HP StorageWorks 4/64 Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000
HP StorageWorks 4/64 - SAN Switch Manual
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/64 manual content summary:
- HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 1
53-1000599-01 19 Oct 2007 Fabric OS Command Reference Manual Supporting Fabric OS v6.0.0 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 2
SAN Health, and Tapestry are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. FICON is a registered trademark of IBM Corporation in the U.S. and other countries. All other brands, products, or service names are or may be trademarks or service Brocade - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 3
brocade.com Document History The table below lists all versions of the Fabric OS Command Reference. Document Title Publication Number Manual Fabric OS Command Reference 53-0000519-08 Rev. A Manual Fabric OS Command Reference 53-0000519-09 Manual Fabric OS Command Reference 53-0000519-10 Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 4
Document Title Publication Number Fabric OS Command Reference Manual Fabric OS Command Reference Manual Fabric OS Command Reference Manual Fabric OS Command Reference Manual 53-0000519-12 53-1000240-01 53-1000436-01 53-1000599-01 Summary of Changes Publication Date July 2005 September 2006 15 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 5
Document Is Organized xvii Supported Hardware and Software xvii 1 Using Fabric OS Commands Understanding Role-Based Access Control 1 Understanding Admin Domain Restrictions ag 19 agshow 28 aliAdd 30 aliCreate 31 aliDelete 32 aliRemove 33 aliShow 34 aptPolicy 35 auditCfg 37 authUtil - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 6
bladeEnable 46 burninErrClear 48 burninErrShow 49 burninLevel 50 burninStatus 51 cfgActvShow 52 cfgAdd 53 cfgClear 54 cfgCreate 55 cfgDelete 56 cfgDisable 57 cfgEnable 58 cfgMcdtmode 59 cfgRemove 60 cfgSave - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 7
Fabric OS Command Reference 53-1000599-01 diagEnablePost 101 diagEnv 102 diagFailLimit 104 diagHelp 105 diagPost 106 diagRetry 107 diagSetBurnin 108 diagSetCycle 109 diagShow 110 diagSkipTests 111 diagStatus 112 diagStopBurnin 113 dbgShow 114 distribute 115 dlsReset 117 dlsSet 118 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 8
fanEnable 145 fanShow 146 fastboot 147 fastwritecfg 148 fazoneAdd 150 fazoneCreate 151 fazoneDelete 153 fazoneRemove 154 fazoneShow 155 fcipChipTest 156 fcipPathTest 158 fcLunQuery 160 fcPing 161 fcpLogClear 163 fcpLogDisable 164 fcpLogEnable 165 fcpLogShow 166 fcpProbeShow 167 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 9
233 fwFruCfg 238 fwHelp 239 fwMailCfg 240 fwPortDetailShow 242 fwSamShow 245 fwSet 246 fwSetToCustom 247 fwSetToDefault 248 fwShow 249 h 252 haDisable 253 haDump 254 haEnable 256 haFailover 257 haShow 258 haSyncStart 260 haSyncStop 261 ix - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 10
help 262 historyLastShow 263 historyMode 264 historyShow 265 httpCfgShow 267 i 268 ifModeSet 270 ifModeShow 272 interfaceShow 273 interopMode 277 iodReset 280 iodSet 281 iodShow 282 ipAddrSet 283 ipAddrShow 286 ipfilter 287 iscsiCfg 290 iscsiChipTest 298 iscsiHelp 299 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 11
Fabric OS Command Reference 53-1000599-01 lsDbShow 327 memShow 330 miniCycle 331 minisPropShow 336 msCapabilityShow 337 msConfigure 338 msPlatShow 340 msPlatShowDBCB 341 msPlClearDB 342 msPlMgmtActivate 343 msPlMgmtDeactivate 344 msTdDisable 345 msTdEnable 346 msTdReadConfig 347 myId - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 12
perfClearAlpaCrc 392 perfClearFilterMonitor 393 perfDelEEMonitor 394 perfDelFilterMonitor 395 perfHelp 396 perfMonitorClear 397 perfMonitorShow 399 perfSetPortEEMask 403 perfShowAlpaCrc 405 perfShowEEMonitor 406 PerfTTmon 408 pkiCreate 411 pkiRemove 412 pkiShow 413 policy 414 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 13
Fabric OS Command Reference 53-1000599-01 portDebug 471 portDisable 472 portEnable 473 portErrShow 474 portFlagsShow 475 portLedTest 476 portLogClear 477 portLogConfigShow 478 portLogDisable 479 portLogDump 480 portLogDumpPort 481 portLogEnable 482 portLogEventShow 483 portLoginShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 14
powerOffListSet 535 powerOffListShow 537 psShow 538 reboot 539 routeHelp 540 secActiveSize 541 secAuthSecret 542 secCertUtil 544 secDefineSize 547 secGlobalShow 548 secHelp 550 secPolicyAbort 551 secPolicyActivate 552 secPolicyAdd 553 secPolicyCreate 555 secPolicyDelete 558 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 15
Fabric OS Command Reference 53-1000599-01 snmpConfig 591 spinFab 598 statsClear 601 stopPortTest 602 supportFfdc 603 supportFtp 604 supportSave 606 supportShow 610 supportShowCfgDisable 615 supportShowCfgEnable 616 supportShowCfgShow 617 switchBeacon 618 switchCfgPersistentDisable 619 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 16
690 zoneObjectExpunge 691 zoneObjectRename 692 zoneRemove 693 zoneShow 694 Primary FCS Commands Primary FCS Commands 695 Control Processor Commands Commands Supported on the Standby CP 697 Command Availability Command Validation Checks 699 Command RBAC Permissions and AD Types 700 xvi - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 17
is a command reference manual written to help system administrators and technicians operate, maintain, and troubleshoot Brocade storage area network (SAN) products. "About This Document" contains the following sections: • "How This Document Is Organized," next • "Supported Hardware and Software" on - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 18
• Brocade 4018switch • Brocade 4020 switch • Brocade 4024 switch • Brocade 4100 switch • Brocade 4900 switch • Brocade 5000 switch • Brocade 7500 switch • Brocade AP 7600 switch • Brocade 24000 director • Brocade 48000 director • Brocade DCX Data Center Backbone director Procedures or parts of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 19
bug fixes, general edits, and hardware updates. NOTE FOS v6.0.0. supports the TCP/IP netstat command. Use this command to show network sockets, routing tables, interfaces, masquerade connections, or multicast memberships. By default, netstat lists open sockets. For a list of all netstat options, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 20
and each has different behavior when invoked. The pages have been removed from this manual. Note that some of the corresponding manpages have not been updated to reflect the unsupported status of these commands. PLATFORM-BASED COMMANDS These commands will be blocked from running on the new 4G, 8G - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 21
BASED COMMANDS These commands are still allowed to run on Brocade 48000 and DCX platforms in order to maintain consistency across mixed blade the narrative portions of this guide are presented in mixed lettercase: . If there are exceptions, this manual specifically notes those cases in which - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 22
, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards these conditions or situations. Key terms For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 23
at no cost for a user ID and password. For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon.com For additional Brocade documentation, visit the Brocade SAN Info Center and click the Resource - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 24
-18i blade in the Brocade 48000) NPIV - N-port ID Virtualization, allowing up to 256 virtual addresses per physical port NOTE For more information about licensed features refer to the Fabric OS Administrator's Guide. Getting Technical Help Contact your switch support supplier for hardware, firmware - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 25
or fabric behavior immediately • following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial console and Telnet session logs • syslog message logs 2. Switch Serial Number The switch serial number and corresponding bar code are - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 26
Provide the title and version number and as much detail as possible about your issue, including the topic heading and page number and your suggestions for improvement. xxvi Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 27
Fabric OS Commands Chapter 1 This chapter explains how to manage a Brocade SAN and Brocade switches and directors using the Fabric OS command line interface (CLI). The following topics discussed: • "Understanding Role-Based Access Control" on page 1 • "Understanding Admin Domain Restrictions" on - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 28
issued from a sectelnet or SSH session, as indicated in the command description in this manual. Access is controlled by a switch-level password for each access level. The commands available through the CLI are based on the user's login role and the license keys used to unlock certain features. The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 29
of its syntax, a description of command use, and a set of examples. The same information can be accessed by issuing help command.on a Brocade switch or director. This command displays the help page (also called man page) for the specified command. For example, to display the help or man page for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 30
1 Using the Command Line Interface 4 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 31
manual for specific details. Configuration changes are persistently saved and take effect with the next AAA request. The configuration applies to all switch instances in a platform supporting multiple switch domains. Customers can use centralized RADIUS servers to manage AAA services for a switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 32
as either RADIUS or LDAP. This operand is required. -p port Specifies the RADIUS or LDAP server port number. Supported range is 1 to 65535. The default port is 1812 for RADIUS authentication. The default port is 389 for LDAP authentication. This operand is optional. If no port is specified, the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 33
services. Services must be enclosed in quotation marks. The following AAA services and service pairs are valid: "local" Default setting. Authenticates the user against the local database only. If the password primary AAA service and the switch-local database as the secondary AAA service.When " - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 34
conf radius 1 To change the configuration for RADIUS server 192.168.233.48: switch:admin> aaaconfig --change 192.168.233.48 -conf ldap -p 3002 -s newsecret -t 1 To replace the AAA service with backup option: switch:admin> aaaconfig --authspec "ldap;local" -backup See Also none 8 Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 35
information. Before creating Admin Domains, the default zone mode should be set to "No Access" mode. Refer to defZone for more information. To set the default zone mode to "No Access": switch:admin> ad --select AD0 switch:admin> defzone --noaccess switch:admin> cfgsave Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 36
auto-assigning Admin Domain names to Admin Domains created with an Admin Domain number) and can be assigned to the corresponding Admin Domain alone. Using ad member types. Benefits include: • Grants port control and zoning on the switch port and the devices attached to that port. • PI can be - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 37
switch list with a semicolon (;). Specify the switch in one of the following formats: Switch WWN Domain ID Any switch member specified using Domain ID format will be converted into a switch WWN based . AD0 is always in an activated state. By default, after the Admin Domain is enabled, the devices - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 38
--apply or ad --save. --apply Saves the current transaction buffer contents to the defined configuration and enforces the defined configuration on all switches in the fabric. ad --apply prompts for confirmation. --clear Deletes all ADs and clears AD0's explicit members. This command fails if AD1 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 39
name does not correspond to ad_id's AD number. The rename operation remains in the transaction buffer until you issue ad --apply or ad --save. --save Saves the outstanding Admin Domain transaction to the defined configuration in all the switches in the fabric. The saved Admin Domain definition - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 40
running pre-v3.2 Fabric OS. This is because pre-v3.2 Fabric OS does not support Exchange Service Support (ESS), and therefore the Name Server cannot get the correct port range of such switches. --transabort Aborts the transaction buffer. ad --transabort prompts for confirmation before aborting the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 41
a user-assigned Admin Domain name to a reserved Admin Domain name (this operation fails if AD_test's AD number is not 200): switch:admin> ad--rename AD_test AD200 To remove the device 100,5 and 1,3 from AD1: switch:admin> ad --remove "AD1", -d "100,5; 1,3; 21:00:00:e0:8b:05:4d:05" To remove the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 42
2 ad 16 To select a new Admin Domain context by specifying the AD number: switch:admin> ad --select 12 To display all ADs: switch:admin> ad --show Current AD: 255 : AD255 Transaction buffer configuration no configuration Defined configuration AD: 1 : AD1 Active Device WWN members: Switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 43
; 10:00:00:60:69:00:02:53; To display the Admin Domain effective configuration information: switch:admin> ad --show -m 2 Current AD: 255 : AD255 Effective configuration AD: 1 : AD1 Active Device WWN members: Switch port members: Switch WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 44
the AD transaction (yes, y, no, n): [no] y See Also To display the current Admin Domain transaction: switch:admin> ad --transshow Current transaction token is 26816 It is abortable switch:admin> ad --transshow There is no outstanding zoning transaction cfgSave, cfgTransShow, defZone, logout 18 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 45
as config keys. Use portCfgnPort command to set a port as N_Port. Notes AG is supported only on selected Brocade hardware platforms. Refer to the Fabric OS Administrator's Guide for Hardware support and AG configuration procedures. Operands The command takes as input an action and its associated - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 46
The port grouping feature supports specifying a set of N_Ports to be included in the Port Group (PG) Policy. The factory default PG is "pg0", be separated by semicolon. Maximum numbers of ports allowed in a port group is MAX_PORT. Port Group ID must not exceed 64 characters. --pgadd pgid 'N_Port1 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 47
ag 2 --pgremove pgid Deletes the specified. the port group. --failoverenable N_Port Enables the failover policy for a given N_Port. When failover policy is enabled for a given N_port, F_ports behave as follows: • If only primary F_Port to N_Port mapping is in place, all currently mapped F_Ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 48
and 12: switch:admin> ag --show Name : switch_ST1 NodeName : 10:00:00:05:1e:35:9b:e7 Number of Ports : 16 IP Address(es) : 10.115.74.53 Firmware Version : v6 0 10.32.74.109 4;5;6; 1 0x6d0b00 20:0b:00:05:1e:37:11:aa 0 1 10.32.74.109 7;8;9; 2 0x6d0c00 20:0c:00:05:1e:37:11:aa 1 0 10.32.74.109 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 49
configupload. Do you want to continue? (yes, y, no, n): [no] y 5. To disable auto policy when switch is disabled: switch:admin> ag --policydisable auto Default factory settings will be restored. Default mappings will come into effect. Please save the current configuration using configupload. Do you - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 50
- PG_ID is the Port Group ID and PG_Name is the Port Group Name. 2. To clear all F_Ports mapped to the configured primary N_Port 0: switch:admin> ag --mapset 0 "" F_Port to N_Port mapping has been updated successfully 3. To add F_Ports 4 and 6 to N_Port 0 (observe that Port 0 has no configured - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 51
:admin> ag --failovershow 0 Failover on N_Port 17 is not supported switch:admin> ag --failbackdisable 2 Failback policy is disabled for port 2 admin> ag --failbackshow 2 Failback on N_Port 17 is not supported switch:admin> ag --failbackenable 2 Failback policy is enabled for port 2 3. To display - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 52
2 Failback on N_Port 2 is supported Port Group commands: 1. To display Port Group information: switch:admin> ag --pgshow PG_ID N_Ports PG_Name 0 1;3 pg0 2 0;2 SecondFabric 2. To create a port group "FirstFabric" that includes N_Ports 1and 3: switch:admin> ag --pgcreate - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 53
3 Preferred N_Port is deleted successfully for the F_Port[s] See Also 3. To set secondary port mapping for F_Ports 7, 8 and 9: switch:admin> ag --prefset "7;8;9" 3 Preferred N_Port is set successfully for the F_Port[s] portCfgNPort, portCfgNPIVPort Fabric OS Command Reference 27 53-1000599 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 54
10:00:00:00:c9:3f:7c:b9 To display the locally registered Access Gateways: switch:admin> agshow --local Worldwide Name Ports Enet IP Addr Firmware Local/Remote Name 10:00:00:05:1e:04:06:ae 24 10.32.173.64 v6.0.0 local L5D2_B14_4024_1 28 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 55
all Access Gateways attached to the fabric: switch:admin> agshow Worldwide Name Ports Enet IP Addr Firmware Local/Remote Name 10:00:00:05:1e:02:b7:2c 16 10.32.173.62 v6.0.0 remote L5D2_B10_4016_1 10:00:00:05:1e:04:06:ae 24 10.32.173.64 v6.0.0 local L5D2_B14_4024_1 10:00:00:05 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 56
a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands the following methods: • A switch domain and port area number pair. For ports using the switchShow command, view the area numbers. • WWN • QuickLoop AL_PAs - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 57
or more of the following methods: • A switch domain and port area number pair. View the area numbers for ports using the switchShow command. • WWN • QuickLoop AL_PAs Examples To create a zone alias: switch:admin> alicreate "array1", "2,32; 2,33; 2,34" switch:admin> alicreate "array2", "21:00:00 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 58
requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This zone alias array2: switch:admin> alidelete "array2" See Also aliAdd, aliCreate, aliRemove, aliShow 32 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 59
a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands of the following methods: • A switch domain and port area number pair. For ports using the switchShow command, view the area numbers. • WWN • QuickLoop AL_PAs This - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 60
specify 1 to display the contents of the nonvolatile memory. The default value is 0. If no parameters are specified, all zone configuration a description of this display. Examples To display all zone aliases beginning with "arr": switch:admin> alishow "arr*" alias: array1 21:00:00:20:37:0c:76:8c - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 61
when there is little or no oversubscription of the ISLs. Note that static routes are supported only with this policy. 3 Exchange-based routing policy (default). With this policy, the path chosen for an ingress frame is based on: • Ingress port on which the frame was received • FC address of the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 62
based policy (3). The following policies are supported: AP Shared Link Policy (default). AP Dedicated Link Policy. This policy will dedicate some links to the ingress traffic and some links to the egress traffic. Examples To change the current APT policy: switch:admin> switchdisable switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 63
be disabled by the --disable option. Based on the configuration, certain classes are 1-ZONE, 2-SECURITY, 3-CONFIGURATION, 4-FIRMWARE and 5-FABRIC filters. The execution switch:admin> auditcfg --class 2,3 Audit filter is configured. switch:admin> auditcfg --disable Audit filter is disabled. switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 64
set both FCAP and DH-CHAP, which is the default setting. When authentication is set to "all", Guide for details on FIPS configuration. --policy Sets the Switch authentication policy or Device authentication policy. The following sub-operands are supported: -sw on|off|active|passive set switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 65
, but the port will not be disabled if the connecting switch does not support authentication or the authentication policy is turned off. passive (default) Sets the authentication policy to passive mode. The switch does not initiate authentication but participates in authentication if the connecting - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 66
Also Authentication is set to dhchap. To set both protocols in order of FCAP and then DH-CHAP: switch:admin> authutil --set -a all Authentication is set to fcap,dhchap. To set DH group 3: switch:admin> authutil --set -g 3 DH Group was set to 3. To set all DH groups to be specified in auth - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 67
enter the banner text using the banner operand, the valid length is 116 characters. Examples To set a new banner for a switch: switch:admin> bannerset "My banner" switch:admin> bannerSet Please input context of security banner (press "." RETURN at the beginning of a newline to finish input): Do - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 68
is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also bannerSet 42 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 69
group (always 256) Member Ports 32, 64, and so on. The output from this command varies, depending on switch switch with 128 ports, the member ports consist of ports 7, 13, 42, 84, 85, and 86. The final Member Ports bit set represents the embedded port (frames sent to be handled by firmware - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 70
; if omitted, the current mode of blade beaconing for the specified slot is displayed. Examples To enable beaconing on slot 2, display the beaconing mode, then disable it: switch:admin> bladebeacon 2 1 switch:admin> bladebeacon 2 value = 1 switch:admin> bladebeacon 2 0 See Also switchShow 44 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 71
this blade, the remaining switches reconfigure, and this switch will configure based on the other blade ports. The blade must be disabled before making configuration changes or before running many of the diagnostic tests. The blade does not need to be disabled before rebooting or powering off - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 72
A blade cannot be disabled or enabled when the switch is disabled or when the blade itself is faulted, powered off number to be enabled. Examples To display the slot status, enable the user ports in slot 4, and verify the setting: switch:admin> slotshow Slot Blade Type ID Status 1 SW BLADE - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 73
See Also 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT bladeDisable, portDisable, portEnable, switchShow bladeEnable 2 Fabric OS Command Reference 47 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 74
may be in place. Operands The operand is a follows: slotnumber A nonzero value that specifies the slot number from which to clear burn-in errors. Examples To clear burn-in errors from slot 2. switch:admin> burninerrclear 2 See Also burninErrShow 48 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 75
burn-in. Operands The operand is as follows: slotnumber A nonzero value that specifies the slot number from which to display burn-in errors. Examples To display burn-in errors from slot 2: switch:admin> burninerrshow 2 See Also burninErrClear Fabric OS Command Reference 49 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 76
performs burn-in testing in place of the power-on self-test (POST) phase II each time a switch blade is powered on. The mode becomes active as soon as the errors prior to returning a board for service. For multi-bladed products, this is the independent blade, and for fixed-port-count products, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 77
the burn-in status of each blade in the system. The output contains the slot, state, current run number, current command in the run all slots are displayed. Examples To display the burn-in status for all slots: switch:admin> burninstatus Slot State Status Run 1 ABORT PASS 3 2 ABORT PASS 3 3 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 78
based on this configuration. The effective configuration is built when a specified zone configuration is enabled. This command requires a Brocade Advanced Zoning license. Operands none Examples To display the effective zone configuration information: switch:admin> cfgactvshow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 79
configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "cfgName" Specify a name for the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 80
access mode is "No Access", then this command re-creates the default zoning objects. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands none Examples To clear all zones and then clear - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 81
name must begin with a letter that can be followed by any number of letters, numbers, and underscores. Names are case sensitive: for example, "Cfg_1" requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 82
configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operand: "cfgName" Specify a name for the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 83
aborted. A message is displayed on the other switches to indicate the aborting of the transaction. If the default zone access mode is "No Access", then this command becomes cfgEnable "d_efault_Cfg". See defZone. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 84
for a description of defined and effective configurations. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operand: "cfgName" Specify the name of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 85
default zoning on one switch in the fabric will enable or disable the specific feature fabric wide, meaning that the feature will be disabled or disabled on all switches in the fabric. This command cannot be executed unless the Brocade switch/director no zone merge as part of the E_Port coming - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 86
configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "cfgName" Specify a name for the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 87
to nonvolatile memory in all switches in the fabric. The saved configuration is automatically reloaded by the switch on power on and, if a switch is automatically aborted. A message is displayed on the other switches to indicate the aborting of the transaction. Notes This command requires a Brocade - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 88
executed unless the Brocade switch/director is in switch:admin> cfgShow Default Zone: OFF Safe Zone: OFF Defined configuration: cfg: switch set switch1; sqitch2; switch3; switch4 zone: switch1 dd:dd:dd:dd:aa:aa:aa:aa; bb:bb:bb:cc:cc:cd:dd:dd zone: switch2 23:34:87:23:50:72:35:07; 12,64 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 89
an initiator sees in the fabric are based on this configuration. The effective configuration error checking has been completed successfully. When default zoning is enabled with "No Access" mode Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued on any FCS switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 90
default value is 0. This operand is optional. Examples To display all zone configurations that start with "Test": switch all zone configuration information: switch:admin> cfgshow Defined configuration: 0c:71:df To display only configuration names: switch:admin> cfgshow "*" cfg: USA1 Blue_zone cfg: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 91
to a message header that is propagated with the zone configuration to all switches in the fabric. Committed size is the size of the defined configuration currently a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 92
before the transaction was started. If a transaction is open on a different switch in the fabric when this command is run, the transaction on the other switch remains open and unaffected. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 93
internal zoning transaction. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can FCS switch. Operands none Examples To display the current transaction: switch:admin> cfgtransshow There is no outstanding zone transactions switch:admin> - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 94
on this platform. Brocade 48000 directors support only options 1 and 5. 1 One 128-port switch (blade ID 4, 17 on slots 1 - 4 and 7 - 10; blade ID 5, 16 on slots 5 - 6) 2 Two 64-port switches (blade ID 4 on slots 1 - 4 and 7 - 10; blade ID 5 on slots 5 - 6) 5 One 384-port switch (Blade ID 17, 18 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 95
