HP LH3000r HP Netserver LH 3000 FC Config Guide for Windows NT4.0 Clusters - Page 2

Storage - lh3000

Page 2 highlights

Navigator version Operating System SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage L.18.02 or later Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack SP6A or later HP NetServer LH3000 733, 800, 933 MHz 2 4.06.24 PT or later Any size 128 MB minimum. Must be HP. 2 required, 3 for redundancy, 4 for power cord redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8, PCI-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1 P5 - Local Storage (NetRAID-1Si) P6 - Client LAN P8 - Shared Storage HBA Booted from embedded DAC Local Controller Driver Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May use embedded SCSI, embedded DAC, NetRAID-3Si or NetRAID-1Si. For embedded SCSI, use sym_hi.sys version 4.12 or later. For embedded DAC and NetRAID-xSi, use mraidnt.sys version 2.24 SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver RAID level Cabinet RAID arrays No. of cabinets Required - D5991A HP Fibre Channel Host Bus Adapter - D8602A 1 Hhba5100.sys 1.12 or later 0, 1,3, 5 Not more than 8 physical drives per logical array and not more than 8 LUNs are permitted per Rack Storage/12FC and Rack Storage/12 combination in a cluster. 1 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
Navigator version
L.18.02 or later
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack
SP6A or later
SPU
Model
HP NetServer LH3000
Clock speed
733, 800, 933 MHz
No. of CPUs
2
BIOS version
4.06.24 PT or later
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
2 required, 3 for redundancy, 4 for power cord redundancy
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind
the server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8,
PCI-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
M/S Certified
Configuration
P5 – Local Storage (NetRAID-1Si)
P6 -
Client LAN
P8 - Shared Storage HBA
Booted from embedded
DAC
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-3Si or
NetRAID-1Si.
Driver
For embedded SCSI, use sym_hi.sys
version 4.12 or later.
For
embedded DAC and NetRAID-xSi, use mraidnt.sys version 2.24
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
Required
– D5991A
Host Bus Adapter
Model
HP Fibre Channel Host Bus Adapter - D8602A
No. of HBAs
1
Driver
Hhba5100.sys 1.12 or later
RAID level
0, 1,3, 5
Cabinet
RAID arrays
Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets
1