HP LH3000r HP Netserver LPr Quick Service Guide - Page 12

Specifications

Page 12 highlights

System Switches System Switches Default Settings CPU Frequency (MHz) 350 400 450 500 550 Off On Off On Off On Off On Off On On Off Must Be OFF (7 & 8) On = Clear Password (6) On = Clear Config (5) On Off On Off Specifications Temperature Operating Non-operating 5°to 35°C (41°to 95°F) -40° to +65° C (-40° to +149° F) Humidity (non-condensing) Operating Non-operating 20% to 80% relative humidity, non-condensing 5% to 95% relative humidity, non-condensing Altitude Operating Non-operating -30 to 3,000 m (~ 10,000 ft) -30 to 12,000 m (~ 40,000 ft) Thermal Output Maximum Operating 1041 BTU/hr Minimum Clearance No requirement in HP racks. Weight and Dimensions Weight Width Depth Height Approx. 40 lbs (88 kg)., depending on configuration 17.6 inches (44.7 cm) 28 inches (71.1cm) 3.5 inches (8.9 cm) Power Supply Specifications Type Input - Max. ROapnegraeting Current In-rush Current Operating Power Auto-ranging 88 to 140 VAC at 47 - 63 Hz 100 VAC: 5.3 120 VAC: 4.6 A 200/208 VAC: 3.2 A 220/230 VAC: 2.8 A 25 A 305 W 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

10
System Switches
CPU Frequency (MHz)
System Switches Default Settings
350
400
450
Must Be OFF (7 & 8)
On = Clear Password (6)
On = Clear Config (5)
Off
Off
Off
Off
On
On
On
On
500
550
Off
On
Off
On
Off
On
Off
On
Specifications
Temperature
Operating
5
°
to 35
°
C (41
°
to 95
°
F)
Non-operating
-40° to +65° C (-40° to +149° F)
Humidity (non-condensing)
Operating
20% to 80% relative humidity, non-condensing
Non-operating
5% to 95% relative humidity, non-condensing
Altitude
Operating
-30 to 3,000 m (~ 10,000 ft)
Non-operating
-30 to 12,000 m (~ 40,000 ft)
Thermal Output
Maximum Operating
1041 BTU/hr
Minimum Clearance
No requirement in HP racks.
Weight and Dimensions
Weight
Approx. 40 lbs (88 kg)., depending on configuration
Width
17.6 inches (44.7 cm)
Depth
28 inches (71.1cm)
Height
3.5 inches (8.9 cm)
Power Supply Specifications
Type
Auto-ranging
Input - Max.
Range
88 to 140 VAC at 47 - 63 Hz
Operating Current
100 VAC:
5.3
120 VAC:
4.6 A
200/208 VAC:
3.2 A
220/230 VAC:
2.8 A
In-rush Current
25 A
Operating Power
305 W