HP Cisco MDS 9134 Cisco MDS 9500 Series Hardware Installation Guide (OL-17467-
HP Cisco MDS 9134 - Fabric Switch Manual
View all HP Cisco MDS 9134 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Cisco MDS 9134 manual content summary:
- HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 1
Send documentation comments to [email protected]. Cisco MDS 9500 Series Hardware Installation Guide October 2008 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 2
it is not installed in accordance with Cisco's installation instructions, it may cause interference with radio and television reception. This equipment has been tested and found to comply with the limits for a Class B digital device in accordance with the specifications in part 15 of the FCC rules - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 3
Fabric Manager xix Command-Line Interface xix Intelligent Storage Networking Services Configuration Guides xix Troubleshooting and Reference xix Installation and Configuration Note xix Obtaining Documentation, Obtaining Support, and Security Guidelines xx Product Overview 1-1 Chassis 1-2 Cisco MDS - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 4
Fibre Channel Advanced Services Modules 1-49 32-Port Fibre Channel Storage Services Module 1-50 LEDs on the Storage Services Modules 1-51 Caching Services Module 1-52 LEDs on the Caching Services Module 1-54 Supported Transceivers 1-55 Cisco MDS 9500 Series Hardware Installation Guide ii OL-17467 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 5
and Services Modules 2-45 Installing a Switching or Services Module, Including Caching Services Modules 2-45 Verifying Installation of Supervisor, Switching, and Services Modules 2-46 Removing and Installing a Crossbar Module 2-47 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide iii - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 6
Module from the Cisco MDS 9509 Director 2-80 Installing a Clock Module into the Cisco MDS 9509 Director 2-83 Removing a Clock Module from the Cisco MDS 9506 Director 2-83 Installing a Clock Module into the Cisco MDS 9506 Director 2-86 Cisco MDS 9500 Series Hardware Installation Guide iv OL-17467 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 7
the MDS 9513 Fabric 2 Modules and Activating Higher Bandwidth by Powering Down the Switch A-11 Migration Procedure for the MDS 9509 Director and MDS 9506 Director A-12 Connecting the Cisco MDS 9500 Series B-1 Preparing for Network Connections B-2 Connecting to the Console Port B-2 Connecting to - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 8
Shelf Bracket Kit into a Four-Post EIA Rack C-10 Installing the Switch on the Rack-Mount Support Brackets C-11 Installing the Switch on the Shelf Brackets C-12 Removing the Shelf Bracket Kit (Optional) C-12 Cisco MDS 9500 Shelf Bracket C-13 Rack-Mounting Guidelines C-14 Before Installing the Shelf - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 9
Environmental and Power Requirement Specifications for Cisco Gigabit Ethernet Transceivers D-34 Cisco DWDM SFP Transceivers D-34 E A P P E N D I X Cable and Port Specifications E-1 Cables and Adapters Provided E-1 Console Port E-2 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide vii - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 10
F A P P E N D I X Site Planning and Maintenance Records F-1 Contacting Customer Service F-1 Finding the Chassis Serial Number F-2 Site Preparation Checklist F-4 Contact and Site Information F-6 Chassis and Module Information F-7 Cisco MDS 9500 Series Hardware Installation Guide viii OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 11
Specifications" section on page D-1. 24-port 8-Gbps Fibre Channel switching module Added 24-port 8-Gbps Fibre Channel switching module. The switching module offers 24 autosensing 1-, 2-, 4and 8-Gbps Fibre Channel ports and can be used in the Cisco MDS 9500 Series Switches. 4.1(1b) The "24-port - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 12
on page 1-42 and the "Technical Specifications" section on page D-1. Cisco MDS 9513 Multilayer Director Added Cisco MDS 9513 Multilayer Director. The chassis consists of 13 horizontal slots, where slots 1 to 6 and slots 9 to 13 are reserved for switching, services, and IPS modules, and slots 7 and - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 13
any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9216i and 9216A Switches. 3.0(1) The "24-port 4-Gbps Fibre Channel Switching Module" section on page 1-35 and the "Technical Specifications" section on page D-1. 12-port 4-Gbps Fibre Channel switching module Added 12-port 4-Gbps Fibre - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 14
for the Cisco MDS 9509 Power Supplies" section on page D-9. Gigabit Ethernet SFP transceiver Added Gigabit Ethernet SFP transceiver. Not release specific The "Supported Transceivers" section on page 1-55 and the "SFP and SFP+ Transceiver Specifications" section on page D-22. 32-port Fibre - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 15
services and iSCSI services capability in an 8-port Gigabit Ethernet module. 1.1(1a) The "IP Storage Services Modules" section on page 1-46. Cisco MDS Added the Cisco MDS 9506 Director, a 1.1(1a) 9506 Director multilayer Fibre Channel switch that supports up to six modules. This guide. 16-port - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 16
New and Changed Information Send documentation comments to [email protected]. Cisco MDS 9500 Series Hardware Installation Guide xiv OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 17
a switch using the optional Telco and EIA Shelf Bracket Kit. Appendix D Technical Specifications Lists the Cisco MDS 9500 Series switch specifications, and includes safety information, site requirements, and power connections. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide xv - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 18
cisco.com. Chapter Title Appendix E Cable and Port Specifications Appendix F Site Planning and Maintenance Records Description Lists cable and port specifications for the Cisco MDS 9500 Series switch ja tietoa turvallisuudesta). Cisco MDS 9500 Series Hardware Installation Guide xvi OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 19
Preface Send documentation comments to [email protected]. Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans con las disposiciones reglamentarias) que se acompaña con este dispositivo. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide xvii - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 20
Storage Service Interface Images Regulatory Compliance and Safety Information • Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family Hardware Installation • Cisco MDS 9124 Multilayer Fabric Switch Quick Start Guide • Cisco MDS 9500 Series Hardware Installation Guide • Cisco MDS - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 21
MDS 9000 Family Fabric Manager Configuration Guide • Cisco MDS 9000 Family Fabric Manager Database Schema • Cisco MDS 9000 Family Data Mobility Manager Configuration Guide Command-Line Interface • Cisco MDS 9000 Family Software Upgrade and Downgrade Guide • Cisco MDS 9000 Family Storage Services - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 22
New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0. Cisco MDS 9500 Series Hardware Installation Guide xx OL - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 23
, see the Cisco MDS 9000 Family CLI Configuration Guide and the Cisco MDS 9000 Family Fabric Manager Configuration Guide. The Cisco MDS 9500 Series supports the following hot-swappable, field-replaceable modules: • 48-port 8-Gbps Fibre Channel switching module (DS-X9248-96K9) • 24-port 8-Gbps Fibre - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 24
page 1-27 • Port Index Availability, page 1-28 • Switching Modules, page 1-32 • Services Modules, page 1-41 • Supported Transceivers, page 1-55 Chassis This section describes the different chassis offerings in the Cisco MDS 9500 Series: • Cisco MDS 9513 Director, page 1-3 • Cisco MDS 9509 Director - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 25
exist on both sides of the plane. (See Figure 1-1.) The Cisco MDS 9513 Director supports the following: • Two Supervisor-2 modules that reside in slots 7 and 8. • Switching and storage services modules. (See the "Port Index Availability" section on page 1-28 for possible configurations.) • One - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 26
to [email protected]. Figure 1-1 Cisco MDS 9513 Chassis Front Panel View 1 2 3 144465 4 1 Switching or services modules in slots 1-6 2 Supervisor-2 modules in slots 7 and 8 3 Switching or services modules in slots 9-13 4 Fan tray The rear of the chassis supports two vertical - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 27
Chapter 1 Product Overview Chassis Send documentation comments to [email protected]. Figure 1-2 Rear Panel 9513 Chassis 1 2 144426 5 4 3 1 Power supplies 2 crossbar module fans panel to access the clock modules. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-5 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 28
. Cisco MDS 9509 Director The Cisco MDS 9509 Director has a 9-slot chassis as shown in Figure 1-3, and it supports the following: • Redundant Supervisor-2 modules with associated internal crossbar modules. • Up to two Supervisor-1 modules that provide a switching fabric, plus a console port, COM1 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 29
documentation comments to [email protected]. Cisco MDS 9506 Director The Cisco MDS 9506 Director has a 6-slot chassis as shown in Figure 1-4, and it supports the following: • Up to two Supervisor-1 modules that provide a switching fabric, with a console port, COM1 port, and a MGMT 10/100 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 30
module is active and in use. Clock module is in standby mode. Power supply is on and working properly. Power supply is not in a stable state. If this indication continues after initial power on, check that all connections are secure. Normal operation or power supply is turned off. Cisco MDS 9500 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 31
Channel infrastructure. The Cisco MDS Fibre Channel Bladeswitch for IBM BladeCenter provides 4-Gb Fibre Channel performance to blade-server switching. It also provides network intelligence features such as virtual SANs (VSANs), quality of service (QoS), and N-port interface virtualization (NPIV). It - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 32
MDS 9513 Power Supplies The Cisco MDS 9513 Director supports the 6000-W AC power supply (AC input). (See Figure 1-6.) Figure 1-6 Cisco MDS 9513 Power Supply 3 2 1 144466 1 Power supply switch 2 AC power connection 3 Power Supply LEDs 1-10 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 33
power supply is off. Power supply is not in a stable state. If this indication continues after initial power on, check that all connections are secure, including the system fan tray. Normal operation or power supply is turned off. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-11 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 34
Figure 1-7 4000-W AC Power Supply for the Cisco MDS 9509 Director 1 99370 5 I 0 4 INPUT OK FAN OUTPUT OK FAIL 3 2 1 AC power connection 2 Power supply LEDs 3 Captive screws 4 Power supply switch 5 Permanent power cable 1-12 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 35
comments to [email protected]. Figure 1-8 3000-W AC Power Supply for the Cisco MDS 9509 Director 1 2 3 4 5 5 1 AC power connection 2 Power cable 3 Power supply switch 4 Power supply LEDs 5 Captive screws 144986 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-13 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 36
