HP LC2000r HP Netserver LXr 8500 NetRAID-3Si Config. Guide for Windows NT4.0 - Page 2
Storage
View all HP LC2000r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Operating System Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition SP6a or later HP NetServer LXr 8500 550, 700 MHz 2 - 8 ASPN Release 8 Any size 128 MB minimum. Must be HP. 3 required for redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, PCI-1, PCI-2, SCSI A, SCSI B, PCI-3, PCI-4, PCI-5 through PCI-10 P3 - Intra-cluster (Heartbeat) LAN - D5013B P4 - Client LAN - D5013B P5 - Local storage- NetRAID-1Si P6 - Shared storage -NetRAID-3Si Booted from NetRAID-1Si Local Controller Driver Physical drive location Disk drives SCSI bus SCSI Ids Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI ID Channels RAID level Logical disks Configuration options: May use embedded SCSI, NetRAID-1Si or NetRAID-3Si. For embedded SCSI, use sym_hi.sys version 4.12 or later. For NetRAID-xSi, use mraidnt.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 Mraidnt.sys 2.24 A.01.15 or later 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array Cluster mode on Cache write-policy to write-thru 2