HP Cisco MDS 9216 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Rel - Page 44
Open Caveats, Symptom, Workaround, CSCsg49151
View all HP Cisco MDS 9216 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Caveats Send documentation comments to [email protected] • CSCsu48426 Symptom: For a data stream that has a lot of variance in the compression ratio across individual tape blocks on the tape, SME restore performance for the HP LTO drives is substantially affected. However, backup performance is not affected. Workaround: This issue is resolved. • CSCsu68490 Symptom: A downgrade from NX-OS 4.1(1b) to SAN-OS 3.1(1) is not supported If there are FC-Redirect configurations and any of the following conditions are true: - FC-Redirect configuration exists for a locally connected target and if there are ISLs configured on a Generation 2module. - FC-Redirect Configuration exists for a locally connected host and if the host is connected to a Generation 2module. Downgrading in such cases might lead to traffic disruption and/or data corruption. Workaround: This issue is resolved. • CSCsu90955 Symptom: In a dual FCIP link configuration with one of the ports is shutdown, the performance of the other still enabled active FCIP link degrades significantly (from ~12 Mb/sec to 1Mb/sec). Workaround: This issue is resolved. • CSCsm32705 Symptom: Disabling Fabric Manager e-mails for Call Home on a port flap event through the server properties is not allowed. Workaround: This issue is resolved. • CSCso31469 Symptom: RMON can not be used to monitor objects for a group of ports of the same type. Workaround: This issue is resolved. • CSCsr42622 Symptom: The TSM catalog backup fails due to a limitation in SME where all tape blocks are expected to be 16-byte aligned. This issue has also been observed as part of the TSM Export Node process due to the same reason. Workaround: None Open Caveats • CSCsc17059 Symptom: In rare circumstances, after upgrading the SAN-OS, a Generation 1 module may be rebooted as it stops responding to the keep alive messages from the Supervisor module. Workaround: None. • CSCsg49151 Symptom: If you bring up more than one link at a time between two VSANs that have overlapping domains and at least one of the switches is SDV enabled, one link will become isolated. The other links will come up, even though the domains are overlapping. In addition, the SDV virtual domains will change, causing traffic disruption on all devices associated with their old value. Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2) 44 OL-14116-10