HP StorageWorks 2/8-EL SAN Switch 2/8 V3.1.x - Installation Guide - Page 25

Four Switch Limitation CLI Error Messages, shows a typical Web Tools Warning Message.

Page 25 highlights

Installing the SAN Switch 2/8 Four Switch Limitation CLI Error Messages If the fabric detects that the four switch limitation has been exceeded, the following message occurs every thirty seconds, via the Command Line Interface (CLI): CRITICAL FABRIC-SIZE_EXCEEDED, 1, Critical fabric size exceeds supported configuration . Switch status marginal. Contact Technical Support. WebTools will be disabled in 39 days 8 hours and 46 minutes. The switch warning messages may be stored in the Syslog. Third-party application SNMP traps may be configured on the switch. Four Switch Limitation Web Tools Error Messages If the fabric detects that the number of switches installed exceeds the four switch limit, Web Tools displays a warning message every 75 seconds (not configurable). Figure 3 shows a typical Web Tools Warning Message. Figure 3: Four switch limitation Web Tools error message Note: The SAN Switch 2/8 EL displays a separate error condition warning message in the dialog box. SAN Switch 2/8 Version 3.1.x Installation Guide 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Installing the SAN Switch 2/8
25
SAN Switch 2/8 Version 3.1.x Installation Guide
Four Switch Limitation CLI Error Messages
If the fabric detects that the four switch limitation has been exceeded, the
following message occurs every thirty seconds, via the Command Line Interface
(CLI):
CRITICAL FABRIC-SIZE_EXCEEDED, 1, Critical fabric size <8>
exceeds supported configuration <4>. Switch status marginal.
Contact Technical Support.
WebTools will be disabled in 39 days 8 hours and 46 minutes.
The switch warning messages may be stored in the Syslog. Third-party
application SNMP traps may be configured on the switch.
Four Switch Limitation Web Tools Error Messages
If the fabric detects that the number of switches installed exceeds the four switch
limit, Web Tools displays a warning message every 75 seconds (not
configurable).
Figure 3
shows a typical Web Tools Warning Message.
Figure 3:
Four switch limitation Web Tools error message
Note:
The SAN Switch 2/8 EL displays a separate error condition warning message
in the dialog box.