1 94992 2 I 0 3 INPUT OK FAN OUTPUT OK FAIL 4 5 1 AC power connection 2 Cable retention device 3 Power supply switch 4 Captive screws 5 Power supply LEDs Figure 1-10 2500-W DC Power Supply for the Cisco MDS 9509 Director 1 99360 5 I 0 4 INPUT FAN OUTPUT OK OK FAIL 3 2 1 Terminal - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 37
comments to [email protected]. Cisco MDS 9506 Power Supplies The Cisco MDS 9506 Director supports the following types of connections are secure, including the system fan tray. Normal operation or power supply is turned off. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 38
properly seated in the chassis or power supply has failed. Caution The Cisco MDS 9000 Family switches have internal temperature sensors that are capable of shutting down the system factory installed bootflash is not supported. 1-16 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 39
Figure 1-12.) Supervisor-2 modules can be used in the Cisco MDS 9509 and 9506 Directors in slots 5 and 6. Supervisor-2 modules must be used in slots 7 and 8 of the Cisco MDS 9513 Director. Supervisor-2 modules provide an integrated crossbar switching fabric to connect all the switching modules when - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 40
: • RS-232 (EIA/TIA-232) console port with an RJ-45 connection that you can use to: - Configure the Cisco MDS 9500 Series from the CLI - Monitor network statistics and errors - Configure SNMP agent parameters • RS-232 COM1 port with a DB-9 connector, which can be attached to a modem. • Front - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 41
Send documentation comments to [email protected]. • Two USB ports provide a simple interface allowing you to connect to different devices supported by Cisco MDS NX-OS. On the double decker connector, USB port 1 is on the lower position and port 2 is on the upper position. • Supervisor - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 42
LED Green Off Link is up. No link. MGMT 10/100 Green Ethernet Off Activity LED Traffic is flowing through port. No link or no traffic. CompactFlash Green The external CompactFlash card is being accessed. Off No activity. 1-20 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 43
and Management, page 1-21 • Crossbar Switching Fabric, page 1-22 • Processor, page 1-22 • Port Interfaces, page 1-22 • LEDs on the Supervisor-1 Module, page 1-23 Note Supervisor-1 is not supported on the Cisco MDS 9513 Director. Figure 1-14 shows a Cisco MDS 9500 Series Supervisor-1 module. Figure - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 44
connect all the switching modules. Single fabric configurations provide 720-Gbps full duplex speed with 80-Gbps full duplex bandwidth per switching module. Dual fabric configurations provide 1.4-Tbps speed with 160-Gbps full duplex bandwidth per switching module. The Cisco MDS 9500 Series supports - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 45
MDS switches and are formatted using Cisco MDS switches. Using CompactFlash devices that are uncertified or are formatted using other platforms may result in errors. LEDs on the Supervisor-1 Module The front panel on the Supervisor-1 module has the following LEDs: • Status LED • System LED • Active - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 46
through port. No link or no traffic. CompactFlash Green The external CompactFlash card is being accessed. Off No activity. 1. The System and Pwr Mgmt LEDs on a redundant supervisor module are synchronized to the active supervisor module. 1-24 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 47
information about these LEDs. For information regarding migrating to Generation 3 modules, see the "Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules" section on page A-1. Figure 1-16 Crossbar Module LEDs 181335 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-25 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 48
. The module is not operational because a fault occurred during the initialization sequence. • An over-temperature condition occurred (a major threshold was exceeded during environmental monitoring). 1-26 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 49
(MSM-18/4) module 18-port Fibre Channel and 4-port Gigabit Ethernet IP X X X X X X Services FIPS (MSFM-18/4) module 14-port Fibre Channel/2-port Gigabit Ethernet Multiprotocol Services (MPS-14/2) module X X X X X X OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-27 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 50
Availability The Cisco MDS 9500 Multilayer Directors are designed to operate with any combination of Cisco MDS 9000 modules. However, you should be aware of the maximum port availability your chassis can support. A port index is an internally assigned number that Cisco NX-OS uses to switch data - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 51
more indexes, it starts borrowing available indexes from slot 1 of the chassis until it has the number of port indexes necessary. Note Enter the purge module CLI command to free up reserved port indexes after you remove a module. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-29 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 52
in Cisco MDS 9509 Director 12-port 4-Gbps Fibre Channel switching module 48-port 4-Gbps Fibre Channel switching module 48-port 4-Gbps Fibre Channel switching module 48-port 4-Gbps Fibre Channel switching module Supervisor-1 Supervisor-1 48-port 4-Gbps Fibre Channel switching module 48-port 4-Gbps - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 53
2 modules in a Cisco MDS 9513 Director. Table 1-12 Maximum Chassis Configuration on a Cisco MDS 9513 Director (Valid) Slot No. 1 2 3 4 5 6 7 8 9 10 Modules in Cisco MDS 9513 Director 48-port 4-Gbps Fibre Channel switching module 48-port 4-Gbps Fibre Channel switching module 48-port 4-Gbps Fibre - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 54
- 24-port 4-Gbps Fibre Channel Switching Module - 12-port 4-Gbps Fibre Channel Switching Module - 4-port 10-Gbps Fibre Channel Switching Module • Generation 1 modules - 32-Port 2-Gbps Fibre Channel Switching Module - 16-Port 2-Gbps Fibre Channel Switching Module The Cisco MDS 9500 Series supports up - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 55
in the Cisco MDS 9500 Series Switches. The 24-port switching module can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated bandwidth mode. Figure 1-18 shows a 24-port 8-Gbps Fibre Channel switching module. The front panel connectors support standard modular - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 56
and in the Cisco MDS 9216i and 9216A Switches. The 48-port switching module can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated bandwidth mode. Figure 1-20 shows a 48-port 4-Gbps Fibre Channel switching module. The front panel connectors support standard - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 57
module. The front panel connectors support standard modular SFP and the speed detection is autosensing. Figure 1-23 12-Port 4-Gbps Fibre Channel Switching Module 2 144470 1 3 1 Status LED 2 Fibre Channel ports OL-17467-02 3 Link LEDs Cisco MDS 9500 Series Hardware Installation Guide 1-35 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 58
. The front panel connectors support standard modular X2 interfaces and the speed is fixed at 10 Gbps. Figure 1-24 4-Port 10-Gbps Fibre Channel Switching Module 144473 1 2 1 Status LED 2 X2 port interfaces 3 3 Link LED 1-36 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 59
a port group share a single internal channel resulting in a subscription ratio of approximately 3.2 to 1. The 32-port 2-Gbps switching module provides more ports at a lower price per port. Figure 1-25 shows a 32-port switching module. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 60
. Tip For a full 2-Gbps bandwidth between two hosts, connect one host to the first port group and the second host to the second port group. Figure 1-25 DS-X9032 17 Cisco MDS 9000 Family 32-Port 2-Gbps Switching Module 2 4 5 20 21 8 9 24 25 12 13 16 28 29 32 91673 1 3 4 1 Status - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 61
disable other switching modules if that is the only failure in the system. Each switching module has a hardware watchdog timer for detecting most component failures. This watchdog resets the card if is not serviced periodically. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-39 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 62
Channel switching modules provide autoconfiguring Fibre Channel ports that support Fibre Channel speeds of 1.0625 Gbps and 2.125 Gbps. For more information about supported port types, see the Cisco MDS 9000 Family CLI Configuration Guide. 1-40 Cisco MDS 9500 Series Hardware Installation Guide OL - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 63
single Fibre Channel port. The MSM-18/4 supports hardware-based encryption and it is required to run the Storage Media Encryption (SME) which, is a part of the Cisco NX-OS. For more information on SME, see the Cisco MDS Storage Media Encryption Guide. The MSM-18/4 supports SAN extension over IP and - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 64
MDS 9500 Series switches running Cisco MDS SAN-OS Release 3.2(1) or later, or NX-OS Release 4.1(1b) support the MSM-18/4 and the MSFM-18/4 module. Figure 1-27 shows the MSM-18/4 module. Figure 1-27 18/4-Port Multiservice Module 1 2 184706 4 3 1 Status LED 3 Gigabit Ethernet ports 2 1-Gbps - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 65
Services Modules Send documentation comments to [email protected]. LEDs on the 18/4-Port Multiservice Module Table 1-15 describes the LEDs for the 18/4-port Multiservice module. Table 1-15 LEDs for the Cisco MDS 9000 Family 18/4-Port Cisco MDS 9500 Series Hardware Installation Guide 1-43 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 66
about configuring the ports, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS Family Fabric Manager Configuration Guide. The Fibre Channel port interfaces support hot-swappable Fibre Channel SFP transceivers, which can be short wavelength (SWL) for connectivity up to 1640 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 67
Chapter 1 Product Overview Services Modules Send documentation comments to [email protected]. Figure 1-28 shows an MPS-14/2 module. Figure 1-28 Cisco MDS 9000 Family MPS-14/2 Module 2 4 STATUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 LINK- 1 2 LINK- GIGABIT E THERNET LINK - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 68
about configuring the ports, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS Family Fabric Manager Configuration Guide. The Fibre Channel port interfaces support hot-swappable Gigabit Ethernet SFP transceivers, which can be short wavelength (SWL) for connectivity up to 1640 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 69
ports 3 Link LEDs 4 Asset tag LEDs on IP Storage Services Modules Table 1-17 describes the LEDs for the IPS services modules. Table 1-17 LEDs for the Cisco MDS port). Link is disabled by software. A fault condition exists. No link. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 70
incorporates all the capabilities of the Cisco MDS 9000 DS-X9032 Fibre Channel switching module and also provides scalable, in-band storage virtualization services. The module makes it possible to allocate bandwidth optimally. The Fibre Channel port interfaces support hot-swappable Fibre Channel SFP - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 71
