HP 8/8 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 401
KSWD System Messages, KSWD-1001
View all HP 8/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 401 highlights
Chapter KSWD System Messages 50 KSWD-1001 Message , [KSWD-1001], , FFDC, WARNING, , : failed to refresh (:). Probable Cause Indicates one of the critical daemons is found to be nonresponsive. An abort signal is sent. Recommended Copy the warning message along with any core file information, and contact your switch service Action provider. Severity WARNING KSWD-1002 Message , [KSWD-1002], , FFDC, WARNING, , Detected termination of process :. Probable Cause Indicates a process on the switch has ended unexpectedly. Recommended Copy the warning message along with any core file information, and contact your switch service Action provider. Severity WARNING KSWD-1003 Message Probable Cause , [KSWD-1003], , FFDC, WARNING, , kSWD: . Indicates a warning state within the system. A critical application error was reported in the watchdog subsystem. Refer to the string at the end of the error message for specific information. The switch will reboot (on single-CP switches) or fail over (on dual-CP switches). The warning message will be one of the following: • Probable Cause: One of the critical daemons ended unexpectedly. • Probable Cause: One of the critical daemons is found to be nonresponsive; sending signal abort. Fabric OS Message Reference 343 53-1001157-01