53-1000599-02 12 March 2008 Fabric OS Command Reference Manual Supporting Fabric OS 6.1.0 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 2
owners. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 3
brocade.com Document History The table below lists all versions of the Fabric OS Command Command Reference 53-0000519-08 Fabric OS Command Reference 53-0000519-08 Rev. A Fabric OS Command Reference 53-0000519-09 Fabric OS Command Reference 53-0000519-10 Fabric OS Command Reference 53-0000519-12 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 4
13 new commands, Updated 23 commands with new options in support of v6.0. Removed 46 obsolete commands. Edit/revise ~ 150 commands. Added command syntax new commands, Updated 28 commands to support new v6.1 functionality. Removed 20 obsolete commands. Corrected errors in ~150 commands. Updated - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 5
feedback xxv Chapter 1 Using Fabric OS Commands Understanding role-based access control 1 Understanding admin domain restrictions 2 Using the command line interface 2 Chapter 2 Fabric OS Commands aaaConfig 5 ad 9 ag 19 agshow 30 aliAdd 32 aliCreate 33 aliDelete 34 aliRemove 35 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 6
cfgDelete 59 cfgDisable 60 cfgEnable 61 cfgMcdtmode 62 cfgRemove 63 cfgSave 64 cfgSaveActiveToDefined 65 cfgShow 66 cfgSize 68 cfgTransAbort 70 cfgTransShow 71 chassisConfig dbgShow 99 defZone 100 diagClearError 102 diagDisablePost 103 vi Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 7
Fabric OS Command Reference 53-1000599-02 diagEnablePost 104 diagHelp 105 diagPost 106 diagRetry 107 diagSetBurnin 108 diagSetCycle 109 diagShow 110 diagSkipTests 111 diagStopBurnin 112 dbgShow 113 distribute - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 8
ficonClear 191 ficonCupSet 192 ficonCupShow 194 ficonHelp 196 ficonShow 197 fipsCfg 203 firmwareCommit 206 firmwareDownload 207 firmwareDownloadStatus 212 firmwareKeyShow 215 firmwareKeyUpdate 216 viii Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 9
Fabric OS Command Reference 53-1000599-02 firmwareRestore 218 firmwareShow 219 fosConfig 220 fruReplace 222 fspfShow 223 fwAlarmsFilterSet 225 fwAlarmsFilterShow 226 fwClassInit 227 fwConfigReload 228 fwConfigure 229 fwFruCfg - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 10
326 licenseRemove 328 licenseShow 329 linkCost 330 login 332 logout 333 lsanZoneShow 334 lsDbShow 336 memShow 339 miniCycle 340 msCapabilityShow 345 msConfigure 346 x Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 11
Fabric OS Command Reference 53-1000599-02 msPlatShow 348 msPlatShowDBCB 349 msPlClearDB 350 msPlMgmtActivate 351 msPlMgmtDeactivate 352 msTdDisable 353 msTdEnable 354 msTdReadConfig 355 myId 356 nbrStateShow 357 nbrStatsClear - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 12
portCfgShow 464 portCfgSpeed 470 portCfgTrunkPort 471 portCfgVEXPort 472 portCmd 475 portDebug 479 portDisable 480 portEnable 481 portErrShow 482 portFlagsShow 483 portLedTest 484 xii Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 13
Fabric OS Command Reference 53-1000599-02 portLogClear 485 portLogConfigShow 486 portLogDisable 487 portLogDump 488 portLogDumpPort 489 portLogEnable 490 portLogEventShow 491 portLoginShow 492 portLogPdisc 493 portLogReset 494 portLogResize - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 14
slotPowerOn 602 slotShow 603 snmpConfig 606 spinFab 613 sshUtil 616 statsClear 620 stopPortTest 621 supportFfdc 622 supportFtp 623 supportSave 625 supportShow 629 xiv Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 15
Fabric OS Command Reference 53-1000599-02 supportShowCfgDisable 631 supportShowCfgEnable 632 supportShowCfgShow 633 switchBeacon 634 switchCfgPersistentDisable 635 switchCfgPersistentEnable 636 switchCfgSpeed 637 switchCfgTrunk 638 switchDisable 639 switchEnable 640 switchName - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 16
713 zoneObjectRename 714 zoneRemove 715 zoneShow 716 Primary FCS commands Primary FCS commands 717 Control Processor Commands Commands supported on the standby CP 719 Command availability Command validation checks 721 Command RBAC permissions and AD types 722 xvi Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 17
This document is a command reference manual written to help system administrators and technicians operate, maintain, and troubleshoot Brocade storage area network (SAN) products. "About this document" contains the following sections: • "How this document is organized," next • "Supported hardware and - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 18
Brocade 300 switch • Brocade 4016 switch • Brocade 4018 switch • Brocade 4020 switch • Brocade 4024 switch • Brocade 4100 switch • Brocade 4900 switch • Brocade 5000 switch • Brocade 5100 switch • Brocade 5300 switch • Brocade 7500 SAN router • Brocade 7600 switch • Brocade 48000 director • Brocade - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 19
Help pages are removed from the manual when the associated commands are deprecated or no longer supported on v6.1.0 platforms. • diagEnv (Not supported on v6.x platforms.) • diagFailLimit (Not supported on v6.x platforms.) • diagStatus (Not supported on v6.x platforms.) • fabStateClear (Deprecated - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 20
titles code text Identifies CLI output Identifies syntax examples For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In examples, command lettercase is all lowercase. If there are exceptions, this manual specifically - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 21
, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential SAN-specific terms, visit the Storage Networking Industry Association online dictionary at http://www.snia.org/education/dictionary. Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 22
to instantly scale the fabric by provisioning additional ports via license key upgrade (applies to some models of switches.) • Brocade Extended Fabrics - Provides up to 500 km of switched fabric connectivity at full bandwidth over long distances. xxii Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 23
(for the Brocade 7500 and FR4-18i blade in the Brocade 48000 and DCX backbone). • NPIV - N-port ID Virtualization, allowing up to 256 virtual addresses per physical port. This feature is supported only on the Brocade 200E and Brocade 300 in Access Gateway mode. Fabric OS Command Reference xxiii - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 24
the top of the switch module • Brocade 4018-On the top of the blade • Brocade 4020 and 4024-On the bottom of the switch module • Brocade 300, 4100, 4900, 5100, 5300 and 7500-On the switch ID pull-out tab located inside the chassis on the port side on the left • Brocade 5000-On the switch ID pull-out - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 25
If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the nonport side of the chassis - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 26
xxvi Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 27
Chapter 1 This chapter explains how to manage a Brocade SAN and Brocade switches and directors using the Fabric OS command line interface (CLI). The following topics discussed: • "Understanding role-based access control" on page 1 • "Understanding admin domain restrictions" on page 2 • "Using - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 28
commands included in this manual. Using the command line interface The Fabric OS command line interface (accessed via Telnet, SSH, or serial console) provides full management capability on a Brocade switch. The Fabric OS CLI enables an administrator to monitor and manage individual switches, ports - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 29
includes a synopsis of its syntax, a description of command use, and a set of examples. The same information can be accessed by issuing help command on a Brocade switch or director. This command displays the help page for the specified command. For example, to display the help page for ad, type - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 30
1 Using the command line interface 4 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 31
can use centralized RADIUS servers to manage AAA services for a switch, as defined in RFC 2865. Fabric OS v6.1.0 or later is required to configure LDAP while in FIPS mode. Refer to the Fabric OS Administrator's Guide for configuration procedures. This command can be executed when logged in through - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 32
supported. If a name is used, a DNS entry must be correctly configured for the server. The command the current AAA service configuration. --add brocade.com. This option is valid only with the -conf ldap option. This option is required. -s secret Specifies a common secret between the switch - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 33
configuration as either RADIUS or LDAP. If the server is enabled, the command does not allow the last server to be removed from the configuration AAA services. Services must be enclosed in double quotation marks. The following AAA services and service pairs are valid: "local" Default setting. - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 34
if none of the primary AAA services are available. Displays command usage. Examples To display the current RADIUS configuration: -- switch:admin> aaaconfig --show RADIUS CONFIGURATIONS Position Server Port Secret Timeout(s) Auth-Protocol 1 192.168.233.48 1812 sharedsecret 3 2 192.168.233 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 35
. Before creating Admin Domains, the default zone mode should be set to "No Access". To set the default zone mode to "No Access" execute the following command sequence: switch:admin> ad --select AD0 switch:admin> defzone --noaccess switch:admin> cfgsave Refer to defZone help for more information - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 36
2 ad All switches, switch ports and devices in the fabric that are not specified in any syntax for this command is "ad action arguments". Command actions are described first. Argument details follow the description of actions. The following actions are supported: --activate arg Activates - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 37
transaction to the defined configuration on all switches in the fabric. The saved Admin Domain definition is enforced only when ad --apply is issued. Attempts to modify and save an Admin Domain that is currently enforced will fail. The command prompts for confirmation. --select arg Selects an - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 38
context, the command, by default Domain aware switch or the from non-Admin Domain aware switches are marked with a plus switch WWN specified in an AD switch The command prompts The following arguments are supported with selected AD --validate actions. For all command iterations, with the exception of - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 39
Admin Domain. Uses traditional zone WWN member types. Benefits include: • Supports node or port WWNs. • End-device members, whose WWNs are used in an Admin switch. Ownership of a switch implicitly provides port control capability on all its ports, but no zoning control. Specifies one or more commands - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 40
05" -s "100; 10:00:00:60:69:80:59:13" To deactivate Admin Domain 5: switch:admin> ad --deactivate 5 You are about to deactivate an AD. This operation will fail if n): [no] y To delete AD13: switch:admin> ad --delete 13 You are about to delete an AD. 14 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 41
:admin> ad --select 12 To display all ADs: switch:admin> ad --show Current AD: 255 : AD255 Transaction buffer configuration no configuration Defined configuration AD: 1 : AD1 Active Device WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; Fabric OS Command Reference 15 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 42
AD: 1 : AD1 Active Device WWN members: Switch port members: Switch WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; 1,0; 1,1; 1,2; 1,3; 1,4; 1,5; 1,6; 1,7; 1,8; 1,9; 1,10; 1,11; 1,12; 1,13; 1,14; 1,15; 10:00:00:60:69:00:02:53; Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 43
: 10:00:00:06:2b:12:68:2b; 10:00:00:06:2b:12:68:3f; 1,8; 69,16; AD Number: 3 AD Name: AD3 State: Inactive Device WWN members: Switch port members: 11:22:33:44:55:66:77:88*; 10:00:00:06:2b:12:64:54; 3,28; 3,29; 3,30; 3,31; 69,16; 69,18; 69,19; 69 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 44
2 ad Device WWN members: Switch port members: 10:00:00:00:00:17:00:00; 10:00:00:00:00:15:00:00; 2,52; 2,53; 2,54; 2,55; 21,5; 3,28; 3,29; 98,72; 98,75; 69,16; 69,18; 69,21; 1,336; 1,337; AD Number: 55 AD Name: AD55 State: Inactive Device WWN members: 10 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 45
or delete N_Ports in Port group. • Display all policies and their status. • Enable or disable Auto Port configuration policy. • Enable or disable preferred Secondary N_Port policy. • Enable, disable, and manage Advanced Device Security (ADS) policy. Fabric OS Command Reference 19 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 46
changes are saved persistently as config keys. Use the portCfgnPort command to set a port as N_Port. Notes AG is supported only on selected Brocade hardware platforms. Refer to the Access Gateway Administrator's Guide for Hardware support and AG configuration procedures. In non-AG mode, the only - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 47
applies to all the ports on the switch. By default all devices have access to the fabric on all ports. --policydisable policy Disables the specified policy for the Access Gateway. When a policy is disabled, all port-related configuration settings are lost. Use the configUpload command to save the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 48
marks. Ports must be separated by semicolons. Maximum numbers of ports allowed in a port group is MAX_PORT. Port Group ID must not exceed 64 characters. --failovershow [N_Port] If N_Port is specified (optional), the command displays the failover policy for this N_Port. Otherwise, the failover - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 49
set of F_Ports. Devices are specified by their world wide names Lists must be enclosed in double quotation marks. List members must be separated by semicolons. The maximum number of entries in the allowed device list is twice the per port must be enabled for this command to succeed. --adsadd "F_Port - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 50
AG show commands 1. To displays the current state of the Access Gateway with Failover (FO) and Failback (FB) enabled on N_Ports 9 and 12: switch:admin> ag --show Name : switch_ST1 NodeName : 10:00:00:05:1e:35:9b:e7 Number of Ports : 16 IP Address(es) : 10.115.74.53 Firmware Version : v6 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 51
:admin> ag --modeshow Access Gateway mode is NOT enabled. AG group policy commands 1. To show current policies: switch:admin> ag --policyshow Policy_Description Policy_Name State Port Grouping pg Enabled Auto Port Configuration auto Disabled Advanced Device Security ads Disabled - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 52
SecondFabric 3 12;13 12;13 0 1 0 pg0 6. To delete F_Port 5 that was mapped to N_Port 2: switch:admin> ag --mapdel 2 "5" Preferred N_port is set for F_Port[s] Please delete it before removing primary N_Port ERROR:Unable to remove F_Port[s] from mapping, retry the command switch:admin> ag - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 53
been updated successfully NOTE: Preferred Port commands are discussed in detail below. AG failover policy commands 1. To display failover policy settings for all N_Ports: switch:admin> ag --failovershow N_Port failover_bit 0 1 1 0 2 1 3 0 2. To set and display failover and failback - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 54
pgshow PG_ID N_Ports PG_Name 0 0;2 pg0 3 1;3 FirstFabric AG Preferred port information commands 1. To display preferred port settings for F_Ports: switch:admin> ag --prefshow F_Ports Preferred N_Port 10;11 0 12;13 1 4;6 2 28 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 55
To set secondary port mapping for F_Ports 7, 8 and 9: switch:admin> ag --prefset "7;8;9" 3 Preferred N_Port is set successfully for the F_Port[s] ADS Policy commands 1. To set the list of allowed devices for Ports 11 and 12 to 'no access': switch:admin> ag--adsset"11;12""" WWN list set successfully - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 56
34:e4:bd N-Port ID(s) : 0x010200 Number of Ports : 16 IP Address(es) : 10.202.90.231 Firmware Version : v1.0.0 N-Ports : 1 F-Ports : 2 Attached F-Port information: PortID Port WWN 0x010208 10:00:00:00:c9:3f:7c:86 0x01020a 10:00:00:00:c9:3f:7c:b9 30 Fabric OS Command Reference 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 57
:00:05:1e:04:06:ae 24 10.32.173.64 v6.0.0 local L5D2_B14_4024_1 See Also To display all Access Gateways attached to the fabric: switch:admin> agshow Worldwide Name Ports Enet IP Addr Firmware Local/Remote Name 10:00:00:05:1e:02:b7:2c 16 10.32.173.62 v6.0.0 remote L5D2_B10_4016_1 10:00:00 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 58
must be separated by semicolons. An alias member can be specified by one or more of the following methods: • A switch domain and port area or index number pair. Use switchShow for a list of valid port area or index numbers. • WWN Examples To add members to zone aliases array1, array2, and loop1 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 59
command for more information on name and member specifications. This command switch domain and port area or index number pair. Use switchShow for a list of valid port area or index numbers. • WWN Examples To create a zone alias: switch:admin> alicreate "array1", "2,32; 2,33; 2,34" switch - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 60
reboots, save the zone configuration to nonvolatile memory with the cfgSave command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operand is required: "aliName" Specify the name of the zone alias to be deleted. This operand - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 61
cfgSave command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command of the following methods: • A switch domain and port area or index number pair. Use switchShow for a list of valid port area or index numbers. • WWN The member - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 62
zone alias names in the defined configuration. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands When invoked without operand, this command displays all zone configuration information (defined and effective). Refer to cfgShow for a description - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 63
the current list of advanced performance tuning (APT) policies supported on this switch, as well as the current policy. This command has the following operand: ap_policy Specifies the APT policy. The following polices are supported: 1 Port-based routing policy. With this policy, the path chosen - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 64
:admin> switchenable switch:admin> aptpolicy Current Policy: 3 1(ap) 3 0(ap): Default Policy 1: Port Based Routing Policy 3: Exchange Based Routing Policy 0: AP Shared Link Policy 1: AP Dedicated Link Policy See Also dlsReset, dlsSet, dlsShow, switchDisable 38 Fabric OS Command Reference 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 65
to configure and display the audit log configuration. This command allows you to set filters by configuring certain classes, to add or remove any of the classes in the filter list, and to enable or disabled the filters. Based on the configuration, certain classes are logged to syslog for auditing - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 66
this command to display and set local switch authentication parameters. Use --set to change , used on the port. Note The execution of this command is subject to Admin command displays the usage. The following operands are supported: --show Displays local authentication configuration. --set - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 67
FIPS. Refer to the Fabric OS Administrator's Guide for details on FIPS configuration. --policy Sets the switch authentication policy or device authentication policy. The following options are supported: -sw on|off|active|passive Sets the switch authentication policy. Specify one of the following - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 68
y Device authentication is set to PASSIVE To start authentication on E/F_Ports 2, 3, and 4: switch:admin> authutil --authinit 2,3,4 To disable md5 hash type for FIPS configuration: switch:admin> authutil --show AUTH TYPE HASH TYPE GROUP TYPE 42 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 69
: OFF switch:admin> authutil --set -h sha1 Hash is set to sha1. switch:admin> authutil --show AUTH TYPE HASH TYPE GROUP TYPE fcap,dhchap sha1 1 Switch Authentication Policy: PASSIVE Device Authentication Policy: OFF portShow, secAuthSecret authUtil 2 Fabric OS Command Reference 43 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 70
the banner on the local switch. Synopsis bannerset [banner] Description Use this command to set the banner on the local switch. The banner is a string of alphanumeric characters. It is displayed whenever you log in to a switch. The banner can be created using the banner operand or by entering - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 71
Displays the banner text. Synopsis bannershow Description Use this command to display the contents of the banner. Operands none Examples To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 72
In this example, from a switch with 128 ports, the member ports consist of ports 7, 13, 42, 84, 85, and 86. The final Member Ports bit set represents the embedded port (frames sent to be handled by firmware) and is typically set. See Also portRouteShow 46 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 73
, or displays the current mode. Synopsis bladebeacon slotnumber [mode] Description Use this command to enable or disable blade beaconing or to display the current beaconing mode for one blade. When beaconing is enabled, the port LEDs flash amber in a running pattern from bottom to top and top to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 74
Description Use this command to disable all user ports on a blade. All ports on the blade are taken offline. If the switch was connected to a fabric through this blade, the remaining switches reconfigure, and this switch will configure based on the other blade ports. The blade must be disabled - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 75
, or amber for ports that do not initialize. Notes A blade cannot be disabled or enabled when the switch is disabled or when the blade itself is faulted, powered off, or running diagnostics. Persistently disabled ports are not enabled by this command. The execution of this command is subject to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 76
Also 2 UNKNOWN VACANT 3 UNKNOWN VACANT 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT bladeDisable, portDisable, portEnable, switchShow 50 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 77
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands The following operand is required: slotnumber Specify in errors from slot 2: switch:admin> burninerrclear 2 See Also burninErrShow Fabric OS Command Reference 51 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 78
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands The following operand is required: slotnumber burn-in errors from slot 2: switch:admin> burninerrshow 2 See Also burninErrClear 52 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 79
display the burn-in level. When you set the burn-in level to a value other than 0, this command behaves as follows: 1. The diagnostic daemon program performs burn-in testing in place of the power-on self-test (POST) phase II each time a switch blade is powered on. 2. The burn-in test stores errors - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 80
command to display the burn-in status of blade in a specified slot. Command output includes the slot number, state, current run number, current command in the run, total commands Examples To display the burn-in status for all slots: switch:admin> burninstatus Slot State Status Run 1 ABORT PASS 3 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 81
cfgactvshow Description Use this command to display the effective The devices that an initiator sees are based on this configuration. The effective configuration Examples To display the effective zone configuration information: switch:admin> cfgactvshow Effective configuration: cfg: c4 zone: - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 82
. For the change to take effect, enable the configuration with the cfgEnable command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operands are required: "cfgName" Specify a name for the zone configuration, in quotation - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 83
re-creates the default zoning objects. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands none Examples To clear all zones and then clear nonvolatile memory: switch:admin> cfgclear The Clear All action will clear all Aliases, Zones, FA Zones - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 84
reboots, save the configuration to nonvolatile memory with the cfgSave command. Notes When FCS policy is enabled, this command can be issued only from the primary FCS switch. Refer to the zoneCreate command for more information on name and member specifications. Operands The following operands - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 85
For the change to become effective, enable the configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the configuration to nonvolatile memory with the cfgSave command. Note When FCS policy is enabled, this command can be issued only from the primary FCS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 86
both volatile and nonvolatile memory. If a transaction is open on a different switch in the fabric when this command is run, the transaction on the other switch is automatically aborted. A message displays on the other switches to indicate that the transaction was aborted. If the default zone access - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 87
for a description of defined and effective configurations. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operand is required: "cfgName" Specifies the name of the zone configuration. The name must be enclosed in quotation - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 88
-wide, meaning that the feature is disabled or enabled on all switches in the fabric. Note This command is effective only when the Brocade switch or director is in McDATA fabric mode. Operands This command has the following operands: --enable Enables McDATA zoning features. --disable Disables - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 89
For the change to become effective, enable the configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the configuration to nonvolatile memory with the cfgSave command. Note When FCS policy is enabled, this command can be issued only from the primary FCS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 90
command writes the defined configuration and the name of the effective configuration to nonvolatile memory in all switches in the fabric. The saved configuration is automatically reloaded at power , cfgRemove, cfgShow, cfgTransAbort, cfgTransShow 64 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 91
replaced. Any non-duplicate zone sets or zones remain unchanged. Note This command is only effective when the Brocade switch/director is in McDATA fabric mode. Operands The cfgSaveActiveToDefined command has no operands. Examples Execute the cfgShow command to view defined and effective zoning - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 92
that has not yet been saved. If the local switch has no outstanding transaction, this command displays the committed zone configuration. If a pattern is specified, only matching confirgurations are displayed. The defined configuration is the complete set of all zone objects that have been defined in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 93
:20:37:0c:71:df To display only configuration names: switch:admin> cfgshow "*" cfg: USA1 Blue_zone cfg: USA_cfg Red_zone; Blue_zone See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgTransAbort, cfgTransShow Fabric OS Command Reference 67 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 94
to ad for a description of defined and effective Admin Domain configurations. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operand is optional: integer If a nonzero integer is specified, the size of the nonvolatile memory - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 95
- 0 bytes cfgsize Info for AD Number:1 (AD Name: AD1, State=Active): committed - 16 bytes transaction - 0 bytes cfgsize Info for AD Number:2 (AD Name: AD2, State=Active): committed - 4 bytes transaction - 0 bytes See Also ad, cfgShow, zoneHelp Fabric OS Command Reference 69 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 96
are removed and the zone configuration database is restored to the state before the transaction was started. If a transaction is open on a different switch in the fabric when this command is run, the transaction on the other switch remains open and unaffected. Note When FCS policy is enabled, this - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 97
zoning transaction. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands none Examples To display the current transaction: switch:admin> cfgtransshow There is no outstanding zone transaction switch:admin> cfgclear Do you really want to clear all - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 98
