HP ProLiant 4000 SMART-2DH Array Controller Reference Guide - Page 136

Drive Arrays, Two drive arrays with six physical drives

Page 136 highlights

D-3 The same physical drives may also be arranged into separate arrays, as illustrated in Figure D-4. Both arrays may be handled by the same controller. Physical Drives Drive 1 Drive 2 Drive 3 Drive 4 Drive 5 Drive 6 Drive Array 1 Logical Drive 1 Drive Array 2 Daz-9-17.EPS Figure D-4. Two drive arrays with six physical drives Logical Drive 2 Drive Arrays Drive arrays on the SMART-2DH Controller have several important attributes: s A single array cannot span more than one SMART-2DH Controller. s A single SMART-2DH Controller can control multiple arrays. s Arrays must have at least one and may have up to 14 physical drives. s Arrays consist of at least one and may have up to 32 logical drives (maximum 32 logical drives per controller). s For maximum space efficiency, all drives in a single array should be the same capacity. SMART-2DH Array Controller Reference Guide Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: K-APPD.DOC Last Saved On: 2/27/98 12:06 PM COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

D-3
SMART-2DH Array Controller Reference Guide
Writer: Pamela King
Project: SMART-2DH Array Controller Reference Guide
Comments: 295469-002
File Name: K-APPD.DOC
Last Saved On: 2/27/98 12:06 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
The same physical drives may also be arranged into separate arrays, as
illustrated in Figure D-4. Both arrays may be handled by the same controller.
Daz-9-17.EPS
Physical Drives
Logical
Drive 1
Logical
Drive 2
Drive Array 1
Drive 1
Drive 2
Drive 3
Drive 4
Drive 5
Drive 6
Drive Array 2
Figure D-4.
Two drive arrays with six physical drives
Drive Arrays
Drive arrays on the SMART-2DH Controller have several important
attributes:
A single array cannot span more than one SMART-2DH Controller.
A single SMART-2DH Controller can control multiple arrays.
Arrays must have at least one and may have up to 14 physical drives.
Arrays consist of at least one and may have up to 32 logical drives
(maximum 32 logical drives per controller).
For maximum space efficiency, all drives in a single array should be
the same capacity.