). The card shut down to prevent permanent damage. 2-Gbps mode. 1-Gbps mode. Link is up. Link is up (beacon used to identify port). Link is up (traffic on port). Link is disabled by software. A fault condition exists. No link. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-49 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 72
, and supports future storage services. Note Cisco MDS 9500 Series switches running Cisco MDS SAN-OS Release 2.x, 3.x, or NX-OS Release 4.1(1b) support the SSM. The Fibre Channel ports support hot-swappable Fibre Channel SFP transceivers, which can be short wavelength (SWL) for connectivity up to - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 73
failures, each switching module has a hardware watchdog timer that resets the card if is not serviced periodically. LEDs on the Storage Services Modules Table 1-19 describes the LEDs for the Storage Services Modules. Table 1-19 LEDs for the Cisco MDS 9000 Family Storage Services Modules LED - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 74
Overview Send documentation comments to [email protected]. Caching Services Module The Caching Services Module (CSM) provides virtualization services that allow the Cisco MDS 9000 Family switches to reallocate physical resources as virtual resources for increased efficiency. The CSM - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 75
2 2 Disk drive 1 3 Battery 2 4 Battery 1 See the "Installing a Switching or Services Module, Including Caching Services Modules" section on page 2-45 for information about installing the CSM and maintaining the CSM batteries. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-53 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 76
[email protected]. LEDs on the Caching Services Module Table 1-20 describes the LEDs for the CSM. Table 1-20 LED Status Node Battery Disk LEDs for the Cisco MDS 9000 . Red Disk failure. Off Disk does not have power. 1-54 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 77
Channel DWDM SFP transceiver, which can be used for ELWL transmission or for DWDM Note Switches running Cisco MDS SAN-OS Release 1.x, 2.x, 3.x, or NX-OS Release 4.1(1b) support combination Fibre Channel/Gigabit Ethernet SFP transceivers. The transceivers are field-replaceable and hot-swappable - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 78
be connected to services (IPS-4 and IPS-8) modules provide four or eight 1-Gigabit Ethernet ports that support Gigabit Ethernet SFP transceivers. The Gigabit Ethernet SFP transceivers have RJ-45 connectors and support Gigabit Ethernet (1-Gbps). 1-56 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 79
. • ELWL signals can transmit over longer distances than LWL SFP transceivers. For more information about Gigabit Ethernet SFP transceiver specifications, see the "SFP and SFP+ Transceiver Specifications" section on page D-22. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-57 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 80
Supported Transceivers Chapter 1 Product Overview Send documentation comments to [email protected]. 1-58 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 81
Modules, page 2-76 Note Before you install, operate, or service the system, read the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family for important safety information. Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol indicates danger. You are in a situation that - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 82
the switch - The telco and EIA Shelf Bracket Kit (optional and purchased separately) in addition to the rack-mount kit shipped with the switch • In a perforated or solid-walled EIA cabinet, using: - The rack-mount kit shipped with the switch Cisco MDS 9500 Series Hardware Installation Guide 2-2 OL - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 83
instructions on installing the switch using the optional telco and EIA Shelf Bracket Kit (purchased separately), see the "Cisco MDS Specifications." You can use an uninterruptible power supply (UPS) to protect against power failures. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 84
and Maintenance Records." • Use the following screw torques when installing the switch: - Captive screws: 4 in-lb - M3 screws: 4 in-lb - M4 screws: 12 in-lb - M6 screws: 20 in-lb - 10-32 screws: 20 in-lb - 12-24 screws: 30 in-lb Cisco MDS 9500 Series Hardware Installation Guide 2-4 OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 85
Cisco MDS 9513 Director, you need a mechanical lift to handle the weight of the chassis. Unpacking and Inspecting the Switch support the weight of the chassis. Statement 5 Caution Use a mechanical lift to lift the MDS 9513 chassis. The Cisco MDS Cisco MDS 9500 Series Hardware Installation Guide 2-5 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 86
from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Note The switch is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, contact your customer service representative - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 87
for the Rack-Mount Support Bracket Kit Part Description Rack-mount support bracket Rack-mount support bar 12-24 x 3/4-in. Phillips screws 10-32 x 3/4-in. Phillips screws To install the Cisco MDS 9513 chassis in a rack using the rack-mount kit provided with the switch, follow these steps: Step - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 88
to the rail. Figure 2-1 Positioning the Rack-Mount Support Brackets 146035 26.56 in Step 3 Install one rack-mount support bar into the slots located on the rack-mount support brackets. Repeat this for the other support bar. Cisco MDS 9500 Series Hardware Installation Guide 2-8 OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 89
with the switch, do not install the top four screws to the front right side of the bracket. These will be installed after placing the cable management bracket along that side. The bottom screw should be installed to support the front of the rack-mount support bracket. OL-17467-02 Cisco MDS 9500 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 90
with the holes in the mounting rails and insert the 12-24 x 3/4-inch or 10-32 x 3/4-inch screws, using six screws per side. (See Figure 2-4.) Note Use a minimum of six screws to ensure that the switch is adequately supported. 2-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 91
2-4 Installing the Cable Management Brackets on the MDS 9513 Chassis 3 4 1 2 146038 1 Screws, 12-24 or 10-32 2 Support bracket 3 Mounting rail 4 Cable guide Installing the Cisco MDS 9509 Director in a Rack Caution If connecting a Cisco MDS 9509 Director to a 110-VAC power system, ensure - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 92
management bracket kit 2 Cable management brackets 18 12-24 x 3/4-inch Phillips binder-head screws 18 10-32 x 3/4-inch Phillips binder-head screws To install the Cisco MDS 9509 chassis in a rack using the rack-mount kit provided with the switch, follow these steps: Step 1 Step 2 Position - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 93
comments to [email protected]. Figure 2-5 Installing the Side Rack-Mount Brackets for the Cisco MDS 9509 Chassis 1 2 1 94997 1 Side rack-mount bracket 2 Screws, 12-24 or 10-32 Step -mount brackets (see Figure 2-7). OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-13 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 94
the holes in the mounting rails and insert the 12-24 x 3/4-inch or 10-32 x 3/4-inch screws (see Figure 2-8), using six screws per side. Note Use a minimum of six screws per side to ensure that the switch is adequately supported. 2-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 95
Cable Management Bracket on the MDS 9509 Chassis 4 2 99023 3 1 1 Screws, 12-24 or 10-32 3 Mounting rail 2 Front rack-mount bracket (behind 4 Cable guide cable guide) Installing the Cisco MDS 9506 Director in a Rack Table 2-3 lists the items provided in the Cisco MDS 9506 rack-mount kit. The - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 96
of a Cisco MDS 9506 director into a rack, using the cable management bracket. Figure 2-9 Installing the Cisco MDS 9506 Chassis in the Rack 2 99021 14 3 1 Screws, 12-24 or 10-32 2 Front rack-mount bracket (behind cable guide) 3 Mounting rail 4 Cable management bracket 2-16 Cisco MDS 9500 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 97
cisco.com. To install the Cisco MDS 9506 chassis in the rack using the rack-mount kit, follow these steps: Step 1 Place all the parts and screwdrivers near the rack for easy access while attaching the switch 2-9), supporting the switch inside the chassis is level. Insert the 12-24 x 3/4-inch or 10- - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 98
a standard office environment. Appropriate grounding practices should be followed as much as possible. Electromagnetic noise problems are not anticipated, but installing a best practice grounding system is always recommended. 2-18 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 99
does not have the system ground attached, you must install the system ground lug. For installation instructions and location of the chassis system ground pads, see "Establishing the System Ground" section on page to your bare skin. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-19 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 100
an alligator clip, attach the alligator clip directly over the head of the system ground lug screw or to the system ground lug barrel. 2-20 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 101
an antistatic surface or in a static shielding container. If you plan to return the component to the factory, immediately place it in a static shielding container. Cisco MDS 9500 Series Hardware Installation Guide 2-21 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 102
To connect the ground system, you need the following tools and materials: • Grounding lug-A two-hole standard barrel lug. Supports up to 6 AWG wire. Supplied as part of accessory kit. • Grounding screws-Two M4 x 8mm (metric) pan-head screws. Supplied as part of the accessory kit. 2-22 Cisco MDS - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 103
. Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046 Figure 2-11 shows the system ground location on the front panel of the Cisco MDS 9513 chassis. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-23 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 104
2 1 Grounding cable 2 Screws, M4, with square cone washers 3 NRTL listed grounding lug 4 Close-up of grounding pad on switch 5 ESD plug Figure 2-12 shows the ESD ground location on the rear panel of the Cisco MDS 9513 chassis. 2-24 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 105
be the grounding type, and the grounding conductors should connect to protective earth ground at the service equipment. For a Cisco MDS 9509 Director with a DC power supply, a grounding cable must be connected to the terminal block. For a Cisco MDS 9506 Director with a DC power supply, the chassis - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 106
of grounding pad on switch 99270 Caution Grounding the chassis is required for Cisco MDS 9506 Directors that have DC power supplies, and Cisco recommends grounding for all system ground location on the Cisco MDS 9506 chassis. 2-26 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 107
[email protected]. Figure 2-14 System Ground Location on the Cisco MDS 9506 Chassis 1 2 99269 3 4 6 5 1 ESD socket (on switch) 2 and connect it to an appropriate grounding point in your site to ensure adequate earth ground. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 108