on a Brocade 48000 director and to change the option: switch:admin> chassisconfig Current Option: 5 All Supported Options (With Blade ID 5 on slots 5-6 Option 1: One 128-port switch (Blade ID 4, 17 on slots 1-4, 7-10, Blade ID 5, 16 on slots 5-6) Option 5: One 384-port switches (Blade ID's 17 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 96
Use this command to display or change the name associated with the chassis. In dual-domain systems, there are up to two logical switches associated with a single chassis. Operands This command has the following operand: name Specify a new name for the chassis, optionally in quotation marks - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 97
, in hexadecimal. 2 Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor), WWN (World Wide Name), or UNKNOWN. Object number: Slot nn (for blades), Unit nn (for everything else). If the FRU is part of an assembly, a brief description, in parenthesis, displays - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 98
: Revision Num: 1 -180 60-0001532-03 1013456800 Day: 12 Month: 6 Year: 2001 Day: 15 Month: 7 Year: 2001 28 days 16 days 555-374757 234-294-12345 2734658 A.00 CP BLADE Slot: 6 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: ID - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 99
part of supportSave as the CH file. It is also saved persistently to compact flash if the goes in panic mode. The maximum number of saved entries for this command is 512. Operands None Examples To display the command history on a switch: switch:admin> clihistory Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 100
passwords (includes all user config and all built-in accounts) • Switch PID format • Ethernet Link Mode Refer to the configure command for more information on default or modify the existing ones. When issuing configDefault on the Brocade 7500, it persistently disables the ports. The execution of this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 101
of FOS that does not support IPv6. The first form of password should be provided on the command line. Instead, SCP will prompt for the password if necessary. The SSH service Guide for details regarding upload and download behavior The download might fail for some of the following reasons: • The switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 102
is only accepted if the boot.mac parameter matches the license ID (WWN) of the switch performing the download; otherwise, it is ignored. The download process is additive. The lines read (SCP). If no protocol is specified, it will default to FTP. 76 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 103
for example, "citadel" or "192.168.1.48". The configuration file is downloaded from this host the FTP server is running on Windows hosts. "passwd" Password for login when using the FTP protocol. -local Download be manually edited before being downloaded, either to the same or another switch. Such - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 104
2 configDownload configDownload complete: All config parameters are downloaded See Also configDefault, configList, configShow, configUpload, configure, configRemove, configRemoveAll 78 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 105
a list of configuration files stored on the local chassis: switch:admin> configlist -local config.txt config2.txt next_cfg.txt 25679 25679 20977 2007 Jan 02 15:16 2007 Jan 06 15:16 2007 Jan 18 15:16 See Also configDownload, configUpload, configShow, configRemove Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 106
file option is omitted, the command will prompt the user to specify a file name. Examples To remove a configuration file from the local chassis: switch:admin> configremove -local first_config.txt switch:admin> To remove a configuration file from an attached USB device without specifying a filename - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 107
pattern. Use of wildcards and other common regular expression operators is not supported. Some configuration settings will not display when filtered. If in doubt, the local configuration file: 1. List the file: switch:admin> configlist -local config.txt 92067 2007 Aug 07 03:59 2. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 108
:b0:db boot.device:eth0 boot.gateway.ipa:10.33.32.1 [LicensesDB] 6122B8EE0FBB440F46E124E97B16277D6122B8EE0FBB440F0073B7A57B16277D6F61 [DMM_WWN] [Licenses] [Chassis Configuration] truncated] 3. Filter the configuration file display output: switch:admin> configshow -local config.txt -pattern "passwdcfg - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 109
occur. The configUpload command supports DNS names, IPv4, and password should be provided on the command line. Instead, SCP will prompt for the password if necessary. The SSH service , and on chassis-based systems, to both Active host name is not known to the switch. • The host IP address cannot - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 110
as a number of sections switch boot parameters, also known as the switch's identity. It has variables such as the switch 's Guide for default to FTP. "host" A host name or IP address in quotation marks, for example, "citadel" or "192.168.1.48 hosts. "passwd" The password for login when using - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 111
interactive mode. Once a configuration file has been uploaded to an external system, it must NOT be manually edited before being downloaded, either to the same or another switch. Such an operation will bypass sanity checks for some configuration datapoints, resulting in unpredictable behavior. The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 112
Services Settings • Portlog Events Enable/Disable Settings • Secure Socket Layer (SSL) attributes • Remote Procedure Call Daemon (RPCD) attributes • cfgload attributes • Webtools attributes • System settings Notes. To access all parameters controlled by this command, you must disable the switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 113
1 10000 2000 0 7 2112 0 0 0 0 0 16 0 varies E_D_TOV * 2 to 120000 1000 to R_A_TOV / 2 0 to R_A_TOV / 4 7 to 19 256 to 2112 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 1 to 27 0 or 1 Fabric setting fields are defined as follows: Domain The domain number uniquely identifies a switch in a fabric. This value - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 114
By default, the switch can send Class F frames. When this option is turned on, Class F traffic is converted to Class 2 traffic before being transmitted. Per-frame Route Priority In addition to the eight virtual channels used in frame routing priority, support is also available for per-frame-based - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 115
F_Port Login Parameters (* = multiplication symbol) Field Type Default Range Maximum logins per switch Number 16 t* the max 1 to 126 * the number of ports max number of ports Maximum logins per port Number 126 1 to 255 Logins per second: Number 0 0 to 100 Login stage interval (milli - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 116
in Table 6 . TABLE 6 RSCN Transmission Modes Field End-device RSCN Transmission Mode Domain RSCN to End-device for switch IP address or name change Type number number Default 1 0 Range 0 to 2 0 to 1 End-device RSCN Transmission Mode values are as follows: 0 RSCN only contains single PID - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 117
. System Services Settings The following table defines settings affecting System Services. TABLE 8 Disable RLS probing Field Type Default Range Disable validation for firmware Basic User Enabled Perform License Checking and Warning Allow Fabric Event Collection string string number string - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 118
Default Range system.blade.bladeFaultOn Number 0x0 HwErrMsk 0x0 to 0xffff system.blade.bladeFaultOnHwErrMsk If this field is set to a value other than 0, then any non fatal HW ASIC data parity error will cause the problem blade to be powered off. Examples To enable signed firmware services - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 119
. Examples To display sample data streams you can use with diagnostics: switch:admin> datatypeshow Pattern type example BYTE_FILL WORD_FILL QUAD_FILL BYTE_NOT WORD_NOT QUAD_NOT BYTE_RAMP 01 02 05 0b 17 2f 5e bd 7b f6 ec d8 b0 60 c0 11 55 16 fc d7 17 65 a9 87 5f 44 be 5a d0 de bc a5 12 bc - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 120
switch is forwarded to the principal switch and distributed to the fabric. It may take up to 64 seconds for the switches support. If the switch is operating in FICON Management Server mode (fmsmode), setting the date is subject to the director switch:admin> date Fri Jan 29 17:01:48 UTC 2007 switch: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 121
date 2 See Also errShow, ficonCupSet, ficonCupShow, portLogShow, tsClockServer, tsTimeZone, upTime Fabric OS Command Reference 95 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 122
the debug and verbosity levels. Module names are case sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg 96 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 123
of cfgEnable d_efault_Cfg. • If zoning receives a cfgDisable command from a remote switch that does not support default zoning, zoning rejects the cfgDisable command in the second phase of RCS because the remote switch does not convert the cfgDisable command to cfgEnable d_efault_Cfg. Sets the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 124
record is generated for each use of this command. Displays the current state of the default zone access mode. Notes This command requires a Brocade Advanced Zoning license. This command must be run from the primary FCS switch. Zone object names beginning with the d_efault_ prefix are reserved for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 125
designed to operate on fixed-port-count products. -all If specified, all blades clear. If no operand is specified, the default is to clear all bad port flags. Examples To clear the diag software flag: switch:admin> diagclearerror 8 ERROR: DIAG CLEARERR Diagnostics Errors Cleared, port: 8/31 Err - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 126
POST. A reboot is not required for this command to take effect. Operands none Examples To disable the POST during future power ons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also diagEnablePost 100 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 127
command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the POST during future power ons: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost Fabric OS Command Reference 101 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 128
platforms such as the FR4-18i, FA4-18, FC10-6, Brocade 7500, 4900, and AP 7600. The command is allowed to run on these platforms to maintain consistency across mixed blade environments, but it does not affect the operations of the switch. Your use of the functionality made available through this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 129
See Also USR_SEED DIAG_USR_SEED USR_SPECIAL DIAG_USR_SPECIAL (output truncated) none diagEnv 2 0x0 0x0 Fabric OS Command Reference 103 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 130
fail limit to a specified value. The fail limit controls the number of failures before certain diagnostic test methods aborts. The exact use of To change the fail limit from 1 to 5: switch:admin> diagfaillimit -show Fail Limit is 1. switch:admin> diagfaillimit 5 Fail Limit is now 5. Config - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 131
execution. This process takes a few seconds to complete. Use default operands when running diagnostics commands. Non-default settings require detailed knowledge of the underlying hardware and are intended for support personnel only. Contact support if you want to use these operands. The execution of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 132
a reboot to take effect. POST mode modifies the behavior of the diagnostics daemon program to inhibit testing of switch blades when the system is first powered on or a new blade is added. To enable or disable diagnostic POST, the recommended method is to use diagEnablePost and diagDisablePost. The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 133
to take effect. Retry mode modifies the behavior of the diagnostic test methods, power-on self-test (POST), and burn-in scripts. The exact behavior depends on is displayed. Examples To view the current retry mode value: switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 134
are available from the burninErrShow command on a per-blade basis. When power cycles occur, the burn-in activity is restarted at the test that operands: --slot slotnumber Specify which slot number to update. If this option is not specified at all, then all slots on the switch are set up for burn-in. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 135
Using the full parameters, variables can be updated noninteractively. In interactive mode, the current value, default value, and be specified manually in this case. Examples To update diagnostic command parameters: switch:admin> diagsetcycle switchburnin.sh -show CURRENT - KEYWORD : DEFAULT 1 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 136
number Specify which slot to operate on. If this option is not specified, the default slot 0 is used. The default slot is designed to operate on fixed-port-count products. By default displays. The default value is 0. Examples To display diagnostic status on a switch blade: switch:admin> diagshow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 137
not require a reboot to take effect. The skip test flags are used to skip the execution of certain POSTs that might prove hazardous to normal switch operation. The exact use of this flag is determined by the POST scripts and the specific test methods used. Operands This command has the following - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 138
such as the FR4-18i, FA4-18, FC10-6, Brocade 7500, 4900, and AP 7600. The command is allowed to run on these platforms to maintain consistency across mixed blade environments, but it does not affect the operations of the switch. Operands The follow is optional: slotnumber Specifies the slot - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 139
This command has the following operands: --slot number Specify the slot to stop burn-in. If no slot is specified, this command executes on all slots in the logical switch. This operand is optional. Examples To stop burn-in mode on a switch: switch:admin> diagstopburnin --slot 1 No burn-in script - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 140
the debug and verbosity levels. Module names are case sensitive. This operand is optional. Examples To display information about a specific module name NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg 114 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 141
is a semicolon-separated list of one of the following: • switch domain numbers • switch names • switch WWNs A wildcard "*" may be specified to include all switches in the fabric that support the distribute feature. Switches running firmware older than o v5.3. ignore the AUTH, FCS, and IPFILTER - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 142
" -d "*" Wildcard domains are: 1 3 5 To distribute the FCS policy, and the Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "FCS;PWD" -d "*" To distribute the AUTH and FCS policies to all switches in the fabric that run v5.3.0 or later - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 143
change occurs. Refer to dlsSet for a full description of load sharing. This command should occasional routing changes correctly. DLS is not supported in certain routing policies. Refer to load sharing option: switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 144
to turn on DLS when a fabric change occurs. Routing is generally based on the incoming port and the destination domain. This means that all the achieved with this setting. The DLS option is on by default. DLS is not supported in certain routing policies. Refer to aptPolicy for more information - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 145
. Refer to dlsSet for a description of load sharing. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing policies Examples To display the current DLS option setting: switch:admin> dlsshow DLS is set See Also dlsSet, dlsReset Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 146
that may be in place. Operands none Examples To set the DNS parameters for the system: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit Select an item: (1..4) [4] 2 Enter Domain Name: [] domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 147
switch is attached. This command is only meaningful for the products that are embedded in a blade server or storage chassis. Most of the options are applicable to a specific platform. Options that do not apply to a platform are identified with a "Not supported the serial number assigned by the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 148
instances on this control processor (CP). Synopsis errclear Description Use this command to clear all internal and external error log messages for all switch instances on this CP. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 149
operand is optional. Examples To display the start and end delimiter: switch:admin> errdelimiterset delimiter start string: delimiter end string: See Also To change the start and end delimiter (with sample output): switch:admin> errdelimiterset -s "Start" -e "End" Start2003/03/10-09:54 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 150
Sequence number for the message Security audit flag Security audit logged. AUDIT displays in the field. Severity Severity of the message. Valid values include INFO, WARNING, ERROR, and CRITICAL. Switch name Switch name for the generator of this message, or "chassis". Message Message body - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 151
set a filter for an error log destination. A filter is set based on the severity level of the messages. If no parameters are specified, "ERROR", or "CRITICAL". Examples To display the current filter settings: switch:admin> errfilterset console: filter severity = WARNING See Also To set the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 152
in place. Operands none Examples To display a list of all defined error log modules: switch:user> errmoduleshow Module IDs: 1 KT 2 UT 5 LOG 6 CDR 9 PIXE 10 EGR 13 4 KTRC 8 PISP 12 PIC 16 AUTH 20 CER 24 CONF See Also errDump, errShow 126 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 153
Sequence number for the message Security audit flag Security audit logged. AUDIT displays in the field. Severity Severity of the message. Valid values include INFO, WARNING, ERROR, and CRITICAL. Switch name Switch name for the generator of this message, or "chassis". Message Message body - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 154
exit command is an accepted synonym for logout, as is typing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See Also logout 128 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 155
to display the state of a port, relative to the fabric, as well as a list of pending commands. The following information displays: Port The port number. State The state of the port: P0 Port Offline P1 Port Online P2 ELP ACC Received P3 Link Reset Done I0 Trunk Initiator: EMT Sent - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 156
port to display, followed by a slash (/). portnumber Specifies the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display fabric port information: switch:admin> fabportshow 4/14 Fabric Port Information Port: State: List: List - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 157
See Also Flags: nbrWWN: nbrPort: lr_tid: red_ports: 10 11 62 63 0x280120 10:00:00:60:69:80:06:cf 5 0x1005dbd8, IDLE STATE Open commands pending No commands pending portShow fabPortShow 2 Fabric OS Command Reference 131 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 158
this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the retry count of Fabric OS commands: switch:user> fabretryshow SW_ILS E_Port ELP EFP HA_EFP DIA RDI BF FWD EMT ETP RAID GAID ELP_TMR GRE ECP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 159
. By default, the fabric log is enabled. -e | --enable Enables fabric log. -r size | --resize size Changes the maximum number of log entries. The given size has to be at least 2 and a power of 2; otherwise, the command fails. Examples To change the number of entries: switch:admin> fabriclog - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 160
2 fabricLog See Also Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid fabPortShow, fabStatsShow 134 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 161
mode. Synopsis fabricprincipal [-fhq] [mode] Description Use this command to set principal switch selection mode for the switch. The implementation of the fabricPrincipal command is based solely on mechanisms specified in the Fibre Channel standards. These mechanisms provide a preference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 162
Router symbolic name. This field will be empty if the switch is not an FC Router of it the FC Router does not support it. The execution of this command is subject to 00:60:69:00:02:0b 192.168.64.180 192.168.65.180 >"sw180" 66: fffc42 10:00:00:60:69:00:05:91 192.168.64.60 192.168.65.60 "sw60" - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 163
192.168.65.180 >"sw180" 1080::8:800:200C:1234/64 2: fffc42 10:00:00:60:69:00:05:91 192.168.64.60 192.168.65.60 "sw60" The Fabric has 2 switches. To show additional details of the FC Router, if present: switch:admin> fabricshow -m Switch ID Name ENET IP Addr FC Router FC Router - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 164
21 0x279 11957:83 *ELP Sending ACC F2,P1 F2,P2 21 0x279 11957:87 ELP ACC Receive F2,P2 F2,P2 21 0x277 switch:admin> fabstateclear switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid See Also fabStateShow, fabricLog 138 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 165
number of entries. It has to be at least 2 and a power of 2; otherwise, the command fails. Examples To change the number of entries: switch 21 0x277 switch:admin> fabstateresize 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 166
to Admin Domain restrictions that may be in place. Operands none Examples To display the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 *Start 2 * F_S_TOV Timer F2,NA F2,NA NA - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 167
the statistics for the fabric. The information displays as follows: • Number of times a switch domain ID has been forcibly changed • Number of E_Port offline transitions • Number of fabric reconfigurations • Number of fabric segmentations due to: • Loopback • Incompatibility • Overlap • Zoning - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 168
2 fabStatsShow Eport Isolated: 0 See Also fabRetryShow 142 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 169
Fabric Switch State Structure Information State: D0 Stage: warm done Rdi Receive Timer: 0x10069400, IDLE STATE Unconfirmed Sw Timer: 0x10069508, IDLE STATE NTP Timer: 0x100695b8, IDLE STATE ME Timer: 0x10069610, IDLE STATE Principal Domain: 2 Upstream Port: 64 Principal - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 170
speed to 0. This command is not available on nonbladed systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin Domain operand: unit Specifies the fan unit number to disable. Examples To disable a fan unit: switch:admin> fandisable 1 Fan unit 1 has - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 171
systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operand: unit Specify the fan unit number to enable. Examples To enable a fan unit: switch:admin> fanenable 1 Fan - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 172
hardware tolerance and has stopped. In this case, the last known fan speed is displayed. The output from this command varies depending on switch type and number of fans present. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 173
2 fastboot Reboots the Control Processor (CP), bypassing Power-On Self-Tests (POST). Synopsis fastboot Description Use To reboot the Control Processor, without executing POST on startup: switch:admin> fastboot See Also diagDisablePost, diagEnablePost, reboot Fabric OS Command Reference 147 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 174
latency and improves the number of write transactions per second over long distances. A blade can be configured either to support FC fastwrite or FCIP (default supported when FC fastwrite is disabled). When the blade is configured to support a particular feature, the blade must be rebooted. After - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 175
fastwritecfg 2 To disable FC fastwrite: See Also switch:admin> fastwritecfg --disable 7 !!!! WARNING !!!! Disabling this feature requires power-cycling of the affected blade to take effect and may take up to 5 minutes to complete. Non-bladed switches will be rebooted. In all cases, data traffic - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 176
using the cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory using the cfgSave of the following methods: A fabric domain and area number pair (for example, "1,2"). View the area numbers for ports using the switchShow command. • WWNs ( - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 177
. When a Fabric Assist zone member is specified by physical fabric port number, then all devices connected to that port are in the Fabric Assist enabled using the cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory using the cfgSave command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 178
three Fabric Assist zones using a mixture of port numbers and Fabric Assist zone aliases: switch:admin> fazoneCreate "Red_fazone", "H{1,0};loop1" switch:admin> fazoneCreate "Blue_fazone", "H{1,1};array1; 1,2;array2" switch:admin> fazoneCreate "Green_fazone", "1,0;loop1;H{1,2};array2" See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 179
using the cfgShow command). For the change to become effective, it must be enabled using the cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory using the cfgSave command. When FCS policy is enabled, this command can be issued only from the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 180
using the cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory using the cfgSave of the following methods: A fabric domain and area number pair (for example, "1,2"). View the area numbers for ports using the switchShow command. WWNs (for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 181
preceded by a pattern. This operand is optional; if omitted, the value defaults to 0. Examples To display all Fabric Assist zones beginning with the letters A through C: switch:admin> fazoneshow "[A-C]*" fazone: Blue_fazone 1,1; array1; 1,2; array2 See Also fazoneAdd, fazoneCreate, fazoneDelete - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 182
compression processor, and GigPHY. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 183
See Also fcipPathTest fcipChipTest 2 Fabric OS Command Reference 157 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 184
supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default bypass data compression for the test. By default, data compression is used. This setting - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 185
fcipPathTest 2 Running fcippathtest Test Complete: fcippathtest Pass 10 of 10 Duration 0 hr, 1 min & 50 sec (0:1:50:942). passed. Diagnostics See Also When a failure is detected, the test might report one or more of the following: PATH_TEST_ERR PATH_TEST_CHIP_INIT_ERR PATH_TEST_IMAGE_ERR - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 186
:f9:39 Target Port WWN: 50:05:07:65:05:83:f9:39 Target Pid: 144e8 Number of LUNs returned by query: 1 LUN ID: 0x00 To display the LUN information of a list of port WWNs: switch:admin> fclunquery -w 20:00:00:04:cf:5d:cf:0e Target Index: 1 Target Node WWN: 20 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 187
Service , and an arbitrary number of bytes as specified supported on all devices. In such cases, the response could be either an ELS reject or a request timeout. By default 16 "pad" bytes, which are used to fill out the request frame payload sent. This is useful for diagnosing data-dependent problems - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 188
one device that accepts the request and another device that rejects the request: switch:admin> fcping 10:00:00:00:c9:29:0e:c4 21:00:00 that accepts the request and another device that does not respond to the request: switch:admin> fcping 0x020800 22:00:00:04:cf:75:63:85 Source: 0x20800 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 189
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To clear the FCPD debug information log: switch:admin> fcplogclear See Also fcpLogDisable, fcpLogEnable, fcpLogShow Fabric OS Command Reference 163 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 190
