installation guide hp StorageWorks SAN switch 2/8 version 3.1.x Product Version: 3.1.x Third Edition (June 2003) Part Number: AA-RSB6C-TE This installation guide provides basic procedures for setting up, configuring, and managing the SAN Switch 2/8 EL and SAN Switch 2/8 power pak models. - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 2
the Brocade B weave logo, Brocade: the Intelligent Platform for Networking Storage, SilkWorm, and SilkWorm Express, are trademarks or registered trademarks of Brocade additional warranty. Printed in the U.S.A. SAN Switch 2/8 Version 3.1.x Installation Guide Third Edition (June 2003) Part Number: AA- - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 3
15 HP Technical Support 15 HP Storage Website 15 HP Authorized Reseller 16 1 Overview 17 SAN Switch 2/8 Features 18 Firmware 18 Hardware 19 SFP Media Side 20 Optical Ports 20 ISL Trunking 20 SFPs 20 Fan Side 21 Optional Hardware Kits 22 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 4
HP System/e Rack 36 Items Required for the HP System/e Rack 36 Installing the Switch in the Optional HP System/e Rack 38 Installing the Switch Using the HP StorageWorks SAN Switch Multiple Switches into an Existing SAN 67 Cascading Switches 68 4 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 5
the SAN Switch 2/8 77 Changing the Admin Password and User ID 77 Configuring the IP and Fibre Channel Address 78 Displaying Devices within the Fabric 79 Checking the Firmware Version 79 Setting the Switch Date and Time 79 Displaying Switch Configuration Settings 80 SAN Switch 2/8 Diagnostic - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 6
on a SAN Switch 2/8 with plenum 53 21 Installing the switch into a rack (HP 9000 Series or comparable EIA rack 54 22 Installing the switch into a rack (HP System/e rack 55 23 Connecting the Serial cable 58 24 Connecting the Ethernet cable 60 6 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 7
25 Inserting a cable into an SFP 66 Tables 1 Document Conventions 11 2 SAN Switch 2/8 Orderable Hardware 22 3 Shipping Carton Contents 29 4 Front Panel LED Patterns 96 8 Environmental Requirements 97 9 Cabling Pinouts if Pin 7 is Used 98 SAN Switch 2/8 Version 3.1.x Installation Guide 7 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 8
Contents 8 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 9
about this guide This installation guAidbe porouvitdetshinisforGmautioindtoehelp you set up and configure the HP StorageWorks SAN Switch 2/8. About this Guide About this Guide topics include: ■ Overview, page 10 ■ Conventions, page 11 ■ Rack Stability, page 14 ■ Getting Help, page 15 SAN Switch 2/8 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 10
section of the HP StorageWorks SAN Switch 2/8 Version 3.1.x Release Notes. For the latest information, documentation and firmware releases, please visit the following HP StorageWorks website: http://www.hp.com/country/us/eng/prodserv/storage.html For information about Fibre Channel standards, visit - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 11
hp.com Text Symbols The following symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or death. SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 12
symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal injury from electrical shock hazards component, allow the surface to cool before touching. 12 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 13
About this Guide Power supplies or systems marked with these symbols indicate the presence of multiple sources of or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. SAN Switch 2/8 Version 3.1.x Installation Guide 13 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 14
About this Guide Rack Stability Rack stability protects personal and equipment. WARNING: To reduce the risk of personal injury or damage to the at any time. A rack may become unstable if more than one rack component is extended for any reason. 14 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 15
■ Detailed, specific questions HP Storage Website The HP website has the latest information on this product. Access storage at: http://www.hp.com/country/us/eng/prodserv/storage.html From this website, select the appropriate product or solution. SAN Switch 2/8 Version 3.1.x Installation Guide 15 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 16
Guide HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518. ■ In Canada, call 1-800-263-5868. ■ Elsewhere, see the HP website for locations and telephone numbers: http://www.hp.com 16 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 17
HP StorageWorks SAN Switch 2/8 is a high-performance 8-port, 2 gigabit (Gb) Fibre Channel (FC) switch used to interconnect storage devices, hosts, and servers in a SAN. The HP StorageWorks SAN Switch 2/8 is offered in two configurations; the 2/8 EL and 2/8 power pak. Refer to the HP StorageWorks SAN - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 18
