HP StorageWorks 4/8 Brocade Error Message Reference Guide v6.0.0 (53-1000600-0
HP StorageWorks 4/8 - SAN Switch Manual
View all HP StorageWorks 4/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/8 manual content summary:
- HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 1
53-1000600-01 19 October 2007 Fabric OS Message Reference Supporting Fabric OS v6.0.0 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 2
license agreements. To find-out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd. Export of technical data contained in this - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 3
History The following table lists all versions of the Brocade Fabric OS Message Reference. Document Title Publication Number -0000515-08 Update software and hardware support March 2004 Fabric OS System Error Message 53-0000515-09 Updated for v4.4.0, Reference Manual First RASLog release August - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 4
-1000046-02 Minor updates to a few messages. Reference Manual June 2006 Fabric OS Message Reference 53-1000242-01 - -Deleted USWD chapter. -Updated Introductory chapters. -Update throughout: rebranding, supported hardware, CLI changes. 15 June 2007 Fabric OS Message Reference 53-1000600- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 5
Is Organized xlvii Supported Hardware and Software xlvii What's New System Logging Daemon (syslogd 3 System Console 3 Port Logs 4 Viewing and Configuring System Message Logs Up a System Message 11 Gathering Information About the Problem 12 Support 12 Panic Dump and Core Dump Files 12 Trace - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 6
System Module Descriptions 14 Section I RASLog Messages Section II Audit Log Messages Chapter 2 Chapter 3 AG System Messages AG-1001 25 AG-1002 25 AG-1003 25 AG-1004 26 AG-1005 26 AG-1006 26 AG-1007 26 AG-1008 27 AG-1009 27 AG-1010 27 AG-1011 28 AG-1012 28 AG-1013 28 AG-1014 28 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 7
AUTH-1004 34 AUTH-1005 34 AUTH-1006 34 AUTH-1007 34 AUTH-1008 35 AUTH-1010 35 AUTH-1011 35 AUTH-1012 36 AUTH-1013 36 AUTH-1014 36 AUTH-1016 36 AUTH-1017 37 AUTH-1018 37 AUTH-1020 37 AUTH-1022 38 AUTH-1023 38 AUTH-1025 39 AUTH-1026 39 AUTH-1027 39 AUTH-1028 40 AUTH-1029 40 AUTH- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 8
Chapter 4 Chapter 5 BKSW System Messages BKSW-1003 47 BL System Messages BL-1000 49 BL-1001 49 BL-1002 49 BL-1003 50 BL-1004 50 BL-1006 50 BL-1007 51 BL-1008 51 BL-1009 51 BL-1010 52 BL-1011 52 BL-1012 53 BL-1013 53 BL-1014 53 BL-1015 54 BL-1016 54 BL-1017 55 BL-1018 55 BL-1019 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 9
60 Chapter 6 BLL System Messages BLL-1000 61 Chapter 7 BM System Messages BM-1001 63 BM-1002 63 BM-1003 63 BM-1004 64 BM-1005 64 BM-1006 64 BM-1007 65 BM-1008 65 BM-1009 65 BM-1010 65 BM-1053 66 BM-1054 66 BM-1055 66 BM-1056 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 10
Chapter 11 CONF System Messages CONF-1000 75 CONF-1001 75 CONF-1020 75 CONF-1021 76 CONF-1022 76 CONF-1030 76 Chapter 12 EM System Messages EM-1001 77 EM-1002 77 EM-1003 77 EM-1004 78 EM-1005 78 EM-1006 79 EM-1007 79 EM-1008 79 EM-1009 80 EM-1010 80 EM-1011 80 EM-1012 81 EM-1013 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 11
EM-1042 87 EM-1043 87 EM-1044 87 EM-1045 88 EM-1046 88 EM-1047 88 EM-1048 89 EM-1049 89 EM-1050 89 EM-1051 89 EM-1055 90 EM-1056 90 EM-1057 90 EM-1058 91 EM-1059 91 EM-1060 91 EM-1061 91 EM-1062 92 EM-1063 92 EM-1064 92 EM-1065 93 EM-1066 93 EM-2003 93 Chapter 13 ESS System - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 12
FABR-1021 105 FABR-1022 106 FABR-1023 106 FABR-1024 106 FABR-1029 107 FABR-1030 107 FABR-1031 107 FABR-1032 108 Chapter 16 FABS System Messages FABS-1001 109 FABS-1002 109 FABS-1004 109 FABS-1005 110 FABS-1006 110 FABS-1007 111 FABS-1008 111 FABS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 13
FABS-1012 112 FABS-1013 113 FABS-1014 113 FABS-1015 113 Chapter 17 FBC System Messages FBC-1001 115 Chapter 18 FCIP System Messages FCIP-1000 117 FCIP-1001 117 Chapter 19 FCMC System Messages FCMC-1001 119 Chapter 20 FCPD System Messages FCPD-1001 121 FCPD-1002 121 FCPD-1003 121 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 14
FICN-1017 129 FICN-1018 130 FICN-1019 130 FICN-1020 130 FICN-1021 131 FICN-1022 131 FICN-1023 131 FICN-1024 131 FICN-1025 132 FICN-1026 132 FICN-1027 132 FICN-1028 132 FICN-1029 133 FICN-1030 133 FICN-1031 133 FICN-1032 133 FICN-1033 134 FICN-1034 134 FICN-1035 134 FICN-1036 135 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 15