is currently configured as Option 1 (a single 128-port switch with Brocade blade IDs 4 and 17 and CP blade IDs 5 and 16), both CP blades should always contain firmware that supports this command. Use of earlier versions adversely affects switch operation. Because this is a disruptive operation and - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 99
command displays the current configuration option and a list of all valid options. Examples To display the current configuration option on a Brocade 48000 director and to change the option: switch:admin> chassisconfig Current Option: 5 All Supported Options Option 5: One 384-port switch Blade - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 100
sets the chassis name. Synopsis chassisname [name] Description Use this command to display or change the name associated with the chassis. Operands This command "dilbert": switch:admin> chassisname dilbert switch:admin> chassisname dilbert See Also switchName 74 Fabric OS Command Reference 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 101
the lines and their meaning. TABLE 1 Command output descriptions Line Description 1 If applicable, the first line displays the chassis backplane version number, in hexadecimal. 2 Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor), WWN (World Wide Name - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 102
: Revision Num: 1 -180 60-0001532-03 1013456800 Day: 12 Month: 6 Year: 2001 Day: 15 Month: 7 Year: 2001 28 days 16 days 555-374757 234-294-12345 2734658 A.00 CP BLADE Slot: 6 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: ID - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 103
512. Operands none Examples To display the command history on a switch: switch:admin> clihistory Command History: 09:14:17.6924 1 admin, 192.168.163.233, version 10:25:36.8875 1 admin, 192.168.100.19, clihistory 12:05:40.3492 1 admin, 192.168.100.19, help | more 12:05:46.2940 1 admin, 192.168.100 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 104
Synopsis configdefault Description Use this command to reset a subset of configuration settings to their factory defaults. existing ones. When issuing configDefault on the Brocade 7500, it persistently disables the ports. The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 105
See Also snmpConfig, configure, switchDisable, switchEnable configDefault 2 Fabric OS Command Reference 79 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 106
service is available on Unix and Windows hosts. The third form of the configDownload command retrieves the configuration file from a predetermined directory on the local chassis or from an attached USB device. For Admin Domain users, refer to the Fabric OS Administrator's Guide a switch configuration - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 107
support IPv6. Once a configuration file has been uploaded to an external system, it must NOT be manually edited before being downloaded, either to the same or another switch. Such an operation bypasses sanity checks for some configuration datapoints, resulting in unpredictable behavior. This command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 108
[config.txt]: config.txt *** CAUTION *** This command is used to download a backed-up configuration for a specific switch. If using a file from a different switch, this file's configuration settings will override any current switch settings. Downloading a configuration file, which was uploaded - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 109
files stored on the local chassis: switch:admin> configlist -local config.txt config2.txt next_cfg.txt 25679 25679 20977 2007 Jan 02 15:16 2007 Jan 06 15:16 2007 Jan 18 15:16 See Also configDownload, configUpload, configShow, configRemove Fabric OS Command Reference 83 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 110
] Specify the configuration file to be removed. If the -file option is omitted, the command prompts you to specify a file name. Examples To remove a configuration file from the local chassis: switch:admin> configremove -local first_config.txt To remove a configuration file from an attached USB - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 111
operators is not supported. Some configuration settings do not display when filtered. If in doubt, use the command without operands. switch :admin> configshow -local File Name [config.txt]: config.txt [Switch cp7 Configuration uploaded on Aug 07 03:59:55] [FOS-Version: 6.0.0.0] Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 112
port.nfportfailback:0x0 ag.port.nfportfailover:0x0 ag.port.nfporttopo.0:0x0 ag.port.nfporttopo.1:0x0 ag.port.nfporttopo.10:0x0 [output truncated] To display selected content of the local configuration file: switch ipAddrShow, licenseShow, syslogdIpShow 86 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 113
| USB |-U ["file"] Description This command uploads the switch configuration to a host file. The first form of the configupload command uses FTP (File Transfer Protocol). The FTP Server must be running in the host before an upload can occur. The configUpload command supports DNS names, and also - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 114
the double-quote character ("). This applies to command-line mode and to the interactive mode. Once a configuration file has been uploaded to an external system, it must NOT be manually edited before being downloaded, either to the same or another switch. Such an operation bypasses sanity checks for - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 115
file (Y/N)? [N]: y configUpload complete: All config parameters are uploaded To upload a local configuration file from the command line forcing an overwrite: switch:admin> configupload -local -force config.txt configUpload complete: All config parameters are uploaded See Also configDefault - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 116
this command to change the following system configuration settings for the switch: • Switch fabric settings • Virtual channel parameters • F_Port login parameters • Zoning operation parameters • Remote State Change Notifications (RSCN) transmission mode • Arbitrated Loop Parameters • System Services - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 117
1 10000 2000 0 7 2112 0 0 0 0 0 16 0 varies E_D_TOV * 2 to 120000 1000 to R_A_TOV / 2 0 to R_A_TOV / 4 7 to 19 256 to 2112 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 1 to 27 0 or 1 Fabric setting fields are defined as follows: Domain The domain number uniquely identifies a switch in a fabric. This value - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 118
(see Unicast-only Operation). Insistent Domain ID Mode When this mode is set, the switch attempts to acquire from the fabric the domain number programmed in its "Switch Fabric Settings." If the operation fails, the switch will segment from the fabric. 92 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 119
Range Maximum logins per switch Number Maximum logins per port Logins per second Login stage interval (milliseconds) Number Number Number 16 * the max 1 to 126 * the number of ports max number of ports 126 1 to 255 0 0 to 100 0 0 to 10000 Fabric OS Command Reference 93 53-1000599 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 120
1 Enabled. Domain RSCN is sent to the end-device for the switch IP address or name change. Arbitrated Loop Parameters The Arbitrated Loop Setting fields are described inTable 7. TABLE 7 Configure command arbitrated loop settings Field Default Send FAN frames? 1 Enable CLOSE on OPEN received - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 121
for firmware Basic User Enabled Perform License Checking and Warning Allow Fabric Event Collection string string number string boolean boolean boolean boolean boolean not set not set 128 none no no no yes yes varies varies 40, 56, 128 varies no/yes no/yes no/yes yes/no yes/no Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 122
0x0 to 0xffff system.blade.bladeFaultOnHwErrMsk If this field is set to a value other than 0, then any nonfatal HW ASIC data parity error causes the problem blade to be powered off. Examples To enable signed firmware download on a disabled switch: switch:admin> configure Configure... Fabric - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 123
command has the following operand: -seed value Specify the data pattern seed value. If no seed is specified, then a seed value of 0 is used. Examples To display sample data streams you can use with diagnostics: switch b0 60 c0 11 55 16 fc d7 17 65 a9 87 5f 44 be 5a d0 de bc a5 12 bc bc 23 47 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 124
distributed fabric-wide to its local time. Refer to tsTimeZone for more information on time zone support. If the switch is operating in FICON Management Server mode (fmsmode), setting the date is subject to the director clock alert mode (DCAM). If DCAM is 1, the operator issues a warning that the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 125
the debug and verbosity levels. Module names are case-sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg Fabric OS Command Reference 99 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 126
This command has the following operands: --noaccess Sets the command, the local switch converts this command to the equivalent of cfgEnable d_efault_Cfg. • If zoning receives a cfgDisable command from a remote switch that does not support default zoning, zoning rejects the cfgDisable command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 127
defZone 2 Examples See Also --allaccess Sets the default zone access mode to All Access, initiates a zoning transaction (if one is not already in progress), and deletes the reserved zoning objects by performing the equivalent to the following zoning commands: cfgDelete "d_efault_Cfg" zoneDelete - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 128
Availability" for details. Operands This command has the following operand: --slot slotnumber Specify the slot on which to clear the diagnostics failure status. The default is set to 0 and designed to operate on fixed-port-count products. -all If specified, all blades clear. If no operand is - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 129
may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To disable the POST during future power ons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 130
that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable the POST during future power ons: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See Also - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 131
settings require detailed knowledge of the underlying hardware and are intended for support personnel only. Contact support if you want to use these operands. Operands none Examples To display diagnostic command information: switch:admin> diaghelp bladepropshow chippropshow display blade - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 132
The mode becomes active as soon as this command is executed; it does not require a reboot to take effect. POST mode modifies the behavior of the diagnostics daemon program to inhibit testing of switch blades when the system is first powered on or a new blade is added. To enable or disable diagnostic - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 133
this operand to display the current mode setting. If no operand is specified, the current value is displayed. Examples To view the current retry mode value: switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. See Also none Fabric OS Command Reference 107 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 134
The errors produced are available from the burninErrShow command on a per-blade basis. When power cycles occur, the burn-in activity is restarted at run. -current Sets the name of the burn-in script to the current burn-in script. Examples To set the burn-in script and mode: switch:admin> diagsetburnin - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 135
this operand to set the script parameters to default values. -keyword value The script parameters can be updated noninteractively with the -keyword option. the specified value is the keyword to update. Examples To update diagnostic command parameters: switch:admin> diagsetcycle switchburnin - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 136
blade: switch:admin> diagshow Diagnostics Status: Fri Feb 08 15:25:24 2002 Slot: 1 UPORTS Port BPort Diag Active Speed ...... 0 15 OK UP 2G Auto ...... 1 14 OK UP 2G Auto ...... 2 13 OK UP 2G Auto ...... 3 12 OK UP 2G Auto ...... 4 31 OK UP 2G Auto ...... 5 30 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 137
This command has the following operands: value Specify a bit mask for tests to skip. -show If specified or no value is given, the current skip tests setting displays. If no operand is specified, the current value is displayed. Examples To display the current skip test flags: switch:admin - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 138
command to determine which PID is running burn-in on a blade and terminate that activity. The burn-in script handles the logging cleanup. This command , this command executes on all slots in the logical switch. This operand is optional. Examples To stop burn-in mode on a switch: switch:admin> - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 139
the debug and verbosity levels. Module names are case-sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg Fabric OS Command Reference 113 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 140
. Synopsis distribute -p policy_list -d switch_list Description Use this command to distribute data to a specified list of switches in the fabric. The distributed data must be from the list of currently supported policy sets: SCC Switch Connection Control Policy DCC Device Connection Control - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 141
and FCS policies to all switches in the fabric that run v5.3.0 or later: switch:admin> distribute -p "AUTH;FCS" -d "*" To distribute the AUTH and SCC policies to domains 1 and 3 in the fabric: switch:admin> distribute -p "AUTH;SCC" -d "1;3" fddCfg Fabric OS Command Reference 115 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 142
Admin Domain Restrictions" and Appendix A, "Command Availability" for details. DLS is not supported in certain routing policies. Refer to switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS is not set See Also aptPolicy, dlsSet, dlsShow 116 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 143
Optimal balance is rarely achieved with this setting. Notes DLS is not supported in certain routing policies. If supported, the DLS option is on by default. Refer to aptPolicy help for more information on routing policies. The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 144
DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing policies. The execution of this command is subject to A, "Command Availability" for details. Operands none Examples To display the current DLS option setting: switch:admin> dlsshow DLS is set See - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 145
Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To set the DNS parameters for the system: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 146
Use this command to display attributes of the switch enclosure. Supported attributes include the vendor-specific enclosure identifier and the identifier of the enclosure interface to which the switch is attached. This command is only meaningful for products that are embedded in a blade server or - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 147
instances on this control processor (CP). Synopsis errclear Description Use this command to clear all internal and external error log messages for all switch instances on this CP. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 148
Description Use this command to set the error log start switch:admin> errdelimiterset -s "Start" -e "End" Start2003/03/10-09:54:03, [NS-1002], 1035,, ERROR, SWITCH43, Name Server received an invalid request from device 10:02:32:A3:78:23:23:End errDump, errFilterSet, errShow 122 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 149
switch_instance][-r][-p] Description Use this command to display external error log messages for all switch instances and the chassis, , switch2, Security violation: Login failure attempt via SERIAL. See Also errDelimiterSet, errFilterSet, errShow Fabric OS Command Reference 123 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 150
destination. Synopsis errfilterset [-d "destination"][-v "severity"] Description Use this command to set a filter for an error log destination. A filter is set based on the severity level of the messages. If no parameters are specified, this command displays the filters that are currently in use - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 151
: switch:user> errmoduleshow Module IDs: 1 KT 2 UT 5 LOG 6 CDR 9 PIXE 10 EGR 13 PS 14 RTE 17 BLDE 18 BLM 21 CFLD 22 CFMN (output truncated) 3 TRCE 7 BLPU 11 BL 15 AS 19 BPRT 23 CHPS 4 KTRC 8 PISP 12 PIC 16 AUTH 20 CER 24 CONF See Also errDump, errShow Fabric OS Command Reference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 152
switch_instance][-r][-p] Description Use this command to display external error log messages for all switch instances and the chassis, failure attempt via SERIAL. Type to continue, Q to stop: See Also errDelimiterSet, errDump, errFilterSet 126 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 153
. Telnet and rlogin connections are closed; the serial port returns to the login: prompt. The exit command is an accepted synonym for logout, as is typing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 154
0x00000010 Overlapping zones 0x00000020 Done PTIO ioctl 0x00000040 Sent an RJT to ELP 0x00000080 BF received from the port 0x00000100 Port truly connected to E_Port 0x00000200 Segmented by routing code 0x00000400 FSPF has completed routing 128 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 155
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to display, followed by a slash (/). portnumber Specifies the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 156
display fabric port information: switch:admin> fabportshow 4/14 Fabric Port Information Port: State: List: List Count: Flags: nbrWWN: nbrPort: lr_tid: red_ports: 10 11 62 63 62 P3 0x10068418 0 0x280120 10:00:00:60:69:80:06:cf 5 0x1005dbd8, IDLE STATE Open commands pending No commands pending - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 157
commands. Synopsis fabretryshow Description Use this command to display the retry count of the fabric commands. The SW_ISL (ISL ports) information displays the retry count for the following fabric commands the retry count of Fabric OS commands: switch:user> fabretryshow SW_ILS E_Port ELP EFP HA_EFP - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 158
Changes the maximum number of log entries. The given size has to be at least 2 and a power of 2; otherwise, the command fails. Examples To change the number of entries: switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid Wed Apr 6 01:08:52 2005 01:08:52.977 SCN - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 159
fabricLog 2 See Also switch:admin> fabriclog -r 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid fabPortShow, fabStatsShow Fabric OS Command Reference 133 53- - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 160
mode. Synopsis fabricprincipal [-fhq] [mode] Description Use this command to set principal switch selection mode for the switch. The implementation of the fabricPrincipal command is based solely on mechanisms specified in the Fibre Channel standards. These mechanisms provide a preference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 161
Switch ID The switch Domain_ID and embedded port D_ID. World Wide Name The switch WWN. Enet IP Addr The switch Ethernet IP address for IPv4 and IPv6 configured switches. For IPv6 switches if the switch is not an FC Router or it the FC Router does not support it. Operands This command has the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 162
admin> fabricshow -m Switch ID Name ENET IP Addr FC Router FC Router IP Addr Name 1: fffc01 fcr_sprint_01 10.33.59.224 160: fffca0 fcr_fd_160 0.0.0.0 10.33.59.25 fcr_meteor2 190: fffcbe fcr_mojo_6 10.33.59.32 The Fabric has 3 switches switchShow 136 Fabric OS Command Reference 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 163
fabStatsShow 2 fabStatsShow Displays the fabric statistics. Synopsis fabstatsshow Description Use this command to display the statistics for the fabric. The following information is displayed: • Number of times a switch domain ID has been forcibly changed • Number of E_Port offline transitions - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 164
2 fabStatsShow Sec Incompatibility: 0 Sec Violation: 0 ECP Error: 0 Duplicate WWN: 0 Eport Isolated: 0 See Also fabRetryShow 138 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 165
outstanding: 0 EFP update port: 2 FWN frames pending 0 test check point: No check point set fabric license: TRUE fabric EFP version: 7 last message: 20:30:29.826 *Snd inquiry (4) D0,NA D0,NA NA NA (output truncated) See Also supportShow Fabric OS Command Reference 139 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 166
unit. Synopsis fandisable unit Description Use this command to disable a non-faulty fan unit by setting the RPM speed to 0. Notes This command is not available on non-bladed systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 167
. Synopsis fanenable unit Description Use this command to set a previously disabled fan unit back to the default RPM speed. Notes This command is not available on non-bladed systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 168
unit installed. faulty Fan has exceeded hardware tolerance and has stopped. In this case, the last known fan speed is displayed. The output from this command varies depending on switch type and number of fans present. Operands none Examples To display information on the fans in the system - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 169
significantly. If POST was previously disabled using the diagDisablePost command, then fastboot is the same as reboot. Notes This command is not available on non-bladed systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin Domain restrictions that may be - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 170
fastwritecfg to enable or disable FC fastwrite on the individual ports. Notes This command requires a High-Performance Extension over FCIP/FC license This command is supported only on the Brocade FC-IP/FC Router blade (FR4-18i) on a Brocade 7500, 48000 or DCX platform. When FC fastwrite is enabled - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 171
requires power-cycling of the affected blade to take effect and may take up to 5 minutes to complete. Non-bladed switches will be rebooted. In all cases, data traffic on all the ports (FC and GbE) of the blade will be disrupted. Continue (Y,y,N,n): [ n] portcfg Fabric OS Command Reference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 172
for details. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -testtype - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 173
is detected, the test might report one or more of the following error messages: CHIP_TEST_ERR CHIP_TEST_CHIP_INIT_ERR CHIP_TEST_IMAGE_VER_ERR CHIP_TEST_TIMEOUT_ERR CHIP_TEST_HEARBEAT_ERR CHIP_TEST_INVALID_RESULT See Also fcipPathTest Fabric OS Command Reference 147 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 174
To display FCIP command information: switch:admin> diaghelp fciphelp fastwritecfg portcfg portcmd portshow Configure FC fastwrite feature Create/Delete a new ip interface/route/arp entry or fcip tunnel on the GigE port Execute commands (ping etc) on the GigE port Show configured ip interfaces - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 175
" for details. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -unit - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 176
the test. By default, data compression is used. This setting is applicable only to path mode 1 and 2. Examples To run the test on slot 2 with PHY loopback sending 10 frames: switch:admin> fcippathtest --slot 2 -path 2 -nframes 10 Running fcippathtest Test Complete: Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 177
used for any LUN query from this switch: switch:admin> fclunquery -s The following WWNs will be used for any lun query from this switch: Node WWN: 10:00:00:60:69:e2:09:c8 Port WWN: 21:fd:00:60:69:e2:09:c8 fosConfig, iscsiCfg, iscsiPortCfg Fabric OS Command Reference 151 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 178
Service (ELS) Echo request to a pair of ports. Synopsis fcping [-h -b -q][-n frames][-l length][-i wait][-p pattern] source destination Description Use this command to 16 "pad" bytes, which are used to fill out the request frame payload sent. This is useful for diagnosing data-dependent problems - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 179
switch 12 bytes of data: received reply from 10:00:00:00:c9:29:0e:c4: 12 12 bytes time:1052 usec received reply from 10:00:00:00:c9:29:0e:c4: 12 05 [0x211e8] with 12 bytes of data: Request to the request: switch:admin> fcping 0x020800 22 75:63:85 [0x217d9] with 12 bytes of data: Request timed out - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 180
that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To clear the FCPD debug information log: switch:admin> fcplogclear See Also fcpLogDisable, fcpLogEnable, fcpLogShow 154 Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 181
that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To disable the FCPD debug information log: switch:admin> fcplogdisable See Also fcpLogClear, fcpLogEnable, fcpLogShow Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 182
that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable the FCPD debug information log: switch:admin> fcplogenable See Also fcpLogClear, fcpLogDisable, fcpLogShow 156 Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 183
Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To display the FCPD debug information log: switch:admin> fcplogshow Time Stamp Event Port file&lineno arg0 arg1 arg2 arg3 arg4 08:20:12.274 FlshOrProbe 0 1 536 2 :0 :0 :0 :0 08:20 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 184
the number of successful logins and SCSI INQUIRY commands sent over this port and a list of the attached devices. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to display, followed by a slash (/). portnumber Specify - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 185
and other failure events that have been detected on this port. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to display, followed by a slash (/). portnumber Specify the port number to display, relative to its slot for - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 186
displays the usage. By default, frame forward option is enabled. Use the --show option to display the current settings on the switch. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 187
To display the new configuration: switch:admin> fcrbcastconfig --show Broadcast configuration is disabled for: fid 2 fid 128 SEE ALSO bcastshow, portRouteShow fcrBcastConfig 2 Fabric OS Command Reference 161 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 188
for details. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -testtype - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 189
fcrChipTest 2 switch:admin> fcrchiptest --slot 7 -unit 1 -testtype 0 Running fcrchiptest Test Complete: fcrchiptest Pass 1 of 1 Duration 0 hr DMA_READ_TIMEOUT CHIP_INIT_TIMEOUT BIST_TIMEOUT BIST_FAIL fcrPathTest, miniCycle, portLoopbackTest Fabric OS Command Reference 163 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 190
example, E/F_Ports-of this switch. The backbone fabric ID must be unique across all FC Router-connected fabrics. The current Backbone Fabric ID can be displayed using the switchShow command. Examples To configure FC Router parameters: fcr:admin> fcrconfigure FC Router parameter set. to skip - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 191
FID Neighbor Switch Info (enet IP, WWN, name) 16 80 10.32.66.180 10:00:00:05:1e:34:e8:46 "b4100_7x_1" 180::10:32:66:180 27 80 10.32.69.180 10:00:00:05:1e:37:12:e0 "Sprint_180" See Also fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 192
meta-SAN, the device import or export will not be identical on the FCRs. You should therefore enter the same maximum LSAN count for all the FCR switches in the same backbone that support this feature. Verify the configured maximum limit against the LSANs configured using the fcrResourceShow command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 193
set up the LSAN fabric matrix. The FIDs entered are not required to be online when you set up the LSAN fabric matrix. In Fabric OS v6.1 and later, the LSAN fabric matrix information is automatically distributed to all switches FCR switches in the backbone that support this command. This command is - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 194
following online edge fabrics (FIDs): 1, 2, 4, 5, 7, 8, 10 (currently, 14, 19 are not available). To add the LSAN Zone Matrix data: switch:admin > fcrlsanmatrix --add 4 5 switch:admin > fcrlsanmatrix --add 4 7 switch:admin > fcrlsanmatrix --add 10 14 168 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 195
:06:2b:0d:29:31 09f002 78 10:32:16:90:29:dd:d0:07 08f002 78 10:32:16:91:24:dd:d0:05 09f001 78 4e0000 Imported 82 2a0900 Imported 82 520c00 Imported 78 4e3000 Imported 52 482200 Imported 82 2a0a00 Imported 52 48a100 Imported Fabric OS Command Reference 169 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 196
router can not join the backbone fabric. Make sure that all legacy FCR switches in the backbone support the matrix merge feature, otherwise the feature is not supported. • Use fcrlsanmatrix --fabricview -lsan | -fcr to confirm that all the switches in the backbone have the same LSAN and FCR binding - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 197
