HP Cisco MDS 9124 Cisco MDS 9124e Fabric Switch for HP c-Class BladeSystem Use - Page 54

Weight and physical dimensions, IEC 61000-4-3 Severity Level 3 for Radiated Fields

Page 54 highlights

Specification EMC immunity System architecture ANSI protocol Modes of operation Maximum frame size Port-to-port latency Description • IEC 61000-4-2 Severity Level 3 for Electrostatic Discharge • IEC 61000-4-3 Severity Level 3 for Radiated Fields • IEC 61000-4-4 Severity Level 3 for Fast Transients • IEC 61000-4-5 Severity Level 3 for Surge Voltage • IEC 61000-4-6 Conducted Emissions • IEC 61000-4-11 Voltage Variations • EN 61000-4-12 Oscillatory Waves Immunity • EN 61000-3-2 Limits for Harmonic Current Emissions • EN 61000-3-3 JEIDA Nonblocking shared-memory switch FC-PH (FC Physical and Signalling Interface standard) FC Class 2, Class 3, and Class F 2112-byte 1.2 ì sec. with no contention, cut-through routing at 4Gb. Latency increases as input port speed increases and becomes disparate from output port speed. Weight and physical dimensions Table 14 lists physical properties. Table 14 Switch physical dimensions Dimension Height Width Measurement 29.3 mm (1.15 in) 208 mm (8.19 in) Depth 280 mm (11.02 in) Weight 1.27 kg (2.8 lb) 54 Switch technical specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

Switch technical specifications
54
Weight and physical dimensions
Table 14
lists physical properties.
Table 14
Switch physical dimensions
EMC immunity
°
IEC 61000-4-2 Severity Level 3 for Electrostatic Discharge
°
IEC 61000-4-3 Severity Level 3 for Radiated Fields
°
IEC 61000-4-4 Severity Level 3 for Fast Transients
°
IEC 61000-4-5 Severity Level 3 for Surge Voltage
°
IEC 61000-4-6 Conducted Emissions
°
IEC 61000-4-11 Voltage Variations
°
EN 61000-4-12 Oscillatory Waves Immunity
°
EN 61000-3-2 Limits for Harmonic Current Emissions
°
EN 61000-3-3 JEIDA
System architecture
Nonblocking shared-memory switch
ANSI protocol
FC-PH (FC Physical and Signalling Interface standard)
Modes of operation
FC Class 2, Class 3, and Class F
Maximum frame size
2112-byte
Port-to-port latency
1.2 ¸ sec. with no contention, cut-through routing at 4Gb. Latency
increases as input port speed increases and becomes disparate from
output port speed.
Specification
Description
Dimension
Measurement
Height
29.3 mm (1.15 in)
Width
208 mm (8.19 in)
Depth
280 mm (11.02 in)
Weight
1.27 kg (2.8 lb)