HP Pavilion xe700 HP Pavilion PCs - (English) Seagate Hard Drive U Series 10 M - Page 22

Electromagnetic susceptibility, Reliability, Agency certification, Safety certification,

Page 22 highlights

14 U10 Family Product Manual, Rev. A 1.10 Electromagnetic susceptibility The drive operates without errors when subjected to the following: Radiated noise ≤ 3 volt/meter, 30 Hz to 500 MHz Electrostatic discharge* ≤ 10 KVolts Magnetic field strength ≤ 5 Gauss * Electrostatic discharge susceptibility is measured with the drive mounted in a representative computer system (mounted to a ground plane with an earth ground). Discharges are applied to the bezel or other external surfaces on the ground plane. 1.11 Reliability Nonrecoverable read errors Mean time between failures Contact start-stop cycles Preventive maintenance 1 per 1013 bits read, max 500,000 power-on hours (nominal power, 25°C ambient temperature) 50,000 cycles (at nominal voltage and temperature, with 60 cycles per hour and a 50% duty cycle) None required 1.12 Agency certification 1.12.1 Safety certification The drives are recognized in accordance with UL 1950 and CSA C22.2 (950) and meet all applicable sections of IEC950 and EN 60950 as tested by TUV North America. 1.12.2 Electromagnetic compatibility Hard drives that display the CE marking comply with European Union requirements specified in Electromagnetic Compatibility Directives. Testing is performed to standards EN 50082-1 and EN 55022-B. Seagate uses an independent laboratory to confirm compliance with the EC directives specified in the previous paragraph. Drives are tested in representative end-user systems. Although CE-marked Seagate drives

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

14
U10 Family Product Manual, Rev. A
1.10
Electromagnetic susceptibility
The drive operates without errors when subjected to the following:
1.11
Reliability
1.12
Agency certification
1.12.1
Safety certification
The drives are recognized in accordance with UL 1950 and CSA C22.2
(950) and meet all applicable sections of IEC950 and EN 60950 as tested
by TUV North America.
1.12.2
Electromagnetic compatibility
Hard drives that display the CE marking comply with European Union
requirements specified in Electromagnetic Compatibility Directives.
Testing is performed to standards EN 50082-1 and EN 55022-B.
Seagate uses an independent laboratory to confirm compliance with the
EC directives specified in the previous paragraph. Drives are tested in
representative end-user systems. Although CE-marked Seagate drives
Radiated noise
3 volt/meter, 30 Hz to 500 MHz
Electrostatic discharge*
10 KVolts
Magnetic field strength
5 Gauss
* Electrostatic discharge susceptibility is measured with the drive
mounted in a representative computer system (mounted to a ground
plane with an earth ground). Discharges are applied to the bezel or
other external surfaces on the ground plane.
Nonrecoverable read errors
1 per 10
13
bits read, max
Mean time between failures
500,000 power-on hours
(nominal power, 25°C ambient tem-
perature)
Contact start-stop cycles
50,000 cycles
(at nominal voltage and temperature,
with 60 cycles per hour and a 50%
duty cycle)
Preventive maintenance