-specific information. Firmware The SAN Switch 2/8 operates using Fabric Operating System (FOS) firmware v3.1.x. The firmware supports: ■ An optional Security feature, providing security mechanisms at all vulnerable points in a SAN fabric, from hosts to storage at the port, switch, and fabric - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 19
the front panel - One Ethernet activity LED on the front panel - One port readiness LED on the back panel ■ Universal input power supply with AC switch ■ Five fans SAN Switch 2/8 Version 3.1.x Installation Guide 19 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 20
directly adjacent switches, while preserving in-order delivery. For information about ISL trunking, refer to the HP StorageWorks ISL Trunking Version 3.1.x/4.1.x User Guide. SFPs The ports connect to SFP media. SFPs are universal and self-configuring. 20 SAN Switch 2/8 Version 3.1.x Installation - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 21
Overview Fan Side Figure 2 shows the fan side of the SAN Switch 2/8. The rear panel houses the five fans, and port readiness LED. 1 2 1 Fan (5) 2 Port readiness LED Figure 2: Fan side SHR-2494B SAN Switch 2/8 Version 3.1.x Installation Guide 21 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 22
Overview Optional Hardware Kits HP provides the following optional hardware kits in support of the SAN Switch 2/8, see Table 2. Table 2: SAN Switch 2/8 Orderable Hardware Accessory Short wavelength SFP Long wavelength SFP, 10 km 2m LC-to-LC Fibre Channel (fc) cable 2m LC-to-LC multi-mode fc - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 23
Comparable EIA Rack, page 33 ■ Optional HP System/e Rack, page 36 ■ Installing the Switch Using the HP StorageWorks SAN Switch Universal Rack Mount Kit, page 46 ■ Power On Self-Test, page 56 ■ Configuring SAN Switch 2/8 Network Addressing, page 57 ■ Connecting the SAN Switch 2/8 to the LAN, page 60 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 24
2/8 EL to Full Fabric. To upgrade, you must install the optional Full Fabric license on each SAN Switch 2/8 EL. See the "Four Switch Limitation Workarounds" section on page page 27 for instructions on how to purchase the Full Fabric license. 24 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 25
every 75 seconds (not configurable). Figure 3 shows a typical Web Tools Warning Message. Figure 3: Four switch limitation Web Tools error message Note: The SAN Switch 2/8 EL displays a separate error condition warning message in the dialog box. SAN Switch 2/8 Version 3.1.x Installation Guide 25 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 26
Mode is enabled on a SAN Switch 2/8 EL with a IV_FABRIC license installed, the four switch limitation warning messages display. If the IV_FABRIC license is not installed, Quiet Mode works as described in the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide. 26 SAN Switch 2/8 Version - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 27
authorized HP Sales representative, or go to the HP website: http://www.hp.com ■ In fabrics which contain five or more switches and that have at least one switch with the IV_FABRIC license installed, reduce the number of switches to four or less. SAN Switch 2/8 Version 3.1.x Installation Guide 27 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 28
Rack Mount Kit shown in Figure 5 may not represent the kit that shipped with your switch. HP reserves the right to substitute Rack Mount Kits, providing applicable instructions with each switch. 3 4 5 1 2 6 Figure 5: Carton contents SHR-2495B 28 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 29
Description One HP StorageWorks SAN Switch 2/8 product accessory bag containing CD, license, documentation and Release Notes HP StorageWorks Switch 2/8 switch. For a complete list of possible HP rack mount kits, see Installation Guidelines on page 30. SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 30
HP StorageWorks SAN Switch Universal Rack Mount Kit. For instructions, see Installing the Switch Using the HP StorageWorks SAN Switch Universal Rack Mount Kit, page 46. Note: Depending on time of purchase, the SAN Switch the event of an earthquake. 30 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 31
chassis. HP recommends installing the switch so switch uses a universal power supply capable of functioning worldwide without voltage jumpers or switches. The power supply is auto ranging in terms of accommodating input voltages and line frequencies. SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 32
runs a Power On Self-Test (POST). Note: Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see the "Configuring SAN Switch 2/8 Network Addressing" section on page 57. 32 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 33
sections for complete installation instructions. Obtain the following tools: ■ Fixed Rack Mount Kit (supplied with the switch) ■ A #2 Phillips screwdriver with torque capability ■ Clamps or other means to temporarily support the switch ■ Torque screwdriver Caution: The SAN Switch 2/8 ships with the - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 34
