HP Model 725/75 System Configuration Repository User's Reference: HP-UX/HP 90 - Page 45
EXTERNAL INFLUENCE, Formats, Environment Variable
View all HP Model 725/75 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
SCR Reference (man Pages) scrconfig (1M) - Formats Formats -t [timeout | off] If timeout is not specified, list the default data collection timeout value. If timeout is specified, set the data collection timeout value to the specified value. If the keyword off is specified, no timeout will occur. The timeout format is a numeric value in the range 1 to 99 with a suffix of h(our) or m(inute). The initial value is 15m (fifteen minutes). The data collection unit is based on the MIF component. If the execution time to collect configuration data exceeds the timeout value, the data collection is canceled. If the -n option with node name is provided with the -s option, list or set the timeout value of the specified node. If configuration parameters or managed nodes are modified, some of the following messages are output. "node" is registered as a managed node. Default parameters are applied: Schedule time: MM/DD/YYYY hh:mm tz Interval: n days Expiration period: n months Collection timeout: n minutes "node" is removed from the managed node list. Default parameter is set to: Expiration period: off Parameter for "node" is set to: Schedule time: off EXTERNAL INFLUENCE Environment Variable TZ TZ determines the conversion between the system time in UTC and the time in the user's local time zone. See environ (5) and tztab (4). Reference 45