HP LH4r HP Netserver LXr Pro8 Memory Board

HP LH4r - NetServer - 256 MB RAM Manual

HP LH4r manual content summary:

  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 1
    HP NetServer LXr Pro8 4 GB Memory Board Installation Guide HP Part Number 5967-2103 Printed in January 1998
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 2
    protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Hewlett-Packard Company. Hewlett-Packard Company Network Server Division Technical Marketing/MS 53U-FJ 5301 Stevens Creek
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 3
    MB SDRAM DIMM Module 18 Installing the 4 GB Memory Board 19 Power-Up Procedure 22 3 Troubleshooting 25 Diagnostics Overview 25 The BIOS POST Test 25 ECC Single-Bit and Multiple-Bit Errors 26 Troubleshooting Resources 27 4 Service and Support 29 U.S. and Canada 29 Europe...30 Asia/Pacific
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 4
    6 Specifications 37 7 Regulatory Information 39 Index ...41 iv
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 5
    an HP NetServer LXr Pro8. Contents of this Guide This guide includes the following topics: • Installation instructions • Troubleshooting information, from common installation problems to special steps that may help you identify and interpret errors and/or failures • International service and support
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 6
    Preface Related Documentation The following documents describe the HP NetServer LXr Pro8: • The HP NetServer LXr Pro8 User Guide • The Product and Service Reference Labels • Information Assistant on the HP NetServer Navigator CD-ROM 2
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 7
    . The contents of the shipping box should include: • The 4 GB memory board • The anti-static container in which the 4 GB memory board is packaged • The HP NetServer LXr Pro8 4 GB Memory Board Installation Guide CAUTION Whenever you handle the 4 GB memory board, you should do so in an anti-static
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 8
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 9
    MB SDRAM DIMMs and downsizing the memory configuration • Installing the 4 GB memory board • Powering up the system Installation Basics The HP NetServer LXr Pro8 accepts up to two memory boards. Each board has 32 DIMM sockets and accepts only 128 MB SDRAM DIMMS, for a maximum capacity of 4096 MB per
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 10
    M0 to M31 as shown in Figure 2-1. • The recommended memory configurations and the slot numbers where SDRAM DIMMs are installed are . Figure 2-1 shows the DIMM slot numbers on the 4 GB Memory Board. Board jumpers are preset to the memory board revision level. M0 M4 M8 M12 M16 M20 M24 M28 Figure
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 11
    XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX Figure 2-2. Memory Configurations for One 4 GB Memory Board Memory Upper Memory Board Slots M0 - M31 Size Quan- tity 0 4 XXXX XXXX 8 GB 32 XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX Memory Lower Memory Board Slots M0 - M31 Size Quan- tity 0 4 8 12
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 12
    must be turned off before removing or installing the 4 GB memory boards. 1. Save your existing system configuration. 2. Log off all users, shut down all networking software, applications, and the operating system. 3. Press the DC power switch on the HP NetServer's control panel (Figure 2-4). 8
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 13
    2 Power AC Power LED LED Installing Memory in the 4 GB Memory Board DC Power Switch Figure 2-4. HP NetServer Control Panel 4. Unlock the power interlock switch at the back of the HP NetServer's rear panel by turning it clockwise (Figure 2-5). The switch turns off DC power to the HP NetServer, and
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 14
    Unlocked Figure 2-5. Power Interlock Switch, NetServer Rear Panel Accessing the Lower Board Cage The lower board cage holds the NetServer's memory boards. To reach these boards, you extend the satellite chassis and remove the lower fan module and rear access panel. NOTE If the server is mounted
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 15
    the HP NetServer and grasp the two ejector handles on the HP NetServer's rear panel. Pull both handles down firmly, and then pull the satellite toward you. Pull it out until its slides are fully extended. The slides lock in the extended position, so that the satellite cannot move while you service
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 16
    Memory in the 4 GB Memory Board Ejector Handles Figure 2-7. Sliding Out the Satellite Chassis 2. Remove the lower fan module, as shown in Figure 2-8: a. Grasp the handles on either end of the fan module and push them toward each other. b. While continuing to push on the handles, pull the fan
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 17
    Chapter 2 Installing Memory in the 4 GB Memory Board Base Chassis Satellite Chassis Handles Lower Fan Module Figure 2-8. Removing the Lower Fan Module 3. Remove the NetServer's rear access panel, as shown in Figure 2-9: a. Loosen the three captive screws that fix the panel in place. b. Lift
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 18
    Chapter 2 Installing Memory in the 4 GB Memory Board Captive Screws Rear Access Panel Figure 2-9. Removing the Rear Access Panel 14
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 19
    2 Installing Memory in the 4 GB Memory Board Removing the Existing 4 GB Memory Board The HP NetServer has one 4 GB memory board installed. Follow these steps to remove the existing memory board for a memory upgrade: 1. After removing the rear access panel, locate the existing 4 GB memory board
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 20
    Use only 128 SDRAM DIMMs acquired from HP. Contact HP Customer Support for a list of qualified 128 MB SDRAM DIMMs. HP will not support configurations that use non-HP SDRAM DIMMs. 1. If you are installing a new memory board, remove the 4 GB memory board from its anti-static container. 2. With
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 21
    Chapter 2 Installing Memory in the 4 GB Memory Board 4. Locate the slot where you will install the 128 SDRAM DIMM, and spread the two DIMM retaining clips outward. (Figure 6. Hold the SDRAM DIMM so that the front edge faces straight down into the connector (at a 90° angle to the memory board). 17
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 22
    installed in specific DIMM slots for each memory configuration. You must remove SDRAM DIMMs so that the remaining memory is installed in the correct DIMM slots. Follow these steps to remove 128 MB SDRAM DIMMs from the 4 GB memory board: 1. Power down the satellite chassis. (See Power Down Procedure
