technologies Technology brief Introduction...2 Mechanical design for extreme scale-out computing 2 HP ProLiant s6500 chassis ...2 Rack management with HP ProLiant SL Advanced Power Manager 3 SL6500 server trays ...3 Memory technologies ...7 Unbuffered and registered DIMMs ...7 Fan speed control - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 2
power supplies and fans to maintain total flexibility. The HP ProLiant SL6500 Scalable System consists of: • A full-width, rack-mountable ProLiant s6500 4U chassis • Up to eight half-width 1U or four half-width 2U server trays, containing a mother board with industry-standard processors, Double Data - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 3
to ensure adequate cooling of the other trays. The chassis has no midplane. The I/O connectors for each server are at the front of the chassis for easy servicing and unrestricted airflow. Rack management with HP ProLiant SL Advanced Power Manager The HP ProLiant SL Advanced Power Manager (APM) is - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 4
system board and fit in the 4U HP ProLiant s6500 chassis. SL390s G7servers have two processor sockets, twelve DDR3 sockets, two 1 Gb Ethernet ports, one 10 Gb Ethernet port, and an onboard port for optional InfiniBand support. The SL390s G7 1U half-width server tray is ideal for HPC environments. It - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 5
G7 1U half-width server tray The SL390s G7 2U half-width server tray works well in balanced GPU and compute intensive HPC computing. It supports a single, low profile PCIe 2.0 x8 slot and three internal PCIe 2.0 x16 slots dedicated for GPUs, consuming up to 225 watts each (Figure 4). The QuickSpecs - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 6
Figure 4. SL390s G7 2U half-width server tray HP ProLiant SL170s G6 server The HP ProLiant SL170s G6 server tray (Figure 5), with its 1U half-width footprint, provides compute power and density. Up to eight independent SL170z G6 server trays fit into the s6500 chassis. Each server tray supports up - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 7
Figure 5. HP ProLiant SL170s G6 server tray Memory technologies The SL6500 system uses DDR3 memory with options for memory mirroring and memory channel interleaving. You use the G6 or G7 server ROM-based setup utility (RBSU) to control these options. Unbuffered and registered DIMMs DDR3 DIMMs can be - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 8
at this speed. Currently, only certain ProLiant SL G6 and G7 server trays using the Xeon 5500 or 5600 Series processors operating at 95W support operating the memory at 1333 MT/s. Fan speed control During POST, the HP BIOS in ProLiant G6 and G7 servers verifies the presence of an integrated thermal - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 9
disk drives in a server. HP Tesla Computing Modules For use in HP ProLiant SL390s servers, we support computational accelerator modules based on Nvidia® Tesla™ GPU technology. The following Tesla Computing Modules are available from HP: • HP Tesla M2050 2-Slot Passive Module • HP Tesla M2070 2-Slot - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 10
Agents supported by other ProLiant servers. Therefore, you can use HP Systems Insight Manager (SIM) 5.3 and later to manage SL6500 server trays. Insight Management Agents provide alerts that let you significantly reduce unplanned downtime. You can also use any other SNMP-based management tool. The - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 11
GUID), asset tag, and chassis ID • Accurate system event logging using IPMI • Reliable in-band keyboard controller style (KCS) interface and out-of-band LAN interface HP Lights Out 100i ProLiant SL170s G6 server trays include LO100i, which provides core embedded management functions. LO100i supports - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 12
HP Integrated Lights-Out 3 ProLiant SL390s G7 server trays include iLO 3 management. You can upgrade your iLO 3 firmware with an iLO Advanced license. For environments with elevated security requirements, iLO 3 includes an Advanced Encryption Standard (AES) encryption engine. AES is an encryption - HP ProLiant SL390s | HP ProLiant SL6500 Scalable System technologies - Page 13
Tool HP Power Advisor HP ProLiant SL390s Generation 7 Web address http://bizsupport2.austin.hp.com/bc/docs/support/Suppo rtManual/c01828162/c01828162.pdf http://h20000.www2.hp.com/bc/docs/support/Support Manual/c00191707/c00191707.pdf http://h20000.www2.hp.com/bc/docs/support/Support Manual
HP ProLiant SL6500 Scalable System
technologies
Technology brief
Introduction
.........................................................................................................................................
2
Mechanical design for extreme scale-out computing
.................................................................................
2
HP ProLiant s6500 chassis
................................................................................................................
2
Rack management with HP ProLiant SL Advanced Power Manager
........................................................
3
SL6500 server trays
.........................................................................................................................
3
Memory technologies
...........................................................................................................................
7
Unbuffered and registered DIMMs
.....................................................................................................
7
Fan speed control
............................................................................................................................
8
I/O technologies
.................................................................................................................................
8
Hard drive technologies
....................................................................................................................
8
Networking technologies
..................................................................................................................
8
HP Tesla Computing Modules
............................................................................................................
9
Power and thermal technologies
............................................................................................................
9
Power supply options
........................................................................................................................
9
Management and deployment
...............................................................................................................
9
Power and thermal management with the Power Management Controller
.............................................
10
Remote management and control
.....................................................................................................
11
Server deployment
.........................................................................................................................
12
For more information
..........................................................................................................................
13
Call to action
....................................................................................................................................
13