adequate power to all modules present in the system. See Appendix D, "Technical Specifications." Connecting the Power Supplies The Cisco MDS 9513 Director uses a 6000-W power supply. The 6000-W AC power supplies for the Cisco MDS 9513 Director are designed to provide an output power for the modules - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 109
Chapter 2 Installing the Cisco MDS 9500 Series Starting Up the Switch Send documentation comments to [email protected]. Providing Power to an AC Power Supply for the Cisco MDS 9513 Director To provide power to an AC power supply in a Cisco MDS 9513 Director, follow these steps: Step 1 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 110
2 I 0 3 INPUT OK FAN OUTPUT OK FAIL 4 5 1 AC power connection 2 Power cable retainer 3 Power supply switch 4 Captive screws 5 Power supply LEDs Figure 2-17 shows a 4000-W AC power supply for the Cisco MDS 9509 Director. 2-30 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 111
connection is essential before connecting power supply. Figure 2-18 shows an AC PEM for a Cisco MDS 9506 Director. Figure 2-18 AC PEM for Cisco MDS 9506 Director 94981 12 31 1 Captive screws 2 PEM switch 3 AC power connection OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 112
on the outlet receptacle on your power distribution unit, you may need the optional jumper power cord to connect the Cisco MDS 9500 Series director to your outlet receptacle. See the "Jumper Power Cord" section on page E-11. 2-32 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 113
Ensure that all power is off. Locate the circuit breaker on the panel board that services the DC circuit. Switch the circuit breaker to the off position, and then tape the switch handle of the circuit breaker in the off position. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-33 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 114
are no other DC power cables to connect and you are ready to power the switch on, restore power to the DC circuit by removing the tape from the circuit breaker handle and flipping the handle to on. Providing Power to a DC Power Supply in the Cisco MDS 9506 Director Warning Before performing any - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 115
the PEM to connect them to the screws. Figure 2-21 DC PEM for a Cisco MDS 9506 Director Cisco MDS 9506 Director, follow these steps: Step 1 Step 2 Step 3 Step 4 Ensure that all power to the DC circuit is off by locating the circuit breaker on the panel board that services the DC circuit. Switch - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 116
For instructions on configuring the switch, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. For instructions on connecting to the console port, see the "Connecting to the Console Port" section on page B-2). 2-36 Cisco MDS 9500 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 117
, see Appendix D, "Technical Specifications." If a component is not operating correctly, try removing and reinstalling it. If it still does not operate correctly, contact your customer service representative for a replacement. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-37 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 118
. For instructions about how to configure the switch and check module connectivity, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. Removing, Installing, and Verifying Supervisor, Switching, and Services Modules This - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 119
: Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Shut down the crossbar switching fabric functionality in the supervisor module of the Cisco MDS 9509 and 9506 Directors by using the out-of-service module slot command (where slot refers to the slot number for the Supervisor-1 or Supervisor - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 120
remove the panel. To remove a currently installed module, see the "Removing Other Switching and Services Modules" section on page 2-45. Open both the ejector levers on the new or replacement module completely. (See Figure 2-22.) 2-40 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 121
Chapter 2 Installing the Cisco MDS 9500 Series Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Send documentation comments to [email protected]. Figure 2-22 Positioning a Module in the Chassis 1 2 3 4 4 5 66 3 94987 4 1 Slot guides 2 EMI Gasket - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 122
, and Verifying Supervisor, Switching, and Services Modules Chapter 2 Installing the Cisco MDS 9500 Series Send documentation comments to [email protected]. Figure 2-23 Clearing the EMI Gasket Press down gently Press down gently 91690 4 WS-C6500-SFM 5 SWITCH FABIRD MDL 6 1mm - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 123
about the auto-sync option, see the Cisco MDS 9000 Family CLI Configuration Guide. If you replaced the supervisor in a switch that does not have a second supervisor or is running Cisco MDS SAN-OS Release 1.3(1) or later or NX-OS Release 4.1(1b), download the configuration from the server to the - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 124
Switching, and Services Modules Chapter 2 Installing the Cisco MDS 9500 Series Send documentation comments to [email protected]. Removing a Caching Services Module Note A minimum of two CSMs in each fabric command to use, see the Cisco MDS 9000 Family CLI Configuration Guide to support the - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 125
Cisco MDS 9500 Series Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Send documentation comments to [email protected]. Removing Other Switching and Services Modules To remove a switching or services hand under the module to support the weight of the module - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 126
2-24.) Cisco MDS SAN-OS Release 1.3(1) or later or NX-OS Release 4.1(1b), download the configuration from the server to the nonvolatile memory of the supervisor. For more information, see the Cisco MDS 9000 Family CLI Configuration Guide. Verifying Installation of Supervisor, Switching, and Services - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 127
and Services Modules Send documentation comments to [email protected]. Step 4 Turn on the power supply switches to power up the system and check the LEDs on the modules. Note For information about how to check connectivity of modules, see the Cisco MDS 9000 Family CLI Configuration Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 128
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Chapter 2 Installing the Cisco MDS 9500 Series Send documentation comments to [email protected]. Figure 2-25 Captive Screws and Ejector Levers on the Crossbar Module 1 2 2 144526 1 1 Captive screws 2 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 129
Chapter 2 Installing the Cisco MDS 9500 Series Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Send documentation comments to [email protected]. Step 2 Step 3 are flush with the front of the module. Cisco MDS 9500 Series Hardware Installation Guide 2-49 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 130
Services Module Chapter 2 Installing the Cisco MDS 9500 Series Send documentation comments to mdsfeedback-doc@cisco. support provider for assistance. If a battery fails, the CSM must be replaced. The other CSMs in the fabric contain the same data, and they continue providing caching services - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 131
CSM(s) in the fabric contain the same data, and they continue providing caching services during the replacement period. Removing and Installing a Power Supply or PEM This section provides the following information: • Removing and Installing the Power Supplies on the Cisco MDS 9513 Director, page - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 132
. Statement 166 To remove an AC power supply from the Cisco MDS 9513 Director, follow these steps: Step 1 Step 2 Step 3 Turn the power switch on the power supply to the off (0) position. There at the corners of the power supply. 2-52 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 133
the power supply. Assure adequate support with both hands on the unit at the designated support points, and slowly pull the power supply out of the chassis so that the weight of the unit will be fully supported once it is removed. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-53 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 134
power supply in the Cisco MDS 9513 Director, follow these steps: Step 1 Step 2 Step 3 Ensure that the system (earth) ground connection has been made. switch is in the off (0) position on the power supply you are installing. (See Figure 2-29.) 2-54 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 135
switch to the on (|) position on the power supply. Verify power supply operation by checking that the power supply LEDs are in the following states: • INPUT OK LEDs are green. • FANs OK LED is green. • OUTPUT FAIL LED is off. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-55 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 136
Cisco MDS 9509 Director, follow these steps: Step 1 Step 2 Step 3 Turn the power switch on the power supply to the off (0) position. Turning the power switch and remove power supplies. Each Cisco MDS 9500 Series AC power supply weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg). Step 5 Step 6 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 137
2500-W power supplies weigh up to 28 lb (12.6 kg). The 3000-W power supply weighs up to 24 lb (11 kg). To install an AC power supply in the Cisco MDS 9509 Director, follow these steps: Step 1 Step 2 Ensure that the system (earth) ground connection has been made. See the "System Grounding" section - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 138
Figure 2-31 4000-W AC Power Supply for the Cisco MDS 9509 Director 1 99370 5 I 0 4 INPUT OK FAN OUTPUT OK FAIL 3 2 1 AC power connection 2 Power supply LEDs 3 Captive screw 4 Power supply switch 5 Permanent power cable 2-58 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 139
comments to [email protected]. Figure 2-32 3000-W AC Power Supply for the Cisco MDS 9509 Director 1 2 3 4 5 5 1 AC power connection 2 Power cable 3 Power supply switch 4 Power supply LEDs 5 Captive screws 144986 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-59 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 140
is green. • FAN OK LED is green. • OUTPUT FAIL LED is off. If the LEDs indicate a power problem, see the Cisco MDS 9000 Family Troubleshooting Guide. If you cannot resolve an issue, contact your customer service representative. 2-60 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 141
circuit. Statement 1003 To remove a DC power supply from the Cisco MDS 9509 Director, follow these steps: Step 1 Step 2 Step 3 Ensure that all power is off by locating the circuit breaker on the panel board that services the DC circuit. Switch the circuit breaker to the off position, and tape the - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 142
Ensure that all power is off by locating the circuit breaker on the panel board that services the DC circuit. Switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position. 2-62 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 143
connect switch on also locks the power supply in the chassis. Verify power supply operation by checking that the power supply LEDs are in the following states: • INPUT OK LED is green. • FAN OK LED is green. • Output fail LED is off. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 144