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable the FCPD debug information log: switch:admin> fcplogdisable See Also fcpLogClear, fcpLogEnable, fcpLogShow 164 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 191
(debug command). Synopsis fcplogenable Description Use this command to enable the debug information logged for FCPD. Debug information logging is enabled by default. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 192
2 fcpLogShow fcpLogShow Displays the FCPD debug information log (debug command). Synopsis fcplogshow Description Use this command to display the debug information logged at various stages of FCP device probing. Operands none Examples To display the FCPD debug information log: See Also Time Stamp - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 193
to display, followed by a slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. Examples To display the FCP probe information: switch:admin> fcpprobeshow 4/4 port 52 is L-Port and it is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 194
display, followed by a slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. Examples To display the FCP RLS information: switch:admin> fcprlsshow 2/5 0xda 0xdc link fail 0 0 loss sync - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 195
/enabled. Valid values are 1-128. --help Displays the list of actions possible. EXAMPLES To display the current configuration of the switch. switch:admin> frcbcastconfig --show Broadcast configuration is disabled for: fid 2 fid 128 fid 33 SEE ALSO bcastshow, portRouteShow Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 196
in register N is reached (0x80000000 for a 32-bit register). For example, a 6-bit supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 197
fcrChipTest 2 Diagnostics When a failure is detected, the test might report one or more of the following: DMA_ALLOC_FAIL DMA_READ_ABORT DMA_READ_TIMEOUT CHIP_INIT_TIMEOUT BIST_TIMEOUT BIST_FAIL See Also fcrPathTest, miniCycle, portLoopbackTest Fabric OS Command Reference 171 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 198
fabric ID uniquely identifies a fabric in FC Router configurations. The backbone fabric is the fabric attached to the U_Ports-for example, E/F_Ports-of this switch. The backbone fabric ID must be unique across all FC Router-connected fabrics. The current Backbone Fabric ID can be displayed using the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 199
for IPv6 support. When IPv6 number for the EX_Port. FID The fabric ID of the EX_Port. Neighbor Switch Info (WWN, enet IP, name) The WWN, Ethernet IP address, and switch name of the switch 32.66.220, 220::10:32:66:220 "sw220n" EX_Port FID Neighbor Switch Info (enet IP, WWN, name) 16 80 10.32 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 200
2 fcrFabricShow See Also fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow 174 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 201
sets the maximum LSAN count. Synopsis fcrlsancount [max-lsan-count] Description Use this command to set or display the maximum number of LSAN zones that can be configured on the router. By default, this limit is set to 3000, which is also the minimum. This parameter can have the maximum value set - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 202
, if edge fabrics FIDs 1, 2, 3, 4, 5 are online, the default is that all edge fabrics have two-way communication. In the case where switch and not distributed to other FCR switches automatically. The best practice is to enter the same information for all the FCR switches in the backbone that supports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 203
Fabric ID 2 4 5 4 7 10 19 To view the LSAN Zone static and default/dynamic binding in the backbone: For example, in the backbone where online fabrics are: 1, 2, 4, 5, 7, 8, 10 switch:admin > fcrlsanmatrix --fabricview LSAN MATRIX is activated Fabric ID 1 Fabric ID 2 4 5 4 7 10 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 204
:06:2b:0e:4d:e5 52 10:32:16:90:28:dd:d0:03 52 10:32:16:91:24:dd:d0:07 52 10:32:16:91:25:dd:d0:06 78 10: To apply the changes persistently: switch:admin > fcrlsanmatrix --apply View all the static and the default/dynamic fabric binding in the backbone. switch:admin > fcrlsanmatrix --fabricview LSAN - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 205
fcrPathTest 2 fcrPathTest Tests the data path connection between FC Router FPGA and the central ASIC. Synopsis fcrpathtest [--slot slotnumber][-unit number][-path mode][-nframes count] Description Use this command to verify the data path connecting the FC Router FPGA and the central ASIC by - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 206
command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -unit number Specifies the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 207
fabric as this FC Router. The default output displays only physical device information relevant The -f and -w operands allow searching for physical devices based on fabric ID or port World Wide Name. " fabric. Remote failure counter represents the number of times the device login failed due - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 208
2 fcrPhyDevShow in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09:0e 0100ef 3 50:05:07:65:05:84:0b:83 0100e8 Total devices displayed: 3 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow 182 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 209
fcrProxyConfig 2 fcrProxyConfig Displays or configures proxy devices presented by an FC Router. Synopsis fcrproxyconfig [-s importedFID devWWN slot][-r importedFID devWWN] Description Use this command to display or set the persistent configuration of proxy devices presented by the local FC - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 210
:22:33:44:55:66:77 f101 To remove device WWN 00:11:22:33:44:55:66:77 from its persistent slot in fabric 5: switch:admin> fcrproxyconfig -r 5 00:11:22:33:44:55:66:77 WWN deleted from proxy device slot See Also fcrPhyDevShow, fcrProxyDevShow, fcrXlateConfig, lsanZoneShow, switchShow 184 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 211
Routers on the same backbone fabric as this FC Router. The default output displays only proxy device information relevant to this FC Router. are listed by fabric. Search parameters -f and -w allow searching for proxy devices based on fabric ID or port WWN. "No proxy device found" is displayed if - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 212
2 fcrProxyDevShow -w wwn Displays proxy devices with the specified port WWN. Examples To display the physical devices relevant to this FC Router: switch:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 213
being connected to a translate domain slot. A lost is the port number and AL_PA combination. The slot-to-device WWN association is persistently the phantom switch might still be accessible through other switches. Across the switch reboot, the allocation starts from the next usable WWN base from the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 214
resource usage for the local FC Router: switch:Admin> fcrresourceshow Daemon Limits: LSAN Zones: 32768 6446 Port Limits: Max proxy devices: 2000 Max NR_Ports: 1000 Currently Used(column 1: proxy, column 2: NR_Ports): 48 | 0 0 49 | 0 0 50 | 0 0 52 | 0 0 53 | 0 0 54 | 0 0 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 215
the current link costs for all ports on the switch. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port whose cost is to be displayed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 216
2 fcrRouterPortCost To set the cost of an EX_Port: switch:admin> fcrrouterportcost 7/10 10000 See Also switchShow, fcrRouteShow, portCfgEXPort 190 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 217
traffic between imported fabrics, creating a meta-SAN. There are FC Router ports that reside cascaded backbone/intermediate fabrics are currently not supported, an NR_Port provides a path to of the Principal Switch in the Dest. Fabric The World Wide Name of the principal switch in the destination - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 218
is the preferred domain ID. You can set the preferred domain ID when the translate domain is not active and is persistently saved. The principal switch attempts to provide the translate domain with the requested domain ID, but might not provide it if there are domain ID conflicts with other domains - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 219
:0f:05 To set the preferred domain ID of the translate domain created in fabric 2 that represents remote fabric 3 to a value of 8: switch:admin> fcrxlateconfig 2 3 8 xlate domain already configured, overwrite?(n) y To clear the preferred domain ID of the translate domain created in fabric 2 that - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 220
. Supported policies are Switch Connection Control (SCC), Device Connection Control (DCC) Password " that include switches running firmware versions older than v6.0. If a v5.3/5.2 switch joins a fabric -wide policy to NULL (default) or no fabric-wide consistency, use the policy Set "". 194 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 221
and Fabric Configuration Server (FCS) policies. All members specified in a given policy set s are automatically distributed to all participating switches in the fabric that support the policy. Refer to the DESCRIPTION section for specific exceptions. In the presence of a fabric-wide FCS consistency - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 222
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the FDMI cache: switch:admin> fdmicacheshow Switch entry for domain 3 state: known version: v310 wwn: 10:00:00:60:69:90:03:c7 HBAs: 10:00:00:00:c9:25:9b - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 223
Manufacturer: Emulex Network Systems Serial Number: 0000c9259b96 Model: LP9000 Model Description: Emulex LightPulse LP9000 1 Gigabit PCI Fibre Channel Adapter Hardware Version: 00000001 Driver Version: SLI-2 SW_DATE:May 3 2002, v5-2.11a2 **CT_TEST 1** Firmware Version: 03814101 OS Name and Version - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 224
" entries are not removed from the RNID database. Examples To clear the RLIR database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 225
control UAM User alert mode ASM Active=saved mode DCAM Director clock alert mode ACP Alternate control prohibited HCP Host control prohibited Examples To enable FMS mode for the switch: switch:admin> ficoncupset fmsmode enable fmsmode for the switch is now Enabled To set ASM bit in the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 226
operands: fmsmode Display the FICON Management Server (FMS) mode for the switch. modereg Display the FICON-CUP mode register. When parameter is modereg control UAM User alert mode ASM Active=saved mode DCAM Director clock alert mode ACP Alternate control prohibited HCP Host control - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 227
commands. Synopsis ficonhelp Description Use this command to display a list of FICON support commands, with descriptions. Operands none Examples To display a list of FICON commands: switch:admin> ficonhelp ficonclear Clears contents of the specified FICON management database ficoncupset - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 228
current. 0x40 Indicates the node ID of the storage port for RNID switch for RLIR is not valid. 0x50 Indicates the node ID of the number] Displays the WWN card number Power Supply [unit number] Displays the Power Supply card number Hardware Slot [unit number] Displays the Hardware Slot number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 229
number] FRU Part Number Displays the FRU part number. FRU Serial Number Displays the FRU serial number. Incident Count Displays the incident count. This number increases by 1 for each incident within the individual switch 0x80 FC-4 support not specified. 0xa0 Reserved. 0xc0 Reserved. 0xe0 Vendor - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 230
0x07 Terminal - Full screen if it support only. 0x09 Reserved. 0x10 Switch, if it is a switch switch. 0xID CHIPID if channel port has registered with the switch. 0xPN If switch has registered with the channel, PN represents the FL port number. Part Number Displays the switch chassis part number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 231
To display the local RNID database: switch:admin> ficonshow RNID { {Fmt Type PID Registered Port WWN Registered Node WWN flag Parm 0x18 N 502b00 50:05:07:64:01:00:15:8d 50:05:07:64:00:c1:69:ca 0x10 0x200110 Type number: 002064 Model number: 101 Manufacturer: IBM Plant of Manufacture - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 232
101 Manufacturer: IBM Plant of Manufacture: 02 Sequence Number: 0000000169CA tag: 052e } } To display the local and remote LIRR database: switch:admin> ficonshow LIRR fabric {Fmt Type PID Listener Port WWN Switch Port WWN Listener Type 0x18 N 502b00 50:05:07:64:01:00:15:8d 20:2b:00:60 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 233
1e:4e FRU part number: FRU serial number: 23000000602 FL2L0001071 {Listener Port Type Listener PID Listener Port WWN N 0x502b00 50:05:07:64:01:00:15:8d } } {FRU Failure [3]: Power Supply[4] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 234
, only FIPS compliant algorithms will be allowed. As part of FIPS 140-2 level 2 compliance, passwords, shared secrets and the private keys used in SSL/TLS, system login, etc. need to be zeroized. Power-up self tests will be executed when the switch is powered on to check for the consistency of the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 235
Disabled/None Verify FIPS prerequisites: switch:admin>fipscfg --verify fips Standby firmware supports FIPS SELF tests check has passed port number for the policy is in permit state. HTTP port number for the policy is in permit state. RPC port number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 236
firmwareDownload completes successfully and the CP is rebooted, the system switches the primary partition (with the old firmware) to the secondary, and the secondary partition (with the new firmware) to the primary. The default behavior of the firmwareDownload command is to automatically run the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 237
versions. In dual-domain systems, this command by default downloads the firmware image to both CPs in rollover mode to prevent disruption to application services. This operation depends on HA support. If HA is not available, you can still upgrade the CPs one at a time, using the -s option. All - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 238
on which Fabric OS version you are migrating from. See the Fabric OS Administrator's Guide "Firmware Download" chapter for restrictions on changing Fabric OS versions. To correlate Brocade blade names with blade IDs, use the slotShow command. The execution of this command is subject to Admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 239
option is only valid with the -a sas option. Examples To download the firmware to an HA switch over a network: switch:admin> firmwaredownload 192.168.166.30,johndoe,/pub/dist/release.plist,12345 The following BP blades are installed in the system. Slot Name Versions Scope of Impact 2 FR4 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 240
(all, or slot numbers) [all]: Server Name or IP Address: 192.168.32.10 Network Protocol (1-auto-select, 2-FTP, 3-SCP) [1]: User Name: userfoo File Name: /home/userfoo/dist/release.plist Password: To download SAS firmware without version compatibility checking: switch:admin> firmwaredownload -c Type - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 241
reached by the switch. • user does not have permission on host. • The password for the user is not specified correctly. • Indicated firmware does not exist on the host, or is not in the right format, or is corrupted. • The FTP or SSH service is not running on host. • Platform is not supported by the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 242
The following example shows the status of the firmwaredownload for an SAS image to the blades in slot 2 and 7. switch:admin> firmwaredownloadstatus [1]: Thu Jul 28 00:30:49 2005 Slot 2 (SAS): Firmware is being downloaded to the blade. It may take up to 30 minutes. [2]: Thu Jul 28 00:30:49 2005 Slot - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 243
to verify the firmware versions. To display the status of a firmware download on a Brocade director: switch:admin> firmwaredownloadstatus firmware. [5]: Mon Dec 19 18:47:56 2005 Slot 8 (FR4-18i): Firmware is being downloaded to the blade. This step may take up to 10 minutes. [6]: Mon Dec 19 18:48 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 244
has started on both active and standby CPs. [15]: Mon Dec 19 19:01:38 2005 Slot 5 (CP0, active): Firmware commit operation has completed successfully on active CP. [16]: Mon Dec 19 19:01:39 2005 Slot 5 (CP0, active): Firmwaredownload command has completed successfully. Use firmwareshow to verify - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 245
key used for validating the integrity of firmware images when signed firmware validation is enabled. Notes A firmware key should be installed on every switch as a part of the Fabric OS installation. The presence of a firmware key does not imply that the firmware signature will be checked during - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 246
restore the former active firmware image: switch:admin> firmwarerestore Restore old image to be active ... Restore both primary and secondary image after reboot. The system is going down for reboot NOW !! Broadcast message from root (ttyS0) Fri Oct 26 23:48 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 247
of the storage device. Operands none Examples To display the firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7. switch:admin> firmwareshow Slot Name Appl Primary/Secondary Versions Status 2 FA4-16 FOS v5.3.0 v5.3.0 SAS v3.0.0 v3.0.0 DMM v3.0.0 v3 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 248
the switch supports this option, from an attached USB device. A default firmware key is released as part of the firmware image and is downloaded to the switch during the firmware download process. The default key is used to download a new firmware. However, the firmware key may be changed by Brocade - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 249
.pem Network Protocol(1-auto-select, 2-FTP, 3-SCP) [1]: Password: Updating the public key, please wait... Public key successfully updated. To update the public key from an external USB device: switch:admin>Firmwarekeyupdate -U /usb/usbstorage/brocade/firmwarekey/pubkey.pem Updating the public key - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 250
This command has the following operands: -e |--enable feature Enables a feature on the switch. Valid values for feature are: fcr The FC Routing service will be enabled on this switch. The FC Routing service is by default disabled. Use fosConfig --show to determine the state of the FC Routing - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 251
can be run while the switch state is "online". The iSNSC service will be disabled on this switch. This command can be run while the switch state is "online". Displays the current operating status of features on the switch. Notes The features shown here may not be supported on all platforms. If you - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 252
command to guide the user supported value, specifying the replacement of the WWN card. Examples To replace the World Wide Name card: switch power cycle, or CP failover, please follow the recovery procedure in Core Switch WWN frureplace command and follow the instructions to complete the operation. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 253
FSPF protocol. Domain number of local switch. State of the local switch. TRUE if the domain of the local switch is currently confirmed. Bit map of all the ISL. Bit positions correspond to the default areas of the ports. Bit 0 refers to default area of the switch, bit 1 refers to default area 1, and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 254
2 fspfShow version = 2 domainID = 131 switchOnline = TRUE domainValid = TRUE isl_ports[0] = 0x00000000 isl_ports[1] = 0x74000000 trunk_ports[0] = 0x00000000 trunk_ports[1] = 0x02000000 f_ports[0] = 0x00400000 f_ports[1] = 0x00000000 seg_ports[0] = 0x00000000 seg_ports[1] = - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 255
to disable the alarms. If no operand is specified, the default value is 0 (alarms deactivated). This operand is optional. Examples To enable alarms in Fabric Watch: switch:admin> fwalarmsfilterset FW: Alarms are already disabled switch:admin> fwalarmsfilterset 1 FW: Alarms are already enabled See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 256
that may be in place. Operands none Examples To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also fwAlarmsFilterSet 230 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 257
subject to Admin Domain restrictions that may be in place. Operands none Examples To initialize all classes under Fabric Watch: switch:admin> fwclassinit fwClassInit: Fabric Watch is updating... fwClassInit: Fabric Watch has been updated. See Also fwConfigReload, fwConfigure, fwShow Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 258
Admin Domain restrictions that may be in place. Operands none Examples To reload the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See Also configDownload, configUpload, fwClassInit, fwConfigure, fwShow 232 Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 259
Switch all platforms support fans or power supplies. support VE and VEX ports, except for State Changes. 2. The E_port class has the same port limitations as the port class except under the following condition: On a Brocade 48000 with a FR4-18i blade, or on the Brocade Administrator's Guide. The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 260
The execution of this command is subject to Admin Domain restrictions that may be in place. In Access Gateway mode, only the following classes are supported. F/FL Port (Copper) class is supported only on Embedded platforms. 234 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 261
CRCS RX Performance TX Performance Customer Defined Flash Not all platforms support fans or power supplies. If you attempt to configure values for these items a certain port. Examples To configure thresholds in Fabric OS mode: switch:admin> fwconfigure 1 : Environment class 2 : SFP class Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 262
1 To configure thresholds in Access Gateway mode: switch:admin> fwconfigure 1 : Environment class 2 : SFP class 3 : Port class 4 : F/FL Port (Optical) class 5 : Resource class 6 : quit Select a class => : (1..6) [6] 1 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 263
1 : refresh 2 : disable a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to previous page Select choice => : (1..5) [5] 5 See Also fwClassInit, fwConfigReload, fwShow fwConfigure 2 Fabric OS Command Reference 237 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 264
and actions. Based on these switch:admin> fwfrucfg The current FRU configuration: Alarm State Alarm Action Slot 0 1 Power 16 Configurable Alarm Actions are: Errlog-1, E-mail-16 Slot Alarm State: (0..31) [0] 3 Slot Alarm Action: (0..17) [1] Power Supply Alarm State: (0..31) [0] Power - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 265
level to custom Set boundary & alarm level to default Show thresholds monitored or port persistence time Show sensor readings Set switch status policy parameters Show switch status policy parameters Show overall switch status Show switch temp readings See Also none Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 266
command to display or modify the configuration and status of the Fabric Watch email alert in the switch. Switch elements monitored by Fabric Watch are divided into classes, and email alerts are based on the classes. Each class can configure one email address as the alert message's receiver. For an - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 267
4 : Send Test Mail 5 : Set Recipient Mail Address for Email Alert 6 : Quit Select an item => : (1..6) [6] 5 Mail Config Menu 1 : Environment class 2 : SFP class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Optical) class 7 : Alpa Performance Monitor class 8 : End-to-End - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 268
based on the following contributors: Port Errors: LFA Number of link loss occurrences exceeded limit for time period LSY Number SRX SFP receive power is out of specification STX SFP transmit power is out Fabric Watch license. Port errors are not supported for virtual ports and SFP errors are - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 269
on all faulty ports o Report based on all offline ports If no option is specified, all ports are displayed. Examples To retrieve a port detailed report for a switch configured with an IPv6 address: switch:user> fwportdetailshow Port Detail Report Switch Name: switch IP address: 1080::8:800 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 270
2 fwPortDetailShow See Also 001 F HEALTHY 409:09 014 F HEALTHY 409:09 015 E HEALTHY 409:09 switchStatusShow 244 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 271
port availability. The information displayed includes total uptime, total downtime, number of faulty occurrences, and total percent of downtime for each port. Notes In an AD-aware environment, this command is allowed only if the local switch is a member of the current Admin Domain. This command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 272
period in which a port must be persistently in a state before being actually being recognized as such. Examples To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See Also fwShow 246 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 273
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To set alarm levels to custom values: switch:admin> fwsettocustom Committing configuration...done. See Also fwSetToDefault Fabric OS Command Reference 247 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 274
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To return alarm levels to default values: switch:admin> fwsettodefault Committing configuration...done. See Also fwSetToCustom 248 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 275
Guide. In Access Gateway mode, only the following class thresholds are supported. F/FL Port (Copper) class threshold is supported only thresholds disabled. Examples To display thresholds for a fan in the SFP class: switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 3 : - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 276
(1..12) [12] 1 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an area => : (1..4) Fan 2 2518 RPM envFan003 Env Fan 3 2481 RPM switch:user> fwshow 1 : Show class thresholds 2 : Detail Event 0 occurred 1 time, last at 16:30:17 on 12/09/2011 (continued on next - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 277
09/2011 * Event 5 occurred 1 time, last at 16:30:23 on 12/09/2011 Callbacks: No callbacks are registered. To show port persistence time: switch:admin> fwshow --port --persistence FW: current port persistence time = 18s switch:user> fwShow --disable --port Port Threshold Status 1 disabled - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 278
commands typed into the shell; the oldest commands are replaced as new ones are entered. Operands none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 portdisable 2 4 portenable 2 5 switchshow See Also none 252 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 279
Use this command to disable the High Availability feature in the switch. If the HA feature is already disabled, this command does Operands none Examples To disable the High Availability feature: switch:admin> hadisable HA is disabled See Also haEnable Fabric OS Command Reference 253 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 280
feature in the switch. This command displays the following information: • Local CP state (slot number and CP ID) • Remote CP state (slot number and CP ID) running, but the background health diagnostic has discovered a problem with the blade. The logs should be checked to determine the appropriate - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 281
SWITCH Ethernet IP Address: 10.32.227.64 Ethernet Subnetmask: 255.255.240.0 Fibre Channel IP Address: 220.220.220.64 Fibre Channel Subnetmask: 255.255.240.0 CP0 Ethernet IP Address: 10.32.227.66 Ethernet Subnetmask: 255.255.240.0 Host Name: cp0 Gateway IP Address: 10.32.224.1 CP1 Ethernet IP Address - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 282
Use this command to enable the High Availability feature in the switch. If the HA feature is already enabled, this command does nothing To enable the High Availability feature in the switch: switch:admin> haenable HA is enabled See Also haDisable 256 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 283
the failover, even while traffic is continuing to flow. This command is supported only on systems with dual CP cards. The execution of this command is force the failover of the active CP to the standby CP in the switch: switch:admin> hafailover Local CP (Slot 7, CP1): Active, Warm Recovered Remote - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 284