the edge fabrics. - Disable the conflicting devices. Error message (2): "There may be other FCR switches in the backbone that do not support the LSAN Binding feature or do not have the same fcrlsanmatrix settings." "Please refer to the man page for the corrective action." Corrective actions: • Check - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 198
][-unit number][-path mode][-nframes count] Description Use this command to verify the data path connecting the FC Router field to run this test. The port LEDs flicker green rapidly while the test is running. The test method is as follows: 1. Set all ports present for parallel loopback. 2. - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 199
" for details. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -unit - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 200
-f and -w operands allow searching for physical devices based on fabric ID or port World Wide Name. "No device found" is port. Physical PID The port ID of the physical device. This port ID is only relevant on the fabric specified by the "Device Exists in Fabric" column. Operands This command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 201
:84:09:0e 0100ef 3 50:05:07:65:05:84:0b:83 0100e8 Total devices displayed: 3 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference 175 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 202
Description Use this command to display or set the persistent configuration command displays the following information: importedFID The imported fabric ID of the proxy device. devWWN The port YY specifies the PortID value or the low 8-bits of the proxy device address (valid values include 01H - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 203
Examples To display the persistent proxy device configuration: switch:admin> fcrproxyconfig Imported FID 002 002 002 66:77 to use slot f101h in fabric 5: switch:admin> fcrproxyconfig -s 5 00:11:22:33: 55:66:77 from its persistent slot in fabric 5: switch:admin> fcrproxyconfig -r 5 00:11:22:33:44:55 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 204
by fabric. Search parameters -f and -w allow searching for proxy devices based on fabric ID or port WWN. "No proxy device found" is displayed if there is no proxy device information available on this FC Router. This command displays the following information: Proxy Created in Fabric The fabric in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 205
2 Examples To display the physical devices relevant to this FC Router: switch:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00 : 33 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference 179 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 206
various resources. The command output includes: LSAN switch is disabled, phantom port WWNs are not returned to the pool until the system reboots, because the phantom switch might still be accessible through other switches. Across the switch reboot, the allocation starts from the next usable WWN base - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 207
1: proxy, column 2: NR_Ports): 48 | 0 0 49 | 0 0 50 | 0 0 52 | 0 0 53 | 0 0 54 | 0 0 60 | 0 0 63 | 1 4 176 | 1 4 177 | 1 4 183 | 1 4 190 | 0 0 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference 181 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 208
the EX_Port/VEX_Port with portCfgEXPort or portCfgVEXPort. The cost can be set only on a disabled port. If no operands are specified, this command displays the current link costs for all ports on the switch. Note The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 209
To display the cost of one EX_Port: switch:admin> fcrrouterportcost 7/10 Port Cost 7/10 1000 To set the cost of an EX_Port: switch:admin> fcrrouterportcost 7/10 10000 See Also switchShow, fcrRouteShow, portCfgEXPort fcrRouterPortCost 2 Fabric OS Command Reference 183 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 210
this command to display routes through the FC Router backbone fabric to accessible destination fabrics. An FC Router backbone fabric is the fabric that contains the E_Ports of this platform and routes inter-fabric traffic between imported fabrics, creating a meta-SAN. There are FC Router ports that - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 211
. You can set the preferred domain ID when the translate domain is not active and is persistently saved. The principal switch attempts to provide make using this command should be issued on the switches to which the edge fabrics are directly attached. Note The execution of this command is subject - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 212
05 To set the preferred domain ID of the translate domain created in fabric 2 that represents remote fabric 3 to a value of 8: switch:admin> switch:admin> fcrxlateconfig -r 2 3 xlate domain deleted See Also portCfgEXPort, portCfgVEXPort, portDisable, portEnable, portShow 186 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 213
in "mixed fabrics" that include switches running firmware versions earlier than v6.0. If a v5.3/5.2 switch joins a fabric that has fabric- in mixed fabrics. However, switches that do not support the policies ignore them. Note The execution of this command is subject to Admin Domain restrictions - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 214
). All members specified in a given policy set are automatically distributed to all participating switches in the fabric that support the policy. Refer to the DESCRIPTION section for specific exceptions. In the presence of a fabric-wide FCS consistency policy, this command can only be run from the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 215
of the switch. For HBAs, only the HBA identifiers and registered port lists are displayed. No detailed HBA attributes are displayed. For registered ports, only port identifier and corresponding HBA are shown; no detailed port attributes are displayed. Note The execution of this command is subject - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 216
, along with their respective attributes. Only abbreviated FDMI information is shown for HBA and ports on remote switches. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 217
To clear the RLIR database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear the RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp, ficonShow Fabric OS Command Reference 191 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 218
modereg bitname 0 | 1 ficoncupset MIHPTO seconds Description Use this command to set FICON-CUP (Control Unit Port) parameters for a switch. All parameters can be set while the switch is online. Changes made by this command take effect immediately. A reboot is not required. Use ficonCupShow - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 219
set the ASM bit in the mode register for the switch: switch:admin> ficoncupset modereg ASM 1 Active=Saved Mode bit is set to 1 See Also To set the MIHPTO value to 60 seconds: switch:admin> ficoncupset MIHPTO 60 MIHPTO has been changed to 60 seconds ficonCupShow ficonCupSet 2 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 220
" for details Operands This command has the following operands: fmsmode Display the FICON Management Server (FMS) mode for the switch. modereg Display the FICON-CUP mode register. If no operand is specified, all mode register bit settings are displayed. If a mode register bit name is specified - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 221
To display the ASM bit in the mode register for the switch: switch:user> ficoncupshow modereg ASM ASM --1 See Also To display the MIHPTO value for the CUP: switch:user> ficoncupshow MIHPTO MIHPTO for the CUP: 60 seconds ficoncupset ficonCupShow 2 Fabric OS Command Reference 195 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 222
a list of FICON support commands with descriptions. Operands none Examples To display a list of FICON commands: switch:admin> ficonhelp ficonclear Clears contents of the specified FICON management database ficoncupset Sets FICON-CUP parameters for a switch ficoncupshow Displays FICON-CUP - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 223
the command: port for the RNID switch for RLIR is not valid. 0x50 Indicates the node ID of the channel port is not valid. Fmt Displays the record-registration format. FRU Failure Description Indicates the FRU failure type as one of the following: WWN card [unit number] The WWN card. Power - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 224
the FRU serial number. Incident Count Displays the incident count. This number increases by 1 for each incident within the individual switch. Link Incident Description Same as Link Incident Type. Link Incident Type Indicates the link incident type as one of the following: • Bit-error-rate - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 225
Part Number Displays the switch chassis part number. PID Displays the 24-bit Fibre Channel port address in 0xDDAAPP format. DD is Domain ID. AA is Area ID. PP is AL_PA ID. Plant of Manufacture Displays the manufacturer plant name or code. Port Physical port number. Port Status Displays the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 226
: switch:admin> ficonshow RNID { {Fmt Type PID Registered Port WWN Registered Node WWN flag Parm 0x18 N 502b00 50:05:07:64:01:00:15:8d 50:05:07:64:00:c1:69:ca 0x10 0x200110 Type number: 002064 Model number: 101 Manufacturer: IBM Plant of Manufacture: 02 200 Fabric OS Command Reference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 227
: 02 Sequence Number: 0000000169CA tag: 052e } } To display the local and remote LIRR database: switch:admin> ficonshow LIRR fabric {Fmt Type PID Listener Port WWN Switch Port WWN Listener Type 0x18 N 502b00 50:05:07:64:01:00:15:8d 20:2b:00:60:69:80:1e:4e Conditional 0x18 N 502e00 50:05 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 228
4e FRU part number: FRU serial number: 23000000602 FL2L0001071 {Listener Port Type Listener PID Listener Port WWN N 0x502b00 50:05:07:64:01:00:15:8d } } {FRU Failure [3]: Power Supply[4] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON 80 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 229
Power-up self tests are executed when the switch is powered on to check for the consistency of the algorithms implemented in the switch. Notes Certain services not supported on all platforms. For FIPS-compliant hardware, refer to the Fabric OS Administrator's Guide. The execution of this command is - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 230
mode/status is : Disabled/None To enable selftests: switch admin> fipscfg --enable selftests FIPS Selftests mode/status has been set to : Enabled/None To verify FIPS prerequisites: switch:admin>fipscfg --verify fips Standby firmware supports FIPS SELF tests check has passed Root account is - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 231
To enable FIPS after prerequisites have been met: switch:admin> fipscfg --enable fips FIPS mode has been set to : Enabled Please reboot the system switch:admin> fipscfg --show FIPS mode is : Enabled See Also none fipsCfg 2 Fabric OS Command Reference 205 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 232
switch firmware. Synopsis firmwarecommit Description Use this command to commit a firmware download to a CP. This command copies an updated firmware image to the secondary partition and commits both partitions of the CP to an updated version of the firmware. This must be done after each firmware - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 233
] pfile Description Use this command to download switch firmware from an FTP or SSH server or local NFS directory to the switch's nonvolatile storage area. Switch firmware can also be downloaded from an external USB device on platforms that support USB. The new firmware is downloaded in the form - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 234
you are migrating from. See the Fabric OS Administrator's Guide "Firmware Download" chapter for restrictions on changing Fabric OS versions. To correlate Brocade blade names with blade IDs, use the slotShow command. The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 235
switches in the fabric. Examples To download the firmware to an HA switch over a network: switch:admin> firmwaredownload 192.168.166.30,johndoe,/pub/dist/release.plist,12345 The following BP blades -18 v5.3.0 Virtualization This command will upgrade both CPs and all BP blade above. If you want - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 236
. To download the firmware to both CPs on a dual-CP chassis with an attached USB device. (You would execute the same command on a single CP processor with USB support. Output may vary depending on platform.) switch:admin> firmwaredownload -U v6.0.0 Checking system settings for firmwaredownload - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 237
, or is corrupted. • The FTP or SSH service is not running on host. • The platform is not supported by the firmware indicated. • The USB device may not be plugged in correctly. On standalone switches, the device must be plugged into the switch USB port. On enterprise-class platforms, the USB device - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 238
" and Appendix A, "Command Availability" for details. Operands none Examples The following example shows the status of the firmwaredownload for an SAS image to the blades in slot 2 and 7. switch:admin> firmwaredownloadstatus [1]: Thu Jul 28 00:30:49 2007 Slot 2 (SAS): Firmware is being downloaded - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 239
19 18:48:57 2007 Slot 5 (CP0, active): Firmware is being download to standby CP. This step may take up to 30 minutes. [8]: Mon Dec 19 18:49:28 2007 Slot 8 (FR4-18i): Firmware has been downloaded successfully. Blade is rebooting with the new firmware. [9]: Mon Dec 19 18:50:12 2007 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 240
has started on both active and standby CPs. [15]: Mon Dec 19 19:01:38 2007 Slot 5 (CP0, active): Firmware commit operation has completed successfully on active CP. [16]: Mon Dec 19 19:01:39 2007 Slot 5 (CP0, active): Firmwaredownload command has completed successfully. Use firmwareshow to verify the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 241
is not signed or if the signature validation fails, signed firmware download fails. Refer to the Fabric OS Administrator's Guide for complete details on upgrading or downgrading firmware. The execution of this command is subject to Admin Domain restrictions that may be in place.Refer to chapter - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 242
passwd firmwarekeyupdate -U keyfile Description Use this command to update the public key used for firmware signature validation. The firmware key can be updated over the network, or, if the switch supports this option, from an attached USB device. A default firmware key is released as part of the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 243
operand can be omitted, if the firmware key is accessible on a local directory switch:admin>Firmwarekeyupdate -U /usb/usbstorage/brocade/firmwarekey/pubkey.pem Updating the public key, please wait... Public key successfully updated. firmwareDownload, firmwareKeyShow, configure Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 244
code. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To restore the former active firmware image: switch - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 245
" and Appendix A, "Command Availability" for details. Operands none Examples To display the firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7: switch:admin> firmwareshow Slot Name Appl Primary/Secondary Versions Status 2 FA4-16 FOS v6.1.1 v6.1.1 SAS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 246
fosconfig --show Description Use this command to enable or disable a feature, or to display the current operating status of features on a switch. The following features are supported (see Notes for limitations): • FC Routing service (see fcrConfigure) • iSCSI service (see iscsiCfg) • iSNS client - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 247
online when this command was issued. Take these ports offline and try the command again. "FC Routing service is already disabled" -This means that the FC Routing service is already disabled. Disables the iSCSI service on the switch. Disables the iSNSC service on the switch. Displays the current - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 248
in Core Switch WWN Card Removal and Replacement document. Do you wish to continue [y/n]? y Backing up WWN card data, please wait about 25 seconds for further instruction. Please install the new FRU now. If this session lost for any reason, please re-enter the frureplace command and follow - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 249
Description Use this command to display the Bit positions correspond to the default areas of the ports. Bit 0 refers to default area of the switch, bit 1 refers to default area 1, and so forth. Bit map of all the trunk slave ports. Bit map of all the Fx_Ports. Bit map of all the segmented ports. Bit - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 250
2 fspfShow Examples To display FSPF protocol information: switch:admin> fspfshow version = 2 domainID = 131 switchOnline = TRUE domainValid = = 1 ddb_sem = 0x1003e6e8 fabP: event_sch = 0x0 See Also bcastShow, topologyShow, uRouteShow 224 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 251
(alarms deactivated). This operand is optional. Examples To enable alarms in Fabric Watch: switch:admin> fwalarmsfilterset FW: Alarms are already disabled switch:admin> fwalarmsfilterset 1 FW: Alarms are already enabled See Also fwAlarmsFilterShow Fabric OS Command Reference 225 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 252
"Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 253
be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To initialize all classes under Fabric Watch: switch:admin> fwclassinit fwClassInit: Fabric Watch is updating... fwClassInit: Fabric Watch has been - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 254
place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To reload the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See Also configDownload - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 255
areas are provided in Table 12. The following restrictions apply: 1. The Port class does not support VE _Ports and VEX_Ports, except for State Changes. 2. The E_Port class has the same port limitations as the port class except under the following condition: On a Brocade 48000 with a FR4-18i blade - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 256
TABLE 12 Class fwConfigure Fabric Watch classes and areas Area Fabric E_Port E_Port downs Fabric reconfigure Domain ID changes Segmentation changes Zone changes FabricQL Fabric logins SFP state changes Link loss (E-port) Sync loss (E-port) Signal loss (E-port) Protocol error (E-port) Invalid - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 257
Availability" for details. Not all platforms support fans or power supplies. If you attempt to configure values for these items the following displays: "ERROR: No threshold available. This command has the following optional operands: --enable --port portNumber Enables all thresholds associated with - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 258
F/FL Port (Optical) class 7 : Alpa performance Monitor class 8 : EE performance Monitor class 9 : Filter performance Monitor class 10 : Security class 11 : Resource class 12 : Quit Select a class => : (1..12) [1] 1 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an area - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 259
fwConfigure 2 3 : Power Supply 4 : return to previous page Select an area => : (1..4) [4] 1 Index ThresholdName Status CurVal LastEvent return to previous page Select choice => : (1..5) [5] 5 See Also fwClassInit, fwConfigReload, fwShow Fabric OS Command Reference 233 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 260
Displays or modifies FRU state alert configuration. Synopsis fwfrucfg [--show] Description Use this command to configure field-replaceable unit (FRU) states and actions. Based on these configuration settings, Fabric Watch generates action when a FRU state changes. To configure email alerts, use - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 261
level to custom Set boundary & alarm level to default Show thresholds monitored or port persistence time Show sensor readings Set switch status policy parameters Show switch status policy parameters Show overall switch status Show switch temp readings See Also none Fabric OS Command Reference 235 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 262
may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To configure email settings: switch:admin> fwmailcfg 1 : Show Mail Configuration Information 2 : Disable Email Alert 3 : Enable Email Alert - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 263
class 9 : Filter Performance Monitor class 10 : Security class 12 : FRU Class 13 : Quit Select an item => : (0..13) [11] 1 Mail To: [NONE] [email protected] Email Alert configuration succeeded! See Also dnsConfig, fwConfigure, ipAddrSet, ipAddrShow Fabric OS Command Reference 237 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 264
not healthy, the contributing factors also are listed. Notes This command requires a Fabric Watch license. Port errors are not supported for virtual ports and SFP errors are not applicable for virtual ports. The execution of this command is subject to Admin Domain restrictions that may be in place - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 265
entries are: h Report based on all healthy ports m Report based on all marginal ports f Report based on all faulty ports o Report based on all offline ports If no option is specified, all ports are displayed. Examples To retrieve a port detailed report for a switch configured with an IPv6 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 266
See Also To retrieve a port detailed report: switch:user> fwportdetailshow --s h Port Detail Report Switch Name: switch IP address: 192.168.163.237 Port Exception report [by Healthy] Report time: 05/21/2007 11:22:58 PM --------Port-Errors SFP-Errors---- Port# Type State Dur(H:M) LFA - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 267
port. Notes This command requires a Fabric Watch license. Operands none Examples To generate a SAM report on an eighty-port switch: switch:user> fwsamshow Total Total Down Total Port 0 0 100 12 U 0 0 0 100 13 U 0 0 0 100 14 U 0 0 0 100 15 U 0 0 0 100 16 F 100 0 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 268
0 0 0 100 46 U 0 0 0 100 47 U 0 0 0 100 48 U 0 0 0 100 49 U 0 0 0 100 50 U 0 0 0 0 0 100 62 U 0 0 0 100 63 U 0 0 0 100 64 U 0 0 0 100 65 U 0 0 0 100 66 U 0 0 See Also portShow, switchShow 242 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 269
with this option. Port persistence time is the time period in which a port must be persistently in a state before being recognized as such. Examples To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See Also fwShow Fabric OS Command Reference 243 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 270
unique environment. Refer to fwConfigure help for information on how to customize Fabric Watch settings. The fwSetToCustom command allows you to switch from default to custom settings. The command assumes that a set of user-defined thresholds have been configured prior to executing fwSetToCustom - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 271
Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an area => : (1..4) [4] 1 Index set at : Custom Unit Time base Low High BufSize Default C 0 60 10 Custom C 0 60 10 Threshold alarm level is set at : Custom Errlog-1, SnmpTrap-2, RapiTrap-8 EmailAlert-16 Valid alarm matrix - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 272
2 fwSetToCustom 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18] See Also fwSetToDefault, fwConfigure, fwHelp, fwShow 246 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 273
allows you to switch from custom to default settings. If no user-defined settings exist, this command reapplies the default values. Use the advanced configuration option provided with the fwConfigure command to view and modify custom and default values for specified classes and areas in Fabric Watch - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 274
Power Supply 4 : return to previous page Select an area 6 envTemp006 enabled 32 C inBetween Thu set at : Custom Unit Time base Low High BufSize Default C 0 60 10 Custom C 0 60 10 Threshold alarm level is set at : Custom Errlog-1, SnmpTrap-2, RapiTrap-8 EmailAlert-16 Valid alarm matrix - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 275
10 : cancel threshold boundary changes Select choice => : (1..18) [18] See Also fwSetToCustom, fwConfigure, fwHelp, fwShow fwSetToDefault 2 Fabric OS Command Reference 249 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 276
Guide. In Access Gateway mode, only the following class thresholds are supported. F/FL Port (Copper) class threshold is supported only on Embedded platforms. TABLE 14 Access Gateway mode classes Class Environmental SFP Port Fabric F/FL_Port (Optical) F/FL_Port (Copper) Resource Notes This command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 277
Select an item => : (1..12) [12] 1 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an area => : (1..4) [4] 2 Name Label Last value envFan001 Env Fan 1 2576 RPM envFan002 Env Fan 2 2518 RPM envFan003 Env Fan 3 2481 RPM switch:user> fwshow 1 : Show - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 278
last at 16:30:23 on 12/09/2011 Callbacks: No callbacks are registered. To show port persistence time: switch:admin> fwshow --port --persistence FW: current port persistence time = 18s To display ports that have all thresholds disabled: switch:user> fwShow --disable --port Port Threshold Status - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 279
the UNIX Korn shell history facility. The h command displays the 20 most recent commands typed into the shell; the oldest commands are replaced as new ones are entered. Operands none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 portdisable 2 4 portenable - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 280
the High Availability feature. Synopsis hadisable Description Use this command to disable the High Availability (HA) feature on a switch. If the HA feature is already disabled, this command does nothing. Note The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 281
Description Use this command to display information about the status of the High Availability (HA) feature on a switch. This command displays the is running, but the background health diagnostic has discovered a problem with the blade. The logs should be checked to determine the appropriate repair - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 282
Enabled: No Local IPv6 Addresses: sw 0 static fec0:60:69bc:64:260:69ff:fee4:3a/64 cp 0 static fec0:60:69bc:64:205:1eff:fe25:9c1/64 cp 1 static fec0:60:69bc:64:205:1eff:fe02:a197/64 FSSME registered: TRUE [output truncated] See Also haFailover, haShow 256 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 283
the High Availability feature. Synopsis haenable Description Use this command to enable the High Availability (HA) feature on a switch. If the HA feature is already enabled, this command does nothing. Note The execution of this command is subject to Admin Domain Restrictions that may be in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 284
(HA) synchronization is enabled and the CPs are in sync, the port traffic light does not flash during the failover, even while traffic is continuing to flow. This command is supported only on dual-CP systems. The execution of this command is subject to Admin Domain restrictions that may be in place - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 285
a problem with the blade. The supported on non-bladed systems. Operands none Examples To display CP status, first on a healthy standby CP and then on a faulty standby CP: switch:admin> hashow Local CP (Slot 6, CP1): Active, Cold Recovered Remote CP (Slot 5, CP0): Non-Redundant Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 286
2 haShow See Also switch:admin> hashow Local CP (Slot 6, CP1): Active, Warm Recovered Remote CP (Slot 5, CP0): Standby, Failed Backplane PCI fail, severity: CRITICAL HA enabled, Heartbeat Up, HA State not in sync haDisable, haEnable, haFailover 260 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 287
may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 288
synchronization may cause failover to be disruptive. The execution of this command is subject to Admin Domain restrictions that may be in place and Appendix A, "Command Availability" for details. Operands none Examples To disable the HA state synchronizing process: switch:admin> hasyncstop See - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 289
name as an operand. Operands This command has the following operand: command Specify the command name, with or without quotation marks. This operand is optional. Examples To display help information for the help command: switch:admin> help help See Also diagHelp, fwHelp, licenseHelp, perfHelp - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 290
Factory Part Number xx-yyyyyyy-zz or Not available Factory Serial Number xxxxxxxxxxxx or Not available The size of the history log depends on the HW platform. The Brocade 48000 director supports 100 history log entries. The Brocade DCX supports a maximum log size of 50 entries. Since the WWNs are - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 291
command to display or set the mode of the history buffer, which records the insertion and removal of FRUs on a switch or chassis. This command supports depends on the HW platform: The Brocade 48000 Director supports 100 history log entries. The Brocade DCX backbone supports a maximum log size of 50 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 292