FICN-1054 139 FICN-1055 140 FICN-1056 140 FICN-1057 140 FICN-1058 141 FICN-1059 141 FICN-1060 141 FICN-1061 141 FICN-1062 142 FICN-1063 142 FICN-1064 142 FICN-1065 142 FICN-1066 143 FICN-1067 143 FICN-1068 143 FICN-1069 143 FICN-1070 144 FICN-1071 144 FICN-1072 144 FICN-1073 145 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 16
FICU-1003 151 FICU-1004 152 FICU-1005 152 FICU-1006 152 FICU-1007 153 FICU-1008 153 FICU-1009 153 FICU-1010 154 Chapter 24 FKLB System Messages FKLB-1001 155 Chapter 25 FLOD System Messages FLOD-1001 157 FLOD-1003 157 FLOD-1004 157 FLOD-1005 158 FLOD-1006 158 Chapter 26 FSPF - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 17
FSSM-1004 166 Chapter 29 FW System Messages FW-1001 167 FW-1002 167 FW-1003 168 FW-1004 168 FW-1005 168 FW-1006 169 FW-1007 169 FW-1008 169 FW-1009 170 FW-1010 170 FW-1011 170 FW-1012 171 FW-1033 171 FW-1034 171 FW-1035 172 FW-1036 172 FW-1037 172 FW-1038 173 FW-1039 173 FW- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 18
FW-1115 178 FW-1116 179 FW-1117 179 FW-1118 180 FW-1119 180 FW-1120 181 FW-1121 181 FW-1122 181 FW-1123 182 FW-1124 182 FW-1125 182 FW-1126 183 FW-1127 183 FW-1128 184 FW-1129 184 FW-1130 184 FW-1131 185 FW-1132 185 FW-1133 185 FW-1134 186 FW-1135 186 FW-1136 186 FW-1137 187 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 19
Fabric OS Message Reference 53-1000600-01 FW-1171 192 FW-1172 192 FW-1173 192 FW-1174 193 FW-1175 193 FW-1176 193 FW-1177 194 FW-1178 194 FW-1179 194 FW-1180 195 FW-1181 195 FW-1182 195 FW-1183 196 FW-1184 196 FW-1185 196 FW-1186 197 FW-1187 197 FW-1188 197 FW-1189 198 FW-1190 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 20
FW-1248 204 FW-1249 205 FW-1250 205 FW-1251 205 FW-1272 206 FW-1273 206 FW-1274 206 FW-1275 207 FW-1296 207 FW-1297 207 FW-1298 208 FW-1299 208 FW-1300 208 FW-1301 209 FW-1302 209 FW-1303 209 FW-1304 210 FW-1305 210 FW-1306 210 FW-1307 211 FW-1308 211 FW-1309 211 FW-1310 212 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 21
Fabric OS Message Reference 53-1000600-01 FW-1325 217 FW-1326 217 FW-1327 217 FW-1328 218 FW-1329 218 FW-1330 218 FW-1331 219 FW-1332 219 FW-1333 219 FW-1334 220 FW-1335 220 FW-1336 220 FW-1337 221 FW-1338 221 FW-1339 222 FW-1340 222 FW-1341 222 FW-1342 223 FW-1343 223 FW-1344 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 22
FW-1362 231 FW-1363 231 FW-1364 232 FW-1365 232 FW-1366 232 FW-1367 233 FW-1368 233 FW-1369 233 FW-1370 234 FW-1371 234 FW-1372 234 FW-1373 235 FW-1374 235 FW-1375 235 FW-1376 236 FW-1377 236 FW-1378 236 FW-1379 237 FW-1400 237 FW-1401 237 FW-1402 238 FW-1403 238 FW-1424 238 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 23
247 HAM-1005 248 HAM-1006 248 Chapter 31 HAMK System Messages HAMK-1001 251 HAMK-1002 251 HAMK-1003 251 HAMK-1004 252 Chapter 32 HIL System Messages HIL-1101 253 HIL-1102 253 HIL-1103 253 HIL-1104 254 HIL-1105 254 HIL-1106 254 HIL-1107 255 HIL - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 24
HIL-1207 257 HIL-1208 257 HIL-1301 258 HIL-1302 258 HIL-1303 258 HIL-1304 258 HIL-1305 259 HIL-1306 259 HIL-1307 259 HIL-1308 259 HIL-1309 260 HIL-1310 260 HIL-1311 260 HIL-1401 260 HIL-1402 261 HIL-1403 261 HIL-1404 261 HIL-1501 261 HIL-1502 262 HIL-1503 262 HIL-1504 262 HIL- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 25
Chapter 34 HMON System Messages HMON-1001 269 Chapter 35 HTTP System Messages HTTP-1001 271 HTTP-1002 271 HTTP-1003 271 Chapter 36 IBD System Messages IBD-1001 273 Chapter 37 IBPD System Messages IBPD-1001 275 IBPD-1002 275 IBPD-1003 275 Chapter 38 ICPD System Messages ICPD-1001 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 26
Chapter 41 ISCS System Messages ISCS-1000 285 Chapter 42 ISNS System Messages ISNS-1001 287 ISNS-1002 287 ISNS-1003 287 ISNS-1004 288 ISNS-1005 288 ISNS-1006 288 ISNS-1008 289 ISNS-1009 289 ISNS-1010 289 ISNS-1011 289 ISNS-1013 290 ISNS-1014 290 Chapter 43 FCR System Messages FCR- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 27
Fabric OS Message Reference 53-1000600-01 FCR-1022 296 FCR-1023 296 FCR-1024 297 FCR-1025 297 FCR-1026 297 FCR-1027 298 FCR-1028 298 FCR-1029 298 FCR-1030 299 FCR-1031 299 FCR-1032 299 FCR-1033 299 FCR-1034 300 FCR-1035 300 FCR-1036 300 FCR-1037 300 FCR-1038 301 FCR-1039 301 FCR- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 28