number and CP ID), warm or cold, recovering or recovered • Remote CP state (slot number a problem with the blade. The command may not be supported on non-bladed systems. The execution of switch:admin> hashow Local CP (Slot 6, CP1): Active, Cold Recovered Remote CP (Slot 5, CP0): Non-Redundant switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 285
See Also haDisable, haEnable, haFailover haShow 2 Fabric OS Command Reference 259 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 286
. The execution of this command is subject to Admin Domain restrictions that may be in place. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop 260 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 287
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable the HA state synchronizing process: switch:admin> hasyncstop See Also haFailover, haShow, haSyncStart Fabric OS Command Reference 261 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 288
command Specify the command name, with or without quotation marks. This operand is optional. Examples To display help information for the help command: switch:admin> help help See Also diagHelp, fwHelp, licenseHelp, perfHelp, routeHelp, zoneHelp 262 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 289
respectively contain the factory part number and factory serial number, if applicable: Factory Part Number xx-yyyyyyy-zz or Not available Factory Serial Number xxxxxxxxxxxx or Not available The size of the history log depends on the HW platform: The Brocade 48000 director supports 100 history log - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 290
which records the insertion and removal of FRUs on a switch or chassis. This command supports two modes of handling new log entries once the on the HW platform: The Brocade 48000 Director supports 100 history log entries. The DCX Data Center Backbone Director supports a maximum log size of 50 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 291
contain the factory part number and factory serial number, if applicable: Factory Part Number xx-yyyyyyy-zz or Not available Factory Serial Number xxxxxxxxxxxx or Not available The size of the history buffer depends on the HW platform: The Brocade 48000 director supports 100 history log - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 292
Slot 3 Inserted at Tue Aug 14 13:53:40 2001 Factory Part Number: 60-0001532-03 Factory Serial Number: 1013456800 CP BLADE Slot 6 Inserted at Tue Aug 14 13:59:50 2001 Factory Part Number: 60-0001604-02 Factory Serial Number: FP00X600128 POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 293
Use this command to display the version of the Java plug-in supported by Web Tools. This command also displays the URL from which the Operands none Examples To display the Java plug-in version: switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,3,1 javaplugin.homeURL - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 294
PID The process ID of the process PPID The process ID of the parent process C Processor utilization for scheduling PRI Priority number of the process; higher numbers mean lower priority NI Nice value used in priority computation ADDR Memory address of the process SZ The total size of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 295
the following operand: processID Specifies the process name or process ID for the process to display. Examples To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 296
this command through the serial console port, follow this scenario for the ifModeSet command: switch:admin> ifmodeset eth0 Exercise care when using this command. Forcing the link to an operating mode not supported by the network equipment to which it is attached may result in an inability to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 297
-negotiation to 10 Mbit/sec half-duplex operation, when entering this command through the serial console port: switch:admin> ifmodeset eth0 Auto-negotiate (yes, y, no, n): [yes] n Force 100 Mbps / Full Duplex (yes, y, no, n): [no] n Force 100 Mbps / Half Duplex (yes, y, no, n): [no] n Force 10 Mbps - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 298
eth0, where eth is the network interface and 0 is the physical unit. Examples To display the link operating mode for the "eth0" Ethernet interface: switch:admin> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok MAC Address: 00:60:69:D0:24:40 See Also ifModeSet 272 Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 299
structures associated with FSPF interfaces (E_Ports) on the switch: The permanently allocated Interface Descriptor Block (IDB). The ifNo Interface number. masterPort Port number of the trunk master port, if present, of the trunk group of which this port is a part. defaultCost Default cost of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 300
parameters) received from the neighbor switch. nLsuIn Number of LSUs received from the neighbor switch. nLsaIn Number of LSAs received from the neighbor switch. attHloOut Number of attempted transmissions of Hello frames to the neighbor switch. nHloOut Number of Hello frames transmitted to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 301
switch. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number .512 delay = 1 lastScn = 16 &dbRetransList = 0x1008c6a0 &lsrRetransList = - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 302
2 interfaceShow lsrRtxTID = 0x1008c848 inactTo = 80000 helloTo = 20000 (continued on next page) rXmitTo = 5000 nCmdAcc = 7 nInvCmd = 0 nHloIn = 2 nInvHlo = 0 nLsuIn = 2 nLsaIn = 3 attHloOut = 2 nHloOut = 2 attLsuOut = 3 nLsuOut = 3 attLsaOut = 2 nLsaOut = 2 See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 303
interoperability with McDATA switches within a Brocade fabric. Fabric OS v6.0 introduces a new M-EOS compatible McDATA Open Fabric Mode (interopMode 3) on all platforms that support McDATA Fabric Mode (interopmode 2). Open Fabric Mode is intended specifically for adding FOS-based products into M-EOS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 304
of the switch WWN is no longer replaced with a McDATA OUI. The Brocade OUI default states and can be modified using the configure command. For information on supported hardware platforms and procedures regarding OS v5.2.2_NI to v6.0.0 migration, refer to the Fabric OS Administrator's Guide - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 305
take effect. Do you want to continue? (yes, y, no, n): [no] y To enable McDATA Open Fabric mode on a disabled switch: switch:admin> interopmode 3 McDATA Open Fabric mode is enabled The switch effective configuration will be lost. The system will reboot to allow the change to take effect. Do you want - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 306
this command to turn off the IOD option. The IOD option is turned off by default; however, if the IOD option was turned on using iodSet, this command can be Operands none Examples To turn off the IOD option: switch:admin> iodreset switch:admin> iodshow IOD is not set See Also iodSet, iodShow 280 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 307
, frames are always delivered in order, even when the traffic between switches is shared among multiple paths. However, when topology changes occur in are not delivered out-of-order, even during fabric topology changes. The default behavior is for the IOD option to be off. This command should be - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 308
Use this command to display whether the IOD option is enabled or disabled. Operands none Examples To display the current setting of the IOD option: switch:admin> iodshow IOD is not set See Also iodReset, iodSet 282 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 309
number] -gate [--add x.x.x.x | --delete] Use this command to set the IP addresses on a switch, a CP, a BP, or a standalone AP. The command supports an interactive mode, which supports the Fabric OS Administrator Guide. To set IP Addresses interactively (IPv4 only): 1. On a chassis-based system, if no - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 310
from the specified or implied entity. -cp number | -sw number On a chassis-based system, specify CP or logical switch. Valid values for number are 0 or 1. On platforms with blade processors, the following additional command line options are supported with the --add or --delete options: -eth0 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 311
n On a chassis with a blade processor (BP), specify the slot number. On standalone platforms with a hidden BP, such as the AP76500, this parameter is not accepted. Examples To set the IPv4 addresses for switch number 1 on a chassis-based system in interactive mode: switch:admin> ipaddrset -sw - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 312
-domain systems, this specifies the switch number to display (0 or 1). -slot n For chassis systems specify the slot for a blade -eth0 -eth1 -gate For non-chassis-based switches, this command ignores all operands. Examples To display the IP address for logical switch 0: switch:admin> ipaddrshow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 313
proto protocol -act permit | deny --delrule policyname -rule rule number --transabort Description Use this command to manage IP filter policies. and IPv6 type in the active configuration. The active policy must be the default, or one of the policies in the defined configuration. Only the active - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 314
The policy rules are listed by the rule number in ascending order. There is no pagination default IP filter policies will return the IP management interface to its default supported with the --addrule option: -sip Specifies the source IP address. For IPV4 filter type, the address must be a 32 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 315
number, a range of port numbers, or a service name. -proto Specifies the protocol type, for example tcp or udp. -act Specifies the permit or deny action associated with this rule. rule rule_number Adds a new rule at the given rule index number port number, and to permit the rule: switch:admin> - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 316
2 iscsiCfg iscsiCfg Configures or displays iSCSI entities. Synopsis iscsicfg create auth -u username -s CHAP_secret [-h] iscsicfg --modify auth -u username -s CHAP_secret [-h] iscsicfg --delete auth -u username [-h] iscsicfg --clear auth [-h] iscsicfg --show auth [-u username] [-h] iscsicfg -- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 317
operands. Use --commit all to save all entity changes to nonvolatile memory. This triggers the propagation of changes to all iSCSI-enabled switches and blades in the fabric. Changes will not take effect until a --commit all command is issued. Make all necessary configuration changes before issuing - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 318
either one-way or mutual CHAP is enforced, based on the login frame from the host. -- DD is deleted. If a DD to be deleted is a part of a DD set, the set shall be modified to reflect is supported. Multiple entities may be specified as a comma-separated list. The IQN may be a maximum of 64 characters. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 319
. Actions on initiator are: --clear initiator [-h] Clears the iSCSI initiator database. --show initiator [-i initiator_name][-h] Displays all iSCSI initiators that the switch is aware of. If an initiator has attempted discovery or logon to a target, it will be displayed here. If initiator_name is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 320
-a CHAP The operation completed successfully. To display the target database: switch:admin> iscsicfg --show tgt Number of records found: 2 Name: State/Status: iqn.2005-10.com.brocade.tgt1 Offline/Defined Name: State/Status: iqn.2222-23.com.brocade:21:00:00:20:37:df:83:fc Online/Committed To - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 321
-w 22:00:00:04:cf:75:5b:9a -l 2-5:5-8 The operation completed successfully. To display LUN maps: switch:admin> iscsicfg --show lun Number of records found: 2 Target: iqn.2005-10.com.brocade.tgt1 Number of LUN Maps: 1 FC WWN Virtual LUN(s) 22:00:00:04:cf:20:5d:33 0 Physical LUN(s) 0 Target - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 322
the DD set database in verbose mode: switch:admin> iscsicfg --show ddset -v Number of records found: 1 Name: State/Status switches and their operational states (Displays switches that are capable of propagating iSCSI data base): switch:admin> iscsicfg --show fabric Switch ID Switch WWN Switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 323
2 See Also Number of records found: 1 Name iqn.1991-05.com.brocade:initiator1 IP Address 172.16.14.101 switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 Initiator details are: Name IP Address iqn.1991-05.com.brocade:isi154116.englab.brocade.com 172.16.14.101 No - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 324
-unit gbeports Specifies the GE port to test. By default, all the GE ports in the specified slot slotnumber will be used. This number will be between 0 and 7. 8 will mean all ports. Examples To run iscsichiptest: switch:admin> iscsichiptest --slot 7 -unit 1 -testtype 0 Running iscsichiptest Test - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 325
. Operands This command has the following iscsi support commands and operands: -fclunquery [-w wwn | -s] -iscsiportcfg -h -iscsiportcfg --clearstats slot/geport Clears the statistics on the port and closes the session. -iscsiportcfg --default slot/geport -iscsiportcfg --show slot/geport - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 326
2 iscsiHelp switch:admin> iscsihelp fclunquery Display a list of LUNs of FC target(s). fosconfig Enable/disable FabOS services iscsicfg Manage/display all iscsi configuration including authentication/virtual targets/discovery domains. iscsiportcfg Manage/display iscsi protocol related port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 327
of frames to send. The test will progress until the specified number of frames has been transmitted on each port. The default value is 100. Examples To run iscsipathtest: switch:admin> iscsipathtest --slot 2 -path 2 -nframes 10 Running iscsipathtest Test Complete: iscsipathtest Pass 10 of 10 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 328
default iSCSI port settings. Setting Default Error recovery level 0 Connections per session 1 Data digest support Disabled Header digest support Disabled Immediate data support the number of connections in addition to the other port-level information. slot Specifies the slot number. 302 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 329
This parameter only supports FC4-16IP blades in Brocade 48000 directors. geport -h Specifies the port number of a GbE port to be configured in the specified slot. Use -h on any option to display the help text for it. Examples To modify the port parameters: switch:admin> iscsiportcfg --modify - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 330
See Also iSCSI Task Reassign: Non FCP in PDU: Non FCP in Octet: Non FCP out PDU: Non FCP out Octet: Session details: Session Number: iSCSI Session Type: Initiator Name: Target Name: ISID: fosConfig, iscsiCfg, iscsiSessionCfg 0 17 2576 17 1352 1 Normal iqn.1991-05.com.microsoft:win-iscsi.lab - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 331
given target IQN. Examples To display the iSCSI session status: switch:admin> iscsisessioncfg --show Number of sessions found: 1 Session 1 Details: Initiator Name: iqn.1991-05.com.init:6a3-iscsi-053.englab.brocade.com Target Name: iqn.2002-12.com.brocade:2f:df:00:06:2b:0d:10:b9 Session type - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 332
time to retain Default time to wait Error recovery level Initial R2T 20s 2s 0 Off iSCSI Operating Login Parameters: Connection Level Connection Index: 1 Parameter Name Self Value Value Max. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 333
the connection redirection for iSCSI blades on the switch: switch:admin> iscsiswcfg --showconn -s all Number of records found: 1 Slot ICR Status 3 Disabled To display a target name prefix: switch:admin> iscsiswcfg --showgw Target name is: iqn.2002-12.com.brocade To change a target name prefix - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 334
as "sp:-------". Operands none Examples To display the ISL connections for the switch: switch:user> islshow 1: 33-> 29 10:00:00:60:69:80:4f: 1e:01:0b:4a TRUNK 6:162->160 10:00:00:60:69:e2:09:fa 7:208-> 16 10:00:00:05:1e:37:02:73 3 Termonator8 4 Dazzler_1 15 Stealth_05 5 fcr_meteor2 39 sprint170 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 335
the port number of a GbE port in an iSCSI blade. NOTE: This parameter only supports Brocade FC4-16IP blades in Brocade 48000 directors. -s server_ip Specifies the IP address in dotted-decimal form. Examples To set the IP address of an external iSNS server with an attached GbE port: switch:admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 336
2 isnscCfg See Also To register the iSNS objects: switch:admin> isnsccfg --reregister Initiated re-register of iSNS objects with iSNS server To clear the IP address of iSNS server: switch:admin> isnsccfg --clear Cleared iSNS server configuration. none 310 Fabric OS Command Reference 53-1000599- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 337
"1/0, 2/0, 3/0" specify the same ports on a 16-port/blade system. On that same system, "1/0, 16, 32" is not a valid list: even though it is legal syntax, the ports do not exist. • If no slot number is specified, all lists except user port lists will use the default slot 0. • No list type except for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 338
number, so the two notations are identical. For item list parameters, the parameter type is PT_LIST and the list type is one of those shown in the table. TABLE 16 Object Descriptions Type Grouping Description BPORTS UPORTS QUADS CHIPS MINIS SLOTS INDEX Blade Switch Blade Blade Blade Chassis - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 339
in place. Examples To terminate an open telnet connection: switch:admin> killtelnet Collecting login information....Done List of telnet sessions 13pm 1 admin0 pts/0 16.00s 192.168.130.29 6:29pm 2 admin0 pts/1 3.00s 192.168.130.29 6:31pm Enter Session Number to terminate (q to quit - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 340
. Some features of the switch and the fabric to which it is connected are optional, licensed products. Without a license installed for such products, their services are not available. A license key is a string of approximately 16 upper- and lowercase letters and numbers. Case is significant. The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 341
Domain restrictions that may be in place. Operands none Examples To display license commands: switch:admin> licensehelp licenseadd licensehelp licenseidshow licenseremove licenseshow Adds license keys to switch Print license help info Displays the system license ID Removes a license key from - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 342
Use this command to display the license ID of the system. Some features of the switch and the fabric are optional, licensed products. Without a license installed for such products, the services provided by these features are not available. For dual-domain systems, a single license enables both - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 343
come online until they equal the number of online licensed ports. This command support. Operands This command has the following operands: --release portnum Releases a license assignment from a port when the switch use in this switch: 10 port assignments are provisioned by the base switch license 5 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 344
license Ports assigned to the base switch license: 0, 1, 2, 3, 4, 5, 6, 7, 15, 16 Ports assigned to the first POD license: 8, 9, 17, 18, 19 Ports assigned to the second POD license: 10, 11, 12, 13, 14 [Note: these ports cannot be activated due to an insufficient number of installed POD licenses. Use - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 345
licenseRemove Removes the license key from the system. Synopsis licenseremove "license" Description Use this command to remove an existing license key from a switch. The existing license key must be entered exactly as shown by licenseShow, including case. When the key has been entered, use the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 346
command to display current license keys, along with a list of licensed products enabled by these keys. The message "No license installed on this switch" is displayed when no licenses are installed. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 347
is a dimensionless positive number. The FSPF protocol compares the cost of various paths between a source switch and a destination switch by adding the costs and less than 1-Gbit/sec bandwidths. Table 16 lists the link cost defaults. TABLE 17 Link Cost Defaults Link type Link cost - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 348
of the link connected to the specified port number. If cost is 0, this port will then revert to its default link cost. This operand is optional. If CR> to stop: switch:admin> linkcost 2/4 500 switch:admin> linkcost 2/4 Interface2/4 Cost switch:admin> linkcost 2/4 0 switch:admin> linkcost 2/4 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 349
login 2 login Logs in as new user. Synopsis login Description Use this command to log in to the switch with another user name and password, without first logging out from the original session. If the user was originally connected using a telnet or rlogin session, that session is left open. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 350
command is accepted as a synonym for logout, as is Ctrl-D at the beginning of a line. Operands none Examples To log out from an rlogin session: switch:admin> logout See Also login 324 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 351
Displays logical SAN zone information. The default output displays only WWNs of the zone members. Search parameters -f, -w, and -z allow searching for LSAN zones based on fabric switch which can be different than the database stored on the other FCR switches. To display the LSAN zones: switch: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 352
:68 21:00:00:20:37:18:22:55 50:05:07:65:05:84:0b:83 50:05:07:65:05:84:09:0e switch# fcrFabricShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow 326 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 353
. TABLE 18 lsDbShow Display Fields Field Description Domain lsrP earlyAccLSRs Domain number described by this LSR. A (self) keyword after the domain number indicates that LSR describes the local switch. Pointer to LSR. Number of LSRs accepted, even though they were not sufficiently spaced apart - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 354
number of the switch on the other side of the link. Port number on the local switch. Port number of the port on the other side of the link. Cost of this link. The default State Record: Link State Record pointer = 0x10053d18 lsAge = 16 reserved = 0 type = 1 328 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 355
16, flags = 0x0 LinkId = 2, out port = 16 27, rem port = LinkId = 2, out port = 32, rem port = LinkId = 2, out port = 33, port = LinkId = 2, out port = 47, rem port = 48, cost = 500, costCnt = 0, type = 1 49, cost switch has sixteen links in NB_ST_FULL state, all of them are connected to switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 356
in kilobytes. -m Specify to display memory usage in megabytes. By default, memory usage is displayed in bytes. Examples To view the memory usage: switch:admin> memshow total used Mem: 129740800 112562176 Swap: 0 0 switch:admin> memshow -m total used Mem: 123 107 Swap: 0 0 free - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 357
and external transmit and receive paths at full speed. Synopsis minicycle [--slot slotnumber][-nmegs 13, 0-14, 1-15 path 7: 1-8, 2-9, 3-10, 4-11, 5-12, 6-13, 7-14, 0-15 The port numbers are relative to the ASIC pair. This test does not route frames from one ASIC-pair to another. Ports cabled to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 358
of portLoopbackTest can determine, which components of the switch are faulty. Operands The following operands are optional: --slot slotnumber Specifies the slot number the diagnostic will operate on. The ports specified are relative to this slot number. The default is set to 0 and designed to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 359
for Bloom and Condor ASIC-based products, for which this default is off (0). -ports itemlist Specifies a list of blade ports to test. By default, all the blade 16-31 ASIC-pair 2: -ports 32-47 ASIC-pair 3: -ports 48-63 To run a functional test on slot 1 using external (SERDES) loopback: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 360
: minicycle Pass 1 of 1 Duration 0 hr, 1 min & 4 sec (0:1:4:409). passed. To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One moment please ... Path 0 ... Spinning ... Path - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 361
LESSN_STATUS_ERR MBUF_STATE_ERR MBUF_STATUS_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 362
Specifies the index of the ASIC pair within the specified blade to be displayed. If slotnumber is not provided, the default is 0 and designed to operate on fixed-port-count products. Examples To display all index 1 ASIC pair properties: switch:user> minispropshow 1 -all slot: 1, miniS: 0 [2/16 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 363
switch in the fabric: switch:admin> mscapabilityshow Switch WWN Capability Switch Name 10:00:00:60:69:20:15:71 0x0000008f "switch1"* 10:00:00:60:69:00:30:05 0x0000008f "switch2" Capability Bit Definitions: Bit 0: Basic Config Service Supported. Bit 1: Platform Management Service Supported - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 364
SAN management application to retrieve and administer the fabric and interconnect elements, such as switches. This application is located at the Fibre Channel well-known address, 0xFFFFFA. If the MS ACL is empty (default ACL 2 Add member based on its port/node WWN 3 Delete member based on its port/ - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 365
msConfigure 2 done ... See Also msCapabilityShow, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig, secPolicyShow Fabric OS Command Reference 339 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 366
restrictions that may be in place. Operands none Examples To display the MS platform database for a fabric: switch:admin> msplatshow Platform Name: [9] "first obj" Platform Type: 5 : GATEWAY Number of Associated M.A.: 1 Associated Management Addresses: [35] "http://java.sun.com/products/plugin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 367
command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry Count Exchange Status 3: 10:00:00:60:69:51:10:e6 0 0x2 msPlDBCB.peerWwn - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 368
restrictions that may be in place. Operands none Examples To clear the MS platform database: switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS Platform Service Database in the entire fabric. Would you like to continue this operation? (yes, y, no, n): [no - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 369
in the fabric boot with the MS platform service enabled. Notes By default, the MS platform service is disabled. Before issuing, run the msCapabilityShow command to verify all switches in the fabric support MS platform service; otherwise, the command fails. When FCS policy is enabled, this command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 370
entire fabric. This command deactivates the MS platform service for each switch in the fabric and commits the change to nonvolatile storage. Notes When FCS policy is enabled, this command can be issued only from the primary FCS switch. This command is supported only in AD0 and AD255 contexts. The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 371
switches; therefore, persistent across power cycles and reboots. If the "ALL" operand is used, this command attempts to disable the topology discovery service on all switches switches to support RNID ELS. Operands The optional operand is as follows: "ALL" Disables the MS topology discovery service - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 372
. Limitations Topology Discovery Management requires the attached devices which include attached switches to support RNID ELS. Operands This command has the following operand: "ALL" Enables the MS topology discovery service throughout the entire fabric. This operand is optional. Examples To - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 373
restrictions that may be in place. Operands none Examples To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. See Also msCapabilityShow, msConfigure, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 374
IPv4 or IPv6 addresses associated with the status of the system and the login session details. The login session gives details of the following: • CP/switch (or console/serial port) used to log in • The IP address of the current login session for telnet or the name of the current console - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 375
Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, all neighbor states are displayed. Examples To display information about switches directly connected to the local switch: switch:user> nbrstateshow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 376
bladed systems only, specify the slot number of the port to display, followed by a slash (/). portnumber Specify the port number to display, relative to its slot for bladed = 11 = 12 = 12 = 17 = 17 switch:admin> nbrstatsclear 1/0 switch:admin> interfaceshow 1/0 idbP = 0x10050a38 350 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 377
Interface 0 data structure: nghbP ifNo masterPort defaultCost cost = 0x1004ce68 = 0 = 0 (self) = 500 = 500 (output truncated) nCmdAcc = 0 nInvCmd = 0 nHloIn = 0 nInvHlo = 0 nLsuIn = 0 nLsaIn = 0 attHloOut = 0 nHloOut = 0 attLsuOut = 0 nLsuOut = 0 attLsaOut = 0 nLsaOut = 0 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 378
must begin with 0x or 0X; otherwise, it will be interpreted as an alias. Examples To display all the device information matching the alias "a320": switch:user> nodefind a320 Local: Local: Type Pid COS PortName NodeName SCR NL 0314d9; 3;22:00:00:04:cf:5d:dc:2d;20:00:00:04 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 379
information matching the WWN "20:00:00:e0:8b:01:ce:d3": switch:user> nodefind 20:00:00:e0:8b:01:ce:d3 Remote: Type : No Aliases: To display all the device information matching the PID "0x020eef": switch:user> nodefind 0x020eef Remote: Type Pid COS PortName NodeName NL 020eef; 3;20: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 380
Device connected to the Nx_Port, using FLOGI to login to the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSIDevice connected to the iSCSI port The second part indicates the role of the device. Currently, four roles are - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 381
To display local NS information with aliases: switch:admin> nsaliasshow { Type Pid COS PortName Name Server has 6 entries } To display local NS information with aliases with the -r option: switch:admin> nsaliasshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 382
entries } To display local NS information with aliases with the -r and -t options: switch:admin> nsaliasshow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10 Port Name: 10:00:00:60:69:00:02:d6 Device type: NPV Initiator Aliases: DeviceAlias NL 0214e2; 3;21:00:00:fa:ce:00:21 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 383
display the 24-bit Fibre Channel addresses of all devices in all switches in the fabric. If the type operand is supplied, only devices type device Other FC-PH types are displayed in the format "x ports supporting FC4 code," where x is the number of ports of a type and code is the FC-PH type code. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 384
and a list of devices for that domain number. For each device found in the devices list, the following information is displayed: Type U for unknown, N for N_Port, NL for NL_Port Pid The 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 385
Port Name: 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Device type: Physical Initiator Switch entry for 4 state rev owner known v320 0xfffc01 Device list: count 0 No entry is found! See Also nsAllShow, nsShow, switchShow Fabric OS Command Reference 359 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 386
Local Name Server The nsAllShow command displays information from all switches. Each line of output displays: Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. PortName Device port World Wide Name (WWN - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 387
connected to the Nx_Port, using FLOGI to login to the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSI Device connected to the iSCSI port The second part indicates the role of the device. Currently, four roles are - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 388
Device Shared in Other AD: No Redirect: No The Local Name Server has 2 entries } See Also To display local name server information with "-r" and "-t" options. switch:admin> nsshow -r -t { Type Pid COS PortName NodeName SCR N 010100; 3;21:00:00:e0:8b:13:08:10;20:00:00:e0:8b:13:08:10 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 389
The 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device's port World Wide Name (WWN) any of the following information (the switch automatically registers SCSI inquiry data for FCP target devices): • FC4 supported • IP address (node) • IPA - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 390
members To display information about all the online devices zoned with the given WWN: switch:admin> nszonemember 10:00:00:00:c8:23:0b:ad 3 local zoned members members To display each local device's online zoned device data: switch:admin> nszonemember -a Port: 4 Pid: 0xb00400 Aliases: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 391
Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Pid: 0xba1ae4 Aliases: trimm100a_2 To display all the unzoned devices in the fabric: switch:admin> nszonemember -u Pid: 0xb01ea9; Aliases: trimm32b_1 Pid: 0xb01eaa; Aliases: trimm32b_2 Pid: 0xb01eab; Aliases: trimm32b_3 Pid: 0xb01eac; Aliases - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 392
can be changed locally on any switch. For the password database to be distributed to other switches in the fabric, the switches must be configured to accept the password database with the fddCfg command. The password database is distributed manually with the distribute command. The execution - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 393
for the admin account while logged in as admin: switch:admin> passwd Changing password for admin Enter new password: Re-type new password: Password changed. Saving password to stable storage. Password saved to stable storage successfully. Diagnostics The system may generate one or more of the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 394
less than the minimum required number of numeric characters. Insufficient number of punctuation characters You have entered a password that contains less then the minimum required number of punctuation characters. Password matches one of the previous passwords The password you entered matches one of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 395
is approaching is displayed when the user logs in. The number of days prior to password expiration during which warnings commence is a configurable parameter. Password expiration does not disable or lock out the account. The password expiration policy is enforced across all user accounts except the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 396
each user on each switch instance. The counters for password configuration parameters. --set Configures a specified password policy. The following arguments are supported: -lowercase value Specifies the minimum number of lowercase alphabetic characters that must occur in the password. The default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 397
default value to 0. -lockoutthreshold value Specifies the number of times a user can specify an incorrect password during login before the account is locked. The number .lockoutduration" duration. The particular account is unlocked manually using userconfig --change account name-u (requires root - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 398
, admin lockout policy is disabled. --setdefault Resets all password policies to their default values. --help Displays command usage. Examples To display the current password configuration parameters: switch:admin> passwdcfg --showall passwdcfg.minlength: 8 passwdcfg.lowercase: 0 passwdcfg - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 399
-maxpasswordage value must be between 0 and 999. warning value out of range The -warning value must be between 0 and 999. invalid password expiration specification The -minpasswordage value or -warning value must be less than or equal to -maxpasswordage value when -maxpasswordage value is nonzero - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 400
). For each hop, the routing information output includes the following: Hop The hop number. The local switch is hop 0. In Port The port or area from which the switch receives frames. For hop 0, this is src_portnumber. For bladed systems, this is specified as the port index; otherwise, it is the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 401
command uses a special frame, the pathInfo frame, that is sent hop-by-hop from the source switch to the destination switch. In order to prevent such a frame to loop forever if an error occurs, a maximum number of hops for the frame to traverse is enforced. The hop count includes all hops in the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 402
destination), as a full route, or as an part described by output ports or areas. Switches running pre 5.2 firmware cannot use ports > 256 as a destination port on a remote switch The default is embedded port (-1). For bladed number of hops that the pathInfo frame is allowed to traverse; default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 403
; default is 10 seconds. Examples To display basic path information to a specific domain, using the command line (non-interactive mode): switch:admin 36 76 0 0 B/s (64s) 5 5 5 5 Txcrdz (1s) 0 - 0 - Txcrdz (64s) 0 - 0 - F/s (1s) 1 1 0 0 F/s (64s) 0 0 0 0 Words - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 404
2 pathInfo Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) See Also portStatsShow, switchShow 378 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 405
the latest panic dump file available on the switch. If a panic dump file is specified the following optional operands: panic_dump_file Specify the full path name of a panic dump file * WatchDogRegister=0x0 Section=Startup time: Tue Dec 3 16:06:11 UTC 2002 Kernel= 2.4.19 Fabric OS= v4 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 406
number is displayed. The monitor number is provided for manipulation of these performance monitors. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported : slotnumber For bladed systems only, this operand specifies the slot number of the port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 407
when using commas. Examples To add an end-to-end monitor to blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number 0 added. See Also perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 408
displayed, if one is specified. All valid monitor numbers and user-defined aliases can be displayed with the perfMonitorShow command. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 409
. The maximum number of filters is eight per port including user-defined filters, read filters, write filters, read/write filters, SCSI frame monitor, and IP frame monitor. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 410
. The maximum number of filters is eight per port, including user-defined filters, read filters, write filters, read/write filters, SCSI frame monitor, and IP frame monitor. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 411
. The maximum number of filters is eight per port, including user-defined filters, read filters, write filters, read/write filters, SCSI frame monitor, and IP frame monitor. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 412
displayed, if one was specified. All valid monitor numbers and user-defined aliases can be retrieved with the perfMonitorShow command. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 413
, in order to include spaces. This operand is optional. By default, the alias is an empty string. Examples To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 414
numbers and user-defined aliases can be retrieved with the perfMonitorShow command. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported The default alias is "SCSI_Write". Examples To add an SCSI Write command monitor to a port: switch:admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 415
to-end and filter configuration settings of performance monitoring from nonvolatile memory. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 416
. Any configuration changes that were not saved are lost using the perfCfgRestore command. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 417
power cycles. The following limitation applies to monitors saved to flash memory: • 16 EE monitors • 16 filter monitors • A total number of 512 monitors per switch memory. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/ - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 418
requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual slotnumber For bladed systems only, this operand specifies the slot number of the port: switch:admin> perfclearalpacrc 2/15 0x59 CRC error count at ALPA 0x59 on port 31 is cleared. switch:admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 419
all filter-based monitors clearing. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on slot for bladed systems. Use switchShow for a list of valid ports. monitorId Specify the monitor number to clear. Monitor numbers are defined when - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 420
requires a Brocade Advanced Performance Monitoring license. This command is not supported on For bladed systems only, this operand specifies the slot number of the or all such monitors: switch:admin> perfdeleemonitor 7/2 5 End-to-End monitor number 5 deleted switch:admin> perfdeleemonitor 7/2 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 421
[monitorid] Description Use this command to delete a filter-based performance monitor from a port, or all such monitors associated with a port. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 422
related to performance monitoring: switch:admin> perfhelp perfAddEEMonitor perfAddIPMonitor count Delete an end-to-end monitor on port Delete filter-based monitor Clear end-to-end/filter-based/ISL monitors Show end-to-end/filter-based/ISL monitors Set overall mask for E-to-E monitors Get ALPA - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 423
n): [no] y To clear statistics counters for a filter-based monitor: switch:admin> perfmonitorclear --class FLT 1/2 4 Filter-based monitor number 4 counters are cleared switch:admin> perfmonitorclear --class FLT 1/2 This will clear ALL filter-based monitors' counters on port 2, continue? (yes, y, no - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 424
2 perfMonitorClear To clear statistics counters for an ISL monitor: switch:admin> perfmonitorclear --class ISL 1 This will clear ISL monitor on port 1, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 425
classes include end-to-end monitors (EE), filter-based monitors (FLT), and Inter-Switch Link monitors (ISL). ISL monitors are automatically activated is specified, the command displays: Tx_count 64-bit cumulative ISL transmit count for the whole ISL Num_ports Number of ports in this ISL (one - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 426
2 perfMonitorShow Num_domains Domain_count Total number of domains being monitored 64-bit cumulative transmit counter for each individual domain Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 427
53m 0 52m 0 52m 0 52m 0 52m 0 To display cumulative filter monitor information on a port: switch:admin> perfmonitorshow --class FLT 2/5 There are 7 filter-based monitors defined on port 21. KEY ALIAS OWNER_APP FRAME_COUNT OWNER_IP_ADDR 0 SCSI_Frame TELNET 0x00000000002c2229 N/A 1 SCSI_WR - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 428
of ports in this ISL: 2 Domain 97: 110379 Domain 98: 13965 Domain 99: 1337982 To display EE moniors configured on port number 0: switch:admin> perfmonitorshow --class EE 0 There is 1 end-to-end monitor defined on port 0. KEY SID DID OWNER_APP TX_COUNT 0 0x112233 0x223344 TELNET - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 429
the AL_PA ID address field must be masked together, to support the FC4-48 blade. On this blade, one bit of the AL_PA ID address field is used with the Area ID address field to identify the upper 32 ports. For example, ports 128 and 256 may be addressed on Domain ID "dd" with Area ID - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 430
the destination ID mask, in quotation marks, in dd:aa:pp format. Examples To set the overall mask for end-to-end monitors on a port: switch:admin> perfsetporteemask 1/6 "00:00:00" "ff:ff:ff" "00:ff:ff" "ff:00:00" Changing EE mask for this port will cause ALL EE monitors - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 431
64-bit counter. The CRC count value is displayed in hexadecimal. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on the Brocade For bladed systems only, this operand specifies the slot number of on a port: switch:admin> perfshowalpacrc - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 432
requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC operands: slotnumber For bladed systems only, this operand specifies the slot number of the port on EE monitors configured on the switch port 0: switch:admin> perfshoweemonitor 0 There is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 433
6m 0 52m 4.6m 0 52m 0 To display cumulative information from EE monitors on a port: switch:admin> perfshoweemonitor 4/5 There are 7 end-to-end monitor(s) defined on port 53. KEY SID 192.168.169.40 Some platforms do not support counting CRC errors, and therefore the CRC error - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 434
a sorted order based on the data rate of each flow. 2. In Fabric Mode, Top Talker measures the top "n" bandwidth using flows on a given switch. Top Talker operands are supported: [slot]/ On bladed systems only, specify the slot number, followed by a slash (/). port Specifies the port number. This - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 435
. --show Displays top talking flows on the switch, for a given domain id. dom dom_id Specifies the domain ID for the flow display. number of top talking flows Specifies "n" top talking flows. Valid values are between 1 and 32. If a value >32 is entered, Top Talker will display counters for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 436
2 PerfTTmon 0xa905ef 0xa909d5 0xa05200 0xa05200 6.830 6.772 To delete the Fabric Mode Top Talker: Switch:admin> perfttmon --del fabricmode See Also None 410 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 437
is subject to Admin Domain restrictions that may be in place. Operands none Examples To create PKI objects: switch:admin> pkicreate Installing Private Key and Csr... Switch key pair and CSR generated... Installing Root Certificate... See Also If PKI objects already exist, the following message - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 438
key infrastructure (PKI) objects. Synopsis pkiremove Description Use this command to remove PKI objects including the switch private key, private key pass-phrase, CSR, root certificate, and switch certificate. The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 439
of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To view PKI objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist CSR : Exist Certificate : Empty Root Certificate: Exist See Also pkiCreate, pkiRemove Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 440
option --create --delete --show type ike ipsec number Specifies the action to take. Actions include: 32, and ALL with the --show option. Optional Operands -enc method 3DES AES-128 AES-256 -auth algorithm SHA-1 MD5 AES-XCBC -pfs value -dh group Specifies the encryption algorithm. The default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 441
lifetime in seconds. A new key is renegotiated before seconds expires. seconds must be between 28800 to 250000000 or 0. The default is 28800. Examples To create a new policy: switch:admin> policy --create ike 10 -enc 3des -auth md5 The following policy has been set: IKE policy 10 Authentication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 442
10 Authentication Algorithm: SHA-1 Encryption: AES-128 Perfect Forward Secrecy: 0 Diffie-Hellman Group: 1 SA Life (seconds): 28800 To delete a policy: switch:admin> policy ike --delete 10 The policy has been successfully deleted. See Also portCfg, portCfgShow, portShow 416 Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 443
the port to display, followed by a slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA 0xe2 public 0xe4 type public - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 444
full bandwidth (depending on the port configuration). If the number of Buffer Usage is less than the number of Needed Buffers, the port is operating in the buffer limited mode. Link Distance For L0 (not in long distance mode), the command displays the fixed distance based switch. LD mode supports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 445
to display, followed by a slash (/). Specifies the number of a port associated with the port group, relative to its slot for bladed systems. Use switchShow for a list of valid ports. Examples To display the port buffer information for a port: switch:admin> portbuffershow 17 User Port Lx Max/Resv - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 446
number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, information for all ports is displayed. Ports that support this case portcamshow entries will look like below: switch:user> portcamshow 7/39 Area SID used DID - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 447
CAM utilization for all ports on a switch: switch:user> portcamshow Ports of Slot 9 Port SID used DID used SID free DID free 0 0 0 64 512 1 0 0 64 512 2 0 0 64 512 3 0 0 64 512 4 0 0 64 512 5 0 0 64 512 6 0 0 64 512 7 0 0 64 512 8 0 0 63 511 9 0 0 63 511 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 448
- Create or modify a tunnel with VLAN tagging and Class of Service (CoS). • Configure IP interfaces on the GbE port. • supported by this command may require a Brocade license. Operands This command supports the following port options: slot For bladed systems only, specifies the slot number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 449
port. This feature requires a Brocade FCIP license. The syntax for supported value is 80. -M Turns on default VC QoS mapping in the specified tunnel. Default is off. There are two ways of prioritizing network traffic over FCIP tunnels: Differentiated Services (DSCP) and Layer 2 Class of Service - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 450
on secure tunnels. Only a single route is supported on an interface with a secure tunnel. -v vlan_id Creates an FCIP tunnel with VLAN Tagging and Class of Service (CoS). Specify a vlan_id in the range between 1 and 4094. There is no default. If any other VLAN option is specified, this must - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 451
tunnel. Values are 1 to 16; default is 8. If tape pipelining is enabled, the default value is calculated based on the minimum retransmit time 1p, for the FCIP control connection. Range is 0-7. Default is 0. -P L2 CoS Specifies the PL2 Class of Service/Priority, as defined by IEEE 802.1p, for the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 452
QoS map configuration file. Delete QoS mappings before downgrading to pre-v6.0.0 firmware versions that do not support QoS mapping. It removes the file from the config flash memory only. The file is automatically reset to defaults if later used or modified. vc_num When modifying the VC QoS map - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 453
the remote switch, you can define destination routes on an interface. A maximum of 32 routes per GbE port are supported. IPv6 addresses are supported on platforms the link metric associated with the route. Valid values are 0-255. The default value is 0. A low value encourages the use of the route, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 454
with this one. By default, RSCN suppression is disabled troubleshooting common FC end-to-end communication problems Brocade 48000 directors with FR4-18i bladesconnected by Fibre Channel ISLs. FastrWrite mitigateslatency effects on SCSI writes, and improve throughputover a high-latency link. The blade - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 455
. L2 CoS Specifies L2 Class of Service/Priority, as defined by IEEE 802. Default is 0.0.0.0. ficon tunnelId Use this command to enable or disable FICON emulationin an FCIP tunnel and modify associated parameters onan FCIP tunnel on a 'virtual' E Port. This command is supported only on a Brocade - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 456
occurs as part of a supported with the config and delete options. -a |--wrtMaxPipe value ' Defines the maximum number based upon the typical tape channel program that requires optimum performance. The default value is 32. the range is 1-100. -b |--rdMaxPipe value Defines the maximum number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 457
hosts (channels) attached at the opposite side. The default value is 16. The range is 1-32. -e |--wrtTimer value Defines a time limit for pipeline . The default value is 3 (3000000 bytes) The Range is 1 Mb-5 Mb. -o |--oxidBase value Defines the base value of an entry pool of 256 OXIDs supplied - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 458
default is FFFFFFFF. Specifies post trigger percentage value. The range is 0 to 100 Default is 5. Specifies the number of records. The range is 0 to 1,677,721. The default to default values: switch:admin> portcfg fciptunnel ge1 qosmap 1 -default To create an FCIP tunnel with VLAN tagging: switch: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 459
switch:admin> portcfg ipif 8/ge0 create 2000::800:3333:1234/64 Operation Succeeded To create a static IP route using IPv4: switch:admin> portcfg iproute ge0 create 172.16 Tape Write Pipelining Emulation features enabled using all default parameter arguments: switch:admin> portcfg ficon ge0 1 -x 1 -w - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 460
2 portCfg 434 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 461
Changes made by this command are persistent across switch reboots and power cycles. Operands When invoked without operands, this command displays the usage. The following operands are supported: slotnumber For bladed systems only, specify the slot number of the port to be configured, followed by - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 462
to display, followed by a slash (/). portnumber Specify the number of the port to be returned to default values, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To reset a port to factory defaults: switch:admin> portcfgdefault 1/3 To reset a GbE port to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 463
capability is enabled by default unless this command is used switch reboots or power cycles. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 464
preferred domain ID is configurable. The preferred domain ID is used by the EX_Port's front phantom domain to request a domain ID from the principal switch. The domain ID received becomes the subsequent preferred domain ID, which is persistent and is displayed. Notes The fabric ID must be the same - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 465
the edge switch specifies in the ELP request. If the state is "Not OK", the R_A_TOV and E_D_TOV display "Not Applicable". By default, all EX_Ports be posted, and the command will fail. Valid values are as follows: 0 Brocade Native mode. 1 McDATA Open Fabric mode. 2 McDATA Fabric mode. Note that - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 466
> portcfgexport 2/0 Port 2/0 info Admin: enabled State: OK Pid format: core(N) Operate mode: Brocade Native Edge Fabric ID: 16 Front Domain ID: 160 Front WWN: 50:06:06:9e:20:9f:ce:10 Principal Switch: 7 principal WWN: 10:00:00:60:69:c0:05:8a Fabric Parameters: Auto Negotiate - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 467
reboots or power cycles. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). portnumber - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 468
This feature is not backward compatible with firmware versions that do not support it. Notes The long distance modes L0.5, L1, and L2 are no longer supported in v5.3.0 and above. Changes made by portCfgISLMode are persistent across switch reboots and power cycles. The execution of this command is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 469
slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. mode Specify 1 to enable ISL R_RDY mode. Specify 0 to disable ISL R_RDY mode. To enable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 1 ISL R_RDY - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 470
] Description Use this command to allocate enough full size frame buffers on a particular port to support a long distance link up to 500 Km. The port can only be used as an E_Port. Changes made by this command are persistent across switch reboots and power cycles. This configuration can be cleared - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 471
total of 250 full-size frame buffers requires a Brocade Extended Fabrics supported in v5.3.0 and above. A long-distance link also can be configured to be part firmware versions that do not support it. Ctrl-D will cancel the configuration update. Examples To configure a switch port 63 to support - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 472
