HP LH6000r HP Netserver LP 1000r FC Windows 2000 Config Guide for Windows 200 - Page 2
Storage
View all HP LH6000r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Power source System software: Navigator version Operating System Service Pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage Microsoft® and HP Certified Configuration Direct from power mains, power conditioner or uninterruptible power supply (UPS) using any power conditioner or UPS. L.20.00 or later Microsoft Windows 2000® Advanced Server SP1 or later HP NetServer LP1000r 1 GHz 2 4.06.12 or later Any size 256 MB minimum. Must be HP. See Local Storage below. P1 - Shared Storage FC HBA (D8602A) Booted from Embedded SCSI Storage Local Controller Driver Cabinets (Physical drive location) Disk drives SCSI bus SCSI Ids Embedded SCSI SYM_U3.SYS Version 5.07.00 or later (Navigator L.20.00 or later). SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed). Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Required - D5991A Host Bus Adapter Model No. of controllers Driver RAID level Cabinet RAID arrays No. of cabinets FC Array Cards Model No. of cards/cabinet HP Fibre Channel Host Bus Adapter - HP D8602A 1 HP D8602A - Hhba5100.sys Version 2.06 0, 1, 3, 5, 10 For SPOFless configurations a fault tolerant RAID type, e.g. RAID 5, is recommended for all shared storage. HP Rack Storage 12/FC - D5991A Not more than 8 physical drives per logical array and not more than 8 LUNs are permitted per cluster. 1 HP Fibre Channel Array Controller - D5990A 2 (Requires second card be installed in the Rack Storage/12FC.) 2