5. Install the DIMM. 6. Install the access panel (on page 20). Hot-plug SAS and SATA hard drive options When adding hard drives to the server, observe the following general guidelines: • The system automatically sets all device numbers. • If only one hard drive is used, install it in the bay with the lowest device number ("SAS and SATA device numbers" on page 14). • Hard drives must be SFF types. • Drives should be the same capacity to provide the greatest storage space efficiency when drives are grouped together into the same drive array. Removing hard drive blanks CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. Hardware options installation 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

Hardware options installation 39
5.
Install the DIMM.
6.
Install the access panel (on page
20
).
Hot-plug SAS and SATA hard drive options
When adding hard drives to the server, observe the following general guidelines:
The system automatically sets all device numbers.
If only one hard drive is used, install it in the bay with the lowest device number ("
SAS and SATA
device numbers
" on page
14
).
Hard drives must be SFF types.
Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
Removing hard drive blanks
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.