HP 8/24 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01, July 2009) - Page 137
BL-1023, BL-1024, BL-1025, BL-1026
View all HP 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 137 highlights
BL-1023 7 Severity CRITICAL BL-1023 Message , [BL-1023], ,, CRITICAL, , Blade in slot was reset before blade init completed. As a result the blade is faulted. Probable Cause Indicates that the blade was reset before the initialization completed. Recommended Action Restart or power cycle the blade. If the message persists, replace the blade. Severity CRITICAL BL-1024 Message , [BL-1024], ,, INFO, , All ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all datapath elements were reset. Recommended No action is required. Action Severity INFO BL-1025 Message , [BL-1025], ,, INFO, , All GigE/FCIP Virtualization ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all GbE or Fibre Channel over IP (FCIP) or Virtualization data elements or FC Fastwrite ports were reset. Recommended No action is required. Action Severity INFO BL-1026 Message , [BL-1026], ,, CRITICAL, , Internal port offline during warm recovery, state (0x). Fabric OS Message Reference 67 53-1001338-01