HP Scitex FB10000 Geffen TS Error 66065 - Page 1

HP Scitex FB10000 Manual

Page 1 highlights

Error ID: 60065 - IDS - Unable to fill the Light Cyan secondary tank (timed out) FB10000 Error Message Troubleshooting FB10000 Error Message Troubleshooting Error ID: 60065 - IDS - Unable to fill the Light Cyan secondary tank (timed out) Error Message: 66065 IDS - Unable to fill the Light Cyan secondary tank (timed out) Check the secondary tank pump in the ink cabinet. If the error persists go to Troubleshooting guide Note: Before starting to troubleshoot this error, please consult the machine log for other messages that appear in the log and look for hints that may lead you to the source of the current error, for instance, which components are mentioned in the string. Possible Causes • Light Cyan ink tubing to secondary ink tank is obstructed • B&R did not send the command to the Light Cyan secondary tank feeding pump • Light Cyan 5 micron ink filter is clogged • Light Cyan secondary tank feeding pump is faulty • Light Cyan 3 Way-switching valve is faulty 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

Error ID: 60065 – IDS – Unable to fill the Light Cyan secondary tank (timed out)
FB10000 Error Message Troubleshooting
FB10000 Error Message Troubleshooting
Error ID: 60065 – IDS – Unable to fill the Light Cyan secondary tank (timed out)
Error Message:
66065
<Month, Day, Time>
IDS - Unable to fill the Light Cyan secondary tank (timed out)
Check the secondary tank pump in the ink cabinet.
If the error persists go to
Troubleshooting guide
Note: Before starting to troubleshoot this error, please consult the machine log for other messages that appear in the log and look for hints that
may lead you to the source of the current error, for instance, which components are mentioned in the string.
Possible Causes
Light Cyan ink tubing to secondary ink tank is obstructed
B&R did not send the command to the Light Cyan secondary tank feeding pump
Light Cyan 5 micron ink filter is clogged
Light Cyan
secondary tank feeding pump is faulty
Light Cyan 3 Way-switching valve is faulty
1