315 LOG-1002 315 LOG-1003 316 Chapter 47 LSDB System Messages LSDB-1001 317 LSDB-1002 317 LSDB-1003 317 LSDB-1004 318 Chapter 48 MFIC System Messages MFIC-1001 319 xxviii Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 29
MFIC-1002 319 MFIC-1003 320 Chapter 49 MPTH System Messages MPTH-1001 321 MPTH-1002 321 MPTH-1003 321 Chapter 50 MQ System Messages MQ-1004 323 Chapter 51 MS System Messages MS-1001 325 MS-1002 325 MS-1003 326 MS-1004 326 MS-1005 327 MS-1006 327 MS-1008 327 MS-1009 328 MS-1021 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 30
PDTR System Messages PDTR-1001 343 PDTR-1002 343 Chapter 56 PLAT System Messages PLAT-1000 345 PLAT-1001 345 PLAT-1002 345 Chapter 57 PORT System Messages PORT-1003 347 PORT-1004 347 PORT-1005 348 xxx Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 31
Chapter 58 PS System Messages PS-1000 349 PS-1001 349 PS-1002 349 PS-1003 350 PS-1004 350 PS-1005 350 Chapter 59 PSWP System Messages PSWP-1001 351 PSWP-1002 351 PSWP-1003 351 Chapter 60 RAS System Messages RAS-1001 353 RAS-1002 353 RAS-1004 353 RAS-1005 353 RAS-1006 354 RAS-2001 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 32
362 RPCD-1005 362 RPCD-1006 362 RPCD-1007 362 Chapter 63 RTWR System Messages RTWR-1001 363 RTWR-1002 363 RTWR-1003 364 Chapter 64 SAS System Messages SAS-1001 365 Chapter 65 SCN System Messages SCN-1001 367 Chapter 66 SEC System Messages SEC-1001 369 SEC-1002 369 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 33
Fabric OS Message Reference 53-1000600-01 SEC-1032 375 SEC-1033 375 SEC-1034 375 SEC-1035 376 SEC-1036 376 SEC-1037 376 SEC-1038 376 SEC-1040 377 SEC-1041 377 SEC-1042 377 SEC-1043 378 SEC-1044 378 SEC-1045 378 SEC-1046 379 SEC-1049 379 SEC-1050 379 SEC-1051 380 SEC-1052 380 SEC- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 34
SEC-1079 386 SEC-1080 387 SEC-1081 387 SEC-1082 387 SEC-1083 388 SEC-1084 388 SEC-1085 388 SEC-1086 389 SEC-1087 389 SEC-1088 389 SEC-1089 390 SEC-1090 390 SEC-1091 390 SEC-1092 391 SEC-1093 391 SEC-1094 391 SEC-1095 392 SEC-1096 392 SEC-1097 392 SEC-1098 393 SEC-1099 393 SEC- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 35
Fabric OS Message Reference 53-1000600-01 SEC-1121 399 SEC-1122 399 SEC-1123 399 SEC-1124 399 SEC-1126 400 SEC-1130 400 SEC-1135 400 SEC-1136 401 SEC-1137 401 SEC-1138 401 SEC-1139 402 SEC-1142 402 SEC-1145 402 SEC-1146 403 SEC-1153 403 SEC-1154 403 SEC-1155 404 SEC-1156 404 SEC- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 36
SEC-1182 410 SEC-1183 410 SEC-1184 411 SEC-1185 411 SEC-1186 411 SEC-1187 412 SEC-1188 412 SEC-1189 412 SEC-1190 413 SEC-1191 413 SEC-1192 413 SEC-1193 414 SEC-1194 414 SEC-1195 414 SEC-1196 415 SEC-1197 415 SEC-1198 415 SEC-1199 416 SEC-1200 416 SEC-1201 416 SEC-1202 417 SEC- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 37
SEC-1312 422 SEC-1313 422 SEC-1314 423 SEC-1315 423 SEC-1316 423 SEC-1317 424 SEC-1318 424 SEC-1319 424 SEC-1320 424 SEC-1321 425 SEC-1322 425 SEC-1323 425 SEC-1324 426 SEC-1325 426 SEC-1326 426 SEC-1327 427 SEC-1328 427 SEC-1329 427 SEC-1330 427 SEC-1331 428 Chapter 67 SNMP - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 38
SULB-1003 433 SULB-1004 434 SULB-1005 434 SULB-1006 434 SULB-1007 434 SULB-1008 435 SULB-1009 435 SULB-1010 441 SULB-1011 441 SULB-1017 441 SULB-1018 442 SULB-1020 442 SULB-1021 442 SULB-1022 443 SULB-1023 443 SULB-1024 443 SULB-1025 444 SULB-1026 444 SULB-1030 444 SULB-1031 444 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 39
Chapter 71 SYSC System Messages SYSC-1001 451 SYSC-1002 451 SYSC-1003 452 SYSC-1004 452 SYSC-1005 452 Chapter 72 SYSM System Messages SYSM-1001 453 SYSM-1002 453 SYSM-1003 453 SYSM-1004 454 SYSM-1005 454 SYSM-1006 454 SYSM-1007 454 Chapter 73 TRCE System Messages TRCE-1001 455 TRCE - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 40
Chapter 75 TS System Messages TS-1001 463 TS-1002 463 TS-1006 464 TS-1007 464 TS-1008 465 Chapter 76 UCST System Messages UCST-1003 467 UCST-1007 467 UCST-1020 467 Chapter 77 UPTH System Messages UPTH-1001 469 Chapter 78 WEBD System Messages WEBD-1001 471 WEBD-1002 471 WEBD-1003 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 41
ZONE-1013 480 ZONE-1014 481 ZONE-1015 481 ZONE-1017 481 ZONE-1018 482 ZONE-1019 482 ZONE-1022 483 ZONE-1023 483 ZONE-1024 483 ZONE-1026 484 ZONE-1027 484 ZONE-1028 485 ZONE-1029 485 ZONE-1030 485 ZONE-1031 486 ZONE-1032 486 ZONE-1033 486 ZONE-1034 487 ZONE-1035 487 ZONE-1036 487 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 42