the Fixed Rack Mount Kit rails to the switch 3. Position the switch in the rack as shown in Figure 6, providing temporary support under the switch (use clamps if necessary). 4. To secure rail. 6. Tighten all screws and torque to 25-inch pounds. 34 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 35
rear bracket (Item 2) to the left rear rack rail. 11. Tighten all screws to a torque of 25-inch pounds. 12. Connect the SAN Switch 2/8 power cord to the power connector on the switch. See Figure 7. Figure 7: Connecting the power cord SAN Switch 2/8 Version 3.1.x Installation Guide SHR-2496B 35 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 36
SAN Switch 2/8 Optional HP System/e Rack This section lists instructions for installing the SAN Switch 2/8 in the optional HP System/e Rack. Items Required for the HP System/e Rack The HP System/e Rack Kit consists of the following items: ■ HP clip 36 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 37
32 x 5/8 Phillips pan-head screw with attached lock washer (Use if installing in HP 9000 Series rack/ EIA rack) (6) Spacer (Use if installing in HP 9000 Series rack/ EIA rack) (4) M5 flat washer (Use if installing in HP 9000 Series rack/ EIA rack) SAN Switch 2/8 Version 3.1.x Installation Guide 37 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 38
/e Rack Before you begin, locate the following items to install the SAN Switch 2/8 in the HP System/e Rack Kit: ■ SAN Switch 2/8 ■ #2 Phillips and T25 Torx screwdrivers Caution: For proper airflow, the SFP media side of the SAN Switch 2/8 must face the rear of the rack. This mounting allows air - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 39
Installing the SAN Switch 2/8 2 1 1 Rear rail tray bracket 2 M5 Torx head screw with captive lock washer Figure 8: Installing the rear rail tray brackets SHR-2557 SAN Switch 2/8 Version 3.1.x Installation Guide 39 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 40
Installing the SAN Switch 2/8 3. Install two M5 U-type Tinnerman clips for each of the front columns of the rack in the top and bottom slotted portion of the outer rail flush against the rear rail-tray brackets. Install them as shown in Figure 10. 40 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 41
as required. [8] Adjust the size of the outer graphic frame as required. Delete this set of instructions 1 Rubber washer (1 of 2) 2 Rear rail tray bracket (1 of 2) Figure 10: Installing install the upper left and lower right screws until later. SAN Switch 2/8 Version 3.1.x Installation Guide 41 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 42
of any longer lengths can cause damage to internal components of the switch. Be sure to install the flat washers along with the pan-head screws. Before tightening screws, make sure that the rails are centered to the overall height of the switch. 42 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 43
4 3 2 1 Plenum 2 8-32 x 5/16 phillips pan head screws 3 Flat washers 4 Inner rails (1 of 2) Figure 12: Assembling the inner rails with plenum SHR-2561A Note: Please note that the numbered items shown in Figure 12 must be ordered separately. SAN Switch 2/8 Version 3.1.x Installation Guide 43 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 44
inner rails into the outer rails as shown in Figure 13. SHR-2562A Figure 13: Installing the switch into an HP Rack 7. Install the two remaining M5 Torx screws into the upper left and lower right holes to complete the installation. See Figure 14. 44 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 45
by default each time it is turned on. Note: Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see "Configuring SAN Switch 2/8 Network Addressing" later in this chapter. SAN Switch 2/8 Version 3.1.x Installation Guide 45 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 46
SAN Switch 2/8 Installing the Switch Using the HP StorageWorks SAN Switch Universal Rack Mount Kit This section provides instructions for installing the SAN Switch 2/8 in an HP rack using the HP StorageWorks SAN Switch with captive star lock washer 46 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 47
prevents switch overheating, which may cause it to fail. To install the switch in a rack: 1. Check contents of the shipping carton to verify all the required parts and hardware are available. 2. Choose a mounting location in the rack for the switch. SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 48
Phillips pan-head screws with captive star lock washers and (2) #10 adapter washers as shown in Figure 15. Figure 15: Installing the rear mounting brackets (HP 9000 Series or comparable EIA rack) 48 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 49
brackets with (2) #10-32 x 1/2-inch Phillips pan-head screws and (2) #10 alignment washers as shown in Figure 16. Figure 16: Installing the rear mounting brackets (HP System/e rack-left rear upright) SAN Switch 2/8 Version 3.1.x Installation Guide 49 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 50
Installing the SAN Switch 2/8 Note: This kit contains both left rails and right rails. The rails are marked with Right them. The nuts will be tightened later in step 7. Figure 17: Installing the outer rails (HP 9000 Series or comparable EIA rack) 50 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 51