.com. Removing and Installing the PEMs on the Cisco MDS 9506 Director Note For instructions on connecting the cables to the PEMs, see the "Connecting the Power Supplies" section on page 2-28. The Cisco MDS 9506 Director uses PEMs to provide an input power connection on the front of the chassis. In - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 145
Chapter 2 Installing the Cisco MDS 9500 Series Removing and Installing a Power Supply or PEM Send documentation comments to [email protected]. Figure 2-35 Connecting or Disconnecting the DC PEM () () to 8 in-lb. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-65 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 146
Power to an AC Power Supply for the Cisco MDS 9509 and Cisco MDS 9506 Directors" section on page 2-30. Caution In a system with dual power supplies, connect each power supply to a separate power source . • FAN OK LED is green. 2-66 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 147
AC or DC power supply from the Cisco MDS 9506 Director, follow these steps: Step 1 Step 2 Step 3 Remove power from the PEM that corresponds to the power supply as follows: • If the PEM is AC, press the power switch to off (0). • If the PEM is DC, follow the instructions in the "Removing a DC PEM - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 148
are the same for all types of fan modules. You need a flat-blade or number 2 Phillips screwdriver to perform these procedures. Note Because the fan modules are located on the left side of the Cisco MDS 9500 Series, Cisco recommends guiding the cables for the system out of the right side of the - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 149
removed from the chassis, the Cisco MDS 9000 Family switches will be shut down after five minutes to prevent potentially undetectable overheating. However, the switches will be shut down sooner if the chassis. (See Figure 2-36.) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-69 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 150
make contact with the chassis. The fan module will just snap in. If the switch is powered on, listen for the fans; you should immediately hear them operating. , contact your customer service representative for a replacement part. 2-70 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 151
screws and pull the fan tray out of the chassis using both hands. Take one hand and hold the face of the fan tray while supporting it with the other hand. Pull the fan module clear of the chassis. (See Figure 2-37.) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-71 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 152
Removing and Installing Fan Modules Chapter 2 Installing the Cisco MDS 9500 Series Send documentation comments to [email protected]. Figure 2-38 Removing a Crossbar Module Fan module fan tray to 8 in-lb screws. 2-72 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 153
[email protected]. Removing a Front Fan Module on the Cisco MDS 9509 Director To remove a fan module from the Cisco MDS 9509 or 9506 switch, guides, then push the fan module into the chassis until it seats in the backplane and the captive screws make contact with the chassis. OL-17467-02 Cisco MDS - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 154
that the Fan Status LED is green. If the LED is not green, one or more fans are faulty. If this occurs, contact your customer service representative for a replacement part. 2-74 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 155
. For information on formatting the external CompactFlash, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. You can install and remove the CompactFlash card with the switch powered on. Caution Do not remove the CompactFlash card - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 156
2 Phillips screwdriver • Your own ESD-prevention equipment or the disposable grounding wrist strap included with all upgrade kits, field-replaceable units (FRUs), and spares 2-76 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 157
clock module you are removing. Use the show environment clock command to verify which is active and standby. Use a Phillips screwdriver to remove the eight back panel screws from the rear of the Cisco MDS 9513 Director chassis. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-77 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 158
Modules Chapter 2 Installing the Cisco MDS 9500 Series Send documentation comments to [email protected]. Note Note the position or foam. (See Figure 2-41.) Figure 2-41 Clock Module Replacement on the Cisco MDS 9513 Director (Rear View) Sheet metal side Component side Step 5 Repeat Step - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 159
to the power supplies as described in the "Connecting the Power Supplies" section on page 2-28. Caution In a system with dual power supplies, connect each power supply to a separate power source. In green. • FAN OK LED is green. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-79 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 160
all upgrade kits, field-replaceable units (FRUs), and spares Clock modules are connected to the rear of the Cisco MDS 9509 Director using two connectors. Figure 2-43 shows the clock modules in a rear view of the Cisco MDS 9509 Director with the back panel removed. Figure 2-43 Clock Module Location - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 161
, press the power switch to off (0) and remove the power cable. • If the power supply is DC, follow the instructions in the "Providing Power to a DC Power Supply in the Cisco MDS 9509 Director" section . (See Figure 2-44.) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-81 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 162
gently remove the module, placing it on an antistatic mat or foam. Step 5 Repeat Step 3 and Step 4 to remove any additional clock modules. 120166 2-82 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 163
kit, part number DS-C9506-CL=. Table 2-7 Contents of Cisco MDS 9506 Clock Module Replacement Kit Quantity 1 12 1 Part Description Cisco MDS 9506 clock module M3 x 6-mm Phillips pan-head screws Disposable ESD wrist strap OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-83 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 164
Figure 2-45 Clock Module Location on the Cisco MDS 9506 Director (Rear View) 1 120093 Cisco MDS 9506 1 Clock module Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal components. 2-84 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 165
as follows: • If the PEM is AC, press the power switch to off (0). Remove the power cord from the PEM. • If the PEM is DC, follow the instructions in the "Removing a DC PEM" section on page 2-64. clock module in the same position. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-85 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 166
power to the PEMs as described in the "Connecting the Power Supplies" section on page 2-28. Caution In a system with dual power supplies, connect each power supply to a separate power source. green. • OUTPUT FAIL LED is off. 2-86 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 167
, DS-13SLT-FAB1 The MDS 9513 Director requires Cisco MDS NX-OS 4.1(1b) and the MDS 9513 Fabric 2 modules to support the MDS 9000 48-port 8-Gbps Fibre Channel module and the MDS 9000 24-port 8-Gbps Fibre Channel module. Two MDS 9513 Fabric 2 modules can double the active backplane bandwidth of the - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 168
Director, be aware of the following usage guidelines: • Cisco SAN-OS release 3.x supports the MDS 9513 Fabric 2 module. • Until you upgrade to Cisco NX-OS 4.1(1b) and reload the switch, a MDS 9513 Fabric 2 module functions like a MDS 9513 Fabric 1 module. • You cannot use any Generation 3 8-Gbps - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 169
nondisruptively upgrade to Cisco NX-OS 4.1(1b), and install the MDS 9000 4/44-port 8-Gbps Host-Optimized module, follow these steps: Step 1 Connect a PC to the console port on the active supervisor module and log in to the switch. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide A-3 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 170
that the MDS 9513 Director is running Cisco SAN-OS 3.x by entering the show version command at the command line. This example shows the output of the show version command: switch# show version Cisco Storage Area Networking Operating System (SAN-OS) Software TAC support: http://www.cisco.com/tac - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 171
remove a MDS 9513 Fabric 1 module from the Cisco MDS 9513 Director and replace it with a MDS 9513 Fabric 2 module, follow these steps: Step 1 Step 2 Connect a PC to the console port on the active supervisor module and log in to the switch. Enter the show module command to determine - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 172
[email protected]. Step 5 Step 6 Step 7 Step 8 switch# show module Mod Ports Module-Type Model Status 7 0 8 0 Supervisor/Fabric-2 Supervisor/Fabric-2 DS-X9530-SF2-K9 DS-X9530-SF2-K9 ha-standby active * switch# out-of-service xbar 1 Enter the show module xbar command to verify - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 173
to Generation 3 8-Gbps Fibre Channel Switching Modules Migration Procedures for the MDS 9513 Director Send documentation comments to [email protected]. Figure A-1 Captive Screws and Ejector Levers on the Fabric Module 1 2 3 4 2 5 188730 1 Captive screws 3 Fabric slot 1 label 5 Power - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 174
of the module being inserted. If it does not, check to see if the module is seated correctly in the slot. Enter the system switchover command to put the other supervisor in active mode. Cisco MDS 9500 Series Hardware Installation Guide A-8 OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 175
to Cisco NX-OS 4.1(1b) and reload the switch, the MDS 9513 Fabric 2 modules function like MDS 9513 Fabric 1 modules. Installing MDS 9513 Fabric 2 Modules and Installing MDS 9000 24-port or 48-port 8-Gbps Modules This procedure allows you to install the MDS 9513 Fabric 2 modules and activate the - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 176
3 module support. The following example shows the output of the show hardware fabric-mode command, which indicates that support for the MDS 9000 48-port and 24-port 8-Gbps Generation 3 modules has not been enabled for the switch. A-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 177
mode command, and indicates that support for the MDS 9000 48-port and 24-port 8-Gbps Generation 3 modules has been activated. switch# show hardware fabric-mode Fabric mode supports Gen3 and above linecards. switch# Step 10 Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 178
[email protected]. Step 9 switch# show hardware fabric-mode Fabric mode supports Gen3 and above linecards. switch# Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric Manager Configuration Guide for information on how to configure the MDS 9000 48-port or 24-port - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 179
). Refer to the upgrade procedure described in the MDS 9000 Family CLI Configuration Guide. Install any Generation 3 8-Gbps module. Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric Manager Configuration Guide for information on how to configure a Generation - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 180
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules Migration Procedure for the MDS 9509 Director and MDS 9506 Director Send documentation comments to [email protected]. A-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 181
