HP Scitex FB10000 Geffen TS Error 66310 - Page 3

Wiring problem between safety PLC and XP1 socket

Page 3 highlights

Error ID: 66310 - UV - UV High Voltage Guard is Opened Wiring problem between safety PLC and XP1 socket 1. Shut down the UV cabinet before any check. 2. Check the wiring path between the PLC and the socket XP1. Safety PLC input 3 and XP1.A1 Safety PLC input 4 and XP1.A3 Safety PLC Pulse output 3 (Terminal 23) and X6 Safety PLC Pulse output 4 (Terminal 24 and X6.1 X6 and XP1.A2 X6.1 and XP1.A4 3. If the problem persists, contact your HP support specialist. Note: See also Baldwin document for Alarm 6. FB10000 Error Message Troubleshooting 3

  • 1
  • 2
  • 3

Error ID: 66310 - UV – UV High Voltage Guard is Opened
FB10000 Error Message Troubleshooting
Wiring problem between safety PLC and XP1 socket
1.
Shut down the UV cabinet before any check.
2.
Check the wiring path between the PLC and the socket XP1.
Safety PLC input 3 and XP1.A1
Safety PLC input 4 and XP1.A3
Safety PLC Pulse output 3 (Terminal 23) and X6
Safety PLC Pulse output 4 (Terminal 24 and X6.1
X6 and XP1.A2
X6.1 and XP1.A4
3.
If the problem persists, contact your HP support specialist.
Note:
See also Baldwin document for Alarm 6.
3