Invalid SSP adapter ID., Invalid RAID Array ID.
View all HP ProLiant ML310e manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Error code Error message Comment or clarification 2851 Invalid RAID Array ID. The scripted RAID Array ID is invalid. Use characters from the set a-z, A-Z, 0-9 and [space]. The ID cannot end with a space character or exceed the maximum number of characters allowed by the controller. 2852 Invalid SSP state. - 2853 Cannot change SSP settings. - 2854 Invalid SSP adapter ID. - 2855 Controller does not support logical drive - SSP states. Use the SSPState controller command to set the controller SSP state. 2856 Controller does not support controller SSP - state. Use the LogicalDriveSSPState logical drive command to set SSP states for each logical drive. 2857 Invalid surface scan delay. - 2861 Controller does not support redundancy The controller is not redundant or does not support settings. redundancy settings. 2864 Invalid preferred path mode. The specified value for the preferred path mode is not valid, or the controller is not available. 2865 Invalid preferred path. The specified preferred path is not a valid chassis slot for an available active controller, or the controller is not available. 2866 Failure opening capture file . - 2867 Failure opening input file . - 2868 Failure opening error file . - 2869 command expected. The command is missing or in the wrong place in the script file. 2870 is not a supported command. - 2871 is not a Controller command. The command does not belong in the Controller section of the script file. 2872 is not an Array command. The command does not belong in the Array section of the script file. 2873 is not a Logical Drive command. The command does not belong in the Logical Drive section of the script file. 2874 is not an HBA command. The command does not belong in the HBA section of the script file. 2875 More than one command cannot - exist in the same section. 2876 Invalid physical drive count. The script specifies more drives than are available of the specified drive type. 2877 No spares available. No drives were found that could be used as spares for the specified array. 2878 Spare request for RAID 0 is invalid. RAID 0 does not support spares. 2879 Reset and reconfigure combined error. A controller reset with data loss was specified while in Reconfigure mode. 2880 Invalid drive type specified. - 50 Scripting Toolkit utilities