HP NetServer LP 1000r HP Netserver LP 1000r (1.13, 1.26 & 1.40 GHz) Techni - Page 1

HP NetServer LP 1000r Manual

Page 1 highlights

HP NetS erver LP 1000r Tec hnic al R eferenc e L abel A NetS erver R ear P anel (S ee C ) P ower S upply * NetS erver S erial Number is loc ated on ins ide of c has s is (vis ible when S lot 2 drive is removed). C P U_F AN 2 C HA_F AN 2 P C I R is er B oard S ys tem B oard C P U_F AN 1 C HA_F AN 1 CD-R OM Drive Flexible Dis k Drive S lot 2 * S lot 0 S lot 1 B Front Panel LE D Indic ators C D-R OM Drive R eset Temperature S C S I Ac tivity F a ns P ower P ower S witc h Label Manufacturer to print part number in C ode 39 barcode here P4632-80200 Flexible Dis k Drive C R ear Panel P ower Mous e P arallel P C I S lot (1) S lot 0 S lot 1 S lot 2 S lot 1 S lot 0 S lot 2 C ontrol P anel LE D Definitions P ower S teady green when operating normally. F las hing green at 1 Hz rate in s leep mode. S C S I Ac tivity S lot T e m pe ra ture Fan F las hes green when there is S C S I activity. Off when there is no activity. S teady green when drive is pres ent. Off when drive is not pres ent. S teady red for faulty drive or rebuild failure. Alternating green and red at 1 Hz rate for S C S I rebuild. Alternating green and red at 3 Hz rate indentifies drive. S teady green for normal operation. S teady red indicates temperature in exces s of thres hold. Alternating green and red indicates warning. S teady green for normal operation. S teady red indicates fan failure. Alternating green and red indicates warning. US B (2) Video K eyboard S erial / Management LAN B LAN A / Management E xternal S C S I C onnec tor R ear L E D Indic ator (L AN C onnec tor) Ac tivity Link Indic ator S teady G reen-Link Valid LED B linking G reen- Activity on LAN L AN S peed Indic ator LED OFF-10Mbps S teady Y ellow-100Mbps D S ys tem B oard B attery LAN B S erial B LAN A/Mgmt Video P arallel S erial A/ Mgmt. US B (2) Mous e (upper) K eyboard (lower) PCI R is er C ard C P U_F AN 1 IDE -2 I nte gra te d R emote As s is tant B oard FDD B oot Order 1. IDE C D-R OM 2. Flexible Dis k Drive 3. Hard Drive 4. B ootable C ards 5. Network C onnec tion SCSI B SCSI A P rocessor 1 C AUTION! Us e a new thermal pad when reins talling a heats ink P rocessor 2 C P U_F AN2 P ower C onnec tor 0 1 2 DIMMs 3 IDE -1 C onfiguration S witc h OPEN Not Us ed (Default = Off) B IOS R ecovery C lear P as s word C lear C MOS Not Us ed (Default = Off) Not Us ed (Default = Off) Not Us ed (Default = Off) Not Us ed (Default = Off) Open = Off C los ed = On E S ys tem C abling SCSI 1 SCSI 2 SCSI 3 C D-R OM Drive FDD 3 SCSI A SCSI B 4 E xternal SCSI S ys tem B oard 2 IDE-1 1 FDD C ables 1 2 3 4 T ype Flexible Dis k C able IDE C D-R OM C able S C S I C able Int / E xt S C S I C able F Mas s S torage Devic e Loc ations and S ettings Devic e S tandard F lexible Dis k Drive S tandard IDE C D-R OM Drive HP Accessory 9 GB HDD or HP Accessory 18 GB HDD or HP Accessory 36 GB HDD S tandard Dual S C S I C ontroller Devic e S ettings F ac tory ins talled F ac tory Ins talled Drives may be ins talled in S lot 0 through S lot 2 S C S I ID 7 Loc ation S ee P anel B Front P anel S ee P anel B Front P anel S ee P anel B Front P anel E mbedded S ee doc umentation with eac h devic e for further c onfiguration information. G Memory • Us e only P C 133 HP DIMMs . • The L P 1000r c an s upport up to 4GB . • DIMM s izes s upported are 128MB , 256MB , 512MB , and 1GB . • DIMMs may be ins talled in any c ombination in any DIMM s ocket. • 4MB of s tandard video memory is provided with the embedded video c ontroller. • When handling DIMMs obs erve anti-s tatic prec autions . H S ervic e Information E lec tronic S upport S ervic es • Internet Web P age http://www.hp.com/go/nets erver • Internet FTP ftp://ftp.nets erver.hp.com • C ompus erve Library GO HPPC • HP Navigator C D S upport Ques tions • HP -Authorized R es eller • C ompus erve Dis c us s ion Forum GO HPPC • US / C anada Phone S upport • E urope Phone S upport 1-970-635-1000 (+31-20) 581-3330 (Netherlands ) HP has offic es in over 100 c ountries . C heck your loc al telephone direc tory. S elec ted HP Ac c es s ories F or other tes ted ac c es s ories , download the Order As s is tant from the HP Web page. Audienc e As s umptions This Technical R eference C ard is for trained s ervice pers onnel. Hewlett-P ackard C ompany as s umes you are qualified in the s ervicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels . E lec tros tatic Dis c harge (E S D) Warning To avoid catas trophic or hidden damage to components , wear a wris t s trap and us e a s tatic-dis s ipative work s urface connected to the chas s is when handling components . Us e an antis tatic s ervice kit, s uch as 3M ® 8501/ 8502/8505 or equivalent. This information is s ubject to change without notice and is provided without warranty. © C opyright 2000 Hewlett-P ackard C ompany