AUTH-3006 492 AUTH-3007 493 AUTH-3008 493 Chapter 82 AUDIT CONF System Messages CONF-1000 495 CONF-1020 495 CONF-1022 495 Chapter 83 AUDIT HTTP System Messages HTTP-1002 497 HTTP-1003 497 Chapter 84 AUDIT SEC System Messages SEC-3001 499 SEC-3002 499 SEC-3003 500 SEC-3004 500 SEC- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 43
SEC-3025 507 SEC-3026 507 SEC-3027 508 SEC-3028 508 SEC-3029 508 SEC-3030 509 SEC-3031 509 SEC-3032 509 SEC-3033 510 SEC-3034 510 SEC-3035 510 SEC-3036 510 SEC-3037 511 SEC-3038 511 SEC-3039 511 SEC-3044 512 SEC-3045 512 SEC-3046 512 SEC-3047 512 SEC-3048 513 SEC-3049 513 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 44
SULB-1021 525 SULB-1023 525 SULB-1024 526 SULB-1026 526 SULB-1030 526 SULB-1031 527 SULB-1032 527 SULB-1033 527 SULB-1034 527 SULB-1035 528 SULB-1037 528 Chapter 87 AUDIT ZONE System Messages ZONE-3001 529 ZONE-3002 529 ZONE-3003 530 ZONE-3004 530 ZONE-3005 530 ZONE-3006 531 ZONE- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 45
ZONE-3025 537 Fabric OS Message Reference xlv 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 46
xlvi Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 47
in the software from Brocade Fabric OS v5.3.0 to 6.0.0, supporting the following platforms: • Brocade 200E, 4012, 4016, 4018, 4020, 4024 switches • Brocade 3250 switch • Brocade 3850 switch • Brocade 3900 switch • Brocade 4100, 4900, 5000, 7500, AP 7600 switches • Brocade 24000 director Fabric OS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 48
• Brocade 48000 director • FA4-16 blade • FC10-6 blade In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 49
this guide are . Otherwise, this manual specifically notes those to hardware, firmware, software, or data SAN)-specific terms, visit the Storage Networking Industry Association online dictionary at http://www.snia.org/education/dictionary. Additional Information This section lists additional Brocade - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 50
problems before they become costly failures. ISL Trunking Brocade® ISL Trunking is an optional software product available for all Brocade 2 and 4 Gbit/sec Fibre Channel switches and directors. This technology is ideal for optimizing performance and simplifying the management of multi-switch SAN - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 51
32 Gbit/sec. Automatically groups SAN fabric-connected devices into logical zones that restrict access to "member" devices in the zone. Advanced Zoning uses hardware enforcement at both the port Help Contact your switch support supplier for hardware, firmware, and software support, including product - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 52
front of the chassis, on the wall to the left of the ports. 3. World Wide Name (WWN) - Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, AP7600 switches and Brocade 24000, and 48000 directors: Provide the license ID. Use the licenseIdShow command to display the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 53
guide supports Fabric OS v6.0.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized first by event type, reliability, availability, and serviceability • Port Logs 4 SYSTEM ERROR MESSAGE LOGGING The RASLog service generates - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 54
errClear command. The sequence number is persistent across power cycles and switch reboots. • By default, the errDump and support post-event audtis and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware downloads - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 55
propagated to the active CP counters. For information on configuring syslogd functionality, refer to the Fabric OS Administrator's Guide. SYSTEM CONSOLE The system console displays messages only through the serial port. If you log in to a switch through the Ethernet port or modem port, you will not - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 56
log of all port activity. Each switch or logical switch maintains a log file for each port. Port logs are circular buffers that can save up to 8000 entries per logical switch. When the log is full, the newest log entries overwrite the oldest log entries. Port logs capture switch-to-device, device - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 57