for in-band management. • Gigabit Ethernet ports (IP services modules)-Gigabit Ethernet ports that you can use for iSCSI and/or FCIP. • Two USB ports (Supervisor-2 module)-A simple interface that allows you to connect to different devices supported by Cisco MDS SAN-OS and NX-OS. On the double-decker - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 182
of asynchronous transmission. We recommend using this port to create a local management connection to set the IP address and other initial configuration settings before connecting the switch to the network for the first time. Cisco MDS 9500 Series Hardware Installation Guide B-2 OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 183
Send documentation comments to [email protected]. Figure B-1 Connecting to the Console Port on the Supervisor Module for the Cisco MDS 9500 Series Console 91701 Note Connecting the console port to a modem is supported for switches running Cisco MDS SAN-OS Release 1.2(2a) or later or - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 184
computer) at the computer serial port. Note For configuration instructions, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. Connecting to the COM1 Port Note The COM1 port is not supported for connection to a console. The COM1 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 185
kit, as follows: a. Connect the DB-9 serial adapter to the COM1 port. b. Connect the RJ-45 to DB-25 modem adapter to the modem. c. Connect the adapters using the RJ-45 to RJ-45 rollover cable (or equivalent crossover cable). OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide B-5 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 186
Cisco MDS 9000 Family CLI Configuration Guide. The Supervisor-2 module supports an autosensing MGMT 10/100/1000 Ethernet port (labeled "MGMT 10/100/1000") and has an RJ-45 interface. (See Figure B-3.) You can use this port to access and manage the switch by IP address, such as through Cisco Fabric - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 187
Cisco MDS 9000 Family CLI Configuration Guide. The Supervisor-1 module supports an autosensing MGMT 10/100 Ethernet port (labeled "MGMT 10/100") and has an RJ-45 interface. (See Figure B-4.) You can use this port to access and manage the switch by IP address, such as through Cisco Fabric Manager - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 188
Send documentation comments to [email protected]. Figure B-4 Connecting to the MGMT 10/100 Ethernet Port on the Supervisor-1 Module for the Cisco MDS 9500 Series 99328 MGMT 10/100 To connect the MGMT 10/100 Ethernet port to an external hub, switch, or router, follow these steps: Step - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 189
and cables. You can use these ports to connect to the SAN or for in-band management. For information about configuring the switch for in-band management, see the Cisco MDS 9000 Family CLI Configuration Guide. The Cisco MDS 9000 Family supports both Fibre Channel and Gigabit Ethernet protocols - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 190
Port Chapter B Connecting the Cisco MDS 9500 Series Send documentation comments to [email protected]. The Cisco MDS 9000 Family supports X2 transceivers with SC connectors. (See Figure B-5.) Figure B-5 Cisco MDS ) B-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 191
B Connecting the Cisco MDS 9500 Series Connecting to a Fibre Channel Port Send documentation comments to [email protected]. Removing an X2 Transceiver To remove an X2 transceiver, follow these steps: Step 1 Step 2 Attach an ESD-preventive wrist strap and follow its instructions for - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 192
to verify that the SFP transceiver meets the requirements for the switch. For instructions specific to the transceiver type, see the "SFP and SFP+ Transceiver Specifications" section on page D-22. The Cisco MDS 9000 Family supports SFP transceivers with the following two types of latching devices - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 193
Chapter B Connecting the Cisco MDS 9500 Series Connecting to a Fibre Channel Port Send documentation comments to [email protected]. c. Insert a dust plug into the cable end of optical cage by inserting a clean cover. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide B-13 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 194
Channel Port Chapter B Connecting the Cisco MDS 9500 Series Send documentation comments to [email protected]. Installing an SFP Transceiver To install an SFP transceiver, follow these steps: Step 1 Step 2 Step 3 Step 4 Attach an ESD-preventive wrist strap and follow its instructions for - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 195
Port LC plug SFP module 91681 Caution If the cable does not install easily, ensure that it is correctly oriented before continuing. For instructions on verifying connectivity, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 196
effective; refer to your site's fiber-optic connection cleaning procedure. • Inspect routinely for dust and damage. If damage is suspected, clean and then inspect fiber ends under a microscope to determine if damage has occurred. B-16 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 197
C-4. • Standard two-post telco rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992. See the "Requirements Specific to Two-Post Telco Racks" section on page C-6. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide C-1 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 198
Cisco MDS 9513 chassis: • The minimum vertical rack space per chassis: - Cisco MDS 9513 chassis: 24.5 inches (62.2 cm) or 14 RU, height with required rack mount support rack space per chassis: - Cisco MDS 9509 chassis: 24.5 inches (62.2 cm) or 14 RU - Cisco MDS 9506 chassis: 12.25 inches (31.1 cm) - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 199
, CA 91361 Customer Service and Technical Support phone number 800 834 Cisco recommends that the roof should be perforated with at least a 20 percent open area. • Cisco recommends an open or perforated cabinet floor to enhance cooling. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 200
Service and Technical Support Cisco MDS 9513 Director. Requirements Specific Cisco MDS 9513 Chassis The solid-walled cabinet requirements for the Cisco MDS 9513 chassis are as follows: • Perforated front and back doors and solid or open side panels. Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 201
the floor intake. Requirements Specific to Standard Open Racks Cisco MDS 9513 chassis: 24.5 inches (62.2 cm) or 14 RU. - Cisco MDS 9509 chassis: 24.5 inches (62.2 cm) or 14 RU. - Cisco MDS 9506 chassis: 12.25 inches (31.1 cm) or 7 RU. Note The rack-mount support brackets provided with the Cisco MDS - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 202
Mount Support Brackets, page C-11 • Installing the Switch on the Shelf Brackets, page C-12 • Removing the Shelf Bracket Kit (Optional), page C-12 Note This optional kit is not provided with the switch; to order the kit, contact your switch supplier. Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 203
of the optional shelf bracket kit. Table C-1 Quantity 2 2 20 20 Contents of Shelf Bracket Kit Part Description Support rack-mount bracket Rack-mount support brace 12-24 x 3/4-in. Phillips screws 10-32 x 3/4-in. Phillips screws OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide C-7 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 204
screws 12-24 x 3/4-in. Phillips screws 10-24 x 3/4-in. Phillips screws Required Equipment You need the following equipment for this installation: • Number 2 Phillips screwdriver • Tape measure and level (to ensure shelf brackets are level) Cisco MDS 9500 Series Hardware Installation Guide C-8 OL - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 205
mounting rail. Then attach the shelf bracket to the rack-mounting rail using a minimum of four 12-24 or 10-24 screws. Note The bottom hole of the shelf bracket should align with the bottom hole of C-1, using the 10-32 screws. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide C-9 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 206
Then attach the shelf bracket to the front rack-mounting rail using a minimum of four 12-24 or 10-24 screws. Note The bottom hole of the shelf bracket should align with the bottom hole of the level or tape measure as desired). C-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 207
. Statement 1030 Note Before you install, operate, or service the system, see the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family for important safety information. To install the switch on top of the rack-mount support brackets, follow these steps: Step 1 Step 2 Step - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 208
Cisco MDS 9000 Family Telco and EIA Shelf Bracket Appendix C Cabinet and Rack Installation Send documentation comments to [email protected]. Installing the Switch on the Shelf Brackets This section provides general instructions for installing the switch on top of the shelf brackets. For - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 209
9500 Shelf Bracket Note This kit is optional and is not provided with the switch. To order the kit, contact your switch supplier. The optional Cisco MDS 9500 Shelf Bracket Kit (DS-SHELF-9500) can be used to support the Cisco MDS 9509 Director in a nonthreaded cabinet or rack with an 18-inch (45.7 cm - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 210
Cisco MDS 9509 Director, as described in Appendix D, "Technical Specifications." This is particularly important to verify if you are installing the switch Contents of Cisco MDS 9500 Shelf Bracket Kit Quantity 2 16 12 12 Part Description Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 211
the other shelf bracket. Verify that the shelf brackets are at the same height (using the level or tape measure as desired). OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide C-15 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 212
[email protected]. Installing the Switch on the Shelf Brackets This section provides general instructions for installing the Cisco MDS 9509 service the system, see the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family for important safety information. To install the Cisco MDS - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 213
, page D-19 • SFP and SFP+ Transceiver Specifications, page D-22 Note Specifications for cables and connectors are provided in Appendix E, "Cable and Port Specifications." Switch Specifications The Cisco MDS 9500 Series supports hot-swappable fan modules that provide 85 cfm (cubic feet - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 214
for the Cisco MDS 9509 Director. Table D-3 Physical Specifications for the Cisco MDS 9509 Director Description Dimensions (HxWxD) Weight Specification 24.5 x 17.25 x 18.8 in. (62.2 x 43.8 x 47.8 cm) Chassis requires 14 RU1 plus space for shelf brackets. Chassis depth including cable guide is 21 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 215
the physical specifications for the Cisco MDS 9506 Director. Table D-4 Physical Specifications for the Cisco MDS 9506 Director Description Dimensions (HxWxD) Weight Specification 12.25 x 17.37 x 21.75 in. (31.1 x 44.1 x 55.2 cm). Chassis requires 7 RU1. Chassis depth including cable guides is 26 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 216
per minute Module Specifications Table D-5 lists the specifications for the Cisco MDS 9500 Series supervisor modules, services modules, and switching modules. Table D-5 Cisco MDS 9500 Series Module Specifications Description Specification Environmental Requirements Temperature, certified - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 217