FRUs support 28 history log entries. Operands none Examples To display the history log of FRUs and removal events on a standalone switch: switch:admin> historyshow FAN Unit 3 Removed at Tue Aug 14 10:05:37 1970 Factory Part Number: 20-123456-12 Factory Serial Number: 1013456800 POWER SUPPLY - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 293
Tue Aug 14 13:53:40 2001 Factory Part Number: 60-0001532-03 Factory Serial Number: 1013456800 CP BLADE Slot 6 Inserted at Tue Aug 14 13:59:50 2001 Factory Part Number: 60-0001604-02 Factory Serial Number: FP00X600128 POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 294
to display the version of the Java plug-in supported by Web Tools. This command also displays the URL from which the plug-in can be downloaded. Operands none Examples To display the Java plug-in version: switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,5,0,6 javaplugin - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 295
warning messages 002 being created 004 getting shut down 010 set if ptrace (0) has been called 020 tracing system calls 040 forked but did not exec 100 used super-user privileges 200 dumped core 400 killed by a signal Process state codes: D uninterruptible sleep (usually IO) R runable (on run queue - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 296
ID for the process to display. Examples To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also diagHelp, routeHelp 270 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 297
or disable an inter-chassis link (ICL) on a Brocade DCX. The command enables or disables the ICL by enabling or disabling the ports associated with the link. This command is supported only on the Brocade DCX backbone. Notes The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 298
might be set to operate in different modes. Note The execution of this command is subject command through the serial console port, follow this scenario for the ifModeSet command: switch:admin> ifmodeset eth0 Exercise care when using this command. Forcing the link to an operating mode not supported - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 299
To force the link for the eth0 interface from auto-negotiation to 10 Mbps half-duplex operation, when entering this command through the serial console port: switch:admin> ifmodeset eth0 Auto-negotiate (yes, y, no, n): [yes] n Force 100 Mbps / Full Duplex (yes, y, no, n): [no] n Force 100 Mbps / Half - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 300
Use this command to display the link operating mode and MAC address for a network interface. Operands This command has the . Examples To display the link operating mode for the "eth0" Ethernet interface: switch:admin> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok MAC Address: 00: - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 301
• The neighbor data structure. This data structure is allocated when a switch port becomes an E_Port. The neighbor data structure contains all the information relating to the switch that is connected to an adjacent switch. This command displays the content of both data structures, if they have been - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 302
to the neighbor switch through this port. rXmitTo Retransmission timeout value, in milliseconds. It is used to transmit topology information to the neighbor switch. If no acknowledgement is received within this value, the frame is retransmitted. nCmdAcc Total number of commands accepted from the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 303
of attempted transmissions of LSAs to the neighbor switch. Number of LSAs transmitted to the neighbor switch. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to display, followed by a slash (/). portnumber Specify the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 304
rXmitTo nCmdAcc nInvCmd nHloIn nInvHlo nLsuIn nLsaIn attHloOut nHloOut attLsuOut nLsuOut attLsaOut nLsaOut = 0x1008c848 = 80000 = 2000 = 5000 = 7 = 0 = 2 = 0 = 2 = 3 = 2 = 2 = 3 = 3 = 2 = 2 See Also nbrStateShow, portShow, switchShow 278 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 305
Fabric Mode (3) are disabled except display commands and two set commands, cfgDisable and cfgClear, which can only be called when the switch is offline. When changing From Brocade Native to McDATA Fabric or McDATA Open Fabric Mode: • McDATA Fabric mode only supports a user domain ID range of 1-31 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 306
the OUI portion of the switch WWN is no longer replaced with a McDATA OUI. The Brocade OUI is used. However, command. For information on supported hardware platforms and procedures regarding OS v5.2.1_NI to v6.0.0 migration, refer to the Fabric OS Administrator's Guide. The execution of this command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 307
effect. Do you want to continue? (yes, y, no, n): [no]y The configuration is being saved - a system reboot will cause the change to take effect. Please disable switch before changing the interop mode. cfgMcdtMode, cfgSaveActiveToDefined Fabric OS Command Reference 281 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 308
not configured or reset, the system uses its own internal algorithm to calculate the IOD delay. The switch must be disabled before IOD delay can be set. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 309
in the establishment of a new path after a topology change does not exceed the specified value. The switch must be disabled before IOD delay can be set. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 310
Specifies the domain ID for which to display the IOD delay setting. If this operand is omitted, the command displays the IOD delay settings for all domains in the fabric. Examples To Display the IOD delay setting for domain 5: switch:user> ioddelayshow 5 omain - Iod Delay 5 - 20 To display IOD - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 311
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To turn off the IOD option: switch:admin> iodreset switch:admin> iodshow IOD is not set See Also iodSet, iodShow, iodDelaySet, iodDelayReset, iodDelayShow Fabric - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 312
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To turn on the IOD option: switch:admin> iodset switch:admin> iodshow IOD is set See Also iodReset, iodShow, iodDelaySet, iodDelayReset, iodDelayShow 286 Fabric - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 313
the in-order delivery (IOD) option setting. Synopsis iodshow Description Use this command to display whether the IOD option is enabled or disabled. The default setting for IOD is disabled. Operands none Examples To display the current setting of the IOD option: switch:admin> iodshow IOD is not - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 314
add x.x.x.x/n | --delete] ipaddrset [-slot number] -gate [--add x.x.x.x | --delete] Use this command to set the IP addresses on a switch, a CP, a BP, or a standalone AP. The command supports an interactive mode, which supports only IPv4 addresses, and an alternate interface for managing IP address - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 315
-cp number | -sw number On an enterprise-class system, specify CP or logical switch. Valid values for number are 0 or 1. On platforms with blade processors, the following additional command line options are supported with the --add or --delete options: -eth0 |-eth1 Specify local IPv4 address of - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 316
on a Brocade FC4-16E in a chassis (prefix required): switch:admin> ipaddrset -slot 1 -eth0 --add 10.12.34.123/24 To configure a local IPv4 Ethernet address on an AP7600 with a hidden BP: switch:admin>ipaddrset -eth0 --add 10.12.34.123/24 See Also ipAddrShow 290 Fabric OS Command Reference 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 317
switches, the command displays the Ethernet IP address, Ethernet subnetmask, Fibre Channel IP address, and Fibre Channel subnetmask. For CPs, the command displays the Ethernet IP address, Ethernet subnetmask, host name, and gateway IP address. For chassis based systems with intelligent blades the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 318
port -proto protocol -act permit | deny ipfilter --delrule policyname -rule rule number ipfilter --transabort Description Use this command to manage IP filter policies. The ipfilter command and command options are non-interactive, except when prompting for a confirmation. The IP filter policy sets - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 319
displays without pagination. Use command | more to display the output with page breaks.If a temporary buffer exists for an IP filter policy, the --show operand displays the content in the temporary buffer, with the persistent state set to modified defined or modified active. --save [policyname - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 320
supported with the --addrule option: -sip Specifies the source IP address. For filters of type IPv4, the address must be a 32-bit address in dot notation, or a CIDR-style IPv4 prefix. For filters of type IPv6, the address must be a 12- bit port, and protocol, and to permit the rule: switch: - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 321
fe80:d4a tcp Dest Port Action 23 permit To activate the IP Filter policy "ex1": switch:admin> ipfilter -- 12 any udp 600 - 1023 permit Name: ex1, Type: ipv6, State: active Rule Source IP 1 fec0:60:69bc:60:260:69ff:fe80:d4a Protocol Dest Port Action tcp 23 permit Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 322
111 permit 10 any udp 123 permit 11 any tcp 600 - 1023 permit 12 any udp 600 - 1023 permit Name: ex2, Type: ipv4, State: defined Rule Source IP Protocol Dest Port Action 1 10.32.69.99 tcp 23 permit See Also policy, distribute 296 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 323
ddset [-n ddset_name] [-h] iscsicfg --show ddset [-n ddset_name] [-v] [-h] iscsicfg --show fabric [-h] iscsicfg --clear initiator [-h] iscsicfg --show initiator [-i initiator_name] [-h] iscsicfg --abort transaction -x transaction_id [-h] Fabric OS Command Reference 53-1000599-02 iscsiCfg 2 297 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 324
[-f] [-h] Use this command to configure all iSCSI entities (such as authentication (CHAP), discovery domains (DD), discovery domain sets (DDSet), iSCSI virtual changes to all iSCSI-enabled switches and blades in the fabric. Changes do not take effect until a --commit all command is issued. Make all - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 325
, based on port_wwn specifies the port WWN of the supported. Multiple entities may be specified as a comma-separated list. The IQN may be a maximum of 64 characters. --add dd -d dd_name -m member_list [-h] Adds a new member to an existing DD. DD member lists also are acceptable. Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 326
Adds a new DD to an existing DD set. --delete ddset -n ddset_name [-d dd_list] [-h] Deletes the DD set with ddset_name. If dd_list is specified, only switch is aware of. If an initiator has attempted discovery or logon to a target, it is displayed here. If initiator_name is specified, this command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 327
.2005-10.com.brocade.tgt1 Offline/Defined Name: State/Status: iqn.2222-23.com.brocade:21:00:00:20:37:df:83:fc Online/Committed To delete a target entry: switch:admin> iscsicfg --delete tgt -t iqn.2005-10.com.brocade.tgt1 The operation completed successfully. Fabric OS Command Reference 301 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 328
Index FC WWN iSCSI Name Status [Output truncated] To add a LUN map: switch:admin> iscsicfg --add lun -t iqn.2005-10.com.brocade.tgt1 -w 22:00:00:04:cf:20:5d:33 -l 0:0 The operation completed successfully. switch:admin> iscsicfg --add lun -t iqn.2005-12.com.brocade.tgt2 -w 22:00:00:04:cf:75:5b:9a - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 329
create a DD set entry: switch:admin> iscsicfg switches that are capable of propagating iSCSI data base): switch:admin> iscsicfg --show fabric Switch ID Switch WWN Switch State iSNSC * 1 10:00:00:60:69:e4:20:1e -- Disabled Aggregated iSCSI database state for fabric: In Sync Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 330
172.16.14.101 switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 Initiator details are: Name IP Address iqn.1991-05.com.brocade:isi154116.englab.brocade.com 172.16.14.101 No. of targets currently accessible to the specified initiator are: 4 iqn.2222-12.com.brocade - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 331
the network processor and iFlipper FPGA. Note This command is supported only on the Brocade FR4-16IP blade. On all other platforms, this command displays the message: "Command not applicable to this platform. SKIPPED!" The execution of this command is subject to Admin Domain restrictions that may - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 332
Examples To display the list of iSCSI support commands: switch:admin> iscsihelp fclunquery fosconfig iscsicfg iscsiportcfg iscsisessioncfg iscsiswcfg portcfg portshow switchshow Display a list of LUNs of FC target(s). Enable/disable FabOS services Manage/display all iscsi configuration including - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 333
, and hardware connections in the iSCSI complex. You can set the data path mode with the -path option. Note This command is supported only on the Brocade FR4-16IP blade. On all other platforms, this command displays the message: "Command not applicable to this platform. SKIPPED!" The execution of - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 334
Use this command to display or modify the iSCSI port parameters. The default iSCSI port settings are as follows: TABLE 16 Default iSCSI port settings Setting Default Error recovery level Connections per session Connections per session Header digest support Immediate data support First burst - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 335
number. This parameter only supports FC4-16IP blades in Brocade 48000 directors. Specifies the port number of a GbE port to be configured in the specified slot. Use -h on any option to display the help text for it. Examples To modify the port parameters: switch:admin> iscsiportcfg --modify 7/ge2 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 336
2 iscsiPortCfg See Also iSCSI Abort Task Set: iSCSI Clear ACA: iSCSI Clear Task Set: iSCSI LUN Reset: iSCSI Target Reset: iSCSI 2576 17 1352 1 Normal iqn.1991-05.com.microsoft:win-iscsi.lab iqn.2002-12.com.tgt:21:00:00:04:cf:5d:cf:0e 0x400001370000 310 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 337
A, "Command Availability" for details. Operands This command has 12.com.brocade:2f:df:00:06:2b:0d:10:b9 Session type Init. Session ID Tgt. Session ID Initiator IP Num. Conns . Normal 0x400001370000 1025 30.50.1.115 1 TCP Connection Details Index TCP Port Leading Connection Switch Port - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 338
Task Set: 0 iSCSI LUN Reset: 0 iSCSI Target Reset: 0 iSCSI Task Reassign: 0 Non FCP in PDU: 0 Non FCP in Octet: 0 Non FCP out PDU: 0 Non FCP out Octet: 0 See Also fosConfig, iscsiCfg, iscsiPortCfg 256KB 64KB 16 60s 0s 2 Off Peer Value 64KB On On On 312 Fabric OS Command Reference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 339
Disabled To display a target name prefix: switch:admin> iscsiswcfg --showgw Target name is: iqn.2002-12.com.brocade To change a target name prefix: switch:admin> iscsiswcfg --modifygw -t iqn.2002-10.com.brocade The operation completed successfully. Fabric OS Command Reference 313 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 340
2 iscsiSwCfg See Also fosConfig, iscsiCfg, iscsiPortCfg 314 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 341
neptune sp: 8.000G bw: 32.000G TRUNK QOS 2: 8-> 3 10:00:00:05:1e:41:8a:d5 30 thor sp: 4.000G bw: 16.000G TRUNK QOS 3: 19-> 10 10:00:00:05:1e:41:43:ac 50 tomahawk sp: 8.000G bw: 64.000G TRUNK See Also switchShow, trunkShow Fabric OS Command Reference 315 53-1000599 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 342
of a GbE port in an iSCSI blade. This parameter only supports Brocade FC4-16IP blades in Brocade 48000 directors. -s server_ip Specifies the IP address in dotted-decimal form. Examples To set the IP address of an external iSNS server with an attached GbE port: switch:admin> isnsccfg --set 7/ge0 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 343
2 See Also To register the iSNS objects: switch:admin> isnsccfg --reregister Initiated re-register of iSNS objects with iSNS server To clear the IP address of iSNS server: switch:admin> isnsccfg --clear Cleared iSNS server configuration. none Fabric OS Command Reference 317 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 344
and "1/0 - 1/15" are equivalent. • If no slot number is specified, user port lists are specified by area number. For instance, "0, 16, 32" and "1/0, 2/0, 3/0" specify the same ports on a 16-port/blade system. On that same system, "1/0, 16, 32" is not a valid list: even though it is legal syntax, the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 345
Switch Blade Blade Blade Chassis n.a. Blade ports, internal and external ports User ports, ports with external connections Quadrants, group of (normally four) ports Chips, ASICs within a blade Mini-switches Slots Anything Operands Examples See Also none none portLoopbackTest Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 346
2 killTelnet killTelnet Terminates an open Telnet session. Synopsis killtelnet Description Use this command to terminate an open Telnet session. The command lists all current Telnet and serial port login sessions and information such as session number, login name, idle time, IP address of the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 347
-defined group which allows a user belonging to that group to login to the switch with the permissions associated with the mapped switch role. This command supports one-to-one role mapping only. For example, you might map the "SAN administrator" role on the AD server to the "admin" role on the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 348
of existing mappings between LDAP roles and their corresponding switch role. Displays command usage. Examples To display current LDAP and switch role map: switch:admin> ldapcfg --show LDAP Role | Switch Role ldapadmin | admin ldapuser | user SANfabadmin | fabricadmin SANzoneadmin - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 349
. For a trunking license to become effective, the trunk ports need to be refreshed using the commands portDisable and portEnable or the switch must be refreshed using the commands switchDisable and switchEnable. Operands This command has the following operand: "license" Specify a license key - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 350
used to administer license keys. Operands none Examples To display license commands: switch:admin> licensehelp licenseadd licensehelp licenseidshow licenseremove licenseshow Adds license keys to switch Print license help info Displays the system license ID Removes a license key from this - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 351
the license ID of the system. Some features of the switch and the fabric are optional, licensed products. Without a license installed for such products, the services provided by these features are not available. This command displays the system license ID used for both generating and validating - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 352
where there are more online ports than the purchased POD licenses can support. Note The execution of this command is subject to Admin Domain port from a Dynamic POD license assignment: switch:admin> licensePort --release 5 To reserve a Dynamic POD license assignment for a port: switch: - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 353
licenses: 10 ports are assigned to the base switch license 5 ports are assigned to the first POD license Ports assigned to the base switch license: 0, 1, 2, 3, 4, 5, 6, 7, 15, 16 Ports assigned to the first POD license: 8, 9, 17, 18, 19 Ports assigned to the second POD license: 10, 11, 12, 13, 14 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 354
2 licenseRemove licenseRemove Removes the license key from the system. Synopsis licenseremove "license" Description Use this command to remove an existing license key from a switch. The existing license key must be entered exactly as shown by licenseShow, including case. When the key has been - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 355
temporary licenses When no licenses are installed, the command displays "No license installed on this switch." Operands none Examples To display the license keys on a switch with permanent licenses installed: switch:admin> licenseshow S9bddb9SQbTAceeC: Fabric license eezeRRySff0fSe: Remote - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 356
ISL 500 When executed without operands, the command displays the current cost of each port on the switch, including non-ISLs. An E_PORT suffix command displays the cost for all ports. The following operands are optional: slotnumber For bladed systems only, specify the slot number for which to set - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 357
2 2 500 (STATIC) 2 3 200 (STATIC) 2 4 1000 2 5 1000 2 6 1000 2 7 1000 2 8 1000 2 9 1000 2 10 1000 2 11 (E_PORT) 2000 (STATIC) 2 12 1000 2 13 1000 2 14 1000 2 15 1000 Type to continue, Q to stop: To set the ISL cost on a port: switch:admin> linkcost - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 358
through a Telnet or rlogin session, that session is left open. This command allows you to access commands that you cannot access at your current user level. Operands none Examples To log in as admin from the login user: switch:user> login login: admin Password:xxxxxx See Also logout 332 Fabric - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 359
Remote login connections are closed and the local serial connections return to the login prompt. The exit command is accepted as a synonym for logout, as is Ctrl-D at the beginning of a line. Operands none Examples To log out from an rlogin session: switch:admin> logout See Also login Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 360
for LSAN zones based on fabric ID, port WWN. The WWN format is xx:xx:xx:xx:xx:xx:xx:xx. -z zonename Displays LSAN zones with the specified zone name. The database for zones is displayed per switch, which can differ from the database stored on the other FCR switches. 334 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 361
lsanZoneShow 2 Examples See Also To display the LSAN zones: switch:admin> lsanzoneshow Fabric ID: 4 Zone Name: lsan_fcr10_0 50:05:07:65 :84:0b:83 50:05:07:65:05:84:09:0e switch# fcrFabricShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow Fabric OS Command Reference 335 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 362
lsDbShow lsDbShow Displays the Fabric Shortest Path First (FSPF) link state database. Synopsis lsdbshow [domain] Description Use this command to display an FSPF link state database record for switches in the fabric, or one domain within it. There are two types of database entries: 1. The link - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 363
It is the domain number of the switch on the other side of the link. Port number on the local switch. Port number of the port on the other side of the link. Cost of this link. The default cost for a 1 Gbps link is 1,000. Always 0. Always 1. Operands This command has the following operand: domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 364
port = 32, rem port = LinkId = 2, out port = 33, rem port = LinkId = 2, out port = 34, rem port = LinkId = 2, out port = 35, rem port = LinkId = 2, out port = 44, rem port = LinkId = 2, out port = 45, rem port = LinkId = 2, out port = 46, rem port = LinkId = 2, out port = 47, rem port = 48 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 365
total used Mem: 129740800 112562176 Swap: 0 0 switch:admin> memshow -m total used Mem: 123 107 Swap: 0 0 free 17178624 0 free 16 0 shared 0 buffers cached 139264 30396416 shared 0 buffers 0 cached 28 See Also supportSave Fabric OS Command Reference 339 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 366
[--slot slotnumber][-nmegs count][-lb_mode mode][-spd_mode mode][-splb_mode 0 | 1] [-ports itemlist] Description Use this command to verify the intended functional operation of an ASIC pair (miniswitch) at the maximum or selected speed by setting up the routing hardware so that frames received by - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 367
with the results of portLoopbackTest can determine which components of the switch are faulty. Notes The Brocade DCX backbone cannot negotiate to 1 Gbps speed. Setting spd_mode to 1 is invalid for this platform. The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 368
) are used. Refer to itemList for further details. If all ports in the ASIC pair are not specified, only paths between selected ports are tested. ASIC-pair 0: -ports 0-15 ASIC-pair 1: -ports 16-31 ASIC-pair 2: -ports 32-47 ASIC-pair 3: -ports 48-63 342 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 369
hr, 1 min & 4 sec (0:1:4:409). passed. To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One moment FDET_PERR FINISH_MSG_ERR Fabric OS Command Reference 343 53-1000599- - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 370
PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. itemList, portLoopbackTest 344 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 371
fabric. An asterisk displays next to the name of the local switch. Notes Reliable commit service (RCS) is a fabric-wide capability and is supported only if all the switches in the fabric support the service. The execution of this command is subject to Admin Domain restrictions that may be in place - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 372
Appendix A, "Command Availability" for details. This command is supported only in AD0 and AD255 contexts. Operands none Examples To display the MS ACL: switch:admin> msconfigure 0 Done 1 Display the access list 2 Add member based on its Port/Node WWN 3 Delete member based on its Port/Node - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 373
list 2 Add member based on its Port/Node WWN 3 Delete member based on its Port/Node WWN select : (0..3) [1] 0 done ... msCapabilityShow, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig, secPolicyShow Fabric OS Command Reference 347 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 374
platform database. This command displays the name of each platform object with the platform type (GATEWAY, HOST_BUS_ADAPTER, and so forth), associated management addresses, and associated node names. Operands none Examples To display the MS platform database for a fabric: switch:admin> msplatshow - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 375
control block. Synopsis msplatshowdbcb Description Use this command to display the control block fields associated with the platform database. Operands none Examples To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry Count - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 376
"Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. This command is supported only in AD0 and AD255 contexts. Operands none Examples To clear the MS platform database: switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 377
is persistent across power cycles and reboots. Notes By default, the MS platform service is disabled. Before issuing this command, run msCapabilityShow to verify that all switches in the fabric support the MS platform service; if one switch does not support the service, the command fails. When FCS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 378
Restrictions" and Appendix A, "Command Availability" for details. This command is supported only in AD0 and AD255 contexts. Operands none Examples To deactivate the MS platform service on all switches in the fabric: switch:admin> msplmgmtdeactivate MS Platform Service is currently enabled. This - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 379
The change is persistent across power cycles and reboots. Notes Topology Discovery Management requires the attached devices (including attached switches) to support request node identification data (RNID) extended link service (ELS). When FCS policy is enabled, and this command is issued with the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 380
The change is persistent across power cycles and reboots. Notes Topology Discovery Management requires the attached devices (including attached switches) to support request node identification data (RNID) extended link service (ELS). When FCS policy is enabled, and this command is issued with the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 381
Server (MS) topology discovery service. Synopsis mstdreadconfig Description Use this command to check whether or not the management server topology discovery service is enabled. Operands none Examples To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 382
. Synopsis myid Description Use this command to display the status of the system and the login session details. This includes IPv4 or IPv6 addresses associated with the login session. The login session gives details of the following: • CP/switch (or console/serial port) used to log in. • The - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 383
states are displayed. Examples To display information about switches directly connected to the local switch: switch:user> nbrstateshow 2/0 Local Domain ID: 1 Local Port Domain Remote Port State 16 2 48 NB_ST_FULL See Also interfaceShow Fabric OS Command Reference 357 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 384
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to display, followed by a slash (/). portnumber Specify the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 385
