HP ProLiant 4500 PCI Bus Numbering in a Microsoft Windows NT Environment - Page 35

Configuring Other Manufacturer’s Network Controllers with the Network Applet, Remove, Continue

Page 35 highlights

PCI Bus Numbering in a Microsoft Windows NT Environment 35 After the computer restarts, Figure 11 shows that the computer, the slot, and the bus number information agree with the Configuration C results: • Slot 1 contains a NC3131 Fast Ethernet NIC on Bus 3. • Slot 2 contains a NC3131 Fast Ethernet NIC on Bus 4. • Slot 3 contains a NC3131 Fast Ethernet NIC on Bus 5. Figure 11. NICs in configuration c-test 2 after being reconfigured Configuring Other Manufacturer's Network Controllers with the Network Applet If your server includes other manufacturer's network controllers, perform the following steps to reset the controller: 1. Double-click the Network icon, in the Windows NT Control Panel, and record pertinent information for all controllers in the server. 2. Highlight the controller that did not load and select the Remove option. Note: The Remove and Add steps are a manual process and must be performed separately. 3. Re-add the controller by selecting the controller from the Adapter List and then select Continue. 4. Enter the controller information recorded (IP address, etc.) in the Network Settings dialog box. 5. Shut down and restart the server when the network controller configuration completes. When configuration changes are made affecting other manufacturer's controllers, the Compaq Network Teaming and configuration Utility to reestablish bindings (required when the controller receives a new bus number because of modifications). 13UK-1200A-WWEN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

PCI Bus Numbering in a Microsoft Windows NT Environment
35
13UK-1200A-WWEN
After the computer restarts, Figure 11 shows that the computer, the slot, and the bus number
information agree with the Configuration C results:
Slot 1 contains a NC3131 Fast Ethernet NIC on Bus 3.
Slot 2 contains a NC3131 Fast Ethernet NIC on Bus 4.
Slot 3 contains a NC3131 Fast Ethernet NIC on Bus 5.
Figure 11. NICs in configuration c–test 2 after being reconfigured
Configuring Other Manufacturer’s Network Controllers with the Network Applet
If your server includes other manufacturer’s network controllers, perform the following steps to
reset the controller:
1.
Double-click the Network icon, in the Windows NT Control Panel, and record pertinent
information for all controllers in the server.
2.
Highlight the controller that did not load and select the
Remove
option.
Note:
The Remove and Add steps are a manual process and must be performed separately.
3.
Re-add the controller by selecting the controller from the Adapter List and then select
Continue
.
4.
Enter the controller information recorded (IP address, etc.) in the Network Settings dialog
box.
5.
Shut down and restart the server when the network controller configuration completes.
When configuration changes are made affecting other manufacturer’s controllers, the Compaq
Network Teaming and configuration Utility to reestablish bindings (required when the controller