Cisco MDS 9000 Family Module 48-port 8-Gbps switching module 24-port 8-Gbps switching module 4/44-port 8-Gbps Host-Optimized switching module Fabric 2 external crossbar module (DS-13SLT-FAB2) Fabric 1 external crossbar module (DS-13SLT-FAB1) 48-port 4-Gbps switching module 24-port 4-Gbps switching - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 218
50 lb (0.25 kg) Table D-7 lists the specifications for the batteries on the Cisco MDS 9000 Family caching services module. Note The CSM does not support Cisco SAN-OS Release 3.0(1). Table D-7 Caching Services Module Battery Specifications Attribute Value Nominal voltage 9.6 V Rated capacity - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 219
Appendix D Technical Specifications Power Specifications for the Cisco MDS 9513 Director Send documentation comments to [email protected]. • Two AC power connection @ 220 VAC = 6000 W output If a 110 VAC input is chosen, a 110-VAC power cord (CAB-7513AC=) must be ordered separately. Note - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 220
42 4/44-port 8-Gbps Host-Optimized 4.x switching module, DS-X9248-48K9 214 915 2.98 2.23 1.49 1.12 AC Power Consumption for the Cisco MDS 9513 Director Table D-10 shows the typical AC power consumption for a Cisco MDS 9513 Director. Cisco MDS 9500 Series Hardware Installation Guide D-8 OL - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 221
, DS-X9112 107 4-Port 10-Gbps switching module, DS-X9704 162 48-port 8-Gbps switching module, DS-X9248-96K9 230 24-port 8-Gbps switching module, DS-X9224-96K 221 4/44-port 8-Gbps Host-Optimized switching module, 175 DS-X9248-48K9 Power Specifications for the Cisco MDS 9509 Director This - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 222
Supply Type Voltage Current rating Frequency Output capacity Output voltage at 200/240 Specification 16 A maximum at 100 to 120 VAC and 1300-W output. 16 4000 W maximum. 3.3 V at 15 A; 5 V at 5 A; 12 V at 12 A; 42 V at 91.2 A D-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 223
Type/ Product Number Cisco MDS 9509 chassis with fan module DS-C9509 Supervisor/fabric 1 DS-X9530-SF1 Supervisor-2, DS-X9530-SF2-K9 48-port 4-Gbps switching module, DS-X9148 24-port 4-Gbps switching module, DS-X9124 12-port 4-Gbps switching module, DS-X9112 4-Port 10-Gbps switching module, DS-X9704 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 224
0.96 1.46 1.54 1.46 1.54 1.04 1.12 1.55 24-port 8-Gbps switching module, 4.x DS-X9224-96K 273 1163 3.79 2.84 1.90 1.42 4/44-port 8-Gbps Host-Optimized 4.x switching module, DS-X9248-48K9 214 915 2.98 2.23 1.49 1.12 D-12 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 225
DC Power Supply Module Type/ Product Number SAN-OS Release Cisco MDS 9509 chassis with fan module DS-C9509 3.x 2.x and 1.x Supervisor/fabric 1 DS-X9530-SF1 3.x 2.x and 1.x 32-port 1-Gbps/2-Gbps Fibre Channel module DS-X9032 3.x 2.x and 1.x 16-port 1-Gbps/2-Gbps Fibre Channel module DS-X9016 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 226
IPS module, DS-X9304-SMIP 128 48-port 8-Gbps switching module, DS-X9248-96K9 230 24-port 8-Gbps switching module, DS-X9224-96K 221 4/44-port 8-Gbps Host-Optimized switching module, 175 DS-X9248-48K9 Power Specifications for the Cisco MDS 9506 Director This section includes the following - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 227
comments to [email protected]. Specifications for the Cisco MDS 9506 Power Supplies Caution The following applies to AC power supplies on the Cisco MDS 9506 only: The DS-C9506 equipment is suitable for use on TN power systems and the IT-power system connection of Norway (max 230 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 228
Number Cisco MDS 9506 chassis with fan module DS-C9506 NX-OS Release Supervisor/fabric 1 DS-X9530-SF1 Supervisor-2, DS-X9530-SF2-K9 48-port 4-Gbps switching module, DS-X9148 24-port 4-Gbps switching module, DS-X9124 12-port 4-Gbps switching module, DS-X9112 4-Port 10-Gbps switching module - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 229
19 1.04 1.15 0.83 0.96 1.46 1.54 1.46 1.54 1.04 1.11 1.55 1.42 1.12 Table D-17 Power Requirements and Heat Dissipation for the 1900-W DC Power Supply Module Type/ Product Number SAN-OS Release Cisco MDS 9506 3.x chassis with fan module 2.x and 1.x DS-C9506 Power Required (watts) 126 126 Heat - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 230
for the Cisco MDS 9506 Director Appendix D Technical Specifications Send documentation comments to [email protected]. Table D-17 Power Requirements and Heat Dissipation for the 1900-W DC Power Supply (continued) Module Type/ Product Number SAN-OS Release Supervisor/fabric 1 DS-X9530 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 231
IPS module, DS-X9304-SMIP 128 48-port 8-Gbps switching module, DS-X9248-96K9 230 24-port 8-Gbps switching module, DS-X9224-96K 221 4/44-port 8-Gbps Host-Optimized switching module, 175 DS-X9248-48K9 X2 Transceiver Specifications The Cisco MDS 9500 Series is compatible with X2 transceivers - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 232
m (108 ft) 10.51875 300 m (984 ft) 10.51875 24.8 miles (40 km) 10.51875 6.2 miles (10 km) 10.51875 specifications for Cisco 10-Gbps Fibre Channel X2 transceivers. Table D-21 Power Requirement Specifications for Cisco 6.2 11.1 D-20 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 233
Specification for Cisco 10-Gbps Ethernet X2 Transceivers Table D-24 provides the general specifications for Cisco 10-Gbps Ethernet X2 transceivers. Table D-24 General Specifications for the Cisco above is 2 meters (6.5 feet). OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-21 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 234
-Gbps Ethernet DWDM X2 Transceiver pluggable module (DWDM-X2-xx.xx=) provides high-performance Fibre Channel connectivity for the Cisco MDS 9000 family 10-Gbps Fibre Channel switching module to an existing Ethernet DWDM infrastructure. The data format transmitted by the Ethernet DWDM X2 transceiver - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 235
Appendix D Technical Specifications SFP and SFP+ Transceiver Specifications Send documentation comments to [email protected]. Use only Cisco SFP transceivers on the Cisco MDS 9500 Series. Each Cisco SFP transceiver is encoded with model information that enables the switch to verify that - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 236
cisco.com. General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers Table D-28 provides the general specifications for Cisco Fibre Channel SFP+ transceivers. Table D-28 General Specifications for Cisco [OM3] D-24 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 237
Table D-30 provides the environment specification for the Cisco 8-Gbps Fibre Channel SFP+ transceivers. Table D-30 Environmental Specifications for Cisco 8-Gbps Fibre Channel SFP+ Safety Information for the Cisco MDS 9000 Family. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-25 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 238
cisco.com. General Specifications for Cisco 4-Gbps Fibre Channel SFP Transceivers Table D-31 provides the general specifications for Cisco Fibre Channel SFP transceivers. Table D-31 General Specifications for Cisco OM3) 4.8 7.8 D-26 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 239
Information for the Cisco MDS 9000 Family. General Specifications for Cisco 2-Gbps Fibre Channel SFP Transceivers Table D-34 provides general specification for the Loss Budget (dBm) 2.1 (62.5 micron), 2.62 (50 micron -OM2) 7.8 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-27 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 240
1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel-LW SFP, Long wavelength LC 1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel-SW SFP, Short wavelength LC D-28 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 241
power requirement specification for Cisco Fibre Channel and Gigabit Ethernet SFP transceivers. Table D-40 Power Requirement Specification for Cisco Fibre Channel (GE - 62.5 micron), 3.37 (FC - 50.0 micron) 7.8 (FC) 4.57 (GE) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-29 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 242
SFP 1570 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Cisco CWDM SFP 1590 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Cisco CWDM SFP 1610 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Color Gray Violet Blue Green Yellow Orange Red Brown D-30 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 243
Cisco 2-Gbps CWDM SFP transceivers. Table D-44 Environmental Specifications for Cisco 2-Gbps CWDM SFP Transceivers SFP All Cisco 2-Gbps CWDM SFP Transceivers Operating Maximum 40°C Minimum 0°C Storage Maximum 85°C Minimum -40°C OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 244
the link to avoid overloading the receiver. For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family. D-32 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 245
single-mode fiber are used, it is necessary to insert an in-line optical attenuator in the link to avoid overloading the receiver. • A maximum of 24 4-Gbps CWDM SFPs are supported in a single MDS switching module. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-33 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 246
DS-SFP-GE-T is not supported on Cisco MDS 9222. General Specifications for Cisco Gigabit Ethernet Transceivers Table D-49 provides the general specification for the Cisco Gigabit Ethernet SFP transceiver. Table D-49 General Specification for the Cisco Gigabit Ethernet SFP Transceivers SFP DS - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 247
Cisco MDS 9000 family switching module supports up to eight 2-Gbps DWDM SFPs. For more information, refer to the data sheet at: http://www.cisco.com/en/US/prod/collateral/modules/ps5455/ps6576/product_data_sheet0900aecd805 82763.html. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 248
SFP and SFP+ Transceiver Specifications Appendix D Technical Specifications Send documentation comments to [email protected]. D-36 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 249
service representative. Note If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you purchased support directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtm OL-17467-02 Cisco MDS - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 250
or the DB-9F/RJ-45F PC terminal adapter to connect the console port to a computer running terminal emulation software. Console Port Pinouts Table E-1 lists the pinouts for the console port on the Cisco MDS 9500 Series. Table E-1 Console Port Pinouts Pin Signal 11 RTS 2 DTR 3 TxD 4 GND - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 251
. The COM1 port can be connected to a modem using the cable and adapters provided in the accessory kit. COM1 Port Pinouts Table E-4 lists the pinouts for the COM1 port on the Cisco MDS 9500 Series. Note Additional cables and adapters can be ordered from your customer service representative. Table - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 252
can use a modular, RJ-45, straight-through UTP cable to connect the management port to an external hub, switch, or router (see Figure E-1). Figure E-1 RJ-45 Interface Cable Connector RJ-45 (both ends) 12 1 Pin 1 2 Pin 8 Cisco MDS 9500 Series Hardware Installation Guide E-4 94971 OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 253
to connect the management port to a switch or hub (not provided with the switch). Figure E-2 Twisted-Pair 10/100/1000BASE-T Cable Schematic MGMT 10/100 1 TXD+ 2 TXD3 RXD+ 6 RXD- Switch/Hub 1 RXD+ 2 RXD3 TXD+ 6 TXD- 4 NC 5 NC 7 NC 8 NC 4 NC 5 NC 7 NC 8 NC 99343 OL-17467-02 Cisco MDS 9500 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 254
