HP ProLiant DL140 Intel Processor Installation Instructions ProLiant DL140 Gen

HP ProLiant DL140 - G2 Server Manual

HP ProLiant DL140 manual content summary:

  • 1
  • 2
  • 3

Intel Processor
Installation Instructions
for HP ProLiant DL140
Generation 2 Server
Read instructions completely before beginning
installation procedure.
© Copyright 2005 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only
warranties for HP products and services are set forth in the express warranty
statements accompanying such products and services. Nothing herein should be
construed as constituting an additional warranty. HP shall not be liable for technical
or editorial errors or omissions contained herein.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its
subsidiaries in the United States and other countries.
Intel Processor Installation Instructions
First Edition (March 2005)
Part Number 381735-001
Locating the CPU Socket
The server’s dual mPGA604 (604-pin) sockets support Intel Xeon
800 MHz FSB processors. The location of the two CPU sockets
(U6 and U18) is shown in the figure below.
Installation Guidelines
When installing a processor, observe the following important
guidelines:
Processor socket 0 (U6) must always be populated. If no
processor is installed in this socket, the system will fail to boot
and halt during POST. This error prevents the system from
functioning properly.
Handle the processor and heat sink with care. Damage to either
may affect processor performance.
The pins beneath the processor are very fragile. Do not bend or
damage them.
Always use a new heat sink when replacing processors. Failure
to use new components can cause damage to the processor.
Be sure that the server has the most recent ROM version.
Failure to flash the ROM before installing processors can cause
system failure.