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 23
    DIMMs and reinstall in new slots to match the DIMM slot configuration for the downsized memory. (See Figure 2-2.) CAUTION Close all retaining clips on the 4 GB memory board before inserting it into your NetServer. This includes clips on empty slots as well as those on slots containing DIMMs. This
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 24
    close the retaining latches on the front of the memory board to seat it snugly (Figure 2-13). Base Chassis Satellite Chassis Memory Board Slots Retaining Clips 4 GB Memory Board Figure 2-13. 4 GB Memory Board Installation 4. Install the second memory board in the lower slot. Verify that both
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 25
    fan's mounting rails. b. Push the fan module onto the mounting rails until it clicks into place. 7. Reattach the satellite chassis to the base chassis: a. When you finish servicing the HP NetServer, move to the front of the server and unlatch all four power supplies the satellite partly onto the
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 26
    Chapter 2 Installing Memory in the 4 GB Memory Board d. power up. Ensure the indicator lights come up correctly. See "Power Supply Indicators" in the HP NetServer LXr Pro8 User Guide. NOTE The interlock switch locks the satellite chassis in place. As a safety precaution, the server cannot power
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 27
    Chapter 2 Installing Memory in the 4 GB Memory Board The HP NetServer cannot start unless the Power Interlock Switch is in this position Figure 2-15. Power Interlock Switch, HP NetServer Rear Panel 4. Turn on the monitor. 23
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 28
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 29
    a troubleshooting solution if problems occur. The memory controller corrects POST Test During the POST (Power-On Self-Test), the BIOS checks memory to ensure that all DIMMs are  part of the NetServer Utilities package on the HP NetServer Navigator CD-ROM. If you have booted from the HP Navigator
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 30
    DIMM sizes. HP will not support DIMMs of varying sizes. If these are mixed in a single bank, the system continues to run, and memory downsizing occurs. ECC Single-bit errors, which are divided into two types. The memory controller corrects "soft" single-bit errors without any effect on the system.
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 31
    contact your support representative for additional assistance to isolate the problem. Troubleshooting Resources If you are having problems installing your 4 GB Memory board, a number of different tools help to troubleshoot the problem: • HP NetServer LXr Pro8 User Guide • HP NetServer Navigator CD
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 32
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 33
    for this Hewlett-Packard product may not be currently available in all countries listed below. U.S. and Canada For hardware repair or telephone support in the U.S. and Canada, contact either: • Participating Service Authorized HP Personal Computer Reseller or • HP Customer Support Center (Colorado
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 34
    Europe For hardware repair or telephone support in Europe, contact either: • Participating Service Authorized HP Personal Computer Reseller or • HP Customer Support Center (Netherlands) for the following countries: Austria: Belgium (Dutch): Belgium (French): Denmark: Finland: France: Germany
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 35
    Chapter 4 Service and Support Asia/Pacific For hardware service and telephone support, contact either: • A participating Reseller or • HP Customer Support Center: Australia: China: Hong Kong: India: Indonesia: Japan: Korea: Malaysia: New Zealand: Philippines: Singapore: Taiwan: Thailand: +61 (03
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 36
    Guide (CFG), are also available in Information Assistant on the HP NetServer Navigator CD-ROM. NOTE Please note that sales and support for this Hewlett-Packard product may not be currently available in all countries listed below. Telephone Ordering Information U.S. • To identify a part or manual
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 37
    , check your local telephone directory for the HP Sales and Service Office near you. If you cannot locate an HP office, contact one of the Worldwide HP Marketing Headquarters listed here: NOTE Please note that sales and support for this Hewlett-Packard product may not be currently available in all
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 38
    Chapter 4 Service and Support Joining CompuServe To open a CompuServe account or to obtain contact CompuServe directly. Mention "Representative 133" to receive a free introductory membership with a free usage credit. CompuServe P.O. Box 20212 Columbus, Ohio 43220 USA (1 800) 524-3388 Direct:
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 39
    for any part that HP asks to be returned. The customer may be required to run HP-supplied configuration and diagnostic programs before a replacement will be dispatched or an on-site visit is authorized. Refer to the warranty statement provided with your original HP NetServer system documentation
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 40
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 41
    6 Specifications Electrical Power Budget Components are powered at +3.3 and +5 volts. Power Dissipation +3.3 V 77.6 W +5.0 V 10 W Environmental Environment Temperature Non-operating Operating Humidity Non-operating Operating Altitude Non-operating Operating Specification -40° C to 70° C 5° C
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 42
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 43
    : Hewlett-Packard Company Manufacturer's Address: 5301 Stevens Creek Blvd. Santa Clara, CA 95052 USA declares, that the product Product Name: Network Server Model Number(s): Product Options: HP NetServer LXr Pro8 and LXr Pro8 CTO mod 0 All conforms to the following Product Specifications
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 44
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 45
    , 34 from Hewlett-Packard, 33 I Installing SDRAM DIMMs, 16 Installing the Memory Board, 19 L LXr Pro8 NetServer systems, 1 M Memory capacity, 1 Mixing DIMM sizes and speeds, 26 R Readme File, 3 Removing a 128 MB SDRAM DIMM Module, 18 S Standard BIOS Errors, 26 T Troubleshooting Diagnostics Overview
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

HP NetServer LXr Pro8
4 GB Memory Board
Installation Guide
HP Part Number 5967-2103
Printed in January 1998