  • 1

Label Manufacturer to print part
number in Code 39 barcode here
HP NetServer LP 1000r Technical Reference Label
P4632-80200
Electronic Support Services
Support Questions
Selected HP Accessories
Internet FTP
Compuserve Library
HP Navigator CD
GO HPPC
HP-Authorized Reseller
Compuserve Discussion Forum
US / Canada Phone Support
Europe Phone Support
GO HPPC
1-970-635-1000
(+31-20) 581-3330
(Netherlands)
Rear LED Indicator (LAN Connector)
Activity Link Indicator
Steady Green-Link Valid
B linking Green- Activity
on LAN
LAN Speed Indicator
OFF-10Mbps
S teady Yellow-100Mbps
LED
LED
E
System Cabling
D
System Board
A
NetServer
B
Front Panel
C
Rear Panel
SCSI 1
IDE-1
FDD
SCSI 2
SCSI 3
CD-ROM
Drive
FDD
System Board
3
4
2
1
SCSI A
SCSI B
External
SCSI
Cables
Type
Flexible Disk
Cable
IDE CD-ROM
Cable
SCSI Cable
Int / Ext SCSI
Cable
1
2
3
4
This information is subject to change without
notice and is provided without warranty.
© Copyright 2000 Hewlett-Packard Company
This Technical Reference Card is for trained
service personnel. Hewlett-Packard Company
assumes you are qualified in the servicing of
computer equipment and trained in recognizing
hazards in products with hazardous energy
levels.
Audience Assumptions
Electrostatic Discharge (ESD) Warning
To avoid catastrophic or hidden damage to
components, wear a wrist strap and use a
static-dissipative work surface connected to
the chassis when handling components. Use
an antistatic service kit, such as 3M
8501/
8502/8505 or equivalent.
®
For other tested accessories, download the
Order Assistant from the HP Web page.
HP has offices in over 100 countries.
Check your local telephone directory.
Use only PC 133 HP DIMMs.
The LP 1000r can support up to 4GB.
DIMM sizes supported are 128MB, 256MB, 512MB,
and 1GB.
DIMMs may be installed in any combination in
any DIMM socket.
4MB of standard video memory is provided with the
embedded video controller.
When handling DIMMs observe anti-static
precautions.
G
Memory
H
Service Information
See documentation with each device for further configuration information.
See Panel B
Front Panel
See Panel B
Front Panel
See Panel B
Front Panel
Embedded
Factory installed
Factory Installed
Drives may be installed
in S lot 0 through S lot 2
SCSI ID 7
Standard Flexible Disk Drive
Device
Device Settings
Location
Standard IDE CD-ROM Drive
HP Accessory 9 GB HDD or
HP Accessory 18 GB HDD or
HP Accessory 36 GB HDD
Standard Dual SCSI Controller
F
Mass Storage Device Locations
and Settings
PCI Riser
Board
System
Board
CD-ROM
Drive
CPU_FAN1
CHA_FAN1
CHA_FAN2
S lot 0
S lot 1
Slot 2
Flexible Disk
Drive
Power
S upply
Rear Panel
(See )
LED Indicators
Steady green when operating normally. Flashing green at 1 Hz rate in sleep mode.
Steady green for normal operation. Steady red indicates fan failure.
Alternating green and red indicates warning.
Steady green for normal operation. Steady red indicates temperature in
excess of threshold. Alternating green and red indicates warning.
Flashes green when there is SCSI activity. Off when there is no activity.
Steady green when drive is present. Off when drive is not present.
Steady red for faulty drive or rebuild failure. Alternating green and red at 1 Hz rate
for SCSI rebuild. Alternating green and red at 3 Hz rate indentifies drive.
Power
Control Panel LED Definitions
SCSI Activity
Slot
Temperature
Fan
Temperature
CD-ROM Drive
Flexible Disk Drive
S lot 0
S lot 1
S lot 2
SCSI Activity
Power Switch
Reset
Fans
Power
S lot 0
S lot 1
S lot 2
C
NetServer Serial Number
is located on inside of
chassis (visible when
Slot 2 drive is removed).
Power
Mouse
Keyboard
Parallel
USB (2)
PCI Slot (1)
Video
S erial /
Management
LAN A /
Management
External SCSI
Connector
LAN B
*
*
1. IDE CD-ROM
2. Flexible Disk Drive
3. Hard Drive
4. Bootable Cards
5. Network Connection
Boot Order
Clear CMOS
Clear Password
OPEN
Open = Off Closed = On
Not Used (Default = Off)
BIOS Recovery
Not Used (Default = Off)
Not Used (Default = Off)
Not Used (Default = Off)
Not Used (Default = Off)
CAUTION!
Use a new thermal
pad when reinstalling
a heatsink
IDE-2
CPU_FAN1
Video
USB (2)
B attery
LAN B
LAN A/Mgmt
S erial A/ Mgmt.
Serial B
DIMMs
0
1
2
3
Power
Connector
Processor 1
Processor 2
Mouse (upper)
Keyboard (lower)
Configuration
Switch
FDD
SCSI B
SCSI A
PCI
Riser
Card
IDE-1
Integrated
R emote
Assistant
Board
Parallel
CPU_FAN2
CPU_FAN2