and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 18. Figure 18: Assembling the outer rails (HP 9000 Series or comparable EIA rack) SAN Switch 2/8 Version 3.1.x Installation Guide 51 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 52
Installing the SAN Switch 2/8 - For an HP System/e rack, install two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock lower hole locations of the left rail. See Figure 19. Figure 19: Assembling the outer rails (HP System/e rack) 52 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 53
overheating. If the plenum shipped as a separate item, refer to Installing the Switch in the Optional HP System/e Rack, step 5, for complete plenum installation instructions. Figure 20: Assembling the inner rails on a SAN Switch 2/8 with plenum SAN Switch 2/8 Version 3.1.x Installation Guide 53 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 54
Installing the switch into a rack (HP 9000 Series or comparable EIA rack) Insert the switch into the rack and install (2) #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers with one on each side. See Figure 21 and Figure 22. 54 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 55
a rack (HP System/e rack) 7. Tighten the nuts installed in step a of step 4 on page 50. Note: To uninstall a switch, remove the middle #10-32 x 1/2-inch Phillips pan head screw with captive star lock washer from either side of the rack uprights. SAN Switch 2/8 Version 3.1.x Installation Guide 55 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 56
run during POST via LED activity, the error log, or the CLI using the errShow command. For more information about error messages, refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide. 56 SAN Switch 2/8 Version 3.1.x Installation - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 57
Addresses via a Serial Connection Use the following steps to verify or change the SAN Switch 2/8 IP address, subnetmask, or gateway address. Note: During first time setup . 1. Remove the shipping plug from the SAN Switch 2/8 Serial port. SAN Switch 2/8 Version 3.1.x Installation Guide 57 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 58
shows instructions specific to HyperTerminal. If using a different application, consult the specific application's documentation. 6. Using HyperTerminal, configure the port settings as follows: ■ Bits per second: 9600 ■ Databits: 8 ■ Parity: None ■ Stop bits: 1 ■ Flow control: None 58 SAN Switch - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 59
Installing the SAN Switch 2/8 To configure port settings in a UNIX® environment, type: tip /dev/ttyb -9600 7. Log onto the switch (with administrative privileges). The default administrative logon is admin and the default password is password. a. Enter the following at the prompt: ipAddrSet b. Enter - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 60
. Verify that the switch is not accessed from any other connections during the remaining steps. 4. Log on to the switch with administrative privileges by telnet. The default administrative logon is admin and the default password is password. 60 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 61
formats are assigned by a Fibre Channel switch when a device logs into the fabric. An example PID might look like this: 011F00 For a SAN to work correctly, all HP switches must have the same Core determined by the number displayed in the brackets. SAN Switch 2/8 Version 3.1.x Installation Guide 61 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 62
60 for instructions on connecting Fibre Channel cables. 11. If necessary, type cfgEnable to re-establish zoning. Note: Once the switch Core PID format is set, it is stored in the flash memory of the switch and it is NOT necessary to set it again during subsequent firmware upgrades. 62 SAN Switch - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 63
the SAN Switch 2/8 Modifying Domain IDs Optional. Modify the domain IDs if desired, as follows. Note: It is best to assign a unique domain ID prior to connecting the switch to other switches in the SAN. This eliminates the possibility of domain ID overlap.The default domain ID is 1. If the default - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 64
Installing the SAN Switch 2/8 Specifying Custom Status Policies Optional. If desired, specify any custom status policies for the fabric as To completely deactivate the alarm for a particular condition, enter 0 at the prompt for that condition. 64 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 65
to connect the SFPs and cables to SAN Switch 2/8 ports as required. Note: The ports and cables used in trunking groups must meet specific requirements. For a list of these requirements, refer to the HP StorageWorks ISL Trunking Version 3.1.x/4.1.x User Guide. 1. Remove the shipping plugs from the - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 66
