Operating System Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition SP6a or later HP NetServer LXr 8500 550, 700 MHz 2 - 8 ASPN Release 8 Any size 128 MB minimum. Must be HP. 3 required for redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, PCI-1, PCI-2, SCSI A, SCSI B, PCI-3, PCI-4, PCI-5 through PCI-10 P3 - Intra-cluster (Heartbeat) LAN - D5013B P4 - Client LAN - D5013B P5 - Local storage- NetRAID-1Si P6 - Shared storage -NetRAID-3Si Booted from NetRAID-1Si Local Controller Driver Physical drive location Disk drives SCSI bus SCSI Ids Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI ID Channels RAID level Logical disks Configuration options: May use embedded SCSI, NetRAID-1Si or NetRAID-3Si. For embedded SCSI, use sym_hi.sys version 4.12 or later. For NetRAID-xSi, use mraidnt.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 Mraidnt.sys 2.24 A.01.15 or later 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array Cluster mode on Cache write-policy to write-thru 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

2
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition
Service pack
SP6a or later
SPU
Model
HP NetServer LXr 8500
Clock speed
550, 700 MHz
No. of CPUs
2 – 8
BIOS version
ASPN Release 8
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
3 required for redundancy
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, PCI-1, PCI-2, SCSI A, SCSI B, PCI-3, PCI-4, PCI-5 through
PCI-10
M/S Certified
Configuration
P3 – Intra-cluster (Heartbeat) LAN -
D5013B
P4 – Client LAN - D5013B
P5 – Local storage- NetRAID-1Si
P6 – Shared storage –NetRAID-3Si
Booted from NetRAID-1Si
Storage
Local
Controller
May use embedded SCSI, NetRAID-1Si or NetRAID-3Si.
Driver
For embedded SCSI, use sym_hi.sys version 4.12 or later.
For NetRAID-xSi, use mraidnt.sys version 2.24.
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
SCSI Ids
Any
Shared
Controller
Model
HP NetRAID-3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.30
BIOS
B.02.02
Driver
Mraidnt.sys 2.24
NetRAID Assistant
A.01.15 or later
SCSI ID
6, 7
Channels
0, 1, 2
RAID level
1, 5, 10, 50
Logical disks
1 per RAID array
Configuration
options:
Cluster mode on
Cache write-policy to write-thru