HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Enterpris - Page 15

MMA STARTED, if [ -f $PCSC_LIB ]; then, PCSC_LIB, MMA STOP, supportsave, types[active and inactive

Page 15 highlights

Closed defect summary Solution Exporting aliases not converting {D,P} member into WWN as specified in the FS. Symptom-When the user export the alias with {D,P} member, the {D,P} member appears as it was in the Zoning dialog and no conversion to the switch port WWN occurs as specified in the FS. Fixed in DCFM 10.1.0 Workaround-change {D,P} entries to the corresponding switch port WWN manually in the exported CSV file. Need to include runtime library config for pcsc in DCFM script. Fixed in DCFM 10.1.0 Workaround-In order for smartcard to work, the customer must edit the DCFM script to include: # MMA STARTED PCSC_LIB=/opt/pcsc/lib/libpcsclite.so if [ -f $PCSC_LIB ]; then JAVA_OPTS="$JAVA_OPTS -Dsun.security.smartcardio.library= $PCSC_LIB" fi # MMA STOP Server supportsave does not capture the client logs when the client is launched through browser from the same machine. Symptom-When the DCFM client is launched through the browser from the same machine, the server support save fails to capture the client logs. Fixed in DCFM 10.1.0 Wave Length column in port optics dialog is currently blank. Symptom-User does not view any value for the Wave Length column in port optics dialog. Fixed in DCFM 10.1.0 Port selection button does not get enabled for inactive FCIP tunnel in performance port picker Symptom-Suppose a tunnel is present which was active some time back and later becomes inactive then the user will not be able generate graph for inactive tunnel as the port selector is disabled for inactive FCIP tunnels in the performance port picker. Fixed in DCFM 10.1.0 Workaround-If the user wants to generate the graph for all the types[active and inactive tunnels], the user will have to select FCIP from the historical wizard from the "From" drop-down list and then generate a graph. But for real time the user cannot select in active tunnels. Zoning report showing zone name twice when zone is part of active zone config. Symptom-When user generates report with active zone config, the active zone appears twice in the Report with Active=Yes and Active=No values. Fixed in DCFM 10.1.0 DCFM Professional, disable backup, nl migrate to enterprise, open options-backup, close, invalid error message. Symptom-A confusing error message when using the options dialog after migration. Even though the backup is disabled the path is invalid and must contain a valid path. Fixed in DCFM 10.1.0 Workaround-Enter a valid backup directory, even if backup is disabled. HP StorageWorks B-series Data Center Fabric Manager Enterprise 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

Solution
Closed defect summary
Fixed in DCFM 10.1.0
Workaround—change {D,P} entries to the
corresponding switch port WWN manually in the
exported
CSV
file.
Exporting aliases not converting {D,P} member into
WWN as specified in the FS.
Symptom—When the user export the alias with {D,P}
member, the {D,P} member appears as it was in the
Zoning dialog and no conversion to the switch port
WWN occurs as specified in the FS.
Fixed in DCFM 10.1.0
Workaround—In order for smartcard to work, the
customer must edit the DCFM script to include:
# MMA STARTED
PCSC_LIB=/opt/pcsc/lib/libpcsclite.so
if [ -f $PCSC_LIB ]; then
JAVA_OPTS="$JAVA_OPTS
-Dsun.security.smartcardio.library=
$PCSC_LIB"
fi
# MMA STOP
Need to include runtime library config for
pcsc
in
DCFM script.
Fixed in DCFM 10.1.0
Server
supportsave
does not capture the client
logs when the client is launched through browser from
the same machine.
Symptom—When the DCFM client is launched through
the browser from the same machine, the server
support save
fails to capture the client logs.
Fixed in DCFM 10.1.0
Wave Length column in port optics dialog is currently
blank.
Symptom—User does not view any value for the Wave
Length column in port optics dialog.
Fixed in DCFM 10.1.0
Workaround—If the user wants to generate the graph
for all the
types[active and inactive
tunnels],
the user will have to select FCIP from the
historical wizard from the "From" drop-down list and
then generate a graph. But for real time the user
cannot select in active tunnels.
Port selection button does not get enabled for inactive
FCIP tunnel in performance port picker
Symptom—Suppose a tunnel is present which was
active some time back and later becomes inactive then
the user will not be able generate graph for inactive
tunnel as the port selector is disabled for inactive FCIP
tunnels in the performance port picker.
Fixed in DCFM 10.1.0
Zoning report showing zone name twice when zone
is part of active zone config.
Symptom—When user generates report with active
zone config, the active zone appears twice in the
Report with
Active=Yes
and
Active=No
values.
Fixed in DCFM 10.1.0
Workaround—Enter a valid backup directory, even if
backup is disabled.
DCFM Professional, disable backup,
nl
migrate to enterprise, open options-backup, close, in-
valid error message.
Symptom—A confusing error message when using the
options dialog after migration. Even though the backup
is disabled the path is invalid and must contain a valid
path.
HP StorageWorks B-series Data Center Fabric Manager Enterprise
15