the changes: switch:admin> interfaceshow 1/0 idbP = 0x10050a38 Interface 0 data structure: nghbP ifNo masterPort defaultCost cost = 0x1004ce68 = 0 = 0 (self) = 500 = 500 (output truncated) See Also interfaceShow, portShow, switchShow nbrStatsClear 2 Fabric OS Command Reference 359 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 386
the alias "a320": switch:user> nodefind a320 Local Port Index: 20 Share Area: No Device Shared in Other AD: No Aliases: a320 NL 0314d4; 3;22:00:00:04:cf:9f:26:7e;20:00:00:04:cf:9f:26:7e; 0 FC4s: FCP [SEAGATE ST336605FC 0003] Fabric Port Name: 20:14:00:60:69:80:04:79 360 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 387
: Physical Target Port Index: 14 Share Area: No Device Shared in Other AD: No Aliases: No match: To display device information for a string for which there is no match: switch:user> nodefind abcd No device found. See Also aliShow, nsAllShow, nscamShow, nsShow Fabric OS Command Reference 361 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 388
message is displayed if there is no information in this switch: There is no entry in the Local Name Server The command nsAllShow displays information from all switches. The display resulting from this command is identical to the command nsShow, with the exception of an additional line listing the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 389
switch:admin> nsaliasshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Fabric Port Name: 20:04:00:60:69:01:44:22 Permanent Port Name: 21:00:00:fa:ce:00:21:e1 Aliases: MyAlias1 MyAlias2 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 390
70; 0 FC4s: FCP [STOREX RS2999FCPH3 JB09] Fabric Port Name: 20:04:00:60:69:01:44:22 Permanent Port Name: 21:00:00:ad:bc:04:6f:70 Device type: Physical Target Aliases: The Local Name Server has 6 entries } See Also nsAllShow, nsShow, switchShow 364 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 391
021300 0214e2 0214e4 0214e8 0214ef 12 Nx_Ports in the Fabric } switch:admin> nsAllShow 8 { 0118e2 0118e4 0118e8 0118ef 0214e2 0214e4 0214e8 0214ef 8 FCP Ports } switch:admin> nsAllShow 5 { 011200 021200 2 FC-IP Ports } See Also nsShow, switchShow Fabric OS Command Reference 365 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 392
U for unknown, N for N_Port, NL for NL_Port. Pid The 24-bit Fibre Channel address. COS A list of classes of service supported by the device. PortName The device's port World Wide Name (WWN). NodeName The device's node WWN. Permanent Port Name Physical N_Port or NL_Port WWN. There might be - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 393
0001" Fabric Port Name: 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Device type: Physical Initiator Switch entry for 4 state rev owner known v320 0xfffc01 Device list: count 0 No entry is found! See Also nsAllShow, nsShow, switchShow Fabric OS Command Reference 367 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 394
to display NS information for all switches in the fabric. Each line of output displays the following information: Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. PortName Device port World Wide Name (WWN - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 395
Examples To display local NS information: switch:admin> nsshow { Type Pid COS Port Name: 20:0e:00:05:1e:34:00:70 Permanent Port Name: 21:00:00:e0:8b:12:8a:be Port Index: 14 Share Area: No Device Shared in Other AD: No Redirect: No The Local Name Server has 2 entries } Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 396
Name: 20:0e:00:05:1e:34:00:70 Permanent Port Name: 21:00:00:e0:8b:12:8a:be Device type: Physical Initiator Port Index: 14 Share Area: No Device Shared in Other AD: No Redirect: No The Local Name Server has 2 entries } nsAllShow, switchShow 370 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 397
service supported by the device. PortName The device's port World Wide Name (WWN). NodeName The device's node WWN. Permanent Port Name The physical N_Port or NL_Port WWN. DeviceType The device's type. Port Index The index of the port to which the device is attached. Shared Area Whether - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 398
online zoned device data: switch:admin> nszonemember -a Port: 4 Pid: 0xb00400 Port: 12 Pid: 0xb00c01 Aliases: dl360_130159a Zoned Members: 2 devices Pid: 0xb00c01 Aliases: dl360_130159a Pid: 0xbd1bef Aliases: nstor4b_8 Port: 13 Pid: 0xb00d00 Aliases: ix360_131_196p5 372 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 399
ix360_131_196p5 Pid: 0xe07d00 Aliases: hds9200_6p4 hds9200_6p4 Port: 14 Pid: 0xb00e00 Aliases: dl360_130251a To display all the unzoned devices in the fabric: switch:admin> nszonemember -u Pid: 0xb01ea9; Aliases: trimm32b_1 cfgShow, nscamShow, nsShow Fabric OS Command Reference 373 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 400
switches in the fabric, the switches must be configured to accept the password database with the fddCfg command. The password database is distributed manually with the distribute command the password set by the administrator is recorded in the user's password history. The passwd command behaves as - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 401
to terminate. Examples To change the password for the admin account while logged in as admin: switch:admin> passwd Changing password for admin Enter new password: Re-type new password: Password changed minimum required number of lowercase characters. Fabric OS Command Reference 375 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 402
before the minimum aging period expires. Password contains invalid characters. The password you entered contains invalid characters. See Also login, logout, passwdCfg 376 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 403
value passwdcfg --disableadminlockout passwdcfg --enableadminlockout passwdcfg --setdefault passwdcfg --showall passwdcfg --help Description Use this command to manage password policies. Use --set to configure the following password policies: • Password strength policy • Password history policy - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 404
login attempt counter is maintained for each user on each switch instance. The counters for all user accounts are reset to command prints the usage. --showall Displays all the password configuration parameters. --set Configures a specified password policy. The following arguments are supported - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 405
Setting set to greater than 0 and Admin Lockout policy is enabled, then, if the number of failed login attempts from the last successful login equals the "passwdcfg.lockoutthreshold", the account gets locked for the "passwdcfg.lockoutduration" duration. The particular account is unlocked manually - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 406
at least two uppercase characters, and that passwords expire in 90 days from the date they are defined: switch:admin> passwdcfg --set -uppercase 2 -maxpasswordage 90 Diagnostics The passwdCfg command may fail for any of the following reasons: Permission failure You not permitted to execute the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 407
The -repeat value must be between 1 and 40. sequence value out of range The -sequence value must be between 1 and 40. passwd, userConfig Fabric OS Command Reference 381 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 408
or a path through a switch that does not have active routing tables to the destination, this command displays the path that would be used if the ports were active. If you specify a destination port that is not active, this command uses the embedded port as the destination. For bladed systems, the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 409
is expressed as a sequence of switches, a sequence of output ports or areas, or a combination thereof. The next hop in the source route is described by either the output port or area to be used to reach the next hop, or the domain ID of the next hop. Fabric OS Command Reference 383 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 410
the path described by domains, not to the part described by output ports or areas. Switches running pre-v5.2 firmware cannot use port numbers greater than 256 as a destination port on a remote switch. Note The execution of this command is subject to Admin Domain restrictions that may be in place - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 411
0 Hop In Port Domain ID (Name) Out Port BW Cost 1 3 10 (web229) 12 1G 1000 Port 3 12 Tx Rx Tx Rx B/s (1s) 36 76 0 0 B/s (64s) 5 5 5 5 Txcrdz (1s) 0 - 0 - Txcrdz (64s) 0 - 0 - F/s (1s) 1 1 0 0 F/s (64s) 0 0 0 0 Fabric OS Command Reference 385 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 412
2 pathInfo Words Frames Errors 240434036 20025929 - 2294316 54999 4 2119951 162338 - Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) See Also portStatsShow, switchShow 2121767 56710 0 386 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 413
any arguments, this command displays output from the latest panic dump file available on the switch. If a panic command is run on same PLATFORM as that of pdfile * File :/core_files/panic/core.pd1038932352 * * SECTION:PD_MISC * WatchDogRegister=0x0 Section=Startup time: Tue Dec 3 16 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 414
in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port on which the monitor is to be added, followed by - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 415
perfAddEEMonitor 2 Examples To add an end-to-end monitor to blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number 0 added. See Also perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor, - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 416
Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, this operand specifies the slot number of the port on which the monitor is to be added, followed - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 417
Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, this operand specifies the slot number of the port on which the monitor is to be added, followed - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 418
in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port on which the monitor is to be added, followed by - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 419
in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port on which the monitor is to be added, followed by - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 420
Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, this operand specifies the slot number of the port on which the monitor is to be added, followed - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 421
is optional. By default, the alias is an empty string. Examples To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor #0 added As a special case, to add a filter - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 422
in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port on which the monitor is to be added, followed by - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 423
end-to-end and filter configuration settings of performance monitoring from nonvolatile memory. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 424
changes that were not saved. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Admin Domain restrictions that may - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 425
Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To save the current performance monitoring configuration to firmware: switch:admin> perfcfgsave This will overwrite previously saved Performance Monitoring settings in FLASH. Do you want to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 426
on all platforms. Refer to the Fabric OS Administrator's Guide for specific hardware support. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port on which the monitor is to be added, followed by a slash (/). portnumber - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 427
or all such monitors associated with a port. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 428
to delete a filter-based performance monitor from a port, or all such monitors associated with a port. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 429
Delete filter-based monitor Clear end-to-end/filter-based/ISL monitors Show end-to-end/filter-based/ISL monitors Set overall mask for end-t-end monitors Get ALPA CRC count by port and ALPA Show the current end-to-end mask Install Top Talker monitor See Also none Fabric OS Command Reference 403 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 430
end-to-end and filter-based monitors (but not ISL monitors) for all the ports in the same quad. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 431
: switch:admin> perfmonitorclear --class ISL 1 This will clear ISL monitor on port 1, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor, perfMonitorShow Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 432
command to display performance monitors on a port. Monitor classes include end-to-end monitors (EE), filter-based monitors (FLT), and Inter-Switch ), this command displays the following: Tx_count The 64-bit cumulative ISL transmit count for the whole ISL. Num_ports The number of ports in this - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 433
port on which to display the monitor, relative to its slot for bladed systems. Use switchShow for a list of valid ports. command displays cumulative counts. Examples To display filter monitors on port 8: switch:admin> perfmonitorshow --class FLT 8 There are 2 filter-based monitors defined on port - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 434
26k 179 696 696 696 517 179 26k 187 720 720 720 533 187 26k 200 722 722 722 522 200 26k 204 717 717 717 513 204 To display ISL monitor information on a port: switch:admin> perfmonitorshow --class ISL 1/1 Total transmit count for this ISL: 1462326 Number of destination - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 435
Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. On the Brocade FC4-48, the Area ID address field and the AL_PA ID address field must be masked together. On this blade, one bit of the AL_PA ID address - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 436
To set the overall mask for end-to-end monitors on a port: switch: port will cause ALL EE monitors on this port to be deleted. continue? (yes, y, no, n): [no] y The EE mask on port 6 is set and EE Monitors on this port are deleted See Also perfAddEEMonitor, perfShowPortEEMask 410 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 437
on all platforms. Refer to the Fabric OS Administrator's Guide for specific hardware support. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to be displayed, followed by a slash (/). portnumber Specifies the number - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 438
display the end-to-end mask on a port: switch:admin> perfshowporteemask 2/4 The EE mask onport 20 is set by application NONE TxSID Domain: on TxSID Area: on TxSID ALPA: on TxDID Domain: on TxDID Area: on TxDID ALPA: on RxSID Domain: on RxSID Area: on 412 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 439
perfShowPortEEMask 2 RxSID ALPA: on RxDID Domain: on RxDID Area: on RxDID ALPA: on See Also perfAddEEMonitor, perfDelEEMonitor, perfSetPortEEMask Fabric OS Command Reference 413 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 440
maximum flows displayed are as follows: 32 For the Brocade 300, 5100, 5300, and FC8-xx port blades. 16 For the Brocade 4100, 4900, 5000, 7600, and FC4-xx port blades. 4 For the Brocade 7500. Top Talker supports two modes, Port Mode and Fabric Mode: • In Port Mode, Top Talker is installed on - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 441
is optional. If omitted, the command displays in WWN format. --delete fabricmode Deletes the Fabric Mode Top Talker. Examples To add an F_Port Top Talker to blade 1 port 2 (which should be an F_Port): Switch:admin> perfttmon --add ingress 1/2 Fabric OS Command Reference 415 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 442
dom 101 pid Src_PID Dst_PID MB/sec 0xa908ef 0xa05200 6.926 0xa05200 0xa908ef 6.872 0xa905ef 0xa05200 6.830 0xa909d5 0xa05200 6.772 To delete the Fabric Mode Top Talker: Switch:admin> perfttmon --del fabricmode See Also none 416 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 443
key and CSR and to install a root certificate. This command does not create the switch certificate. Switch certificate should be obtained offline from the Certificate Authority. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 444
that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To remove PKI objects: switch:admin> pkiremove WARNING!!! Removing Pki objects will impair the security functionality of this fibre - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 445
(PKI) objects. Synopsis pkishow Description Use this command to display PKI objects, such as switch private key, private key pass-phrase, CSR, root certificate, and switch certificate. Operands none Examples To view PKI objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 446
to 32, and ALL with the --show option. Optional Operands -enc method 3DES AES-128 AES-256 -auth algorithm SHA-1 MD5 AES-XCBC -pfs value Specifies the encryption algorithm. The default is AES-128. Methods include: Triple data encryption standard, 168-bit key. Advanced encryption standard, 128-bit - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 447
1 Fastest as it uses 768 bit values, but least secure. 14 Slowest as it uses 2048 bit values, but most secure. Security setting: switch:admin> policy --show ipsec 1 IPSec policy 1 Authentication Algorithm: SHA-1 Encryption: 3DES SA Life (seconds): 28800 To display all IKE policy settings: switch - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 448
-enc aes-128 -auth sha-1 The following policy has been set: IKE policy 10 Authentication Algorithm: SHA-1 Encryption: AES-128 Perfect Forward Secrecy: 0 Diffie-Hellman Group: 1 SA Life (seconds): 28800 To delete a policy: switch:admin> policy ike --delete 10 The policy has been successfully deleted - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 449
to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA 0xe2 public 0xe4 type public AL_PA type See Also switchShow Fabric OS Command Reference 423 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 450
to the port based on the estimated distance (as defined by the desired_distance operand of the portCfgLongDistance command). If the port is not MARK primitive that is sent and then echoed back to the switch. LD mode supports distances up to 500 km. Distance measurement on a link longer than 500 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 451
2 Operands When invoked without operands, this command displays the long distance buffer information for all the port groups of the switch. The following operands are optional: slotnumber For bladed systems only, specifies the slot number of the port group to display, followed by a slash - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 452
to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, information for all ports is displayed. Ports that support shared areas are divided into two ports: primary and secondary ports. Primary and secondary ports share the same area. Portcam entries - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 453
64 512 7 0 0 64 512 8 0 0 63 511 9 0 0 63 511 10 0 0 63 511 11 1 1 63 511 12 0 0 46 510 13 0 0 46 510 14 0 0 46 510 15 18 2 46 510 (output truncated) To display the filter CAM utilization for a single port on a switch: switch:user> portcamshow 3/2 Area - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 454
Class of Service (CoS). • Configure IP interfaces on the GbE port. • Guide. Operands This command supports the following port options: slot For bladed systems only, specifies the slot number of the port to be configured, followed by a slash (/). [ge]port Specifies the number of the port - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 455
GbE port. This feature requires supported value is 80. -M Turns on default VC QoS mapping in the specified tunnel. Default is off. There are two ways of prioritizing network traffic over FCIP tunnels: Differentiated Services (DSCP) and Layer 2 Class of Service (L2CoS). If the -M option is set - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 456
Code 16; default is 8. If tape pipelining is enabled, the default value is calculated based 12 and 32 port. Jumbo frames are not supported on secure tunnels. Only a single route is supported on an interface with a secure tunnel. -v vlan_id Creates an FCIP tunnel with VLAN Tagging and Class of Service - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 457
7,200; default is 10. If tape pipelining is enabled, minimum value is 80. -q control_dscp DSCP (DiffServ Code : Differentiated Services (DSCP) and Layer 2 Class of Service (L2CoS). If the -M option is set, the 16; default is 8. If tape pipelining is enabled, the default value is calculated based - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 458
geport all -qosmap command to display current values. Supported range is 0-7. ipif Defines the IP interface for both ports of a tunnel. Up to eight IP interfaces per GbE port are supported. The IP network connection between two 7500 routers or two FC4-18i blades is configured by defining - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 459
port. iproute Defines static IP routes on a GbE port. After defining the IP interface of the remote switch, you can define destination routes on an interface. A maximum of 32 routes per GbE port are supported. IPv6 addresses are supported of a route. Fabric OS Command Reference 433 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 460
port for FC Fastwrite. Enables or disables FC Fastwrite between two Brocade 7500 routersor two Brocade 48000 directors with FR4-18i blades connected by Fibre Channel ISLs. FastWrite mitigateslatency effects on SCSI writes, and improves throughputover a high-latency link. The 434 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 461
blade first should be enabled for FC fastwrite using fastWriteCfg. This command can also be used to list all ports configured for FC fastwrite. This feature requires a Brocade license. The syntax for portcfg fastwrite is as follows: portcfg fastwrite [slot/]port command supports of Service/Priority, - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 462
FCIP tunnel on a 'virtual' E_Port. This command is supported only on a Brocade 7500/FR4-18 platform. A feature key is commands (CCWs) that can enter the write pipeline for a single device whether all the CCWs are bundled in a single channel program or in multiple channel programs. The setting - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 463
-5 Mb. -o |--oxidBase value Defines the base value of an entry pool of 256 OXIDs supplied to emulation-generated exchanges. It should fall outside the range used by FICO channels and devices to avoid conflicts. The default value is 0x1000. The range is 0x0000 to 0xF000. Fabric OS Command Reference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 464
is primarily for use by technical support personnel. ftrace FTRACE is a debug tool primarily for Tech Support personnel. It is implemented as that are routed through the VE port provided by an FCIP tunnel can be traced. The syntax for the portCfg ftrace command is as follows: portCfg ftrace [ - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 465
IP route using IPv4: switch:admin> portcfg iproute ge0 create 172.16.123.231.255.255.0.0 192.168.255.25 1 Operation Succeeded To create a static IP route using IPv6: switch:admin> portcfg iproute 8/ge0 create 3000:4444:800::3456/64 1080::8:800:200C:1234 Fabric OS Command Reference 439 53-1000599 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 466
on port ge0/tunnel 3: switch:admin> portcfg ftrace ge0 3 cfg -a 0 -e 1 -p 5 -s 00000003 -t ffffffff To delete the FTRACE on the same port/tunnel: switch:admin> portcfg ftrace ge0 3 del See Also portCfgShow, portCmd, portShow, switchShow, configure, fastWriteCfg 440 Fabric OS Command Reference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 467
its slot for bladed systems. Use the switchShow command for a list of valid ports. mode Specify a value of 1 to set the AL_PA to 0x13. A value of 0 sets the default AL_PA to 0x0. This operand is required. Examples To configure a port with AL_PA 0x0 (default): switch:admin> portcfgalpa 1/3 0 To - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 468
disable Disables credit recovery configuration on the specified port. --enable Enables credit recoery configuration on the specified port. --help Displays command usage. Examples To enable credit recovery on a port: switch:admin> portcfgcreditrecovery --enable 3/15 To disable credit recovery - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 469
Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slot For bladed systems only, specify the slot number of the port to be reset to default, followed by a slash (/). port Specify the number of the port to be reset to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 470
not exchanged through this port either. Regardless of how many E_Ports are connected between two switches, the maximum routing paths are limited to 16 E_Ports. Notes Changes made by this command are persistent across switch reboots or power cycles. The execution of this command is subject to Admin - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 471
command displays the currently configured values; otherwise, it sets the specified attribute to its new value. The port must be disabled prior to setting EX_Port attributes. The port must be enabled before the port the port is enabled and the state is "OK", the edge fabric principal switch's domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 472
online ports. If the modes are different, an error message is posted, and the command fails. Valid values are as follows: 0 Brocade Native mode. 1 McDATA Open Fabric mode. 2 McDATA Fabric mode. Note that this mapping between mode values and modes is NOT the same as the mapping used when setting - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 473
disable IDID. This command must be issued from a McDATA edge switch attached to a single or dual FCR configuration. Examples To set the fabric ID of port 2/1 to 5 and the port ID format to core: switch:admin> portcfgexport 2/1 -f 5 -p 1 To configure port 2/0 to be an EX_Port and set the fabric ID - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 474
initialization (FL_Port) on the port. A port designated as a G_Port can become an E_Port. This configuration can be cleared but not set on VE/VEX_Ports. Changes made by this command are persistent across switch reboots or power cycles. Note The execution of this command is subject to Admin Domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 475
modes L0.5, L1, and L2 are no longer supported in v5.3.0 or later. Changes made by portCfgISLMode are persistent across switch reboots and power cycles. This configuration can be cleared but not set on VE/VEX_Ports. The execution of this command is subject to Admin Domain restrictions that may be - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 476
2 portCfgISLMode To disable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 0 See Also configure, portCfgLongDistance, portCfgShow 450 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 477
of full size frame buffers on a particular port or to support a long distance link up to 500 km. The port can only be used as an E_Port. Changes made by this command are persistent across switch reboots and power cycles. This configuration can be cleared but not set on VE/VEX_Ports. Long distance - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 478
for the given E_Port are automatically configured based on the actual link distance. Up to buffers required for the port. Examples To configure a switch port 63 to support a 100 km 48 Distance: super long - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 479
: 0 Loss_of_sig: 9 Protocol_err: 0 Invalid_word: 0 Invalid_crc: 0 Delim_err: 0 Address_err: 0 Lr_in: 0 Lr_out: 0 Ols_in: 0 Ols_out: 0 Fbsy: 0 See Also configure, portCfgISLMode, portCfgTrunkPort, portCfgShow, portShow, switchShow Fabric OS Command Reference 453 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 480
; the default value of 0 is used. Private devices are supported only on Brocade enterprise-class platforms with FC2-16 and FC2-16 blades. On all other platforms, option 1 is blocked. duplex_mode Specify 2 to configure the specified port as a full-duplex L_Port with fairness. Specify 1 to configure - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 481
conditions: switch:admin> portcfglport [output from other slots suppressed] Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Locked L_Port ON ON Private L_Port ON Locked Loop HD Loop Fairness See Also configure, portShow, switchShow Fabric OS Command Reference 455 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 482
is enabled on all Condor and Golden-eye-based ports. It can be selectively enabled or disabled on switch ports using this command. NPIV HA: For a redundant control processor (CP) system to enable NPIV functionality, it must be running NPIV-enabled firmware versions on both the active and standby - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 483
QOS E_Port EX Port Mirror Port Rate Limit Credit Recovery where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 See Also configure, portCfgDefault, portCfgShow Fabric OS Command Reference 457 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 484
[port_number | port_range] [mode] Description Use this command to enable or disable N_Port functionality for an Access Gateway port. The enabled N_Port automatically comes online if it is connected to an enterprise fabric switch that supports NPIV. Notes NPIV capability should be enabled on the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 485