is running properly. 1. Access your browser. 2. At the URL address window type, http://your switch IP address. 3. Press Enter. 4. If connected properly, the name of your switch appears (in green) in the Web browser window, indicating Healthy/OK. 66 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 67
the SAN. The default domain setting is 1. Note: If a switch boot failure occurs, the switch must be taken offline for repair or replacement. Contact your HP Technical Support for assistance. 5. Power off the new switch and connect one Fibre Channel cable from the SAN to the new switch. SAN Switch - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 68
may change when disabling and enabling one of the switches, or rebooting one of the switches if the domain is not set using the configure command. Switch parameters for all switches in a SAN must be the same, or the switch may not join the SAN. 68 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 69
Managing the SAN Switch 2/8 3 This chapter covers the following topics: ■ Interpreting LED Activity, page 70 ■ Management Overview, page 75 ■ Running Basic Switch Operations Using Telnet, page 77 ■ SAN Switch 2/8 Diagnostic Tests, page 80 SAN Switch 2/8 Version 3.1.x Installation Guide 69 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 70
is normal and does not indicate a problem. Note: Any errors related to LED activity are listed in the error log. For information about the error log, refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures Guide. Front Panel LEDs The SAN Switch 2/8 front panel includes the following - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 71
. 2. Clear error log. 3. Rerun diagnostics to verify error condition is fixed. Check media and cable. No action required. Verify correct device is connected to port. SAN Switch 2/8 Version 3.1.x Installation Guide 71 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 72
(via the PortEnable command; refer to the HP StorageWorks Fabric OS Reference. 1. Check port status LEDs, error log, and cable or loopback plug. 2. Clear error log. Check configuration of Fibre Channel loop. No action required. No action required. 72 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 73
Managing the SAN Switch 2/8 Table 4: Front Panel LED Patterns During Normal Operation (Continued) . Recommended Action No action required. No action required. Verify switch is powered on, and Ethernet cable is firmly seated. No action required. SAN Switch 2/8 Version 3.1.x Installation Guide 73 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 74
. 1. Check error log, Port Status LEDs, port media, and cables or loopback plugs. 2. Clear error log. 3. Rerun diagnostics to verify error condition is fixed. 74 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 75
the advantage of being "virtually" in front of any fabric, switch, or port. For more information refer to the HP StorageWorks Web Tools Version 3.1.x/4.1.x User Guide. Note: The HP StorageWorks SAN Switch 2/8 EL and HP StorageWorks SAN Switch 2/8 power pak models offer a different set of integrated - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 76
Features Licensed features such as QuickLoop and Fabric Watch are already loaded onto the switch firmware, but must be enabled with a license key. Once you have purchased these features feature to activate. License keys are case sensitive. 76 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 77
Note: For security reasons, the first time you log into the Fabric OS you are requested to change the admin user ID and system password. 1. Log in to the switch as the admin user. 2. At the command line enter the following command: Password admin SAN Switch 2/8 Version 3.1.x Installation Guide 77 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 78
to 40 characters in length. 6. At the New Password prompt, enter the new password exactly as entered to the previous prompt. 7. Press Enter to commit the configuration to the firmware. Configuring the IP and Fibre Channel Address The SAN Switch 2/8 is shipped with a default IP address of 10.77.77.77 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 79
line enter the following command: nsAllShow This command displays a list of Fibre Channel addresses for all devices in the fabric. Checking the Firmware Version Use these steps to display the SAN Switch 2/8 firmware version. 1. Log in to the switch as the admin user. 2. At the command line enter the - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 80
returned to your switch supplier for repair. Any errors detected during POST are written to the system log, accessible through the errShow command. For more information about error messages, refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures User Guide. 80 SAN Switch 2/8 Version - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 81
diagnostic tests and how to run them, refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures User Guide. Note: The transmit and receive speed of the links may be temporarily locked to a specific speed during diagnostic testing. SAN Switch 2/8 Version 3.1.x Installation Guide 81 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 82
