  • HP Scitex FB10000 | Geffen TS Error 66310 - Page 1
    Opened FB10000 Error Message Troubleshooting Error ID: 66310 - UV - UV High Voltage Guard is Opened 66310 UV High Voltage Guard is opened For more details open the Troubleshooting guide Possible Causes • High Voltage Guards protecting the UV lamp are open • Wiring problem between
  • HP Scitex FB10000 | Geffen TS Error 66310 - Page 2
    Guard is Opened Recommended actions High Voltage Guards protecting the UV lamp are open 1. Check that the guards protecting the UV lamp are properly closed. FB10000 Error Message Troubleshooting Top 2. Check the safety PLC status. 3. If there are red lights, software
  • HP Scitex FB10000 | Geffen TS Error 66310 - Page 3
    66310 - UV - UV High Voltage Guard is Opened Wiring problem between safety PLC and XP1 socket 1. Shut down the UV .1 X6 and XP1.A2 X6.1 and XP1.A4 3. If the problem persists, contact your HP support specialist. Note: See also Baldwin document for Alarm 6. FB10000 Error Message Troubleshooting 3
  • 1
  • 2
  • 3

Error ID: 66310 - UV – UV High Voltage Guard is Opened
FB10000 Error Message Troubleshooting
FB10000 Error Message Troubleshooting
Error ID: 66310 - UV – UV High Voltage Guard is Opened
66310 <Month, Day, Time>
UV High Voltage Guard is opened
For more details open the
Troubleshooting guide
Possible Causes
High Voltage Guards protecting the UV lamp are open
Wiring problem between safety PLC and XP1 socket
1