating system. For operating
system failback information, see the
HP StorageWorks 4000/6000/8000 Enterprise Virtual Array
user guide.
FCA support
Table 2
lists the supported FCAs and the required firmware versions.
Table 2 FCA support
FCA
Driver
Adapter
firmware
(minimum)
HP StorageWorks FCA2354
2 Gb, 64-bit/66MHz PCI
PN DS-KGPSA-DA
Native
3.93a0
HP StorageWorks FCA2384
2 Gb, 64-bit/133MHz PCI-X
PN DS-KGPSA-EA
Native
1.91x6
HP StorageWorks FCA2684
2 Gb, 64-bit/133MHz PCI-X
PN DS-A5132-AA
Native
1.91x6
HP StorageWorks FCA2684DC
2 Gb, 64-bit/133MHz PCI-X Dual
PN DS-A5134-AA
Native
1.91x6
HP StorageWorks A6826A
2 Gb, 64-bit/133MHz PCI-X Dual
(supported only on Integrity servers)
Native
n/a
(loaded by the
driver)
HP StorageWorks A9782A
PCI-X 2 Gb FC, and 1 Gb Ethernet
(supported only on Integrity servers)
Native
n/a
(loaded by the
driver)
HP StorageWorks A9784A
PCI-X 2 Gb FC, and 1 Gb Ethernet
(supported only on Integrity servers)
Native
n/a
(loaded by the
driver)
AlphaServer support