Managing the SAN Switch 2/8 82 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 83
Settings and Upgrading Firmware 4 This chapter provides the following information: ■ Backing Up System Configuration Settings, page 84 ■ Upgrading or Restoring the Switch Firmware, page 86 ■ Downloading Firmware from the HP Website, page 86 SAN Switch 2/8 Version 3.1.x Installation Guide 83 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 84
prompts you for each parameter, as follows: Example: switch:admin> configupload Server Name or IP Address [host]: 123.45.678.901 User Name [user]: kelev File Name [config.txt]: switch1 Protocol (RSHD or FTP) [rshd]: ftp Password: upload complete 84 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 85
path location and filename of the system configuration file, and password is the password for the user ID specified. Note: The password operand is only required if you are using FTP. 5. Reboot the switch by entering the following command: fastBoot SAN Switch 2/8 Version 3.1.x Installation Guide 85 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 86
the following command: fastBoot Downloading Firmware from the HP Website To download the firmware from the HP website, go to http://www.hp.com. The website contains the required loaders and instructions for downloading the firmware to a switch. 86 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 87
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a FCC could void the user's authority to operate the equipment. SAN Switch 2/8 Version 3.1.x Installation Guide 87 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 88
Noise Declaration Schalldruckpegel Lp = 46.1 dB(A)Am Arbeitsplatz (operator position) Normaler Betrieb (normal operation)Nach ISO 7779:1999 (Typprüfung) VCCI EMC Statement (Japan) 88 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 89
Harmonics Conformance (Japan) BSMI EMC Statement (Taiwan) Regulatory Compliance Notices RRL EMC Statement (Korea) SAN Switch 2/8 Version 3.1.x Installation Guide 89 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 90
with native Fibre Channel adapters, this product contains a laser internal to the small form factor pluggable (SFP) transceiver modules. In the USA, the SFP module is certified as a Class 1 Laser product, conforming to the requirements contained in Department Of Health and Human Services (DHHS - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 91
replacement or proper disposal, contact your HP authorized reseller or your authorized service provider. WARNING: Your switch contains an internal lithium manganese dioxide system or return them to HP, your authorized HP partners, or their agents. SAN Switch 2/8 Version 3.1.x Installation Guide 91 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 92
Regulatory Compliance Notices 92 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 93
removing them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. SAN Switch 2/8 Version 3.1.x Installation Guide 93 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 94
mats. ■ Use conductive field service tools. ■ Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an HP authorized reseller install the part. 94 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 95
covers the following topics: ■ Dimensions, page 96 ■ Power Supply Specifications, page 96 ■ Environmental Requirements, page 97 ■ Memory Specifications, page 97 ■ Serial Port Specifications, page 98 C SAN Switch 2/8 Version 3.1.x Installation Guide 95 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 96
Technical Specifications Dimensions Table 6 lists SAN Switch 2/8 dimensions. Table 6: Physical Specifications Dimension Height Depth Width Weight (with both power supplies) Value start at 25 degrees Celsius Fused in both hot & neutral lines 96 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 97
MB per switch ■ Flash Memory: Dual 8 MB ■ Boot Flash: 512K bytes of 8-bit for system boot The centralized memory maximizes the overall switch throughput by guaranteeing full transmit and receive bandwidth to all Fibre Channel ports at all times. SAN Switch 2/8 Version 3.1.x Installation Guide 97 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 98
port requires a straight Serial cable with a female 9-pin subminiature-D connector. Only pins 2, 3, and 5 are supported; if pin 7 is used, the signal must always be driven high, using the pinouts listed in Table 9. the Serial port is not in use. 98 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 99
to interface with a set of services. Arbitrated Loop A shared 100 MBps or 200 MBps Fibre Channel transport structured as a loop. Can support up to 126 devices and one fabric any-to-any connectivity, and allows nodes to transmit simultaneously. SAN Switch 2/8 Version 3.1.x Installation Guide 99 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 100
more interconnected Fibre Channel switches. The switch and switch components are mounted. Circuit An established communication path between two ports. Consists of two virtual circuits capable of transmitting in opposite directions. See also Link. 100 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 101
