HP Neoware e140 HP TeemTalk Terminal Emulator 7.0 User Manual - Page 281

Enhance, Answerback, Answerback concealed, Answerback mode, Send ACK

Page 281 highlights

Wyse Emulations column. The default bell column number is 72 in 80 column mode and 124 in 132 column mode. Enhance Factory default: Checked When this option is checked, TeemTalk will recognize an additional set of Wyse codes which are not normally supported by specific non-Wyse terminals. Answerback Factory default: Unspecified This enables you to specify the Answerback string that is sent to the host in response to an ANSI mode enquiry command. The string may be up to 30 characters long. Answerback concealed Factory default: Unchecked Checking this option will cause the Answerback string specified in the text box above to be locked from change and displayed as asterisks. Note that unchecking this option will cause the Answerback string to be deleted. Answerback mode Factory default: Unchecked This option applies to all emulations and specifies whether or not an answerback message is automatically sent to the host in response to an ASCII ENQ character. Send ACK Factory default: Checked This option applies to all emulations and specifies whether or not an ASCII ACK character is sent to the host port after certain commands have been executed. Setup Options 265

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340

Wyse Emulations
Setup Options
265
column. The default bell column number is 72 in 80 column mode
and 124 in 132 column mode.
Enhance
Factory default: Checked
When this option is checked, TeemTalk will recognize an additional
set of Wyse codes which are not normally supported by specific
non-Wyse terminals.
Answerback
Factory default: Unspecified
This enables you to specify the Answerback string that is sent to the
host in response to an ANSI mode enquiry command. The string
may be up to 30 characters long.
Answerback concealed
Factory default: Unchecked
Checking this option will cause the Answerback string specified in
the text box above to be locked from change and displayed as aster-
isks. Note that unchecking this option will cause the Answerback
string to be deleted.
Answerback mode
Factory default: Unchecked
This option applies to all emulations and specifies whether or not an
answerback message is automatically sent to the host in response to
an ASCII
ENQ
character.
Send ACK
Factory default: Checked
This option applies to all emulations and specifies whether or not an
ASCII
ACK
character is sent to the host port after certain com-
mands have been executed.