. The persistent disable configuration overrides existing port configurations Use the portCfgPersistentEnable command to enable a port persistently and to restore all previously set port configurations for that port. The switch still runs power-on diagnostics and initializes a persistently disabled - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 486
ports on the switch. Persistently enabled ports remain enabled across power cycles, switch reboots, and switch enables. By default, a port is enabled persistently, unless the port is capable of routing. The change in configuration is effective immediately. This command re-enables all previously set - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 487
portCfgPersistentEnable 2 See Also ficonCupSet, ficonCupShow, portDisable, portEnable, portCfgPersistentDisable, portCfgShow, portShow, switchShow Fabric OS Command Reference 461 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 488
limit is set at 4 Gbps and the port comes online only at 2 Gbps, no enforcement is needed. Specify an ingress rate in Mbps. Supported values for --setratelimit are: 200, 400, 600, 800, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 5000, 6000, 7000, 8000. 462 Fabric OS Command Reference 53-1000599 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 489
--help Displays command usage. Examples To enable QoS on a port. switch:admin> portcfgqos --enable 3/15 To disable QoS on a port. switch:admin> portcfgqos --disable 3/15 To set the ingress rate limit on a port to 2 Gbps: switch:admin> portcfgqos --setratelimit 3/15 2000 To set the default QoS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 490
arguments] Description Use this command to display the current configuration of a port. If no operand is specified, this command displays port configuration settings for all ports on a switch, except gigabit Ethernet (GbE) ports. Additionally, use this command with optional arguments to display - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 491
OFF when NPIV capability is disabled. This value is set by the portCfgNPIVPort command. QOS E_Port Displays ON when Quality of Service (QoS) is enabled on the port. Displays (..) or OFF when QoS is disabled. By default, QoS is enabled by best effort based on availability of buffers. This value is - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 492
This command supports the following port options: slot For bladed systems only, specifies the slot number of the port to be configured, followed by a slash (/). [ge]port Specifies the number of the port to be configured, relative to its slot for bladed systems. For GigE ports, the ports are - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 493
ON ON ON ON ON ON ON ON ON ON ON ON ON Ports of Slot 2 16 17 18 19 20 21 22 23 24 25 26 27 28 29 ON ON ON ON To display the configuration settings for a port with Access Gateway enabled: SW4016_5311:admin> portcfgshow Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 494
portCfgShow To display the configuration settings for a single port: switch:admin> portcfgshow 2/16 Area Number: 144 Speed Level: AUTO AL_PA Offset 13: OFF Trunk Port ON Long Distance OFF VC Link 192.168.60.100 Remote WWN Not Configured 468 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 495
0 2 11 3 4 19 3 5 23 3 6 27 0 8 35 0 9 39 0 10 43 4 12 51 4 13 55 4 14 59 4 VC DSCP L2CoS 3 15 3 7 31 0 11 47 4 15 63 port. Refer to the portCfg help page for an explanation of the displayed parameters. switch: admin> portcfgshow vlantag 8/ge0 Port: Command Reference 469 53-1000599- - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 496
nonvolatile memory and is persistent across switch reboots or power cycles. Notes This configuration cannot be set on VE/VEX_Ports. Use portShow to display actual port speed levels. Use portCfgShow to display user-specified speed settings. The execution of this command is subject to Admin Domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 497
a switch. When the command is executed to update the trunking configuration, the port to which the configuration applies is disabled and subsequently re-enabled with the new trunking configuration. Traffic through the ports may be temporarily disrupted. Disabling trunking fails if a Trunk Area (TA - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 498
command displays the currently configured values; otherwise, it sets the specified attribute to its new value. The port must be disabled prior to setting VEX_Port attributes. The port must be enabled before the port the port is enabled and the state is "OK", the edge fabric principal switch's domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 499
0 Brocade Native mode. 1 McDATA Open Fabric mode. 2 McDATA Fabric mode. Note that this mapping between mode values and modes is NOT the same as the mapping used when setting interoperability modes with the interopMode command. Examples To display the VEX_Port configuration of port 2/16: switch - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 500
as a VEX_Port and set the fabric ID to 4: switch:admin> portcfgvexport 2/20 -a 1 -f 4 To disable fabric parameter negotiation on port 2/20 of a VEX_Port: switch:admin> portcfgvexport 2/20 -t 2 See Also portCfgEXPort, portDisable, portEnable, portShow 474 Fabric OS Command Reference 53-1000599 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 501
[slot/]geport arguments Description Use this command to invoke the end-to-end IP path performance (ipperf) characterization feature, or to ping or trace route to a destination IP host from an intelligent GbE port. Notes Virtual LAN (VLAN) tagging is supported on the Brocade FR4-18i and all 7500 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 502
path performance based on the 48 bytes.The total size, including ICMP/IP headers (28 or 48 -of-Service Specifies Class of Service/Priority port. Valid arguments include: -s src_ip Specifies the source IP address that originates the ping request. IPv6 addresses are supported. 476 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 503
IP router path. IPv6 addresses are supported. -h max_hops Specifies the maximum hop limit used in the outgoing probe packets. This operand is optional. -f first_ttl Sets the starting time to live to the value of this parameter. The default is 1. The command skips processing for those intermediate - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 504
the destination IP address with maximum wait_time specified: switch:admin> portcmd --ping 12/ge0 -s 2007:7:30:32:227:138:10:120 -d \ 2007:7:30:32:227:77:0:60 -w 29000 Pinging 2007:7:30:32:227:77:0:60 from ip interface 2007:7:30:32:227:138:10:120 on 12/ge0 with 64 bytes of data Reply from 2007:7:30 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 505
level to be set for port modules; valid values are 1 to 5. vbs_lvl Specify the verbose level to be set for port modules; valid values are 1 to 5. Examples To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow Fabric OS Command Reference 479 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 506
, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To disable a port: switch:admin> portdisable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portEnable, portShow, switchShow 480 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 507
be sent to indicate a state transition: RSCN, SNMP trap, Web pop-up window. This command fails if the port's switch is disabled, the port's blade is not fully enabled (faulted, powered off, or disabled), or if the port is persistently disabled. Notes The front panel LED of an enabled and online - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 508
error counters for ports on a switch: switch:admin> porterrshow frames 12 14 0 0 0 0 0 0 0 0 3 6 0 0 7: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 29: 0 0 - 0 0 0 0 - 0 - - - - 30: 0 0 - 0 0 0 0 - 0 - - - - 31: 0 0 - 0 0 0 0 - 0 - - - - (output truncated) See Also portShow, portStatsShow 482 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 509
port status bitmaps for all ports in a switch. Synopsis portflagsshow Description Use this command to display the following status for a port: SNMP Displays whether the port is online or offline. Physical Displays the port Offline No_Light PRESENT LED 1 12 Online In_Sync PRESENT ACTIVE - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 510
to exercise the user port LEDs in the current switch on and off by setting the ATTN LEDs to green for the ON condition and unlighted for the OFF condition. The SPEED LEDs are initially set to black before the command execution. The SPEED LEDs are set to green once the command is executing. You must - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 511
that may be in place.Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 512
be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize 486 Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 513
is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To display the port log facility: switch:admin> portlogdisable See Also portLogEnable Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 514
Administrator's Guide. Operands This command has the following operands: count Specify the maximum number of lines to be displayed. Only the most recent count entries are displayed. This operand is optional. saved Specify a nonzero value to display the saved port log from the last switch fault - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 515
Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operand: portid Specify the port area or index number. Examples To display the port log dump for a port: switch:user> portlogdumpport 14 time task event port cmd args 08:35 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 516
subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable the port log facility: switch:admin> portlogenable See Also portLogDisable 490 Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 517
this command to display information about the ID associated with the various port log events. The Disabled field indicates whether the port log for that event ID is disabled (1) or enabled (0). Operands none Examples To display information about port log events: switch:admin> portlogeventshow - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 518
the following bits: 4 Class 2 is supported. 8 Class 3 is supported. Further information about each login is displayed after these columns, including the Port ID of the well-known address or N_Port that was the target of the PLOGI, if applicable. Note The execution of this command is subject - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 519
" for details. Operands This command has the following operand: 0|1 Specify 0 to clear or 1 to set the debug_pdisc_flag. The default is 0. Examples To set the debug_pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See Also none Fabric OS Command Reference 493 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 520
Domain restrictions that may be in place.Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable the port log: switch:admin> portlogreset See Also none 494 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 521
. Operands This command has the following operand: num_entries Specifies the number of port log entries. The valid range of values is 32,768 to 65,536 for the Brocade 48000 and the Brocade 7500. For all other platforms, the range is 8,192 to 16,384. Examples To resize the portlog: switch:admin - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 522
Description Use this command to display the port log, page by page. The portLogShow command displays the same information as portLogDump, but it enables you to press Enter after each page of output. Port logs are circular log files in the switch firmware, which can save up to 32,768 entries. Refer - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 523
Exchange state. Frame payload. Displays the port number that logged the event. Defined by the event. Displays a value defined by the event as follows: I/O control command code. Frame payload size. New state (see state codes below). New physical state (see pstate codes below). The CT-subtype: Simple - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 524
. FC-PH busy reason. Argument 0 is divided into two 16-bit fields: [A] a bit map indicating whether subsequent arguments are valid (0001 means argument 1 is valid, 0003 means arguments 1 and 2 are valid). [B] the CT-based service command code. Argument 1 is the first word of the CT payload - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 525
portLogShow 2 Codes used in various fields are as follows: state 1 8001 Retry loop init. 8002 Start loop after gaining sync. 8003 Restart loop after port reset. 8004 LIP when a loop hangs. 8005 Restart loop if LIP received when follows. Fabric OS Command Reference 499 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 526
complete. Operands This command has the following operands: count Specify the maximum number of lines to display. Only the most recent count entries are displayed. This operand is optional. saved Specify a nonzero value to display the saved port log from the last switch fault. Refer to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 527
Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: portid Specify the number of the port for which to display the log. Examples To display a port log for port 14: switch:user> portlogshowport 14 time task event - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 528
values corresponding to different log types can be obtained by running portLogEventShow. Examples To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable 502 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 529
type to be enabled. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable Fabric OS Command Reference 503 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 530
[--slot number][-nframes count][-lb_mode mode][-spd_mode mode] [-ports itemlist] Description Use this command to verify the functional operation of the switch by sending frames from the port N transmitter and looping them back into the same port N receiver. The loopback is done at the parallel - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 531
the blade ports in the specified slot (--slot) are used. See itemList for more information on the itemlist parameter. Examples To run a functional test of a connection: switch:admin> portloopbacktest -ports 1/10-1/20 -nframes 1 -lb_mode 1 Running Port Loopback Test .... passed. Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 532
2 portLoopbackTest Diagnostics Following are possible error messages if failures are detected: DATA ERRSTAT INIT PORTDIED STATS TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList 506 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 533
configured in the hardware. A new connection cannot conflict with a "Defined" or "Enabled" port mirror connection. To display all configured mirror ports on a switch, use the portCfgShow command. Setting up multiple mirror connections on a core-edge platform between devices mirrors additional - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 534
of a mirror port, the command shows double the amount of traffic because the mirror port transmits the frame and also receives the frame. Notes The port mirroring feature is only supported on the following platforms: Brocade 4100, Brocade 4900, Brocade 7600, and Brocade 48000 set to chassisConfig - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 535
0x011400 0x240400 To display port mirror connections: switch:admin> portmirror --show Number of mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled See Also portCfgShow Fabric OS Command Reference 509 53-1000599 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 536
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). portnumber Specify - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 537
Use this command to display throughput information for all ports on the switch. Output includes link may not match the output on the device port. Examples To display port throughput for a switch: switch:user> portperfshow 20 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Total slot 1: 0 0 23k - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 538
in the other tables; however, this table typically has only Bit 16 set (value 0x10000), indicating this port always routes broadcast frames to the embedded port, for handling by the firmware. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 539
4/15 port address ID: 0x02bf00 external unicast routing table: 1: 0x4 (vc=3) 2: 0x10000 (vc=0) internal unicast routing table: 60: 0x8000 (vc=2) 63: 0x1000 (vc=5) broadcast routing table: 0x10000 See Also bcastShow, fabricShow, switchShow, topologyShow, uRouteShow Fabric OS Command Reference 513 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 540
Fibre Channel over IP (FCIP) tunnel configuration settings • Port Mode information • FICON parameters • VLAN tag configuration • FTRACE settings The following general information is displayed when the command is issued for a non-GbE port without additional arguments: portName Name assigned to the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 541
not active) or actual (if active) domain ID for the front domain and the WWN of the front domain. Pr Switch Info Information on the principal switch of the edge fabric attached to this EX_Port. Includes the domain ID and WWN of the principal switch. Fabric OS Command Reference 515 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 542
The xlate phantom domain connected at this port is in the same fabric as the is the only authentication type supported on EX_Ports. DH Group switch with FCS policy enforcement, the version of the security database is displayed. Otherwise displays N/A. Following the general information, the command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 543
complete device information attached to the port is shown in the output. This command supports the following port options: slot For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). [ge]port Specify the port number to be displayed relative to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 544
settings. ftrace FTRACE is a debug tool for developers and support (not intended for customer use). For usage information, execute portShow ftrace. Examples To display the state of a port: switch In_Sync portScn: 64 Segmented port generation number: 12 portId: Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 545
12 Lr_in: 4 Lr_out: 7 Ols_in: 2 Ols_out: 3 Port part of other ADs: No To view xlate domains, you must be running a Brocade 7500 or 48000 with an FC4-18i blade. Note that the Front Domain ID is what is shown: switch : 0 Frjt: 0 Fbsy: 0 Fabric OS Command Reference 519 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 546
, 192.168.255.0 255.255.255.0 192.168.255.27 0 Interface, 172.16.123.231 255.255.0.0 192.168.255.25 1 To display ISCSI Port WWN and Sessions: switch:admin> portshow iscsi 2/ge0 GE Port 2/ge0 Port WWN Sessions 50:06:06:9e:40:09:a2:00 0 520 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 547
as control connection: switch:admin> portshow fciptunnel 9/ge0 0 -params Slot: 9 Port: ge0 Tunnel ID Status : Active Connected Count: 1 Uptime 2 hours, 12 minutes, 52 seconds FC control traffic TCP connection: Local transfer TCP connection: Local 10.10.9.100:4100, Remote 10.62.0.100:3226 Runtime - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 548
on an FCIP tunnel: switch:admin> portshow fciptunnel 9/ge0 0 -perf Slot: 9 Port: ge0 Tunnel ID 0 : Active Connected Count: 1 Uptime 2 hours, 12 minutes, 5 seconds QoS shaper performance stats: 48152162 Bytes Bps 30s avg, 3695 Bps lifetime avg 1.64 compression ratio FC control traffic TCP connection: - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 549
on an FCIP tunnel on a GbE port: switch:admin> portshow fciptunnel 9/ge0 0 -ipsec Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr Encryption: AES-128 Perfect Forward Secrecy: on Diffie-Hellman Group: 14 SA Life (seconds): 28800 IPSec Policy 1 Authentication Algorithm: SHA-1 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 550
Encryption: AES-128 SA Life (seconds): 28800 Pre-Shared Key testingFIPSandIPSec To show the ARP entries with local MAC address for a GbE port: switch:admin> portshow arp 12/ge0 -lmac Port 26366 iac_credits_posted: 32 iac_credits_queued: 0 : 524 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 551
for a GbE port 0 tunnel ID 1 with post display clearing of relevant statistics: switch:admin> portshow ficon ge0 1 -epcb -clear To display a list of discovered devices and selected path and status information on each. Get the adrs from this display for the next command: switch:admin> portshow ficon - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 552
2 portShow This command displays the same information as the previous but posts selected statistical areas: switch:admin> portshow ficon ge0 all -fdcb 10008000 -clear See Also authUtil, portCfg, portCfgLongDistance, portLoginShow, portName, switchShow 526 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 553
portStats64Show 2 portStats64Show Displays the 64-bit hardware statistics for a port. Synopsis portstats64show [slotnumber/]portnumber Description Use this command to display the following hardware statistics for a port. Two integers are reported for most values. In such cases, the top word is - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 554
Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port bladed systems. Use switchShow to display a list of valid ports. Examples To display the 64-bit hardware statistics for a port: switch: - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 555
stat64_inputBuffersFull 0 top_int : 4-byte words transmitted 0 bottom_int : 4-byte words transmitted stat64_rxClass1Frames 0 top_int : 4-byte words transmitted 0 bottom_int : 4-byte words transmitted See Also portStatsClear, portStatsShow Fabric OS Command Reference 529 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 556
(/). port Specify a port number to be cleared, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To clear hardware statistics for a port: switch:admin> portstatsclear 4/15 See Also portStats64Show, portStatsShow 530 Fabric OS Command Reference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 557
| tunnelnumber] Description Use this command to display port hardware statistics counters. Some counters are platform- and port-specific and display only with those platforms and ports. All statistics have a maximum 32-bit value of 4,294,967,295. The command output includes the following fields - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 558
tunnel. Examples To display the basic set of statistics for port 1/0 on a DCX backbone: switch:admin> portstatsshow 13 stat_wtx 1979747673 stat_wrx 618367 stat_ftx 1958745847 4-byte words transmitted 4-byte words received Frames transmitted 532 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 559
: time_txcrd_z_vc 12-15: er_enc_in bad end-of-frame Encoding error outside of frames Invalid ordered set Class 3 frames discarded due to timeout Class 3 frames discarded GbE port statistics for slot 8 and GbE port 1: switch: Errors 0 GE abort frames Fabric OS Command Reference 533 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 560
fcip_entity pkts 0 ve to fcip_entity bytes To display port statistics for all IP addresses, slot 8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 ip_err_crc ip_err_hdr_cksum ip_err_tcp_data_chksum 0 Errors See Also portErrShow, portShow 534 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 561
, relative to its slot for bladed systems. Examples To swap area numbers between a pair of ports: switch:admin> portswap 1/3 2/5 portswap done See Also portDisable, portEnable, portShow, portSwapDisable, portSwapEnable, portSwapShow, switchShow Fabric OS Command Reference 535 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 562
and power cycles. Enabling or disabling the portswap feature does not affect previously performed portswap operations. Note The execution of this command is Appendix A, "Command Availability" for details. Operands none Examples To disable the portswap feature: switch:admin> portswapdisable - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 563
and power cycles. Enabling or disabling the portswap feature does not affect previously performed portswap operations. Note The execution of this command is Appendix A, "Command Availability" for details. Operands none Examples To enable the portswap feature: switch:admin> portswapenable - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 564
portswapshow Description Use this command to display the enabled state of the portswap feature, as well as port and area information for ports whose area number differs from the default area number. The default area number of a port is the same as its switch port number. Operands none Examples - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 565
Refer to the portTestShow command for more information. If there is a port type change during portTest execution, the test continues on a given port as long as it can be supported and it is asked to do so. If a request was made to test all possible ports on a given switch, portTest starts a new test - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 566
: -1 All ports (default). -2 All L_Ports. -3 All F_Ports. -4 All E_Ports. -5 All N->N loopback ports. Examples To run a functional test on an active switch: switch:admin> porttest -ports 1/1-1/3 See Also portLoopbackTest, portTestShow, spinFab, stopPortTest 540 Fabric OS Command Reference 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 567
. Operands This command has the following operand: -ports itemlist Specify a list of user ports to test. By default, all user ports in the current slot is assumed. Refer to the itemList help page for further details. Examples To display information from portTest: switch:admin> porttestshow - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 568
, displays the trunk index. Trunk Area On single processor switches only, displays the TA of the trunk group. ptA->ptB ptA indicates the local user port; ptB indicates the remote user port. sp Port speed in Gbps. bw Port bandwidth in Gbps. 542 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 569
from different Admin Domains are not allowed to join the same Trunk Area group. 11. On the Brocade FC4-48C, F_Port masterless trunk ports are not supported on ports 16 - 47. 12. Ports included in a TA share the same port index. The original port index may be removed in the process. This means that - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 570
for the static TA to be created. The TA must fall within the 8 port trunk group starting from port 0 on a switch or blade. The TA must be a default area of an existing port in a given port group. However, you may add ports to the trunk group even when a trunk group has already been assigned by - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 571
:05:1e:41:22:80 zoning: OFF switchBeacon: OFF FC Router: ON FC Router BB Fabric ID: 100 Area Port Media Speed State Proto 0 0 -1 1 -2 2 -3 3 -4 4 -5 5 -6 6 -7 7 -8 8 id 9 9 -10 10 -11 11 -12 12 -13 13 -14 14 -15 15 -16 16 -17 17 -18 18 -19 19 -20 20 -21 21 -22 22 -23 23 -24 24 -25 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 572
reissue the command: switch:admin> porttrunkarea --disable 36-39 Trunk area 37 disabled for ports 36, 37, 38 and 39. To display trunk details for a user assigned TA 38 that includes ports 36-39: switch:admin> porttrunkarea --show trunk Trunk Area 38: 39->23 sp: 4.000G bw: 16.000G deskew 16 MASTER 38 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 573
the TA port configuration after enabling the ports: switch:admin> porttrunkarea --show enabled Slot Port Type State Master TI DI 10 13 F-port Master 10/13 125 125 10 14 F-port Slave 10/13 125 126 portCfgTrunkPort, portCfgShow, portShow, switchCfgTrunk, switchShow Fabric OS Command Reference 547 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 574
the enforced zone type of the F_Ports and FL_Ports of a switch. Synopsis portzoneshow Description Use this command to display the enforced zone type of the F_ports and FL_Ports of a switch. Output shows virtual port number (decimal), physical port number (decimal), online status, and if online - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 575
blades can be powered up. The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To modify the power-off list order: switch - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 576
New POL Power Off Order 10 1 1st 9 2 2nd 8 3 3rd 7 4 4th 4 10 5th 3 9 6th 2 8 7th 1 7 8th Proceed to change the POL order? (yes, y, no, n): [no] y See Also chassisShow, powerOffListShow, psShow, slotPowerOff, slotPowerOn, slotShow 550 Fabric OS Command Reference 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 577
state (in which the power supply is still supplying power), the power-off list is processed as described. Notes Command output may vary depending on the hardware platform. Control processor (CP) blades are not included in the power-off list. The execution of this command is subject to Admin Domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 578
. Synopsis psshow Description Use this command to display the current status of the switch power supplies. The status of each supply is displayed as: OK Power supply functioning correctly. absent Power supply not present. unknown Unknown power supply unit installed. predicting failure - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 579
Reboots the control processor (CP) in a switch or a director. Synopsis reboot -f Description When this command is issued on a switch, if the switch is part of a fabric, all traffic to and from that switch stops. All Fibre Channel ports on that switch including E_Ports become inactive until the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 580
of routing-related commands: switch:admin> routehelp aptpolicy bcastshow dlsreset dlsset dlsshow fspfshow interfaceshow iodreset iodset iodshow ioddelayset ioddelayreset ioddelayshow linkcost lsdbshow nbrstateshow nbrstatsclear topologyshow urouteconfig urouteremove urouteshow Get and set Advanced - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 581