(Power-On Self-Test) configuration. errClear Clears all error log messages for all switch port log. Port log events are described by the portLogEventShow command. setVerbose Sets the verbose level of a particular module within the Fabric OS. supportFtp Sets, clears, or displays support - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 58
(active CP only) information for the local CP and then transfers the files to an FTP server. The operation can take several minutes. supportShow Executes a list of diagnostic and error display commands. This output is used by your switch service provider to diagnose and correct problems with - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 59
, HA State out of sync Type to continue, Q to stop: 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible e. Reason: Configured port speed. Type to continue, Q to stop: CLEARING THE SYSTEM MESSAGE LOG To clear the system message log for a particular - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 60
is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 3. Enable the audit feature: switch:admin> auditcfg --enable Audit filter is the message was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. Displays - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 61
power cycles and switch 16 characters in length. Run either the chassisName command to name the chassis or the switchName command to rename the logical switch. Error Description This field displays a text string explaining the error encountered and providing parameters supplied by the software - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 62
switch. The RASLog subsystem will support an internationalized timestamp format base the following: Zone Security Configuration Firmware Fabric User ID Identifies the switch name. This field displays the defined switch name or the chassis name of the switch. This value is truncated if it is over 16 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 63
= ERROR 3 = WARNING 4 = INFO Critical-level messages indicate that the software has detected serious problems that will cause a partial or complete failure of a subsystem if not corrected immediately; for example, a power supply failure or rise in temperature must receive immediate attention. Error - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 64
port (console) logs available? 12. Which CP was master? (only applicable to the Brocade DCX, 12000, 24000, or 48000) 13. What and when were the last actions or changes made to the system? SUPPORT Fabric OS create a number of files that can help support personnel troubleshoot and diagnose a problem - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 65
Message 1 The software watchdog process (SWD) is responsible for monitoring daemons critical to the function of a healthy switch. The SWD holds and core files are intended for support personnel use only. TRACE DUMPS The Fabric OS produces trace dumps when problems are encountered within Fabric OS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 66
lists to all switches in the fabric. FABS Fabric OS system driver module. FBC Firmware blade compatibility errors with control processor (CP). FCIP Fibre Channel over IP port configuration messages. FCMC FCPD FCPH FCR Fibre Channel miscellaneous messages relate to problems with the physical - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 67
the switch nondisruptively during failures and software upgrades. These facilities include version negotiation, state information transfer, and internal synchronization functions, enabling the transition from standby to active operation. FSS is defined both as a component and a service. A component - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 68
software Blade Manager (bmd) • Common Access Layer (cald) • Diagnostics daemon (diagd) • Environment Monitor (emd) • EVM daemon (evmd) • Exchange Service Support secd) • SNMP daemon (snmpd) • Time Service daemon (tsd) • TRACE daemon (traced) status of port links. This port (FICON-CUP service routine - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 69
secondary partition and from the active CP blade to the standby CP blade. These messages indicate panic dump trace files have been created. This message indicates hardware problems. PORT error messages refer to the front-end user ports on the switch. Front-end user ports are directly accessible by - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 70