2 portCfgLongDistance See Also Lli: 9 Proc_rqrd: 0 Timed_out: 0 Rx_flushed: 0 Tx_unavail: 0 Free_buffer: 0 Overrun: 0 Suspended: 0 Parity_err: 0 2_parity_err: 0 CMI_bus_err: 0 Loss_of_sig: 9 Protocol_err: 0 Invalid_word: 0 Invalid_crc: 0 Delim_err: 0 Address_err: 0 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 473
default value of 0 is used. Private devices are supported only on Brocade 3250, 3850, and 3900 and directors with FC2-16 and FC2-16 blades. For other switches and blade 0 to configure the L_Port as a full-duplex L_Port. This operand is optional; if omitted, the default value of 0 is used. If used - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 474
2 portCfgLPort where AN:AutoNegotiate, ..:OFF, ??:INVALID. To display the L_Port conditions: switch:admin> portcfglport [output from other slots suppressed] Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Locked L_Port ON Private L_Port Locked Loop HD Loop - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 475
come online if it is connected to an enterprise fabric switch that supports NPIV. Notes NPIV capability should be enabled on the ports enable or disable as N_Port mode Displays current agmode setting for the switch. The default value for mode is 0 (disabled) and if the value 1 (enabled). - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 476
an F_Port only. By default, NPIV is enabled for all Condor ASIC-based ports and disabled for all Bloom ASIC-based ports. The following conditions must be met for a switch port to respond to NPIV requests from an NPIV device: NPIV capable: NPIV capability is a switch blade or port attribute that - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 477
Persistent Disable NPIV capability .. .. .. ON EX Port where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 See Also To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 configure, portCfgDefault, portCfgShow Fabric OS Command Reference 451 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 478
disabled ports remain disabled across power cycles, switch reboots, and switch enables. By default, a port is enabled bladed systems only, specify the slot number of the port to configure, followed by a slash (/). portnumber Specify a port number to configure, relative to its slot for bladed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 479
enabled ports remain enabled across power cycles, switch reboots, and switch enables. By default, a port is enabled bladed systems only, specify the slot number of the port to configure, followed by a slash (/). portnumber Specify a port number to configure, relative to its slot for bladed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 480
Service (AN/QoS) on a port, to set or reset the ingress ratelimit for the port, and to set the default Brocade switch link (ISL). Qos configuration is persistent across system reboots. Operands This command has the following operands: --default Applies the default in Mbps. Supported values for -- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 481
--disable 3/15 To set the ingress rate limit on a port to 2 Gbps: switch:admin> portcfgqos --setratelimit 3/15 2000 To set the default Qos configuration on a port: switch:admin> portcfgqos --default 3/15 portCfg, portCmd, portShow, switchShow, configure : PortCfgQos 2 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 482
this command displays port configuration settings for all ports on a switch, except gigabit Ethernet (GbE) ports. Additionally, use this command physical address (AL_PA) offset. Displays (...)/OFF when the AL_PA Offset is 0x0 (default). Displays ON when AL_PA Offset is 0x13. This value is set by the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 483
Fastwrite is disabled by default. This value is set by the portCfg fastwrite command. The execution of this command is subject to Admin Domain restrictions that may be in place. This command supports the following port options: slot For bladed systems only, specifies the slot number of the port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 484
supported. iproute Displays the IP route on the specified GbE port. IPv6 addresses are supported mapping. Examples To display the port configuration settings on a chassis-based system: switch:admin> portcfgshow Ports of Slot 2 0 1 2 3 .. .. .. ON Ports of Slot 2 16 17 18 19 20 21 22 23 24 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 485
ON ON ON ON ON ON ON ON ON where AN:AutoNegotiate, ..:OFF, ??:INVALID, To display the configuration settings for a single port: switch:admin> portcfgshow 2/16 Area Number: 144 Speed Level: AUTO AL_PA Offset 13: OFF Trunk Port ON Long Distance OFF VC Link Init OFF Locked L_Port OFF - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 486
2 portCfgShow 460 0 192.168.60.100 255.255.255.0 1500 1 192.168.60.101 255.255.255.0 2348 2 192.168.60.102 255.255.255.0 1260 3 192.168.60.103 255.255.255.0 1700 4 192.168.60.104 255.255.255.0 1400 5 192.168.60.105 255.255.255.0 2000 6 192.168.60.106 255.255.255.0 1300 7 192.168.60. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 487
15 63 0 Vlantag configuration Display of VLAN tagging on a GbE port. Refer to the portCfg help page for an explanation of the displayed parameters. switch: admin> portcfgshow vlantag 8/ge0 Port: 8/ge0 IpIfAddress VlanId L2 CoS Dest IP Address Flags 192.168.10.1 100 7 192.168.10.1 App - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 488
in nonvolatile memory and is persistent across switch reboots or power cycles. Notes This configuration cannot be bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). portnumber Specify a port number to be configured, relative to its slot for bladed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 489
Brocade number to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. mode Specify 1 to enable this port for trunking. Specify 0 to disable the port from being trunked. This operand is required. Examples To enable a port for trunking: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 490
negotiated values indicated by "(N)" next to them. The negotiated values are what the edge switch specifies in the ELP request. If the state is "Not OK", the R_A_TOV and E_D_TOV display "Not Applicable". By default, all VEX_Ports are auto-ELP enabled. If the Fabric Parameter attribute value is "User - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 491
be posted, and the command will fail. Valid values are as follows: 0 Brocade Native mode. 1 McDATA Open Fabric mode. 2 McDATA Fabric mode. Note that port 2/16: switch:admin> portcfgvexport 2/16 Port 2/16 info Admin: enabled State: OK Pid format: core(N) Edge Fabric ID: 16 Front Domain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 492
N/A To set the fabric ID of port 2/21 to 5 and the port ID format to core: switch:admin> portcfgvexport 2/21 -f 5 -p 1 To configure port 2/20 to be an VEX_Port and set the fabric ID to 4: switch:admin> portcfgvexport 2/20 -a 1 -f 4 To disable fabric parameter negotiation on port 2/20 of an VEX_Port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 493
is supported on the Brocade FR4-18i not supported, if bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). ge port Specifies the port number of the GbE port on the blade supported. -d dst_ip Specifies the destination supported TCP port number for the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 494
sized data buffer is used based on the outgoing IP interface Service Specifies Class of Service/Priority, as defined by IEEE 802.1p. Values must be in the range between 0 and 7. The default The number of TCP retransmits. This number . Note: There is limited support for black hole PMTU detection. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 495
to which to target the ping request. IPv6 addresses are supported. -n num_requests Specifies the number of ping requests. The default is 4. This operand is optional. -q service_type Specifies the type of service in the ping request. The default is 0 and service_type must be an integer from 0 to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 496
destination IP address with maximum wait_time specified: switch:admin> portcmd --ping 12/ge0 -s 2007:7:30:32:227:138:10:120 -d \ 2007:7:30:32:227:77:0:60 -w 29000 Pinging 2007:7:30:32:227:77:0:60 from ip interface 2007:7:30:32:227:138:10:120 on 12/ge0 with 64 bytes of data Reply from 2007:7:30 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 497
Specify the verbose level to be set for port modules; valid values are 1 to 5. Examples To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow Fabric OS Command Reference 471 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 498
, followed by a slash (/). portnumber Specify a port number to be disabled, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To disable a port: switch:admin> portdisable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portEnable - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 499
sent to indicate a state transition: RSCN, SNMP trap, Web pop-up window. This command is rejected if the port's switch is disabled, the port's blade is not fully enabled (faulted, powered off, or disabled), or if the port itself is persistently disabled. Notes The front panel LED of an enabled and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 500
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display error counters for ports on a switch: switch:admin> porterrshow frames enc crc too too bad enc disc link loss loss frjt fbsy tx rx in err shrt long eof out c3 fail - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 501
Admin Domain restrictions that may be in place. Operands none Examples To display the port status for all ports in the switch: switch:user> portflagsshow Slot Port SNMP Physical Flags 1 0 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 1 1 Online In_Sync PRESENT ACTIVE - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 502
that the command has finished and exited. You can enable the current switch (using the switchEnable command) to set the ATTN LEDs back to command has the following operands: -npass count Specify the number of times to perform this test. The default value is 10. -ports itemlist Specify a list of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 503
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow Fabric OS Command Reference 477 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 504
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize 478 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 505
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands None. Examples To display the port log facility: switch:admin> portlogdisable See Also portLogEnable Fabric OS Command Reference 479 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 506
full explanation of the information displayed by this command, refer to the Fabric OS Administrator's Guide. number of lines to be displayed. Only the most recent count entries are displayed. This operand is optional. saved Specify a nonzero value to display the saved port log from the last switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 507
firmware, which can save up to 8,192 entries. Refer to portLogConfigShow to display the current port log size. Once the log is full, the newest log entries delete the oldest log entries. Port logs capture switch-to-device, device-to-switch, switch-to-switch, some device-to-device1, and control - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 508
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands None. Examples To enable the port log facility. switch:admin> portlogenable See Also portLogDisable 482 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 509
0 10 Rx1 0 11 Rx2 0 12 Rx3 0 13 stats 0 14 scn 0 15 pstate 0 16 reject 0 17 busy 0 18 ctin 0 19 ctout 0 20 errlog 0 21 loopscn 0 22 create 0 29 read 0 30 write 0 48 cmd 0 49 event 0 50 msg 0 51 switch 0 52 ficonq 0 (output truncated) See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 510
Flogs and EE (end-to-end) credit for PLOGIs. df_sz The default frame size for this login. cos Class of Services supported. This can be a combination of the following bits: 4 Class 2 is supported. 8 Class 3 is supported. Further information about each login is displayed after these columns - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 511
that may be in place. Operands This command has the following operand: 0|1 Specify 0 to clear or 1 to set the debug_pdisc_flag. Examples To set the debug_pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See Also none Fabric OS Command Reference 485 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 512
facility. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the port log: switch:admin> portlogreset See Also none 486 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 513
Operands This command has the following operand: num_entries Specifies the number of entries to which portlog needs to be resized. The valid range of values is 32,768 to 65,536 for Brocade 48000 Director and Brocade 7500 Switch, and 8,192 to 16,384 for all others. Examples To resize the portlog - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 514
switch firmware, which can save up to 32,768 entries. Refer to portLogConfigShow to display the current port log size. Once the log is full in milliseconds. The clock resolution is 16 milliseconds. Task Displays the name of the ctin A CT based request is received ctout A CT based response is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 515
FC frame payload Interswitch name server query RSCN Allocate an exchange Free an exchange Exchange error Exchange state Frame payload Displays the port number that logged the event. Defined by the event. Displays a value defined by the event as follows: I/O control command code Frame payload size - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 516
-PH reject reason FC-PH busy reason Argument 0 is divided into two 16-bit fields: [A] a bit map indicating whether subsequent args are valid (0001 means argument 1 is valid, 0003 means arguments 1 and 2 are valid). [B] the CT-based service command code. Argument 1 is the first word of the CT payload - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 517
portLogShow 2 Codes used in various fields are as follows: state 1 Online 2 Offline 3 Testing 4 Faulty 5 E_Port 6 F_Port 7 Segmented pstate AC Active State LR1 Link Reset: LR Transmit State LR2 Link Reset: LR Receive State LR3 Link Reset: LRR Receive State LF1 Link - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 518
a full explanation of the information displayed by this command, refer to the Fabric OS Administrator's Guide. The number of lines to display. Only the most recent count entries are displayed. This operand is optional. saved Specify a nonzero value to display the saved port log from the last switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 519
restrictions that may be in place. Operands This command has the following operands: portid Specify the port number of the port to display. Examples To display a port log for port 14: switch:user> portlogshowport 14 time task event port cmd args 08:35:28.483 tFabric scn 14 0 08 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 520
values corresponding to different log types can be obtained by running portLogEventShow. Examples To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable 494 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 521
be enabled. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable Fabric OS Command Reference 495 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 522
number][-nframes count][-lb_mode mode][-spd_mode mode] [-ports itemlist] Description Use this command to verify the functional operation of the switch slot number Specify the slot number on which the diagnostic will operate. The ports specified will be relative to this slot number. The default is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 523
to test. By default, all of the blade ports in the specified slot (--slot) are used. See itemList for more information. Examples To run a functional test of a connection: switch:admin> portloopbacktest -ports 1/10-1/20 -nframes 1 -lb_mode 1 Running Port Loopback Test .... passed. Diagnostics - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 524
2 portLoopbackTest ERRSTAT INIT PORTDIED STATS TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList 498 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 525
blade or another switch (i.e. another blade has an E_Port leading to another switch Specifies the port number of the mirror switch use the portCfgShow command. The port mirroring feature is only supported on the following platforms: Brocade 4100, Brocade 4900, Brocade 7500, and Brocade - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 526
a source and a destination. slotnumber For bladed systems only, specify the slot number of the port on which the mirror DestID cannot both be 0x000000. Examples To configure a port as a mirror port: switch:admin> portcfg portmirror 2/1 --enable Please confirm enable of Mirror Port: 17 (Y,y,N,n): - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 527
To display port mirror connections: switch:admin> portmirror --show Number of mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled See Also portCfgShow portMirror 2 Fabric OS Command Reference 501 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 528
name persists across reboots and power cycles. It is not number to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. name Specify a port name. The port name is a character string up to 32 switch:admin> portname 1/3, "Tape drive 8" switch:admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 529
switch. Data displays in 8 or 16 columns, one column per port plus one column that displays the total for these ports. Results display every second or over the specified interval, until Enter, Ctrl-c, or Ctrl-d is pressed. This command displays the number of bytes received plus the number Default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 530
area number of a device (or set of looped devices) attached to the local switch. firmware. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 531
portRouteShow 2 external unicast routing table: 1: 0x4 (vc=3) 2: 0x10000 (vc=0) internal unicast routing table: 60: 0x8000 (vc=2) 63: 0x1000 (vc=5) broadcast routing table: 0x10000 See Also bcastShow, fabricShow, switchShow, topologyShow, uRouteShow Fabric OS Command Reference 505 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 532
be in place. In an AD context, if one of the L-ports or NPIV ports is a part of the current AD, the complete device information attached to port will be shown in the output. logins have been accepted. portType The port's type and revision numbers. 506 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 533
. Diag_Flt Port failed diagnostics. Lock_Ref Locking to the reference signal. portScn The port's last State Change Notification. port generation number The ports generation number for the last offline state change. portId The port's 24-bit port ID. portIfId The user port's interface ID - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 534
DH-CHAP is the only authentication type supported on EX_ports. DH Group Displays DH group fabric's primary WWN If the EX_Port is connected to an edge switch with FCS policy enforcement, The WWN of the primary FCS interrupt statistics: Interrupts Total number of interrupts. Unknown Interrupts - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 535
LIP received. The execution of this command is subject to Admin Domain restrictions that may be in place. This command supports the following port options: slot For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). [ge]port Specify the port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 536
Block. Displays 1250 memory in 256 byte increments: ! for next. a debug tool for developers and support (not intended for customer use). For the state of a port: switch:admin> portshow 3/15 portName: Online portPhys: 6 In_Sync portScn: 64 Segmented port generation number: 12 portId: 022f00 portIfId: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 537
part of other ADs: No To view xlate domains, you must be running a Brocade 7500 or 48000 with a FC4-18i blade. Note that the Front Domain ID is what is shown: switch : 6 In_Sync portScn: 1 Online Trunk master port port generation number: 160 portId: 965400 portIfId: 43820005 portWwn: 20:54:00: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 538
portShow CMI_bus_err: 0 Port part of other ADs: No To display IPv4 interfaces on a GbE port: switch:admin> portshow ipif 10/ 255.0 192.168.255.27 0 Interface, 172.16.123.231 255.255.0.0 192.168.255.25 1 To display ISCSI Port WWN and Sessions: switch:admin> portshow iscsi 2/ge0 GE Port 2/ge0 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 539
portShow 2 switch:admin> portshow fciptunnel 9/ge0 0 -params Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 540
Pre-Shared Key testingFIPSandIPSec To display the performance information on an FCIP tunnel: switch:admin> portshow fciptunnel 9/ge0 0 -perf Slot: 9 Port: ge0 Tunnel compressed Bytes 2065 Bps 30s avg, 3695 Bps lifetime avg 1.64 compression ratio FC control traffic TCP connection: Local 10.10.9.100 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 541
Bps lifetime avg IKE Policy 1 IPSec Policy 1 Pre-Shared Key testingFIPSandIPSec To display the connection IPSec information on an FCIP tunnel on a GbE port: switch:admin> portshow fciptunnel 9/ge0 -ipsec Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 542
.20 00:05:1e:37:0f:a5 Permanent Resolved To display the FC data path credit data: switch:admin> portshow fciptunnel 9/ge0 0 -credits Slot: 9 Port: ge0 Tunnel ID 0 Remote IP tuning Credit processing: ip_api_data_credit_target = 32 ip_api_data_credit_ratio = 80 ip_api_credit_time = 15 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 543
47 4 12 51 4 13 55 4 14 59 4 15 63 0 To display FICON EPCB for GE port 0 tunnel id 1 with post display clearing of relevant statistics: switch:admin> portshow ficon ge0 1 -epcb -clear To display a list of discovered devices and selected path and status information on each. Get the adrs from this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 544
2 portShow See Also authUtil, portCfg, portCfgLongDistance, portLoginShow, portName, switchShow 518 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 545
the 64-bit hardware statistics for a port. Synopsis portstats64show [slotnumber/]portnumber Description Use this command to display the following hardware statistics for a port. Two integers are reported for most values. In such cases, the top word is the most significant. stat64_wtx Number of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 546
followed by a slash (/). portnumber Specify a port number to be displayed, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To display the 64-bit hardware statistics for a port: switch:user> portstats64show 4/15 stat64_wtx 0 top_int : 4-byte - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 547
portStats64Show 2 er64_enc_out 0 top_int : Encoding error outside of frames 9131157 bottom_int : Encoding error outside of frames er64_disc_c3 0 top_int : Class 3 frames discarded 0 bottom_int : Class 3 frames discarded stat64_rateTxFrame 17 Tx frame rate (fr/sec) stat64_rateRxFrame 17 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 548
quad, including ALPA-based CRC monitor, End-to-End monitor, and Filter-based performance monitor statistics. Inter-Switch Link (ISL) number to be cleared, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To clear the statistics for a port: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 549
counters. Some counters are platform and port specific and display only with those platforms and ports. All statistics have a maximum 32-bit value of 4,294,967,295. stat_wtx 4-byte words transmitted. stat_wrx 4-byte words received. stat_ftx Frames transmitted. stat_frx Frames received - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 550
. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to be displayed, followed by a slash To display the basic set of statistics for a port: switch:admin> portstatsshow 13 stat_wtx 0 stat_wrx 0 stat_ftx 0 stat_frx - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 551
the tenancy number of times NL has the tenancy zero tenancy To display GbE port statistics for slot 8 and GbE port 1: switch:admin> portstatsshow ge 8/ge1 ge_stat_tx_frms ge_stat_tx_octets ge_stat_tx_ucast_frms ge_stat_tx_mcast_frms ge_stat_tx_bcast_frms ge_stat_tx_vlan_frms ge_stat_tx_pause_frms - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 552
2 portStatsShow ip_out_octets ip_out_octets ip_out_pkts ip_out_ucast_pkts ip_out_bcast_pkts ip_out_mcast_pkts ip_in_octets ip_in_octets ip_in_pkts ip_in_ucast_pkts ip_in_bcast_pkts ip_in_mcast_pkts ip_err_crc ip_err_hdr_cksum ip_err_tcp_data_chksum See Also portErrShow, portShow 159896 IP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 553
. The result of this operation is persistent across reboots and power cycles. To undo a previous port swap, execute portSwap again number of the second port whose area number is to be swapped, relative to its slot for bladed systems. Examples To swap area numbers between a pair of ports: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 554
enabled state of the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not effect previously . Operands none Examples To disable the portswap feature: switch:admin> portswapdisable See Also portSwap, portDisable, portEnable, portShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 555
enabled state of the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not effect previously . Operands none Examples To enable the portswap feature: switch:admin> portswapenable See Also portSwap, portDisable, portEnable, portShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 556
of the portswap feature, as well as port and area information for those ports whose area number id different from the default area number. The default area number of a port is same as its switch port number. The execution of this command is subject to Admin Domain restrictions that may be in place - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 557
following port types are supported: • E_Ports • F_Ports (must support ELS Echo) • L_Ports default, all the user ports in the switch are tested. Refer to itemList help pages for further details. -iteration count Specify the number of times (or number of frames per port) to execute this test. Default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 558
dataTypeShow command to view the types of pattern that are supported with portTest. dataTypeShow displays the pattern name, the pattern number to use with this option, and an example of this pattern. The default pattern type, if no pattern number is specified, is RANDOM (type=11) Specify the size of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 559
operand: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the current slot will be assumed. Refer to pages for further details. Examples To display information from portTest: switch:admin> porttestshow 1 Port 1 : PASS PortType: OTHER PortInternalState: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 560
of the F/FL-ports of a switch. Output shows virtual port number (decimal), physical port number (decimal), online status (and if . When default zoning is enabled with "No Access" mode, "No Effective configuration: (No Access)" is displayed. Notes This command requires a Brocade Advanced Zoning - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 561
done. This is because the lack of power causes the CP boards' processors to cease execution of the firmware. In this situation, all operation of the system terminates immediately: for instance, if two power supplies already have been removed from a Brocade director, and than a third one is removed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 562
off: (7..10) [7] 10 6th slot to be powered off: (7..9) [8] 9 7th slot to be powered off: (7..8) [8] 8 8th slot to be powered off: (7..7) [7] 7 Old POL New POL Power Off Order 10 1 1st 9 2 2nd 8 3 3rd 7 4 4th 4 10 5th 3 9 6th 2 8 7th 1 7 8th Proceed to change the POL - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 563
Operands none Examples To display the slot power off list order: switch:admin> powerofflistshow Slot 10 will be powered off 1st Slot 9 will be powered off 2nd Slot 8 will be powered off 3rd Slot 7 will be powered off 4th Slot 6 will be powered off 5th Slot 5 will be powered off 6th Slot 4 will be - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 564
restrictions that may be in place. Operands none Examples To view the status of the power supplies: switch:admin> psshow Power Supply #1 is OK DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #2 is faulty DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #3 is OK DELTA DPS-1001AB-1E 23000000601 S1 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 565
Reboots the control processor (CP) in a switch or a director. Synopsis reboot -f Description When this command is issued on a switch, if the switch is part of a fabric, all traffic to and from that switch stops. All Fibre Channel ports on that switch including E_Ports become inactive until the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 566
