HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Enterpris - Page 15
MMA STARTED, if [ -f $PCSC_LIB ]; then, PCSC_LIB, MMA STOP, supportsave, types[active and inactive
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Closed defect summary Solution Exporting aliases not converting {D,P} member into WWN as specified in the FS. Symptom-When the user export the alias with {D,P} member, the {D,P} member appears as it was in the Zoning dialog and no conversion to the switch port WWN occurs as specified in the FS. Fixed in DCFM 10.1.0 Workaround-change {D,P} entries to the corresponding switch port WWN manually in the exported CSV file. Need to include runtime library config for pcsc in DCFM script. Fixed in DCFM 10.1.0 Workaround-In order for smartcard to work, the customer must edit the DCFM script to include: # MMA STARTED PCSC_LIB=/opt/pcsc/lib/libpcsclite.so if [ -f $PCSC_LIB ]; then JAVA_OPTS="$JAVA_OPTS -Dsun.security.smartcardio.library= $PCSC_LIB" fi # MMA STOP Server supportsave does not capture the client logs when the client is launched through browser from the same machine. Symptom-When the DCFM client is launched through the browser from the same machine, the server support save fails to capture the client logs. Fixed in DCFM 10.1.0 Wave Length column in port optics dialog is currently blank. Symptom-User does not view any value for the Wave Length column in port optics dialog. Fixed in DCFM 10.1.0 Port selection button does not get enabled for inactive FCIP tunnel in performance port picker Symptom-Suppose a tunnel is present which was active some time back and later becomes inactive then the user will not be able generate graph for inactive tunnel as the port selector is disabled for inactive FCIP tunnels in the performance port picker. Fixed in DCFM 10.1.0 Workaround-If the user wants to generate the graph for all the types[active and inactive tunnels], the user will have to select FCIP from the historical wizard from the "From" drop-down list and then generate a graph. But for real time the user cannot select in active tunnels. Zoning report showing zone name twice when zone is part of active zone config. Symptom-When user generates report with active zone config, the active zone appears twice in the Report with Active=Yes and Active=No values. Fixed in DCFM 10.1.0 DCFM Professional, disable backup, nl migrate to enterprise, open options-backup, close, invalid error message. Symptom-A confusing error message when using the options dialog after migration. Even though the backup is disabled the path is invalid and must contain a valid path. Fixed in DCFM 10.1.0 Workaround-Enter a valid backup directory, even if backup is disabled. HP StorageWorks B-series Data Center Fabric Manager Enterprise 15