an Active CP that runs Fabric OS v6.0.0. The Brocade 200E is unable to handle the maximum DB size supported in v6.0.0 and issues a compact flash warning when the active security database is close to the 1MB limit. The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 582
--set This command sets up secret keys for the DH-CHAP authentication. The minimum length of a secret key is 8 characters and maximum 40 characters. Setting up secret keys does not initiate DH-CHAP authentication. If switch is configured to do DH-CHAP, it is performed whenever a port or a switch is - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 583
secret that authenticates peer. Press Enter to start setting up shared secrets > Enter WWN, Domain, or switch name (Leave blank when done): 10:00:00 Done. To delete the entire secret key database: switch:admin> secAuthSecret --remove --all This command deletes database of DH-CHAP secret keys. If - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 584
party certificates on a switch, including Public Key Infrastructure (PKI) based certificates and Lightweight Directory Access Protocol (LDAP) certificates. This command also imports or exports Certificate Signing Requests (CSRs) from or to a remote host. This command supports IPV4 and IPV6 addresses - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 585
prompts for confirmation unless -nowarn is specified. gencsr Generates a new CSR for the switch. This is the second step in setting up a third-party certificate. The following operands are optional; if omitted, the command prompts for answers to a series of questions. If only one or a few operands - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 586
This operand is optional. export Exports a CSR to a host. This command is typically used to submit a CSR to the Certification Authority (CA) ; if omitted, the command prompts interactively for your input. -ldapcacert file name Exports an LDAP CA certificate from the switch to a remote host. - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 587
generate a CSR in interactive mode: switch:admin> seccertutil gencsr Country Name (2 letter code, eg, US):US State or Province Name (full name, eg, California):California Locality Name (eg, city name):San Jose Organization Name (eg, company name):Brocade Organizational Unit Name (eg, department or - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 588
:admin> seccertutil gencsr -country US -state California -locality "San Jose" \ -org Brocade -orgunit software -cn 192.168.38.206 generating CSR, file name is: 192.168.38.206.csr Done To delete the CSR in interactive mode: switch:admin> seccertutil delcsr WARNING!!! About to delete CSR: 192.168 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 589
To delete an LDAP CA certificate in interactive mode: switch:admin> seccertutil delete -ldapcacert filename.pem WARNING!!! About switch:admin> seccertutil showcsr | more To display the content of a certificate: switch:admin> seccertutil show certificate_name See Also none Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 590
command also displays the maximum database size. Notes For switches running Fabric OS v6.0.0 and later, the maximum security database size is 1 MB. For switches running earlier versions of Fabric OS (up to v5.3.0), the maximum is 256 KB. The effective security DB size is the lowest supported by - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 591
This command is intended primarily for debugging purposes by technical support staff. The information displayed may not be supported between Empty Primary Version 0 Primary WWN 10:00:00:05:1e:01:23:e0 (local switch) Stamp 0 ----The latest zone transaction-last retVal from zone: not used last zone - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 592
receives notification 14:08:50 850588912 secProcessIPChange starts processing 14:08:50 850588912 secProcessIPChange acks completion [Output truncated] See Also secActiveSize, secDefineSize 566 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 593
existing policies Moves a member in the FCS policy Removes members from an existing policy Saves defined policy set and sends to all switches Shows members of one or more policies Resets security statistics Displays security statistics See Also none Fabric OS Command Reference 567 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 594
changes to policy creation and modification operations from all the switches if a fabric-wide consistency policy is not set for the particular policy. Notes When FCS Policy is enabled, this command can be issued only from the Primary FCS switch. Only the user who made the changes to the defined - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 595
Saves and activates the Defined Security Policy Set. Synopsis secpolicyactivate Description Use this command to activate the current defined security policy to all switches in the fabric. This activates the policy set on the local switch or all switches in the fabric depending on the fabric - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 596
is an exception). Notes When FCS Policy is enabled, this command can be issued only from the Primary FCS switch. The secpolicyadd command can be issued on all switches for SCC and DCC policies as long as fabric-wide consistency policy is not set for the particular policy. Do not add the WWNs of - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 597
WWN strings, domain IDs, or switch names. If domain ID or switch names are used, the switches associated must be present in the fabric or the command fails. DCC_POLICY Members The DCC_POLICY_nnn is a list of devices associated with a specific switch and port combination. An empty DCC_POLICY does not - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 598
a unique policy for each port in the fabric locking it down to the device connected or creating an empty policy to disallow any device to be connected to it. This can be done only when there are no other DCC policies defined on the switch. 572 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 599
attached to those ports. SCC_POLICY and FCC_POLICY Members This policy type requires member IDs to be specified as WWN strings, domains, or switch names. If domain or switch names are used, the switches associated must be present in the fabric or the command fails. To add all switches in the current - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 600
200: fffcc8 10:00:00:05:1e:35:cd:ef 10.32.69.117 10.20.30.117 "nSW4100_98" 3. Create a SCC policy that includes switches with domain IDs 2 and 4. switch: switch:admin> secpolicyactivate About to overwrite the current Active Policy Set. ARE YOU SURE (yes, y, no, n): [no] y secpolicyactivate command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 601
members. If the policy is deleted all access is granted. Notes When an FCS policy is enabled, this command can be issued only from the Primary FCS switch. The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 602
2 secPolicyDelete See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow 576 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 603
Appendix A, "Command Availability" for details. This command can be issued from all FCS switches in the fabric. Operands This command has the 15:5c 1 primaryfcs 2 No 10:00:00:60:69:30:1e:62 4 switch ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10:00:00:60:69:30:15 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 604
2 secPolicyDump See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyRemove, secPolicySave, secPolicyShow 578 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 605
position 3 to position 1 in the FCS list (non-interactively): switch:admin> secpolicyshow ACTIVE POLICY SET 1 Yes 10:00:00:05:1e:39:5f:67 2 switch1 2 No 10:00:00:05:1e:04:ef:0e 4 switch2 3 No 10:00:00:05:1e:35:cd:ef 200 switch3 Fabric OS Command Reference 579 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 606
About to overwrite the current Active Policy Set. ARE YOU SURE (yes, y, no, n): [no] y secpolicyactivate command was completed successfully. switch:admin> secpolicyshow ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10:00:00:05:1e:35:cd:ef 200 switch3 2 No 10:00:00:05 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 607
associated with a specific switch and port combination. The device is specified with a WWN string. The switch and port combination must be specified in the switch port format where switch can be specified by switch WWN, domain, or switch name. The port Fabric OS Command Reference 581 53-1000599 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 608
and 9 and all devices attached to those ports. [1-3, 5] Selects ports 1 through 3 and 5 and all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. Examples To remove a member that has a WWN of 12:24:45:10:0a:67:00:40 from SCC policy - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 609
, and FCS policies to the Defined Security Policy Set on the local switch. Notes This command is always a local switch operation. A fabric-wide consistency configuration does not affect the behavior of this command. The execution of this command is subject to Admin Domain restrictions that may be - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 610
to display the members of an existing policy in the Active or Defined security policy set. The command can be issued from all FCS switches. This command displays the policy database one page at a time. Use secPolicyDump to display the policy database without page breaks. Note The execution of - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 611
POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10:00:00:60:69:30:15:5c 1 primaryfcs 2 No 10:00:00:60:69:30:1e:62 4 switch fddCfg, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 612
. If FCS policy is enabled and secStatsReset is issued on the primary FCS switch, this command can reset security statistics for any or all switches in the fabric. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 613
a list of domains, separated by semicolons and enclosed in quotation marks. This option can only be executed when FCS policy is enabled and when the command is issued from the primary FCS switch. When domain is specified, the name operand is required. Examples To reset all statistics on the local - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 614
Displays one or all security statistics. Synopsis secstatsshow [name[, "domain[;domain]"]] Description Use this command to display one or all security statistics. This command can be issued on any switch to display local security statistics. If FCS policy is enabled and secStatsShow is issued on - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 615
in the fabric or specify a list of domains separated by semicolons. This option can only be executed when FCS policy is enabled and the command is issued from the primary FCS switch. When domain is specified, the name operand is required. Examples To display the MS_POLICY statistics on the local - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 616
sensor readings. Synopsis sensorshow Description Use this command to display the current temperature, fan, and power supply status and readings from sensors located on the switch. The actual location of the sensors varies, depending on the switch type. Operands none Examples To view all - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 617
of debug messages to the serial console. By default, no debug messages are displayed. High debug level values can generate a large volume of messages, degrading the system response time. The set of supported modules and their current debug levels are displayed by the command dbgShow. Note The - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 618
c 1 b 0 a ! ! POWER SUPPLY 3 ! ! POWER SUPPLY 2 ! ! scale: 1/8" = 1" POWER SUPPLY 1 & 3 POWER SUPPLY 2 & 4 200-240 VAC 12A 50-60 Hz 200-240 VAC 12A 50-60 Hz POWER SUPPLY 1 2.015 Modem dial-in must be through a Hayes-compatible modem attached to a CP modem serial port. When the CP is active - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 619
a separate modem is connected to each modem port of CP0 and CP1. These modems connect to command is not supported on the Brocade DCX backbone. Operands The optional operands are as follows: -e Enables modem dial-in. -d Disables modem dial-in. Examples To disable modem dial-in to a CP: switch - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 620
Specifies module verbose level. Synopsis setverbose [module_name][level] Description Use this command to set the verbose level of the specified module. These levels filter the display of the debug message to the serial console. By default, no debug messages are displayed. Note The execution - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 621
information, relative to its slot for bladed systems. Use switchShow for a list of valid ports. This operand is optional; if omitted, this command displays a summary of all SFPs on the switch. -all Displays detailed data for all available SFPs on the switch. This operand is not compatible with - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 622
BR Max: 0 BR Min: 0 Serial No: H11QET9 Date Code: 020429 Temperature: 50 Centigrade Current: 10634 mAmps Voltage: 3164.8 mVolts RX Power: 199.6 uWatts TX Power: 235.2 uWatts To display detailed information for GbE port 0 on a Brocade 7500: switch:admin> sfpshow ge0 Identifier: 3 SFP - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 623
Tx_Fault,Tx_Disable BR Max: 5 BR Min: 5 Serial No: 21P7053164529 Date Code: 01060501 Port 1 Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Baud Rate: 21 (units 100 megabaud) Fabric OS Command Reference 597 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 624
Name: IBM Vendor OUI: 08:00:5a Vendor PN: IBM42P21SNY Vendor Rev: AA10 Wavelength: 0 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 5 BR Min: 5 Serial No: 21P70530005BW Date Code: 01062301 (output truncated) switchShow 598 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 625
console serial port. This command cannot run from a Telnet session. This setting is saved in the configuration database; therefore, it is persistent across reboots and power cycles. A, "Command Availability" for details. Operands none Examples To disable flow control: switch:admin> - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 626
serial port. This command cannot run from a Telnet session. This setting is saved in the configuration database; therefore, it is persistent across reboots and power the switch might reboot. It is recommended to disable the flow control, using shellFlowControlDisable. The execution of this command is - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 627
Specify the slot number of the blade to be powered down. This operand is required. Examples To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow Fabric OS Command Reference 601 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 628
Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operand: slotnumber Specify the slot number of the blade to be powered on. This operand is required. Examples To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. See - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 629
port blade 36 FC4-48 port blade 39 FC10-6 port blade 50 CP8 control processor blade 52 Core8 switch blade 37 FC8-16 port blade 55 FC8-32 port blade 51 FC8-48 port blade Status Displays the status of the blade as one of the following: VACANT The slot is empty. INSERTED, NOT POWERED - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 630
SAS Virtualizaion services are disabled. Only applies to the FA4-18 blade. DISABLED The blade is powered on but disabled. FAULTY The blade is faulty because an error was detected. UNKNOWN The blade is inserted but its state cannot be determined. Operands This command supports the following - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 631
BTU) Power Efficiency: 9.91 watts per port, 2.48 watts per Gb To display Brocade model names for each blade in the chassis: switch:user> slotshow -m Slot Blade Type ID Model Name Status 1 AP BLADE 33 FA4-18 ENABLED 2 SW BLADE 55 FC8-32 ENABLED 3 SW BLADE 37 FC8-16 ENABLED - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 632
settings. The command supports set, reset to default, and display operations. All values successfully changed by this command take effect immediately and are persistent across power parameters. These parameters include access host subnet area and access permission (read-write). mibCapability - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 633
string should be in range of 2 to 16 characters. The default values for the community on the primary FCS switch only, and only the primary FCS switch propagates changes across the supported. Separate default passwords are provided for creation of authKey and privKey for each entry. The default set - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 634
nonprimary switches, and unlike community strings, user names and passwords are not distributed for other switches in set/trap operations to hosts under a host-subnet-area. Host-subnet-area is defined by comparing nonzero IP octets. For example, an ACL of 192.168.64 Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 635
to modify existing settings: SNMP security level Specifies security level for all SNMP requests. SNMP SET security level Specifies security level for SNMP SET requests only. Values are: 0 No security. 1 Authentication only. 2 Authentication and Privacy. 3 OFF Fabric OS Command Reference 609 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 636
access control configuration: switch:admin> snmpconfig --set accessControl SNMP access list configuration: Access host subnet area in dot notation: [0.0.0.0] 192.168.0.0 Read/Write? (true, t, false, f): [true] Access host subnet area in dot notation: [0.0.0.0] 10.32.148.0 Read/Write? (true, t, false - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 637
command will reset the agent's system group configuration back to factory default ***** sysDescr = Fibre Channel Switch sysLocation = End User Premise sysContact = Field Support authTraps = 0 (OFF) ***** Are you sure? (yes, y, no, n): [no] y To set the security level: switch:admin> snmpconfig --set - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 638
"A Simple Network Management Protocol (SNMPv1)" RFC1213, "Management information Base for Network Management of TCP/IP-based internets: MIB-II" RFC2574, "User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)" 612 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 639
occur. If multiple ISL links are present between two switches that support trunking, then it is likely that trunk groups are present and all ports between the two switches should be tested at the same time. Note The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 640
test normally logs errors but does not set the port status to FAILED. This parameter is provided to force the failing ports to be marked as FAILED in the same manner as other diagnostics. In test or qualification environments without live traffic, this command may be useful with large -nmegs counts - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 641
Refer to the Fabric OS Message Reference for more information. See Also itemList, portLoopbackTest spinFab 2 Fabric OS Command Reference 615 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 642
which use secure copy (SCP), such as configDownload/configUpload. This command supports generation of a public/private key pair on the switch to enable outgoing connections between a switch and a remote host. To set up incoming connections, you must first generate the public/private key pair - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 643
a remote host to the local switch. This operation supports authentication for incoming connections. For this operation to succeed, a public/private key pair must be generated on the remote host prior to the import by issuing ssh-genkey -t dsa (a UNIX command). importpubkey can only be performed by - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 644
host to support outgoing connections from the switch to a remote host. This option can only be performed by a configured user. The successfully exported public key must be appended to the authorized_keys file on the remote host. Use the cat ~/.ssh/outgoing.pub >> ~/.ssh/authorized_keys command to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 645
To set up SSH public key authentication on a switch for outgoing connections: 1. Generate a private/public key pair on the local switch: switch: private key on a switch: switch:username> sshutil delprivkey private key is deleted successfully. See Also none Fabric OS Command Reference 619 53- - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 646
][-use_bports value] Description Use this command to clear the port and diagnostics statistics for the specified list of blade or user ports. You can issue this command on the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 647
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands This command has the following operand: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help pages - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 648
. --enable Enables the FFDC. --show Displays the FFDC configuration parameters. When executed without operands, the command prints the usage. Examples To display the FFDC configuration: switch:admin> supportffdc --show First Failure Data Capture (FFDC) is disabled. To enable the FFDC events - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 649
the password is not needed. password should be less than 48 characters. -d remotedirectory Specifies the remote directory for storing trace command defaults to supportFtp -S. Examples To set the FTP parameters: switch:admin> supportftp -s -h 1080::8:800:200C:417A -u njoe -p password -d support - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 650
changed. To enable auto file transfer: switch:admin> supportftp -e support auto file transfer enabled. See Also To disable auto file transfer: switch:admin> supportftp -d support auto file transfer disabled. supportSave, supportShow, traceDump 624 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 651
files and panic dumps remain on the switch after the command is run. The FFDC data are removed after the command has finished. If there are BP blades installed on the switch, a support file (a.tar.gz file) is generated from each slot. This command accepts IPv4 and IPv6 addresses. If the configured - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 652
the supportSave command prior to its use with various scp mode services. Because the supportSave command makes several MB/s Saving support information for switch:Stealth200E, module:CHKCONFIG... ...files/Stealth200E-S0-200802171132-CHKCONFIG.ss.gz: 290.00 B 7.54 kB/s 626 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 653
FFDC data, and other information to an FTP server in interactive mode on a dual-CP system: switch:admin> supportsave This command will collect RASLOG, TRACE, supportShow, core file, FFDC data and other support information and then transfer them to a FTP/SCP server or a USB device. This operation can - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 654
/art_saturn1-S6-200802171211-CONSOLE1.gz: 7.45 kB 217.17 kB/s Saving support information for switch:art_saturn1, module:SSAVELOG... ...ave_files/art_saturn1-S6-200802171212-sslog.ss.gz: 1.88 kB 53.35 kB/s SupportSave completed See Also supportShow 628 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 655
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. This command should only be run when requested by Brocade support personnel. Output generated by this command may vary by switch configuration and platform. Output may change without notice - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 656
command has the following operands: slotnumber/portnumber1-portnumber2 Specify the range of ports to display. If the slotnumber/portnumber parameter is omitted, all ports in the switch display in the per-port outputs. The slotnumber must be provided when specifying a range of ports on multi-bladed - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 657
os Disables the OS group commands. exception Disables the exception group commands. port Disables the port group commands. fabric Disables the fabric group commands. services Disables the service group commands. security Disables the security group commands. network Disables the network - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 658
os Enables the OS group commands. exception Enables the exception group commands. port Enables the port group commands. fabric Enables the fabric group commands. services Enables the service group commands. security Enables the security group commands. network Enables the network group - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 659
for details. Operands none Examples To display which groups of commands are enabled in the supportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 660
2 switchBeacon switchBeacon Sets switch beaconing mode on or off. Synopsis switchbeacon [mode] Description Use this command to enable or disable switch beaconing mode. Switch beaconing can be used to locate a failing unit. When beaconing mode is turned on, the port LEDs flash amber, left to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 661
by watching the front panel LEDs change to slow flashing yellow as each port is disabled. A persistently disabled switch can be temporarily enabled using the switchEnable command. A temporarily enabled switch remains disabled after a reboot. Notes Performance Monitoring cannot be added to any - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 662
. Synopsis switchcfgpersistentenable Description Use this command to persistently enable the switch. All Fibre Channel ports that passed the power-on self-test (POST) are enabled and come online if connected to a device, or remain offline if disconnected. The switch might need to be enabled if - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 663
Description Use this command to configure the speed of all the ports on a switch to a particular level. The configuration is saved in flash memory and persists across switch reboots or power cycles. If any port on the switch is not capable of the specified speed setting, an error message - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 664
Enables or disables trunking on all the ports of a switch. Synopsis switchcfgtrunk mode Description Use this command to enable or disable trunking on all the ports of a switch. Use portCfgTrunkPort to enable or disable trunking on a single port. When the command is executed to update the trunking - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 665
or before running many of the diagnostic tests. All commands that require the switch to be disabled send an error if invoked while the switch is enabled. Notes The switch does not need to be disabled before rebooting or powering off. As each port is disabled, the front panel LED changes to a slow - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 666
role, then this switch becomes a subordinate switch and accepts a domain ID from the principal. As each port is enabled, the front panel LED changes to green for online ports, black for disconnected ports, or yellow for uninitialized ports. Note The execution of this command is subject to Admin - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 667
2 switchName Displays or sets the switch name. Synopsis switchname [name] Description Use this command to display or set the switch name. All switches have a symbolic name that is primarily used for switch management. This name is shown in the Fabric OS CLI prompt, under each switch icon on the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 668
of the 24-bit port ID, which consists of domain, area number, and optional AL_PA. Area column is only displayed for non-slot based platforms. Index Index follows Area up to 255. Then it continues to the maximum port of the platform. Index identifies the port number relative to the switch. Index - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 669
ISCSI copper serial ID The speed of the port: 125 Mbps Port marked faulty. Port failed diagnostics. Locking to the reference signal. Running diagnostics. Connection not established (for virtual ports only). Port is up and running. Protocol support by GbE port. Ports support ISCSI. Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 670
as In_Sync when the port is the interswitch link (ISL) between a Brocade 48000 and a Brocade. If the ISL is between a Brocade 48000 and a Brocade 4100 or 200E, the disabled E_Port displays as No_Sync. On a Brocade 7600 switch, if the SAS image is not consistent with the FOS image, the message "SAS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 671
command has the following operands: -portcount Displays the number of ports on the switch. -iscsi Displays the number of ports on the iSCSI sessions associated with GbE ports in a switch. Examples To display the port count: switch:admin> switchshow -portcount ports= 64 To display GbE ports - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 672
Port F-Port VE-Port VE-Port VE-Port VE-Port VE-Port VE-Port VE-Port VE-Port To display a switch in Access Gateway mode: switch:admin> switchName: switchType: switchState: switchMode: switchWwn: switchBeacon: switchshow switch 34.0 Online Access Gateway Mode 10:00:00:05:1e:35:10:57 OFF Area Port - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 673
values, if there is one faulty port in a switch, then this contributor would set the overall switch status to MARGINAL. If two ports were faulty, then this contributor would set the overall switch status to DOWN. Note The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 674
