Documentation Updates HP StorageWorks SAN Switch 2/8V and 2/16V Installation Guide On page 32, Table 6: Rack mount kit rails and rail mounting hardware: ■ Remove the following screw description: (14) #8-32 x 3/16-inch Phillips pan-head screw with thread lock ■ Insert the following screw descriptions: (14) 8-32 x 5/16-inch Phillips pan-head SEMS screw for use with the SAN Switch 2/8, SAN Switch 2/8V, SAN Switch 2/16, SAN Switch 2/16V and SAN Switch 2/16N (14) #8-32 x 3/16-inch Phillips pan-head screw with thread lock for the SAN Switch 2/32 HP StorageWorks Fabric OS 4.2.x Command Reference Guide The following commands have been modified: ■ configure ■ portCfgGPort ■ portCfgLongDistance ■ portCfgislMode Each change is detailed in the sections that follow. configure Change the Domain, R_A_TOV, and E_D_TOV fields as follows: Field Domain R_A_TOV E_D_TOV Default 1 10000 2000 Range Varies E_D_TOV * 2 to 12000 1000 to R_A_TOV / 2 portCfgLongDistance Add a Note regarding the portCfgislMode command, as follows: Note: portCfgislMode and portCfgLongDistance cannot both be enabled at the same time; otherwise, fabric segmentation occurs. 18 SAN Switch 2/8V, 2/16V, 2/16N Fabric OS 4.2.x Release Notes