and Port Specifications Send documentation comments to [email protected]. MGMT 10/100 Ethernet Port The MGMT 10/100 Ethernet port is an Ethernet port with an RJ-45 connector. You can use a modular, RJ-45, straight-through UTP cable to connect the management port to an external hub, switch - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 255
Appendix E Cable and Port Specifications Supported Power Cords and Plugs Send documentation comments to [email protected]. Figure E-4 shows a schematic of the 10/100BASE-T cable required to connect the management port to a switch or hub (not provided with the switch). Figure E-4 Twisted - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 256
Supported Power Cords and Plugs Appendix E Cable and Port Specifications Send documentation comments to [email protected]. Table E-8 Power Cords for the MDS 9500 Series Switches 7/7 Plug, EU 13.12 4 Power Cord, 250VAC Cisco MDS 9500 Series Hardware Installation Guide E-8 OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 257
Port Specifications Supported Power Cords and Plugs Send documentation comments to [email protected]. Supported Plugs for 6000-W AC, 2500-W AC, and 1900-W AC Power Supplies Figure E-5 shows the supported SABS 164-1 (16 A) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide E-9 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 258
E-7 at 110 VAC results in 1300 W available to the system. Figure E-7 Additional Power Supply Plug Supported for 3000-W and 2500-W 110 VAC Only 113168 1 NEMA 5-20P North American power cord product ID: CAB-7513AC 110 VAC (20 A) E-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 259
Port Specifications Supported Power Cords and Plugs Send documentation comments to [email protected]. Supported Plugs for the 4000-W AC Power Supply Figure E-8 shows the supported cord for the Cisco MDS 9500 Series. The C19 connector plugs into the C20 inlet on the Cisco MDS 9500 Series - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 260
VAC Power Cord Reference Illustration Figure E-10 16 A, 250 VAC 16 A, 250 VAC 16 A, 250 VAC 16 A 250 VAC 16 A 250 VAC Figure E-11 Figure E-12 Figure E-13 Figure E-14 Figure E-15 16 A 250 VAC Figure E-16 E-12 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 261
Appendix E Cable and Port Specifications Supported Power Cords and Plugs Send documentation comments to [email protected]. AC Power Cord Illustrations This section 0 in. (4.26 m) Connector: IEC 60320 C19 113363 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide E-13 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 262
Supported Power Cords and Plugs Appendix E Cable and Port Specifications Send documentation comments to [email protected]. Figure E-12 CAB-9K16A-AUS Plug: AU20S3 Cordset in. (2.5 m) Connector: IEC 60320 C19 113364 E-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 263
Appendix E Cable and Port Specifications Supported Power Cords and Plugs Send documentation comments to [email protected]. Figure E-15 CAB-9K16A-EU 113348 Plug: CEE 7/7 Cordset rating: 16 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC 60320 C15 Figure E-16 CAB-C19-CBN - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 264
Supported Power Cords and Plugs Appendix E Cable and Port Specifications Send documentation comments to [email protected]. E-16 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 265
Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. Contacting Customer Service If you are unable to solve a startup problem after using the troubleshooting suggestions in this appendix, contact your customer service representative for assistance and further instructions - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 266
the show sprom backplane 1 command to display the backplane contents, including the switch serial number. Figure F-1 shows the location of the serial number label on the Cisco MDS 9513 Director. Figure F-1 Serial Number Location on Cisco MDS 9513 Director Cisco 11 character label SN: XXXNNNNXXXX - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 267
Appendix F Site Planning and Maintenance Records Contacting Customer Service Send documentation comments to [email protected]. Figure F-2 Serial Number Location on Cisco MDS 9509 Director 113305 SN: AAANNNNXXXX The Cisco MDS 9506 Director chassis serial number label is shown in Figure - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 268
on page D-6, the "Power Specifications for the Cisco MDS 9509 Director" section on page D-9, and the "Power Specifications for the Cisco MDS 9506 Director" section on page D-14 for power and heat ratings. Table F-1 Site Planning Checklist Task No. Planning Activity Verified By Time Date - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 269
documentation comments to [email protected]. Table F-1 Site Planning Checklist (continued) Task No. Planning Activity Verified By Time Date 5 EMI = electromagnetic interference 4. RFI = radio frequency interference OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide F-5 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 270
F Site Planning and Maintenance Records Send documentation comments to [email protected]. Contact and Site Information Use the following worksheet (Figure F-3) (line 1) Address (line 2) City State Zip code Country Cisco MDS 9500 Series Hardware Installation Guide F-6 OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 271
address Switch IP netmask Host name Domain name IP broadcast address Gateway/router address DNS address Modem telephone number Table F-4 Module Information Slot Module Type 1 Module Serial Number 2 3 4 5 Supervisor Notes OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 272
comments to [email protected]. Table F-4 Module Information (continued) Slot Module Type 6 Supervisor 7 Module Serial Number Notes 8 9 Note Slots 7, 8, and 9 are only available in the Cisco MDS 9509 Director. Cisco MDS 9500 Series Hardware Installation Guide F-8 OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 273
comments to [email protected]. INDEX Numerics 12-port 4-Gbps Fibre Channel switching modules description 1-35 figure 1-35 14/2-port Multiprotocol Services module. See MPS-14/2 16-port switching modules description 1-38 figure 1-38 LEDs (table) 1-37, 1-40 24-port 4-Gbps Fibre Channel - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 274
IN-2 Cisco MDS 9500 Series Hardware Installation Guide description 1-3 features 1-3 figure 1-4, 1-5 installing in a rack (procedure) 2-7 power supplies 1-10, 2-7, 2-28 preinstallation 2-2 serial number location F-2 Cisco MDS 9500 Series Multilayer Directors description 1-1 Cisco MDS Fabric Switch - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 275
port B-7 console port cabling E-2 connecting B-2 pinouts E-2 contact and site information F-6 crossbar fan modules description 1-16 crossbar modules Cisco MDS 9513 support 1-25 description 1-25 installing 2-48 location 1-25 removing 2-47, A-5 supervisor association 1-25 crossbar switching fabric - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 276
2-3 power supplies (Cisco MDS 9513 Director 2-54 power supplies (MDS 9509 Director) 2-57, 2-62 rack mount brackets C-11 rack-mounting guidelines C-7 services modules 2-38 SFP transceiver cables B-15 SFP transceivers (note) B-13 shelf brackets C-12 supervisor modules 2-38, 2-40 switching modules 2-38 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 277
and Installing MDS 9000 24-port or 48-port 8-Gbps Modules A-9 Installing MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x A-5 Installing the MDS 9000 4/44-Port 8-Gbps Host-Optimized Module A-3 Installing the MDS 9513 Fabric 2 Modules and Activating Higher Bandwidth by Reloading the Switch A-10 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 278
starting up the switch 2-28 supported plugs E-7 IN-6 Cisco MDS 9500 Series Hardware Installation Guide power supplies (Cisco MDS 9506 Director) removing and installing PEMs 2-64 specifications D-14 power supplies (Cisco MDS 9509 Director) specifications D-6, D-9 power supplies (MDS 9506 Director - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 279
/Gigabit Ethernet 1-56 Fibre Channel/Gigabit Ethernet supported D-28 Fibre Channel specifications D-23 Fibre Channel supported D-23 Gigabit Ethernet 1-56 installing B-14 latches supported B-12 OL-17467-02 removing B-12 shelf bracket Cisco MDS 9500, installation C-13 installing Telco/EIA C-6 shelf - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 280
grounding 2-17 T Telco racks (requirements) C-6 transceivers description 1-55 supported SFP transceivers 1-55 supported X2 transceiver 1-55 troubleshooting contacting customer service F-1 W weight of modules D-5 X X2 transceivers IN-8 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 281
comments to [email protected]. description 1-55, D-19 installing B-11 removing B-11 supported (table) D-20 Numerics 12-port 4-Gbps Fibre Channel switching modules description 36 figure 37 14/2-port Multiprotocol Services module. See MPS-14/2 16-port switching modules description 39 figure - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 282
10/100/1000 6 console port cabling 2 connecting 2 pinouts 2 contact and site information 6 crossbar fan modules description 16 crossbar modules Cisco MDS 9513 support 25 description 25 installing 48 location 25 removing 47, 5 supervisor association 25 crossbar switching fabric description 22 dual - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 283
16 Fibre Channel ports connecting 9 connecting with LC-type cables (figure) 15 Fibre Channel/Gigabit Ethernet SFP transceivers 57 G Genaration 3 Modules Installing the MDS 9000 4/44-Port 8-Gbps Host-Optimized Module 3 Generation 1 modules services modules 42 switching modules 33 Generation - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 284
Installing MDS 9000 24-port or 48-port 8-Gbps Modules 9 Installing MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x 5 Installing the MDS 9000 4/44-Port 8-Gbps Host-Optimized Module 3 Installing the MDS 9513 Fabric 2 Modules and Activating Higher Bandwidth by Reloading the Switch 10 Migration - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 285
up the switch 28 supported plugs 7 power supplies (Cisco MDS 9506 Director) removing and installing PEMs 64 specifications 14 power supplies (Cisco MDS 9509 Director) specifications 6, 9 power supplies (MDS 9506 Director) description 15 power supplies (MDS 9509 Director) description 12 powering up - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 286
17 integrated crossbar switching fabric 17 LEDs 19 LEDs (figure) 19 LEDs (table) 20 LEDs description 19 memory options 18 nondisruptive restart 18 port interfaces 18 processor 18 redundant central arbiter 18 warm switchover 18 IN-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 287
description 56 supported SFP transceivers 56 supported X2 transceiver 56 troubleshooting contacting customer service 1 W weight of modules 5 X X2 transceivers description 56, 19 installing 11 removing 11 supported (table) 20 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide IN-15 - HP Cisco MDS 9134 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 288
Index Send documentation comments to [email protected]. IN-16 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02
Send documentation comments to [email protected].
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Cisco MDS 9500 Series Hardware
Installation Guide
October 2008
Text Part Number: OL-17467-02