HP StorageWorks 4/32 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 434
HAM-1005, Software Fault:Kernel Panic
View all HP StorageWorks 4/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 434 highlights
43 HAM-1005 • Fastboot • Giveup Master:SYSM • CP Faulty:SYSM • FirmwareDownload • ConfigDownload:MS • ChangeWWN:EM • Reboot:WebTool • Fastboot:WebTool • Software Fault:Software Watchdog • Software Fault:Kernel Panic • Software Fault:ASSERT • Reboot:SNMP • Fastboot:SNMP • Reboot • Chassis Config • Reboot:API • Reboot:HAM • EMFault:EM Recommended Check the error log on both CPs for additional messages that might indicate the reason for the Action reboot. Severity INFO HAM-1005 Message , [HAM-1005], , SLOT cp-slot-number | CHASSIS, INFO, , HeartBeat Miss reached threshold. Probable Cause Indicates that either the active control processor (CP) EMAC controller or the standby CP is down. The active CP will run a diagnostic test on the EMAC controller and will wait for the standby CP to reset it if it is down. Recommended No action is required. Action Severity INFO HAM-1006 Message Probable Cause , [HAM-1006], , SLOT cp-slpt-number | FFDC | CHASSIS, FFDC, CRITICAL, ,EMAC controller for Active CP is BAD. Indicates that the local EMAC controller on the active control processor (CP) is BAD as determined by the diagnostic test run by the HAM module. 364 Fabric OS Message Reference 53-1001338-01