any problems associated with the zoning features, including commands associated with aliases, zones, and configurations. NOTE Any reference seen in a system message to slot 0 is a reference to the blade within the switch platform, for example: Brocade DCC contain FC8-48, FC9-32, and FC8-16 blades - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 71
RASLog Messages This section provides the RASLog messages, including: • AG System Messages 25 • AUTH System Messages 33 • BKSW System Messages 47 • BL System Messages 49 • BLL System Messages 61 • BM System Messages 63 • C2 System Messages 69 • CDR System Messages 71 • CER System Messages - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 72
325 • NBFS System Messages 331 • NS System Messages 333 • PDM System Messages 335 • PDTR System Messages 343 • PLAT System Messages 345 • PORT System Messages 347 • PS System Messages 349 • PSWP System Messages 351 • RAS System Messages 353 • RCS System Messages 357 • RPCD System Messages - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 73
• TRCK System Messages 461 • TS System Messages 463 • UCST System Messages 467 • UPTH System Messages 469 • WEBD System Messages 471 • ZOLB System Messages 475 • ZONE System Messages 477 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 74
- HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 75
Audit Log Messages This section provides the Audit messages, including: • AUDIT AUTH System Messages 491 • AUDIT CONF System Messages 495 • AUDIT HTTP System Messages 497 • AUDIT SEC System Messages 499 • AUDIT SNMP System Messages 515 • AUDIT SULB System Messages 517 • AUDIT ZONE System - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 76
- HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 77
. • Some blades and ports in a switch may not support NPIV. NPIV functionality cannot be enabled on such ports and they will not respond to NPIV requests. Refer to the Access Gateway Administrator Guide, Appendix B for specific AG compatibility requirements. • On non-Brocade switches, refer to - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 78
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AG-1005 Message , [AG-1005 not received for the N_Port connected to the fabric. Indicates that the N_Port connected to the fabric switch is not online. The specified - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 79
service provider. Severity WARNING AG-1009 Message , [AG-1009], ,, WARNING, , Sending FLOGI failed on N_Port . Probable Cause Failure sending Fabric Login (FLOGI) request from the Access Gateway to the fabric switch. Recommended Action Please - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 80
>, [AG-1011], ,, WARNING, , Sending FDISC failed on N_Port . Probable Cause Indicates failure of sending the discover F_Port service parameter request from the Access Gateway to the fabric switch. Recommended Action Please check the configuration of the fabric - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 81
then run the supportSave command and contact your switch service provider. Severity WARNING AG-1016 Message to other N_Port(s). Probable Cause Indicates that the specified N_Port has failed to come online. All F_Port(s) mapped to this N_Port are being failed over to other active - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 82
, [AG-1019], ,, WARNING, , Unable to failover N_Port . No other N Port in port group: is online. Probable Cause Failover across port groups is not supported. Recommended Please check whether or not an alternate N_Port is configured in this - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 83
AG-1023 2 Probable Cause Indicates that the specified F_Port is failing over to its preferred N_Port. Recommended Please run ag --mapshow to display the updated F_Port to N_Port mapping. Action Severity INFO AG-1023 Message , [AG-1023], ,, INFO, , F_Port - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 84
2 32 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 85
Retry the secAuthSecret command. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 86
run the supportSave command and contact your switch service provider. Severity WARNING AUTH-1007 Message Probable Cause , [AUTH-1007], ,, ERROR, , The proposed authentication protocol(s) are not supported: port . Indicates that the proposed - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 87