to Admin Domain restrictions that may be in place. Operands none Examples To display a list of routing-related commands: switch:admin> routehelp aptpolicy bcastshow dlsreset dlsset dlsshow fspfshow interfaceshow iodreset iodset iodshow linkcost lsdbshow nbrstateshow nbrstatsclear topologyshow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 567
. For switches running earlier versions of Fabric OS (up to v5.3.0), the maximum is 256 Kb. Notes The effective security DB size is the lowest supported by the CP that runs Fabric OS v6.0.0. The Brocade 200E is unable to handle the maximum DB size supported in v6.0.0 and will issue a compact flash - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 568
the command is completed new data is saved persistently. New data is effective with the next authentication request. The configuration applies to a switch instance only. Operands This command has the following operands: --show Lists the WWNs for which shared secret is configured. --set Sets - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 569
secret: Enter local secret: Re-enter local secret: Enter WWN, Domain, or switch name (Leave blank when done): Are you done? (yes, y, no, n): [ to key store... Done. To delete the entire secret key database: switch:admin> secAuthSecret --remove --all This command deletes database of DH-CHAP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 570
PKI-based certificates in the switch. Synopsis seccertutil Description Use this command to manage third-party certificates in the switch. name. • Enable secure protocols. Operands The following operands are supported: delcsr Delete CSR delete file name Delete certificate export Export CSR - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 571
To generate a CSR: switch:admin> seccertutil gencsr Country Name (2 letter code, eg, US): State or Province Name (full name, eg, California): Enter Password: password Success: imported certificate [certificate file name]. To import a certificate with configure and enable option: switch:admin> - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 572
: password Success: imported certificate [certificate file name]. Certificate file in configuration has been updated. Secure http has been enabled. To display contents of a CSR: switch:admin> seccertutil showcsr To display contents of a certificate: switch:admin> seccertutil show certificate file - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 573
running Fabric OS v6.0.0 and later, the maximum security database size is 1 Mb. For switches running earlier versions of Fabric OS (up to v5.3.0), the maximum is 256 Kb. The effective security DB size is the lowest supported by the fabric. The presence of a Standby CP that runs an earlier version of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 574
. The information displayed may not be supported between releases and is subject to change without notice. Operands Examples none To view the current security state: switch:admin> secglobalshow ----General Security Information---flag 1, saveflag 0 transId 0 Queue Size 0 final Rca 0 reliablemsg - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 575
secGlobalShow 2 primaryDLPhase 0 ----wwnDL State----- pid tid key sec usec --------- LOG CACHE --------14:08:50 813905136 secipadm_ipchange receives notification 14:08:50 850588912 secProcessIPChange starts processing 14:08:50 850588912 secProcessIPChange acks completion [Output truncated] - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 576
of existing policies Moves a member in the FCS policy Removes members from an existing policy Saves defined policy set and sends to all switches Shows members of one or more policies Resets security statistics Displays security statistics See Also none 550 Fabric OS Command Reference 53-1000599 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 577
consistency policy is not set for the particular policy. Notes When FCS Policy is enabled, this command can be issued only from the Primary FCS switch. Only the user who made the changes to the defined database may use this command to abort them. Operands none Examples To abort all changes - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 578
is the same for tolerant and strict fabric-wide consistency. When FCS Policy is enabled, this command can be issued only from the Primary FCS switch. Any modifications to SCC, DCC, and FCC DB are saved and activated. When secPolicyActivate is issued after the secPolicySave command, it might fail - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 579
(the DCC_POLICY is an exception). Notes When FCS Policy is enabled, this command can be issued only from the Primary FCS switch. The secpolicyadd command can be issued on all switches for SCC and DCC policies as long as fabric-wide consistency policy is not set for the particular policy. Do not - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 580
DCC_POLICY does not stop access to the switch. The device is specified with a WWN string. The switch and port combination must be in the following format: switch port switch can be specified using WWN, domain, or switch name. port can be specified by port numbers separated by commas and enclosed in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 581
policies can be created only once, except for the DCC_POLICY_nnn. Each DCC_POLICY_nnn must each have a unique name. This command can be issued on all switches in the current fabric for SCC and DCC policies if they are not intended to be fabric-wide. Adding members while creating a policy is optional - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 582
DCC_POLICY does not stop access to the switch. The device is specified with a WWN string. The switch and port combination must be in the following format: switch port switch can be specified using WWN, domain, or switch name. port can be specified by port numbers separated by commas and enclosed in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 583
secPolicyCreate 2 See Also fddCfg, distribute, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow Fabric OS Command Reference 557 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 584
Notes The FCS_POLICY cannot be deleted through this command. When an FCS policy is enabled, this command can be issued only from the Primary FCS switch. Operands This command has the following operands: "name" Specify the name of a security policy to delete. The policy name must be enclosed in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 585
defined (saved) databases. This command can be issued from all FCS switches in the fabric. Operands This command has the following operands: " 15:5c 1 primaryfcs 2 No 10:00:00:60:69:30:1e:62 4 switch ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10:00:00:60 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 586
Only one FCS can be moved at a time. The first FCS switch in the list that is also present in the fabric is the Primary FCS. FCS Policy must be enabled on the switch to execute this command. If no parameters are specified, the command becomes interactive, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 587
...]" Description Use this command to remove members from an existing security policy. It is not possible to remove all members from the FCS_POLICY; the local switch WWN cannot be deleted from the FCS policy. In the case of SCC policy, if it is empty after removing all members, all access to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 588
2 secPolicyRemove port can be specified by port number separated by commas, and enclosed in either ports 1 through 3 and 5 and all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. Examples To remove a member that has a WWN of 12:24 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 589
memory. Secpolicysave saves the modified SCC, DCC, and FCS policies to the Defined Security Policy Set on the local switch. This command is always a local switch operation. A fabric-wide consistency configuration does not affect the behavior of this command. Operands none Example To save defined - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 590
to display the members of an existing policy in the Active or Defined security policy set. The command can be issued from all FCS switches. This command displays the policy database one page at a time. Use secPolicyDump to display the policy database without page breaks. Operands This command has - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 591
secPolicyShow 2 See Also fddCfg, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave Fabric OS Command Reference 565 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 592
secstatsreset [name][," domain[;domain]" ] Description Use this command to reset one or all security statistics to 0. This command can be issued on any switch to reset the security statistics on the local switch or chassis. If FCS policy is enabled and secStatsReset is issued on the primary FCS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 593
secStatsReset 2 domain(s) Specify a list of domain IDs on which to reset the security statistics. Specify an asterisk (*) to represent all switches in the fabric or specify a list of domains, separated by semicolons and enclosed in quotation marks. This option can only be executed when FCS policy - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 594
security statistics. Synopsis secstatsshow [name[, "domain[;domain]"]] Description Use this command to display one or all security statistics. This command can be issued on any switch to display local security statistics. If FCS policy is enabled and secStatsShow is issued on the primary FCS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 595
are grouped together. Specify a list of domains, for which to display the security statistics. Specify an asterisk (*) in quotation marks to represent all switches in the fabric or specify a list of domains separated by semicolons. This option can only be executed when FCS policy is enabled and the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 596
sensorshow Description Use this command to display the current temperature, fan, and power supply status and readings from sensors located on the switch. The actual location of the sensors varies, depending on the switch type. The execution of this command is subject to Admin Domain restrictions - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 597
display of debug messages to the serial console. By default, no debug messages are displayed. High debug level system response time. The set of supported modules and their current debug levels are of module named NS to value 3: switch:admin> setdbg NS 3 switch:admin> dbgshow NS Module NS, debug - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 598
mode. -show Specify the -show operand to display the current setting. This operand is optional. Examples To enable the media mode: switch:admin> setgbicmode 1 GBIC mode is now 1 (Enabled). See Also itemList, miniCycle, setMediaMode, setSfpMode 572 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 599
media mode. -show Specify the -show operand to display the current setting. This operand is optional. Examples To display the media mode: switch:admin> setmediamode -show Media mode is now 0 (disabled). See Also itemList, miniCycle, setGbicMode, setSfpMode Fabric OS Command Reference 573 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 600
dial-in to a CP on those systems that support modem dial-in. When modem dial-in is enabled a 11 d 10 c 9 b 8 a 7 d 6 c 5 b 4 a 3 d 2 c 1 b 0 a ! ! POWER SUPPLY 3 ! ! POWER SUPPLY 2 ! ! scale: 1/8" = 1" POWER SUPPLY 1 & 3 POWER SUPPLY 2 & 4 200-240 VAC 12A 50-60 Hz 200-240 VAC 12A 50-60 Hz - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 601
: -e Specifies that modem dial-in be enabled. -d Specifies that modem dial-in be disabled. Examples To disable modem dial-in to a CP: switch:admin> setmodem -d disabling modem, please wait, this can take a couple of minutes... modem disabled See Also none Fabric OS Command Reference 575 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 602
-show operand to display the current setting. This operand is optional. Examples To enable, disable, and then display the media mode: switch:admin> setsfpmode 0 SFP mode is now 0 (disabled). See Also itemList, miniCycle, setGbicMode, setMediaMode 576 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 603
filter the display of the debug message to the serial console. By default, no debug messages are displayed. The execution of this command is subject To set the verbose level of module named NS to value 3: switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, verbose - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 604
module temperature, voltage, received optical power, transmitted optical power (longwave only), and laser number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, this command displays a summary of all SFPs in the switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 605
3164.8 mVolts RX Power: 199.6 uWatts TX Power: 235.2 uWatts To display detailed information for GbE port 0 on a Brocade 7500: switch:admin> sfpshow ge0 information for GbE port 0 on an FR4-18i router blade: CS48000:admin> sfpshow 10/ge0 Fabric OS Command Reference 579 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 606
: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 0 BR Min: 0 Serial No: A00143427 Date Code: 020511 To display all SFP information: switch:user> sfpshow -all Port 0: Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 607
See Also Length 50u: 30 (units 10 meters) Length 62.5u:15 (units 10 meters) Length Cu: 0 (units 1 meter) Vendor Name: IBM Vendor OUI: 08:00:5a Vendor PN: IBM42P21SNY Vendor Rev: AA10 Wavelength: 0 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 5 BR Min: 5 Serial No: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 608
serial ports. Flow control is disabled by default. Because this command changes the flow the configuration database; therefore, persistent across reboots and power cycles. Notes On dual control processor (CP) To disable flow control: switch:admin> shellflowcontroldisable Disabling flowcontrol - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 609
shell task. Flow control is disabled by default. Because this command changes the flow control configuration database; therefore, persistent across reboots and power cycles. Notes On dual control processor (CP) for an extended period of time, the switch might reboot. It is recommended to disable - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 610
command has the following operand: slotnumber Specify the slot number of the blade to be powered down. This operand is required. Examples To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow 584 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 611
. Operands This command has the following operand: slotnumber Specify the slot number of the blade to be powered on. This operand is required. Examples To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. See Also slotPowerOff, slotShow Fabric OS Command Reference 585 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 612
FC4-48 port blade 39 FC10-6 port blade 50 CP8 control processor blade 52 Core8 switch blade 37 FC8-16 port blade 55 FC8-32 port blade 51 FC8-48 port blade Status Displays the status of the blade as one of the following: VACANT The slot is empty. INSERTED, NOT POWERED ON The blade is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 613
the SAS Virtualizaion services are disabled. Only applies to the FA4-18 blade. DISABLED The blade is powered on but disabled. FAULTY The blade is faulty because an error was detected. UNKNOWN The blade is inserted but its state cannot be determined. Operands The SlotShow command supports the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 614
BTU) Power Efficiency: 9.91 watts per port, 2.48 watts per Gb To display Brocade model names for each blade in the chassis: switch:user> slotshow -m Slot Blade Type ID Model Name Status 1 AP BLADE 33 FA4-18 ENABLED 2 SW BLADE 55 FC8-32 ENABLED 3 SW BLADE 37 FC8-16 ENABLED - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 615
this command to verify the intended functional operation of the switch by sending SERDES BIST patterns from port N's transmitter, sec (default) -ports itemlist Specifies a list of blade ports to test. Specify the slot number followed by a slash (\) on bladed systems. By default, all the blade ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 616
2 slTest -passcnt count Specifies the number of test repetitions. By default, the test runs once. Refer to itemList for further details. Examples To test the serial link of the following port path: switch:admin> sltest -ports 0/5-0/31 -speed 4 -lb_mode 1 passcnt 1 Running Port sltest .... - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 617
switch. The configuration includes SNMPv1 and SNMPv3 configuration, access control list (ACL), MIB capability, system group, and security level settings. The command supports set, reset to default include user name, authentication protocol and password, SNMPv3 trap recipients IP address, associated - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 618
of 2 to 16 characters. The default values for the primary FCS switch only, and only the primary FCS switch propagates changes across supported. Separate default passwords are provided for creation of authKey and privKey for each entry. The default set of passwords are published and the default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 619
password to default. If FCS policy is enabled, the above configuration has to be updated on both primary and nonprimary switches, and unlike community strings, user name and passwords is not distributed for other switches in the fabric. When new passwords an ACL of 192.168.64.0 enables access by any - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 620
set as End User Premise. sysContact The contact information for this system (switch). The default value is set as Field Support. Refer to the definition of sysDescr, sysLocation and sysContact in system group of MIB-II. authTraps When enabled, the authentication trap (authenticationFailure) is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 621
switch:admin> snmpConfig --show snmpv1 SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) Trap recipient: 10.32. must be between 2 and 16 - please re-enter Community (rw): [OrigEquipMfr] Trap Recipient's IP address: [1080::8:800:200C:1230] 10.32.147.113 Community (rw): - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 622
systemGroup configuration to default values: switch:admin> snmpconfig --default systemGroup ***** This command will reset the agent's system group configuration back to factory default ***** sysDescr = Fibre Channel Switch sysLocation = End User Premise sysContact = Field Support authTraps = 0 (OFF - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 623
[1] See Also None SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap" RFC1157, "A Simple Network Management Protocol (SNMPv1)" RFC1213, "Management information Base for Network Management of TCP/IP-based internets: MIB-II" RFC2574, "User-based Security Model (USM) for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 624
only approximately counts the frames and the actual number of frames sent will be slightly larger, particularly at 2 Gbit/sec link speeds. -ports itemlist Specify a list of user ports to test. By default, all of the ISL ports in the current switch will be tested. Refer to itemList help pages - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 625
spinFab 2 -setfail mode Instruct spinFab how to mark failed ports. If set to 1, it might be useful with large values of -nmegs count. This mode is disabled by default. Examples To test cascading ISL links: switch:admin> spinfab -ports 1/0 - 1/2 spinfab running... spinfab: Completed 11 megs, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 626
2 spinFab See Also itemList, portLoopbackTest 600 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 627
to clear the port and diagnostics statistics for the specified list of blade or user ports. You can issue this command on the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This availability is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 628
Domain restrictions that may be in place. Operands This command has the following operand: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help pages for further details. Examples To stop the portTest command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 629
when a message with FFDC attributes is logged. FFDC is enabled by default. The execution of this command is subject to Admin Domain restrictions that FFDC configuration: switch:admin> supportffdc --show First Failure Data Capture (FFDC) is disabled. To enable the FFDC events: switch:admin> - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 630
48 characters. -p password Specifies FTP user password. If the user name is anonymous, the password is not needed. password should be less than 48 is not specified, the supportFtp command defaults to supportFtp -S. Examples To set the FTP parameters: switch:admin> supportftp -s -h 192.168. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 631
:admin> supportftp -s Host IP Addr[1080::8:800:200C:417A]: User Name[njoe]: Password[********]: Remote Dir[support]: Auto file transfer parameters changed To display a time interval to check the FTP server: switch:admin> supportftp -t 24 supportftp: ftp check period changed. To enable auto file - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 632
the switch after the command.The FFDC data will be removed after the command. If there are BP blades installed in the switch, it will also retrieve support file is optional; if omitted, anonymous FTP is used. -p password Specifies the password for the FTP server. This operand is optional; if - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 633
-Zone_Log.ss: 27.71 kB kB/s 9.23 Saving support information for switch:swd76, module:Zone_Log... /tmp/supportSave_files/swd76-S6-200508280207-Zone_Log.ss: 48.16 kB kB/s 16.02 Saving support information for switch:routing1, module:RCS_Log... ...portSave_files/routing1-S6-200508280207-RCS_Log - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 634
-S6-200508280208-CHKCONFIG.ss: 1.04 kB 694.31 B/s Saving support information for switch:routing1, module:CONSOLE... ...e_files/routing1-S6-200508280208-CONSOLE: 64 kB 694.31 B/s Saving support information for switch:routing1, module:CHKRPM... ...e_files/routing1-S6-200508280208-CHKRPM.ss: 10 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 635
-Zone_Log.ss: 27.71 kB kB/s 9.23 Saving support information for switch:swd76, module:Zone_Log... /tmp/supportSave_files/swd76-S6-200508280207-Zone_Log.ss: 48.16 kB kB/s 16.02 Saving support information for switch:routing1, module:RCS_Log... ...portSave_files/routing1-S6-200508280207-RCS_Log - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 636
switch information for debugging purposes. Synopsis supportshow [[slotnumber/]portnumber1-portnumber2] [lines] Description Use this command to display support be run for diagnostic support. The commands have been arranged in groups identified as follows: OS (ENABLED by default) top mii-tool du - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 637
fabSwitchShow fabPortShow fspfShow nbrStateShow fcpLogShow zone stateshow portZoneShow cfgShow cfgSize rcssmshow rcsInfoShow rcsregistryshow zone mergeshow zone stateshow services (ENABLED by default) fdmiCacheShow fdmiShow nsShow nsAllShow nscamShow nscamShow -t ns portshow security (ENABLED by - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 638
2 supportShow sin df ifconfig route hostname portlog (ENABLED by default) portLogDump system (ENABLED by default) myId version firmwareShow upTime switchStatusShow switchShow haDump (includes haShow and ipAddrShow) tempShow sensorShow psShow licenseShow portFlagsShow portCfgShow portErrShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 639
rlir ficonShow rnid ficonShow switchrnid ficucmd dump -A FC-FC Routing (DISABLED by default) fcrProxyDevShow fcrProxyConfig fcrXlateConfig fcrPhyDevShow fcrRouteShow fcrFabricShow fcrResourceShow FCIP (DISABLED by default) portShow fciptunnel ge$k all portShow fciptunnel $1/ge$k all The execution of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 640
. If the slotnumber/portnumber parameter is omitted, all ports in the switch display in the per-port outputs. The slotnumber must be provided when specifying a range of ports on multi-bladed products. lines Specifies the number of lines of portLogDump output to display. If this parameter used - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 641
group commands fabric Disables the fabric group commands services Disables the service group commands security Disables the security group commands the OS group of commands under the supportShow command: switch:admin> supportshowcfgdisable os Config update Succeeded See Also supportShow, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 642
port group commands fabric Enables the fabric group commands services Enables the service group commands security Enables the security group commands enable a group of commands under the supportShow command: switch:admin> supportshowcfgenable os Config update Succeeded See Also supportShow, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 643
Examples To display which groups of commands are enabled in thesupportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 644
switch beaconing mode. When beaconing mode is turned on, the port LEDs flash amber, left to right and right to left, from port 0 to the highest port number only the beaconing pattern is shown. However, if diagnostic frame-based tests (such as portLoopbackTest) are executed, two patterns are - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 645
. Synopsis switchcfgpersistentdisable Description Use this command to persistently disable the switch. All Fibre Channel ports are taken offline. If the switch was part of a fabric, the remaining switches reconfigure. The switch remains disabled even after a reboot. The disable process can be - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 646
switchcfgpersistentenable Description Use this command to persistently enable the switch. All Fibre Channel ports which did not fail power-on self-test (POST) are enabled, and can come online if connected to a device, or remain offline if disconnected. The switch might need to be enabled if it was - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 647
Use this command to configure the speed of all the ports on a switch to a particular level. The configuration is saved in flash memory and persists across switch reboots or power cycles. If any port on the switch is not capable of the specified speed setting, an error message displays for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 648
. Synopsis switchcfgtrunk mode Description Use this command to enable or disable trunking on all the ports of a switch. This command requires the Brocade ISL Trunking license. You can disable or enable trunking using the portCfgTrunkPort or switchCfgTrunk commands. When the command is executed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 649
switch. All Fibre Channel ports are taken offline; if the switch was part of a fabric, the remaining switches reconfigure. The switch require the switch to be disabled send an error if invoked while the switch is enabled. The switch does not need to be disabled before rebooting or powering off. As - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 650
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable a switch: switch:admin> switchenable See Also switchCfgPersistentDisable, switchCfgPersistentEnable, switchDisable, switchShow 624 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 651
is subject to Admin Domain restrictions that may be in place. Operands This command has the following operand: name Specify a new name for the switch. name can include up to 15 characters, must begin with a letter, can consist of letters, digits, hyphens, and underscore characters, and no spaces - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 652
. This command is not supported on single-domain systems. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To reboot an operational switch: switch:admin> switchreboot Stopping all switch daemons...Done. Powering off slot 1...Done - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 653
Part of the 24-bit port ID, which consists of domain, area number, and optional AL_PA. Area column is only displayed for non-slot based platforms port number relative to the switch. Index column is only displayed for slot based platforms. Slot Slot number; 1-4 and 7-10. Port Port number; 0- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 654
marked faulty. Port failed diagnostics. Locking to the reference signal. Running diagnostics. Connection not established (for virtual ports only). Port is up and running. Protocol support by GbE port. Ports support ISCSI. 628 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 655