** the policy parameter is NOT applicable to the switch. ** Simply hit the Return key. The minimum number (0..2) [1] Down Blade contributing to DOWN status: (0..8) [0] Down Blade contributing to MARGINAL status set has been changed switchStatusPolicyShow, switchStatusShow 648 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 675
for each contributor that trigger a status change in the switch. For example, if the FaultyPorts DOWN parameter is set to 3, and three ports fail in the switch, then the status of the switch changes to DOWN. Note The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 676
2 switchStatusPolicyShow Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow 650 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 677
ports. This command displays the overall switch status, and the status of the following contributors: • Power supplies • Temperatures • Fans • WWN servers (dual-CP systems only) • Standby CP (dual-CP systems only with HA enabled) • Blades (bladed systems only) • Flash • Marginal ports • Faulty ports - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 678
:user> switchstatusshow Switch Health Report Switch Name: switch IP address: 10.32.89.26 SwitchState: MARGINAL Duration: 80:12 Report time: 09/11/2006 05:39:28 PM Power supplies monitor Temperatures monitor Fans monitor Flash monitor Marginal ports monitor Faulty ports monitor Missing SFPs - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 679
has been operating. Synopsis switchuptime Description Use this command to display the current time and the amount of time that the switch has been operational. Operands none Examples To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins See Also none Fabric OS - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 680
Specifies the violation type as DCC. Notes This command can be executed on both active and standby CPs. This command does not support High Availability (HA). Examples To display DCC violations for a switch: switch:admin> switchviolation --dump -dcc Device WWN Port 22:00:00:04:cf:75:59:87 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 681
operand is optional; if omitted, the current facility is displayed. Examples To set the syslog facility to LOG_LOCAL1: switch:admin> syslogdfacility -l 1 Syslog facility changed to LOG_LOCAL1 See Also syslogdIpAdd, syslogdIpRemove, syslogdIpShow Fabric OS Command Reference 655 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 682
servers are supported. You can specify a syslogd server in one of two ways: • By IP address: The syslogdipadd command accepts IPv4 and IPv6 addresses. • By host name: The host must have a DNS entry and accept DNS requests. The DNS name service must be configured on the switch with dnsconfig before - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 683
.2.2.36 2. Add the DNS name server to the switch: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit Select an item: (1..4) [4] 2 Enter Domain Name: [] brocade.com Enter Name Server IP address in dot/colon - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 684
sent. IPv6 and IPv4 syslogd address configurations are supported. Note The execution of this command is subject to Admin Domain restrictions that may switch:admin> syslogdipremove 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpShow 658 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 685
and IPv6 addresses are supported. Operands none Examples To display all syslog daemon IP addresses configured on a switch: switch:admin> syslogdipshow syslog.1 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpRemove Fabric OS Command Reference 659 53-1000599 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 686
the active CP, standby CP, and any AP blades. After executing this command, manually power off the system. To reboot the system, manually turn the power switch on. Notes This command is not supported on the standby CP. The execution of this command is subject to Admin Domain restrictions that may - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 687
. ppc440gx System Halted To perform a system shutdown of the FR4-18i AP blade from the active CP: switch:admin> sysshutdown This command will shutdown the operating systems on your switch. You are required to power-cycle the switch in order to restore operation. Are you sure you want to shutdown the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 688
to run a comprehensive, system-wide test of all switches in a system. The command initiates a burn-in run on all switches within the current system. The optional -fru and -unit parameters allow you to focus the testing to a single blade in a multi-blade system. The run can be terminated by issuing - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 689
OS Message Reference for more information. To initiate a system verification test on all switches in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - number_of_runs - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 690
temperature sensors in a switch. For each sensor, this command displays the slot number (if applicable), the sensor state, and the temperature. The temperature readings are given in both Centigrade and Fahrenheit. Note Refer to the hardware reference manual for your switch to determine the normal - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 691
values are 1 to 99,999, or 0 to disable login timeouts. This operand is optional; if omitted, the command displays the current timeout value. Examples To set the idle timeout to 10 minutes: switch:admin> timeout 10 IDLE Timeout Changed to 10 minutes The modified IDLE Timeout will be in effect - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 692
, the path cost, and the number of hops from the local switch to the destination switch. - A summary of all ports that are routed through that path. 3. On a backbone fabric, the command displays details for remote domains only. Details for local translate domains are not displayed. 4. If there - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 693
the topology on a single switch: domain is local, details are not displayed. switch:user> topologyshow 1 domains in Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 2 15 0 1 2 3 4 5 6 7 8 9 11 2.000 Gbps 4000 % D Domain: Metric: Name: Path Count: 3 10500 fcr_xd_3_5 1 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 694
Metric: Name: Path Count: 160 500 fcr_fd_160 1 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 1 11 0 1 2 3 4 5 6 7 8 9 15 8.000 Gbps 1275 % D The command is executed from the backbone in a fabric with five switches. The fabric has five domains, but details are only shown for - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 695
See Also In Ports: Total Bandwidth: Bandwidth Demand: Flags: 23 24 33 38 39 8.000 Gbps 350 % D fcrXlateConfig, portRouteShow, uRouteShow topologyShow 2 Fabric OS Command Reference 669 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 696
-day-hour-minute-second) is the trace dump time. If a non-bladed system has an embedded BP, two trace dumps will be generated, a*.dmp file for the main switch and a *.tar.gz archive for the embedded BP. Operands This command has the following mutually exclusive operands: -S Displays dump status - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 697
Displays information on the track-changes commands. Synopsis trackchangeshelp Description Use this command to display information about the track-changes commands. Examples To display information on the track-changes commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 698
on • Track-changes off The output from the track-changes feature is dumped to the error log for the switch. Use errDump or errShow to view the error log. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to chapter 1, "Understanding Admin Domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 699
is enabled or disabled and if SNMP traps are generated. The output from the track-changes feature is dumped to the error log for the switch. Use the errDump command or errShow command to view the error log. Operands none Examples To display the status of the track-changes feature - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 700
is required. port2 Specify the area number of port 2. Use the switchShow command to view the area numbers for a port. This operand is required. Examples To debug a trunk connection: switch:admin> trunkdebug 43 44 Switch does not support trunking switch:admin> trunkdebug 62 63 port 62 and 63 are - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 701
by 10. The firmware automatically sets the minimum deskew value of the shortest ISL to 15. Master Displays whether this trunking port connection is the master port connection for the trunking group. Operands none Examples To display trunking information for a switch: switch:admin> trunkshow - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 702
:05:1e:37:12:13 64-> 16 10:00:00:05:1e:37:12:13 65-> 19 10:00:00:05:1e:37:12:13 4 deskew 17 MASTER 4 deskew 16 4 deskew 16 4 deskew 16 4 deskew 17 4 deskew 17 4 deskew 15 4 deskew 16 switch:admin> switchshow 48 4 0 013000 id N4 Online EX-Port (Trunk port, master is Slot 4 Port 1 ) 49 4 1 013100 id - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 703
(if specified) and broadcasts time service updates. All switches in the fabric maintain the current clock switch are propagated to all switches in the fabric. Use this command without parameters to display the active NTP server and the configured NTP server list. Specify the ipaddr operands to set - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 704
.123.123.123 Updating Clock Server configuration...done. switch:admin> tsclockserver 123.123.123.123 To configure multiple NTP servers: switch:admin> tsclockserver "12.134.125.24; 12.234.87.01" Updating Clock Server configuration...done. See Also date 678 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 705
minuteOffset] Description Use this command to display or set the system time zone. All switches maintain the current time zone . An incorrect time zone setup does not affect the switch operation in any way. System services started during the switch boot reflect a time zone change only at the next - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 706
Cayman Islands 28) Jamaica 45) United States 12) Chile 29) Martinique 46) Uruguay 13) Colombia 30) Mexico 47) Venezuela 14) Costa Rica 31) Montserrat 48) Virgin Islands (UK) 15) Cuba 32) Netherlands Antilles 49) Virgin Islands (US) 16) Dominica 33) Nicaragua 17) Dominican Republic 34 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 707
Time - Indiana - Pike County 12) Central Time - Michigan - Dickinson Time - south Idaho & east Oregon 16) Mountain Time - Navajo 17) Mountain Standard switch admin> tstimezone --old 2 switch admin> tsttimezone Time Zone Hour Offset: 2 Time Zone Minute Offset: 0 See Also date Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 708
value is 1. -ports itemlist Specifies a list of blade ports to test. By default, all the blade ports in the specified slot are tested. Refer to the itemList command help page for more information. Examples To execute this test: switch:admin> turboramtest -passcnt 2 -ports 2/0-2/63 Running Turbo - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 709
in minutes. The output format adjusts accordingly. Operands none Examples To display the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, 1.08, 1.08 See Also date, fastboot, reboot Fabric OS Command Reference 683 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 710
300, 4900, 5100, 5300, 7500, 7600, and DCX platforms. On the Brocade 48000, Static route configuration is not supported on Brocade directors set to chassis configuration option 5 by chassisConfig. The execution of this command is subject to Admin Domain restrictions that may be in place. Refer to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 711
domain for in_area might change to use a different output port, but only if dynamic load sharing (DLS) is set. If DLS is not set, the route remains as is, with its route attribute changed from static to dynamic. Note The execution of this command is subject to Admin Domain restrictions that may be - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 712
is received. Except for the cases in which you perform a port swap or enable extended-edge PID (PID Format 2) on a switch, the value is equal to the Area field displayed by the switchShow command. Refer to Fabric OS Administrator's Guide for more information regarding the extended-edge PID format - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 713
routing information of port 11 to domain 4 only: switch:admin> urouteshow 1/11, 4 Local Domain ID: 3 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 11 4 16 500 1 D 4,16 See Also portRouteShow, topologyShow, uRouteConfig, uRouteRemove Fabric OS Command Reference 687 53 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 714
device until it is enabled again. This command may fail if USB storage is busy doing a read/write operation. -r |--remove application area Removes data in a specified application storage space. Valid applications are: firmware, support, config, firmwarekey. A specified application must be followed - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 715
74% To remove an application area: switch:admin> usbstorage -r firmware FW_v6.0.0 To disable an attached USB device: switch:admin> usbstorage -d USB storage disabled supportSave, firmwareDownload, configUpload, configDownload, firmwareKeyupdate Fabric OS Command Reference 689 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 716
functions. Notes The userConfig command operates on the switch-local user database only, regardless of whether the switch is configured to use RADIUS authentication or not. The account database supports a maximum of 256 customer created accounts. 690 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 717
account database is no longer supported on switches running Fabric OS v6.0 or later. As a consequence, account recovery from backup as well as backup display option (former --show -b option) are no longer supported in Fabric OS v6.0 or later. The execution of this command is subject to Admin Domain - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 718
permissions of the account that executes this command. This operand is optional. If no or modified account. This command also prompts for an initial account from the switch. This command prompts for confirmation account that runs the userConfig --delete command. --addad --deletead Adds one or - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 719
range (1-5) or a list of AD_IDs separated by comma (1,2,3), or a combination of both (1-5,7). Displays command usage. Examples To add a new account: switch:admin> userconfig --add joe -r admin -d "Joe Smith" Setting initial password for joe Enter new password: Re-type new password: Account joe has - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 720
See Also To add AD 0 & 255 to bob's AD member list. Home AD is unchanged: switch:admin> userConfig --addad bob -a 0,AD255 To delete AD 128 from bob's AD member list. New home AD is set to 0: switch:admin> userConfig --deletead bob -a 128 -h 0 none 694 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 721
indicate the same role as old_username. Notes This command is not supported on all platforms. The execution of this command is subject to Admin Domain restrictions that may be "USERID" to "admin": switch:admin> userrename USERID admin See Also none Fabric OS Command Reference 695 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 722
information and build dates. The command output includes the following: Kernel The version of switch kernel operating system. Fabric OS The version of switch Fabric OS. Made on The build date of firmware running in switch. Flash The build date of firmware stored in flash proms. BootProm - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 723
wwn 2 wwn Displays or sets the World Wide Name (WWN) of the switch. Synopsis wwn [-sn | name] Description Use this command to display or change the WWN associated with a switch and to display the switch serial number. All switches have a numeric address that is the unique Fibre Channel address - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 724
2 wwn See Also To display the switch WWN and serial number: switch:admin:admin> wwn -sn WWN: 10:00:00:05:1e:01:23:e0 SN: RC030000089 switchShow 698 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 725
backbone fabric locks down the route within the backbone fabric based on EX_Ports and devices involved. TI zones over FCR is supported only on switches running Fabric OS v6.1.0 or later. Participating devices need to be LSAN Zoned to enforce TI. Fabric OS Command Reference 699 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 726
: A base zone " supported in fabrics involving switches running firmware versions preceding Fabric OS v6.0. However, the existence of a TI Zone in such a fabric is backward compatible and does not disrupt fabric operation in switches running earlier firmware versions. The current zone commands - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 727
The zone database used as input to this command is specified using mode. If the optional zone a zone. mode Specifies the zone database location. Supported mode flag values are: 0 Uses the zone to existing TI zones. The remove option removes port list members from existing zones. Removal of the - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 728
the zone will be activated. This operand is supported only with the --create and --add options Zone comes online again, the route is set up again and the switch generates another SCN/RSCN. f Enables failover . This command prompts for confirmation. --show [name] Displays zone name, port lists, - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 729
FCR to support FCR. Specify nonFCR if you do not wish to support FCR. based on members and the specified configuration. Use cdfgShow to display currently implemented RD zone by name. Examples 1. Specific zone operation commands switch:admin>zonecreate z10,a10 switch:admin>zonecreate a10, 1,2 switch - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 730
zone members that are not enforceable: switch:admin> zone --validate -f You are about to prune the zone configurations, based on zone --validate output. Do you want to prune the zone configurations (yes, y, no, n): [no] y 2. Traffic isolation zone commands: To create a traffic isolation zone with - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 731
Zone within a Backbone where a host, target1, and target4 communicate over VE_Ports consisting of FCR1's port number 4 and FCR2's port number 7: switch:admin>zone --create -t ti fcr_ti_zone> p "1,1; 2,1;host_PWWN; target1_PWWN; target4_PWWN; 1,4; 2,7" Fabric OS Command Reference 705 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 732
40:40:40:40:40:40:40 restartable noFCR This command creates the following zone objects: 4. RD zone "red_0917_10_10_10_10_10_10_10_10_20_20_20_20_20_20_20_20", with a restrictedly policy and no FCR support. 5. The base zone object, "red_______base". 6. The RD zone configuration, "r_e_d_i_r_c__fg". To - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 733
by semicolons. Valid values can be one or more of the following: A switch domain and port area or index number pair; for example, "2, 20". View the area or index numbers for ports using the switchShow command. • Node or port WWN. • Zone alias name. Examples To add aliases for three disk arrays - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 734
different zones. Zone names are limited to 64 characters. Spaces are ignored. "member" Specify switch 2, ports 12 and 14, and to the device with the World Wide Name "10:00:00:60:69:00:00:8a" (either node name or port name), at the port in the fabric to which it is connected. 708 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 735
a combination of port numbers and zone aliases: sw5:admin> zonecreate "Purple_zone", "1,0; loop1" sw5:admin> zonecreate "Blue_zone", "1,1; array1; 1,2; array2" sw5:admin> zonecreate "Green_zone", "1,0; loop1; 1,2; array2" zoneAdd, zoneDelete, zoneRemove, zoneShow Fabric OS Command Reference 709 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 736
For the change to become effective, enable the configuration with the cfgEnable command. Notes When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operands are required: "zonename" Specify the name of the zone to be deleted. Quotation - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 737
zoneHelp 2 zoneHelp Displays a description of zoning commands. Synopsis zonehelp Description Use this command to display short descriptions of zoning commands. Operands none Examples To display zone command help information: switch:admin> zonehelp aliadd alicreate alidelete aliremove - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 738
the change to become effective, enable the configuration with the cfgEnable command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operands are required: "objectName" The name of the object that you want to copy. Quotation - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 739
. For the change to become effective, enable the configuration with the cfgEnable command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operand: "objectName" The name of the object that you want to expunge - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 740
. For the change to become effective, enable the configuration must be enabled with the cfgEnable command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operands are required: "objectName" The name of the object you want to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 741
Use switchShow for a list of valid port area or index numbers. • A World Wide Name • A zone alias name Examples To remove "array2" from "Blue_zone": switch:admin> zoneremove "Blue_zone", "array2" See Also zoneAdd, zoneCreate, zoneDelete, zoneShow Fabric OS Command Reference 715 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 742
and those that match in the defined configuration are displayed. Notes When FCS policy is enabled, this command can be issued on any FCS switch in the fabric. Operands This command has the following operands: "pattern" A POSIX-style regular expression used to match zone configuration names. The - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 743
run from the primary FCS switch. Must be run from the primary FCS switch. Can be run on all FCS switches. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. This command can be run on all switches to view the current date - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 744
. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. 718 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 745
when logged in to the standby CP on a Brocade 48000 or DCX Backbone. The full set of commands for your user role is available on the active CP. Commands supported on the standby CP The following commands are supported when logged into the standby CP. TABLE 23 Commands supported on the standby CP - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 746
. (Linnux command. No FOS help page.) reboot Reboots the standby CP. setModem Enables or disables modem dial-in to a control processor (CP). Not supported on the Brocade DCX. supportSave Saves support information for RASLOG, TRACE, and supportShow. switchName Displays this switch's name - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 747
the following. If more than one AD type is listed for a command, the AD type is optio- specific. Display options may be allowed, but set options may be subject to Admin Domain restrictions. • SwitchMember = Allowed to execute only if the local switch is part of the current AD. • Allowed = Allowed to - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 748
types Refer to Table 1 for the RBAC and Admin Domain availability of all Fabric OS commands. TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin aaaConfig ad ag agShow aliAdd aliCreate aliDelete aliRemove aliShow aptPolicy auditCfg authUtil bannerSet - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 749
permissions and AD types A TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin cfgDisable O cfgEnable O cfgMcdtMode 0 cfgRemove O cfgSave O cfgSaveActiveToDefined O cfgShow O cfgSize O cfgTransAbort O cfgTransShow O chassisConfig - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 750
RBAC permissions and AD types TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin diagShow diagSkipTest diagStopBurnin distribute dlsReset dlsSet dlsShow dnsConfig enclosureShow errClear errDelimiterSet O OM OM OM O OM OM OM O OM OM OM - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 751
permissions and AD types A TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin fcpLogEnable fcpLogShow fcpProbeShow fcpRlsShow fcrBcastConfig fcrChipTest fcrcConfigure fcrFabricShow fcrlsanCount fcrlsanMatrix fcrPathTest fcrPhydevShow fcrProxyConfig - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 752
RBAC permissions and AD types TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin foscConfig fruReplace fspfShow fwAlarmsFilterSet fwAlarmsFilterShow fwClassInit fwConfigReload fwConfigure fwFruCfg fwHelp fwMailCfg fwPortDetailShow fwSamShow fwSet - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 753
permissions and AD types A TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin interfaceShow interOpMode O OM OM OM O OM OM OM iodDelayReset iodDelaySet iodDelayShow iodReset iodSet iodShow ipAddrSet ipAddrShow ipFilter iscsiCfg iscsiChipTest - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 754
AD types TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin miniCycle O OM OM OM msCapabilityShow O OM OM OM OM OM OM OM N OM N OM OM OM OM OM OM OM OM OM Basic Switch Admin O O O O O O O O O O O OM O O O O O O O O O N OM N O O O O O O O O O - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 755
permissions and AD types A TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin perfCfgClear O perfCfgRestore O perfCfgSave O perfDelEEMonitor O perfDelFilterMonitor O perfHelp O perfMonitorClear O perfMonitorShow O perfSetPortEEMask - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 756
permissions and AD types TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin portCfgPersistentEnable O OM OM OM portCfgQos portCfgShow portCfgSpeed portCfgTrunkPort portCfgvExport portCmd portDebug portDisable portEnable portErrShow portFlagsShow - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 757
RBAC permissions and AD types A TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin portStats64Show portStatsClear portStatsShow portSwap portSwapDisable portSwapEnable portSwapShow portTest portTestShow portTrunkArea portZoneShow powerOffListSet - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 758
permissions and AD types TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin sensorShow O setDbg O setModem O setVerbose O sfpShow O shellFlowControlDisable O shellFlowControlEnable O slotPowerOff O slotPowerOn O slotShow O slTest - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 759
permissions and AD types A TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin switchStatusPolicyShow O switchStatusShow O switchUptime O switchViolation O syslogdFacility O syslogdIpAdd O syslogdIpRemove O syslogdIpShow O sysShutdown - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 760
RBAC permissions and AD types TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin wwn O OM OM OM zone zoneAdd zoneCreate zoneDelete zoneHelp zoneObjectCopy zoneObjectExpunge zoneObjectRename zoneRemove zoneShow O OM O O O OM O O O OM - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 761
beacon and switchBeacon, 634 BIST test, 162 bladeDisable, 48 Bloom-based platform, 456, 505 Brocade 200E switch, 644 Brocade 4100 switch, 140, 141, 143, 146, 149, 151, 154, 155, 156, 157, 160, 162, 164, 166, 173, 644 Brocade 48000 director, 644 Brocade 4900 switch, 140, 141, 143, 146, 149, 151, 154 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 762
112 DID used, 426, 427 DLS, see dynamic load sharing DMA test, 162 domain name service, 119 dual CP system active CP and supportFTP, 625 dynamic load sharing, 37, 116, 179, 180, 181, 184, 185, 334, 570, 642 FC4-16 port blade, 603 FC4-32 port blade, 603 736 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 763
Channel Extended Link Service, 152, 499, 539 Fibre Channel Protocol, 158, 159 FICON, 98, 191, 192, 194, 196, 197, 200, 202, 459, 608, 609, 629, 631, 632, 633, 644 FICON-MIB, 608, 609 FICON-TRAP, 609 field replaceable unit, see FRU filter-based monitor, 395, 402, 403, 404, 408 firmware download, 206 - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 764
port type, 198, 199, 200, 202, 424, 483, 539, 541 portAlpaShow, 423 portCamShow, 426 portCfgEXPort, 446, 473 portLogShow, 499 portswap feature, 536, 537, 538 POST, 49, 53, 103, 104, 106, 107, 108, 111, 143, 604, 636, 640 disabling, 103 power-on self-test, see POST 738 Fabric OS Command Reference - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 765
341, 342, 343, 505 serial port, 127, 320, 333, switch speed, 637 switchBeacon, 634 switchShow, 644 SW-TRAP, 609 syslog, 122, 655, 656, 659 sysShutdown active CP, 660 system services, 95, 679 system time zone, 679 systemGroupConfiguration parameters, 609 systemVerification, 662, 663 Fabric OS Command - HP StorageWorks 4/16 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 766
user port, 318, 424, 484, 515 V VC_RDY, 452 VEX_Port, 472, 473, 474 virtual channel settings, 92, 93 W WAN_TOV, 81, 91, 92 Web Tools, 268, 406 Z zone, 699 zone configuration and cfgActvShow, 55 and zone, 699 clearing, 57 inaliShow, 36 zoneObjectRename, 714 740 Fabric OS Command Reference 53
53-1000599-02
12 March 2008
Fabric OS
Command Reference Manual
Supporting Fabric OS 6.1.0