HP 8/80 Brocade Troubleshooting and Diagnostics Guide v6.1.0 (53-1000853-01, J - Page 42
command on the secondary port after, primary port goes offline.
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
3 Device login issues switch:admin> porterrshow frames enc crc too too bad enc disc link loss loss frjt fbsy tx rx in err shrt long eof out c3 fail sync sig 0: 39m 95m 0 0 0 0 0 364k 10 13 6.1k 8 0 0 1: 2.6g 4.1g 0 0 0 0 0 150k 46 0 0 1 0 0 2: 3.7g 2.0g 0 0 0 0 0 18 134 0 0 0 0 0 3: 2.2g 2.9g 0 0 0 0 0 19 127 0 0 0 0 0 4: 20m 19m 0 0 0 0 0 241k 10 10 4.3k 5 0 0 5: 113m 2.4g 0 0 0 0 0 96k 12 0 0 1 0 0 6: 331m 359m 0 0 0 0 0 249m 1.4k 1 2.3k 2 0 0 7: 156m 171m 0 0 0 0 0 10m 1.4k 27 52 6 0 0 8: 3.0g 1.1g 5 2 0 0 0 117k 1 38 62 28 0 0 9: 2.0g 807m 0 0 0 0 0 12k 0 10 19 2 0 0 10: 0 0 0 0 0 0 0 139k 0 0 0 1 0 0 11: 0 0 0 0 0 0 0 129k 0 0 0 1 0 0 12: 1.7g 3.1g 0 0 0 0 0 426 1.4k 0 0 0 0 0 13: 697m 691m 0 0 0 0 0 6.0k 1.4k 0 0 0 0 0 14: 2.3g 1.7g 0 0 0 0 0 107 1.0k 0 0 0 0 0 15: 3.1g 893m 0 0 0 0 0 58 37k 0 0 0 0 0 NOTE When two shared ports on an FC4-48 blade are receiving traffic and the primary port goes offline, all the frames that are out for delivery for the primary port are dropped, but the counters show them as dropped on the secondary port that shares the same area. Error counters increment unexpectedly for the secondary port, but the secondary port is operating properly. If this occurs, clear the counters using the portStatsClear command on the secondary port after primary port goes offline. 5. Enter the portFlagsShow command; then, check to see how a port has logged in and where a login failed (if a failure occurred): switch:admin> portflagsshow Port SNMP Physical Flags 0 Offline In_Sync PRESENT U_PORT LED 1 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN NOELP LED ACCEPT 2 Offline No_Light PRESENT U_PORT LED 3 Offline No_Module PRESENT U_PORT LED 4 Offline No_Module PRESENT U_PORT LED 5 Offline No_Light PRESENT U_PORT LED 6 Offline No_Module PRESENT U_PORT LED 7 Offline No_Module PRESENT U_PORT LED 8 Offline No_Light PRESENT U_PORT LED 9 Offline No_Light PRESENT U_PORT LED 10 Offline No_Module PRESENT U_PORT LED 11 Offline No_Module PRESENT U_PORT LED 12 Offline No_Module PRESENT U_PORT LED 13 Offline No_Module PRESENT U_PORT LED 14 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN NOELP LED ACCEPT 15 Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED LOGIN LED 28 Fabric OS Troubleshooting and Diagnostics Guide 53-1000853-01