level number. See portCfgLongDistance for the level description. In an AD context, if one of the L-ports or NPIV ports is a part of Brocade 48000 and a Brocade 24000. If the ISL is between a Brocade 48000 and a Brocade 4100 or 200E, the disabled E_Port displays as No_Sync. On a Brocade 7600 switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 656
Causes the switchShow command to display the number of ports on the iSCSI sessions associated with GE ports in a switch. Examples To display the port count: switch:admin> switchshow -portcount ports= 64 To display GE ports with iSCSI sessions: switch:admin> switchshow -iscsi Ports of Slot 1 ge0 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 657
15 035f00 id N2 Online 10:00:00:00:00:02:00:00 208 8 16 03d000 -- -- Offline [output truncated] 216 8 24 03d800 -- -- Online 10:00 To display a switch in Access Gateway mode: switch:admin> switchName: switchType: switchState: switchMode: switchWwn: switchBeacon: switchshow switch 34.0 Online - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 658
Status Contributor DOWN Default MARGINAL Default PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 Any single contributor can force the overall status of the switch to MARGINAL or DOWN - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 659
the policy parameter is NOT applicable to the switch. ** Simply hit the Return key. The minimum number of Bad PowerSupplies contributing to DOWN status: to MARGINAL status: (0..2) [1] Down Blade contributing to DOWN status: (0..8) [0] Down Blade contributing to MARGINAL status: (0..8) [1] - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 660
, Values, and Status Contributor DOWN Default MARGINAL Default PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 The policy parameters determine the number of failed or non-operational - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 661
MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow switchStatusPolicyShow 2 Fabric OS Command Reference 635 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 662
with a Fabric Watch license are able to view the list of unhealthy ports. This command displays the overall switch status, and the status of the following contributors: • Power supplies • Temperatures • Fans • WWN servers (dual CP systems only) • Standby CP (dual CP systems only with HA enabled - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 663
that is configured with an IPv4 address: switch:user> switchstatusshow Switch Health Report Switch Name: switch IP address: 10.32.89.26 SwitchState: MARGINAL Duration: 80:12 Report time: 09/11/2006 05:39:28 PM Power supplies monitor Temperatures monitor Fans monitor Flash monitor Marginal - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 664
has been operating. Synopsis switchuptime Description Use this command to display the current time and the amount of time that the switch has been operational. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To view the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 665
the violation type as DCC. Notes This command can be executed on both active and standby CP. This command does not support HA. Examples To display DCC violations on a switch: switch:admin> switchviolation --dump -dcc Device WWN Port 22:00:00:04:cf:75:59:87 10 See Also None Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 666
forwarding messages to the servers added through the command syslogdIpAdd. The default facility is LOG_LOCAL7. The execution of this command is subject to is displayed. Examples To set the syslog facility to LOG_LOCAL1: switch:admin> syslogdfacility -l 1 Syslog facility changed to LOG_LOCAL1 See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 667
users, depending on the system configuration. When one or more IP addresses are configured, the switch forwards all error log entries to the syslogd on the specified server(s). Up to six servers are supported. The syslogdipadd command accepts IPv4 and IPv6 addresses. The execution of this command is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 668
is required. Examples To remove the address 1080::8:800:200C:417A from the list of machines to which system messages are sent: switch:admin> syslogdipremove 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpShow 642 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 669
subject to Admin Domain restrictions that may be in place. Operands none Examples To display all syslog daemon IP addresses: switch:admin> syslogdipshow syslog.IP.address.1 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpRemove Fabric OS Command Reference 643 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 670
system. For Brocade directors, when sysShutDown is called in the active control processor (CP), the command shuts down the active CP, standby CP, and any AP blades. After doing this, you need to manually power off the system. If you want to reboot the system, manually turn the power switch on. This - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 671
: device is busy The system is halted flushing ide devices: hda Power down. ppc440gx System Halted For the FR4-18i AP blade, to perform a system shutdown from the standby CP: switch:admin> sysshutdown Shut down the whole system is not support from the standby CP For shut down the whole system please - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 672
These diagSetCycle parameters are copied to all switches in the system and override the supported, this parameter is optional, but -unit is required for single FRU testing. -unit id Use to focus testing on a single FRU in the system. The id for a FRU type of BLADE correlates to the slot number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 673
in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 - thermal : 10 SYSTEMVERIFICATION - label : BURNIN 2 - min_lb_mode - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 674
For each sensor, this command displays the slot number (if applicable), the sensor state, and the temperature. The temperature readings are given in both Centigrade and Fahrenheit. Notes Refer to the hardware reference manual for your switch to determine the normal temperature range. The execution - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 675
in place. Operands This command has the following operand: timeval Specify the number of minutes for the telnet timeout value. Valid values are 1 to timeout value. Examples To set the idle timeout to 10 minutes: switch:admin> timeout 10 IDLE Timeout Changed to 10 minutes The modified IDLE - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 676
part of the fabric, and to each of those domains, all possible paths from the local switch. For each path cost, the associated output port on the local switch, the path cost, the number of hops from the local switch to the destination switch is adjusted to the nearest power of 2 value, while a bandwidth - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 677
the fabric; Local Domain ID: 1 Local Translate Domain 4 owned by port: 5 Local Translate Domain 8 owned by port: 4 Domain: 6 Metric: 500 Name: switch Path Count: 4 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 1 60 None 2.000 Gbps 0 % D Hops: Out Port: In Ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 678
dump, or to display the dump status on the switch. If there is no parameter specified, this command defaults to traceDump -S. The default remote file name format is chassisname-S#-YYYYMMDDHHMMSS.dmp, in which # is the slot number (0 on nonbladed systems) and YYYYMMDDHHMMSS (year-month-day-hour - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 679
is subject to Admin Domain restrictions that may be in place. Examples To display information on the track-changes commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays status of track changes See Also trackChangesSet - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 680
output from the track-changes feature is dumped to the error log for the switch. Use errDump or errShow to view the error log. The execution of this to enable the track-changes feature or 0 to disable the feature. The default (if no operand is specified) is to disable the track-changes feature. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 681
output from the track-changes feature is dumped to the error log for the switch. Use the errDump command or errShow command to view the error log. The Examples To display the status of the track-changes feature: switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 682
of port 2. Use the switchShow command to view the area numbers for a port. This operand is required. Examples To debug a trunk connection: switch:admin> trunkdebug 43 44 Switch does not support trunking switch:admin> trunkdebug 62 63 port 62 and 63 are trunked together See Also portCfgTrunkPort - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 683
following fields display: Trunking Group Number Displays each trunking group on a switch. All the ports that are part of this trunking group are 16 deskew 15 deskew 17 deskew 16 MASTER 3:24 -> 14 10:00:00:60:69:51:42:dd deskew 15 MASTER To display trunking information for a switch that is part - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 684
-> 23 10:00:00:05:1e:37:12:13 64-> 16 10:00:00:05:1e:37:12:13 65-> 19 10:00:00:05:1e:37:12:13 4 deskew 17 MASTER 4 deskew 16 4 deskew 16 4 deskew 16 4 deskew 17 4 deskew 17 4 deskew 15 4 deskew 16 switch:admin> switchshow 48 4 0 013000 id N4 Online EX-Port (Trunk port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 685
switches in the fabric, but only the principal switch (when FCS policy is not enabled) or the primary FCS switch (when FCS policy is enabled) connect to the NTP server and broadcast time service updates. All switches server back to default. The NTP server used must support a full NTP client. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 686
2 tsClockServer See Also date 660 Fabric OS Command Reference 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 687
default. Time zone is used only in computing local time, which is used for error reporting and logging. An incorrect time zone setup does not affect the switch operation in any way. System services started during the switch is optional. minuteOffset Specify the number of minutes relative to hour - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 688
which will then default to zero. west coast of America, using interactive mode: switch:admin> tsTimeZone --interactive Please identify a 48) Virgin Islands (UK) 15) Cuba 32) Netherlands Antilles 49) Virgin Islands (US) 16) Dominica 33) Nicaragua 17) Dominican Republic 34) Panama Enter number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 689
- south Idaho & east Oregon 16) Mountain Time - Navajo 17) Mountain 32:45 UTC 2006. Is the above information OK? 1) Yes 2) No Enter number or control-D to quit ?1 System Time Zone change will take effect at next reboot To revert back to the old format: switch admin> tstimezone --old 2 switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 690
designated to operate on fixed-port-count products. -passcnt count Specifies the number of times to perform this test. The default value is 1. -ports itemlist Specifies a list of blade ports to test. By default, all the blade ports in the specified slot are tested. Refer to the itemList command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 691
system load averages for the past 1, 5, and 15 minutes. For up and powered-on times less than 60 seconds, the time is displayed in seconds. For Operands none Examples To display the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 692
are forwarded through out_area port. If port number out_area port is not associated with such a using static routes, load sharing might be affected. The switch attempts to achieve optimum load sharing, but if too route configuration is not supported on Brocade directors set to chassis configuration - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 693
the destination domain of the static route to remove. Examples To remove a static route for all traffic coming in from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See Also configShow, dlsShow, uRouteConfig, uRouteShow Fabric OS Command Reference 667 53-1000599-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 694
(Dom, Port) Domain and port number of the next hop. These are the domain number and the port number of the switch to which Out Port is connected. For bladed systems only, specify the slot number of the input port whose routes are displayed, followed by a slash (/). portnumber Specify the number of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 695
Flags Next (Dom, Port) 0 1 11 1000 1 D 1,0 11 2 0 1500 2 D 4,0 4 0 500 1 D 4,0 16 1 27 1000 1 D 1,1 27 2 16 1500 2 D 4,16 To display the routing information of port 11 to domain 4 only: switch:admin> urouteshow 1/11, 4 Local Domain ID: 3 In Port Domain Out - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 696
. Refer to the Fabric OS Administrator's Guide for details. Operands All operands are exclusive space. Valid applications are: firmware, support, config, firmwarekey. A of the attached USB device: switch:admin> usbstorage -l firmwarekey\ 0B support\ 106MB support1034\ 105MB config\ - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 697
15 15:13 Available space on usbstorage 74% To remove an application area: switch:admin> usbstorage -r firmware FW_v6.0.0 To disable an attached USB device: switch:admin> usbstorage -d USB storage disabled supportSave, firmwareDownload, configUpload, configDownload, firmwareKeyupdate Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 698
, account information is saved persistently. On platforms supporting multiple switch domains, account information is saved only to the switch domain, on which the command was executed. The account database can be distributed manually to other switches in the fabric by using the distribute command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 699
supported on switches running Fabric OS v6.0 or later. As a consequence, account recovery from backup as well as backup display option (former --show -b option) are no longer working on a v6.0 switch permissions or home AD of any default account. • You cannot change the numbered Administrative Domain the user - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 700
add option, AD0 is assigned by default. Use comma-separated lists, ranges, Optionally specifies an expired password that must be changed the switch. This . The following operands are supported: username Specifies the account home AD is set to the lowest numbered AD in the user's AD permissions. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 701
Date: Not Applicable Locked: No AD membership: 0 Home AD: 0 To change account attributes: switch:admin> userconfig --change joe -e no Broadcast message from root Sat Apr 2 03:03:32 2005... Security Policy, Password or Account Attribute Change: joe will be logged out Attribute for account joe has - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 702
default login name, new_username cannot be another default login name. • If new_username is a default login name, it must indicate the same role as old_username. This command is not supported from "USERID" to "admin": switch:admin> userrename USERID admin See Also None 676 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 703
in the boot PROM Usually the Made on and Flash dates are the same, because the switch starts running flash firmware at power-on. However, in the time period between firmwareDownload and the next reboot, the dates can differ. The execution of this command is subject to Admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 704
use switchReboot or reboot to propagate the change to all switch components. However, the restart of the switch must happen before any firmwareDownload or (for bladed systems) CP failover occurs; otherwise, the behavior of the switch could be unexpected. Operands none Examples To display the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 705
. The provision (a.k.a TI Zone) is part of the defined zone configuration and will not appear in the effective zone configuration. A Maximum of 255 TI Zones can be created in one fabric. Notes TI zones are not supported in fabrics involving switches running firmware versions preceding Fabric OS v6 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 706
enclosed in quotation marks. --validate Lists all zone members that are not part of the current zone enforcement table. If a zone member is specified using zone alias or a zone. mode Specifies the zone database location. Supported mode flag values are: 0 Uses the zone database from the current - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 707
the zone is created, by default, with failover enabled and the zone will be activated. This operand is supported only with the --create and TI Zone comes ONLINE again, the route will be setup again and the switch will generate another SCN/RSCN. f Enables failover mode. In failover mode, when - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 708
but is not Admin Domain-aware. • The device is online but it is not part of the current Admin Domain. To copy cur_cfg1 zone configuration from the root zone database (AD0) to the current Admin Domain: switch:admin> zone --copy AD0.cur_cfg1 To copy backup_zn zone from the root zone database (AD0 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 709
-f You are about to prune the zone configurations, based on zone --validate output. Do you want to prune the zone configurations (yes, y, no, n): [no] y 2. Traffic Isolation Zone Commands: To create a Traffic Isolation Zone with failover enabled (default). switch:admin>zone --create -t ti red_zone - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 710
: red_zone: List of port: 9,2; 9,3; 8,3; 8,5; Failover: Disabled Status: Deactivated To display the status of "blue_zone" in the defined configuration: switch:admin>zone --show blue_zone Zone Name: blue_zone: List of port: 1,2; 1,3; 3,3; 4,5 Failover: Enabled Status: Activated See Also ad, zoneHelp - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 711
a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands one or more of the following: A switch domain and port area number pair; for example, "2, 20". View the area numbers for ports using the switchShow command. • - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 712
Spaces are ignored. Zone names are limited to 64 characters. The zone member list must have of the following: • A switch domain and port area number pair. View the area numbers for ports using the switchShow the switch controls data transfer to a port. Notes This command requires a Brocade Advanced - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 713
cannot be used for any other zone object. Zone names are limited to 64 characters. "member" List of members to be included in zone, in quotation or more of the following: A switch domain and port area number pair: for example, "2, 20". View the area numbers for ports using the switchShow command. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 714
zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operand: "zonename" Name of the zone - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 715
none Examples To display zone command help information: switch:admin> zonehelp aliadd alicreate alidelete aliremove alishow cfgactvshow transaction Print zone configurations in transaction buffer Activates or deactivates a default zone configuration. Add a member to a fabric assist zone Create - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 716
name must begin with a letter that can be followed by any number of letters, numbers, and underscores. Names are case sensitive; for example, "Cfg_1" requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 717
zone configuration must be enabled using the cfgEnable command. Notes This command requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operand: "objectName" The name of the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 718
name must begin with a letter that can be followed by any number of letters, numbers, and underscores. Names are case sensitive; for example, "Cfg_1" requires a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 719
a Brocade Advanced Zoning license. When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands one or more of the following: A switch domain and port area number pair: for example, enter "2,20" to view the area numbers for ports using the switchShow command. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 720
), or specify 1 to display the contents of the nonvolatile memory. The default value is 0. This operand is optional. Examples To display all zones beginning with the letters "A" through "C": switch:admin> zoneshow "[A-C]*" zone: Blue_zone 1,1; array1; 1,2; array2 See Also zoneAdd, zoneCreate - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 721
used to be part of the now obsolete secure FOS are fully integrated into the base FOS. This switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can be run on all FCS switches. Must be run from the primary FCS switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 722
Description Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can be run on all switches. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. msTdDisable "ALL" must be run from the primary - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 723
when logged in to the standby CP on a Brocade 48000 or DCX Data Center Backbone director. The full set of commands for your user role are available to the active CP. Commands Supported on the Standby CP The following commands are supported when logged into the standby CP. TABLE 22 Commands - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 724
Saves support information for RASLOG, TRACE, and supportShow. switchName Displays this switch's name . switchViolation Display policy violations recorded in RAS log tsClockServer Displays time zone. upTime Displays how long switch has been up. version Displays firmware - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 725
based systems, check that the command is available on the Control Processor (CP). 2. Role Based The following RBAC permissions are supported: • O = observe refer to the Fabric OS Administrator's Guide. Admin Domain Types are one to execute only if the local switch is part of the current AD. • Allowed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 726
Domain availability of all Fabric OS commands. TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin aaaConfig ad ag agShow aliAdd aliCreate aliDelete aliRemove aliShow aptPolicy auditCfg authUtil bannerSet bannerShow bcastInfoShow bcastShow bladeBeacon - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 727
OM OM OM OM OM O O O O O O O O O OM OM OM OM OM OM OM OM O OM OM Basic Switch Admin O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O Security Admin Domain Admin O Allowed O Allowed O Allowed O Allowed O Allowed O Allowed O Allowed O Allowed O Allowed O Allowed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 728
RBAC Permissions and AD Types TABLE 1 RBAC Availability and Admin Domain Type Command Name User Admin Operator Switch Admin diagSetBurnin diagSetCycle diagShow diagSkipTest diagStatus diagStopBurnin distribute dlsReset dlsSet dlsShow dnsConfig enclosureShow errClear errDelimiterSet O OM OM - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 729
OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM Basic Switch Admin O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O N O O O Security Admin Domain Admin O Allowed O Allowed O Allowed O Allowed O Allowed N SwitchMember OM Allowed N SwitchMember N Disallowed N Allowed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 730
OM OM OM OM OM O OM OM OM OM OM OM OM OM OM OM OM Basic Switch Admin O O O O N O O O O O O O O N O O O O O O O O O O O O O O O OM O O O Security Admin Domain Admin N SwitchMember N SwitchMember OM Allowed N SwitchMember OM AD0Disallowed O SwitchMember O SwitchMember O SwitchMember - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 731
OM OM OM OM OM OM OM OM OM OM OM O OM OM OM OM OM OM OM OM O OM Basic Switch Admin O O O O O OM O O O O OM O O O O O O O O O O O O O O O O O O O OM O O O Security Admin Domain Admin O SwitchMember O SwitchMember O Allowed O SwitchMember O SwitchMember OM Allowed N Allowed N Allowed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 732
OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM N OM N Basic Switch Admin OM O O O OM OM O O O O O O O O O O O O O O O OM O O O O O O O O N OM N Security Admin Domain Admin N SwitchMember O SwitchMember O Allowed N SwitchMember OM Allowed OM Allowed O Allowed N Allowed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 733
OM OM OM OM OM OM OM O OM OM OM OM OM OM O O O OM OM OM OM OM OM OM OM OM Basic Switch Admin O O O O O O O O O O O O O O O O O O O O O O O O O O OM O OM OM OM OM OM OM OM Security Admin Domain Admin N PortMember N SwitchMember N SwitchMember N SwitchMember N SwitchMember N SwitchMember - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 734
and Admin Domain Type Command Name User Admin Operator Switch Admin portCfgGport O portCfgISLMode O portCfgLongDistance O portCfgLport O OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM Basic Switch Admin OM OM OM OM OM OM OM OM OM OM OM OM OM O OM OM OM OM O O O - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 735
OM OM OM OM OM OM OM OM OM O OM N O OM OM OM OM OM OM OM OM OM OM Basic Switch Admin O O N OM O O OM O O O OM OM OM OM O O OM O O O O O O N O O O OM O O O O O O O Security Admin Domain Admin OM SwitchMember N SwitchMember N PortMember N PortMember N Allowed N PortMember N PortMember - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 736
OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM Basic Switch Admin O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O OM OM O Security Admin Domain Admin OM AD0Disallowed OM AD0Disallowed OM Allowed/ AD0Disallowed OM AD0Disallowed OM AD0Disallowed N Allowed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 737
OM OM OM OM OM OM OM N OM OM OM OM OM OM OM O OM OM OM N Basic Switch Admin O O O O O O O O O O O O O O O O OM O O N O O OM OM O O O O O O O N Security Admin Domain Admin O SwitchMember OM Allowed/ SwitchMember O SwitchMember O Allowed/Disallowed N SwitchMember N Allowed N Allowed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 738
OM OM O OM OM OM OM OM Fabric Admin N OM N OM OM OM OM OM OM O OM OM OM OM OM Basic Switch Admin N OM N O O O O O O O O O O O O Security Admin Domain Admin OM SwitchMember OM Allowed OM SwitchMember O Allowed OM Allowed/ SwitchMember O Allowed O Allowed O Allowed O Allowed OM - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 739
522 Bloom-based platform, 333, 386, 450, 497, 627 Brocade 200E switch, 405, 589, 629 Brocade 24000 director, 69, 629 Brocade 3250 switch, 447 Brocade 3850 switch, 447 Brocade 3900 switch, 447 Brocade 4100 switch, 144, 145, 405, 589, 629 Brocade 48000 director, 405, 589, 629 Brocade 4900 switch, 144 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 740
supported on the standby CP, 697 Condor-based platform, 333, 386, 450, 497, 627 configDefault, 74 configure, 87 Control Processor, 699 and RBAC, 699 CSR certificates, 545 deleting certificates, 545 D default load sharing DMA test, 170 domain name service, 120 dual CP system active CP and supportFTP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 741
, 254 and haFailover, 257 and haSyncStop, 261 FA-MIB, 593 fastwrite, 503 FA-TRAP, 594 faZoneCreate zoning, 151 FC Router, 170, 172, 173, 179, 180, 181, 183, 185, 186, 187, 188, 191, 192, 325, 553, 627 FC2-16 port blade, 447 FC4-16 port blade, 586 FC4-32 port blade, 586 FCAP, 38, 40 FCIP, 156, 158 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 742
309, 354, 358, 361 ISL Inter-Switch Link, 399 ISL Trunking, 463, , 68 Advanced Zoning, 30, 31, 32, 33, 52, 53, 54, 55 logical SAN, 325 login, 323 long distance settings, , 87, 88 memory usage, 330 MIB, 68, 69, 74, 91, password and login, 323 and SNMPv3, 593 and supportFTP, 604 and supportSave, 606 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 743
106, 107, 108, 111, 147, 587, 620, 624 disabling, 100 power-on self-test, see POST primary FCS, 30, 31, 32, 33, 34, 53, 54, 55, 56, 57, 58, 60, 61 secPolicyActivate, 552 secPolicyAdd, 553 secPolicyFCSMove, 560 secStatShow, 568 secure mode, 30, 31, 32, 33, 34, 94, 411, 508, 551, 552, 558, 559, 560, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 744
, 76, 124, 127, 173, 308, 553, 554, 556, 561, 625 switch speed, 621 switchBeacon, 618 switchShow, 629 SW-TRAP, 594 syslog, 123, 640, 641, 643 sysShutdown active CP, 644 system services, 91, 661 system time zone, 661 systemGroupConfiguration parameters, 594 systemVerification, 646 T tape pipelining - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 745
zoneShow, 694 zoning Advanced Zoning commands, xxiv and aliCreate, 31 and cfgSize, 65 and configDefault, 74 and configDownload, 76 and lsanZoneShow, 325 cfgSave, 61 clearing zoning configurations, 54 creating, 55 disabling, 57 display in fabStatShow, 141 displayed in fcPing, 161 enabling zone - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 746
720 Fabric OS Command Reference 53-1000599-01
53-1000599-01
19 Oct 2007
Fabric OS
Command Reference Manual
Supporting Fabric OS v6.0.0