. Credit As applies to Fibre Channel, the number of receive SAN switches, a unique number between 1 and 239 that identifies the switch to the fabric and is used in routing frames. Usually automatically assigned by the switch, but can be manually SAN Switch 2/8 Version 3.1.x Installation Guide 101 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 102
be referred to as a switched fabric. See also Topology, SAN, Cascade. FC-AL-3 The Fibre Channel Arbitrated Loop standard defined by ANSI. Defined on top of the FC-PH standards. FC-FLA The Fibre Channel Fabric Loop Attach standard defined by ANSI. 102 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 103
onto Fibre Channel. Fibre Channel Transport A protocol service that supports communication between Fibre Channel service providers. FL_Port Fabric Loop Port; a port that is able to transmit under fabric protocol and also has arbitrated loop capabilities. Can be used to connect an NL_Port to a switch - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 104
and maintain bit, byte, and word synchronization. ISL Interswitch Link; a Fibre Channel link from the E_Port of one switch to the E_Port of another. See also E_Port, Cascade. Isolated E_Port An protocol definition or upper-level protocol mapping. 104 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 105
Link Services A protocol for link-related actions. Link As applies to Fibre Channel, a Fibre Channel port or to another N_Port in a point-to-point connection. NAA Network Address Authority. An identifier that indicates the format of a network address. SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 106
. Point-to-point A Fibre Channel topology that employs direct links between each pair of communicating entities. See also Topology. Port Cage The metal casing extending out of the optical port on the switch, and in which the SFP can be inserted. 106 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 107
Fibre Channel port. Communicated during login and port discovery. POST Power On Self-Test; a series of tests run by a switch after it is turned on. Private Device A device that supports a frame can be delayed in the fabric and still be delivered. SAN Switch 2/8 Version 3.1.x Installation Guide 107 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 108
as being part of a particular exchange. SAN Storage Area Network; a network of systems and storage devices that communicate using Fibre Channel protocols. See also Fabric. Sequence A group of related frames transmitted in the same direction between two N_Ports. Service Rate The rate at which an - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 109
Glossary Switch Hardware that routes frames according to Fibre Channel protocol and is controlled by software. Target A storage device on a Fibre Channel network. Tenancy The time from when a port are connected by a different type of network. SAN Switch 2/8 Version 3.1.x Installation Guide 109 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 110
Well-known Address As pertaining to Fibre Channel, a logical address defined by the Fibre Channel standards as assigned to a specific function, and stored on the switch. Workstation A computer used to access accessed by devices in the same zone. 110 SAN Switch 2/8 Version 3.1.x Installation Guide - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 111
user ID 77 changing the switch password 77 changing the user id 77 chassis 19 checking license 24 checking POST results 56 checking results 56 checking the firmware version 79 cli 75 cli errors for four switch limitation 25 SAN Switch 2/8 Version 3.1.x Installation Guide Index Index command line - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 112
summary 24 four switch limitation, CLI errors 25 front panel 70 front panel connectors 20 full fabric license 27 G gateway address 59, 78 getting help 15 grounding methods 94 H hardware features 19 help, obtaining 15 HP authorized reseller 16 storage website 15 technical support 15 hyperterminal 58 - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 113
humidity 97 restoring 85 SAN Switch 2/8 Version 3.1.x Installation Guide restoring configuration settings 85 Storage Area Network 17 installing multiple switches 67 subnetmask 78 switch cascading 68 switch location requirements 30 symbols in text 11 symbols on equipment 12 T technical support, HP - HP StorageWorks 2/8-EL | SAN Switch 2/8 V3.1.x - Installation Guide - Page 114
57 violation timer errors 26 voltage capability 31 W warning rack stability 14 symbols on equipment 12 web tools 25 web tools summary 75 websites HP storage 15 weight 96 workarounds for the four switch limitation 27 Z zoning summary 18 114 SAN Switch 2/8 Version 3.1.x Installation Guide
installation
guide
hp
StorageWorks
SAN switch 2/8
version 3.1.x
Product Version:
3.1.x
Third Edition (June 2003)
Part Number:
AA-RSB6C-TE
This installation guide provides basic procedures for setting up, configuring, and managing the
SAN Switch 2/8 EL and SAN Switch 2/8 power pak models.