sure the local switch supports the specified protocols: problem with the Secure Fabric OS. Recommended Action Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 88
supportSave command and contact your switch service provider. Severity WARNING AUTH-1014 Message , [AUTH-1014], , FFDC, ERROR, , Invalid port value to : port . Probable Cause Indicates an internal problem with the Secure Fabric OS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 89
the supportSave command and contact your switch service provider. Severity ERROR AUTH-1018 Message , [AUTH-1018], ,, ERROR, , Invalid value to check protocol type: port . Probable Cause Indicates an internal problem with the Secure Fabric OS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 90
run the supportSave command and contact your switch service provider. Severity INFO AUTH-1022 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 91
port . Probable Cause Indicates that the authentication process failed to select an authentication value (that is, DH Group, hash value, or protocol type) from a receiving payload for the specified authentication phase. This indicates that the local switch does not support the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 92
your switch service provider. port number>, retval . Probable Cause Indicates that the authentication process failed to get a particular authentication value at certain phase. Data type is the payload or structure that failed to get memory. Recommended Action Usually this problem - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 93
replay attacks. Recommended Action Usually this problem is transient. The authentication might fail. switch service provider. Severity ERROR AUTH-1033 Message , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 94
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1035 Message , [AUTH-1035 port . Probable Cause Indicates that the switch received an unexpected authentication message. Recommended Action Usually this problem - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 95
service provider. Severity ERROR AUTH-1039 Message Probable Cause , [AUTH-1039], ,, ERROR, , Neighboring switch has conflicting authentication policy: Port disabled. Indicates that the neighboring switch has a conflicting authentication - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 96
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1042 Message Probable Cause , [AUTH-1042], ,, ERROR, , Port has been disabled, because authentication failed with code ' - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 97
command and contact your switch service provider. Severity ERROR AUTH authentication policy manually using the port>. Disabling port . Probable Cause Indicates authentication has timed out after multiple retries. The specified port has been disabled as a result. This problem - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 98
3 AUTH-1044 46 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 99
is found, run supportFtp to send all core files to a secure server location. Copy the error message and any core file information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 47 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 100
4 BKSW-1003 48 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 101
correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Note that any reference seen to slot 0 is a reference to the blade within the switch platform, e.g.,Brocade 7500 and AP7600 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 102
Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 103
1007 5 Probable Cause Indicates that the errors (mostly synchronization errors) on this blade are harmless. Probably, the standby control processor (CP) blade connected to the active CP blade has experienced transitory problems. Recommended Use the haShow command to verify that the standby CP is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 104
(SFP), or device attached to the specified port. Run the systemVerification command to verify that the blade or switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 105
factor pluggable (SFP), or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace the blade. Severity ERROR BL-1014 Message Probable Cause , [BL - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 106
the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade DCX, 24000, and 48000, replace the blade field-replaceable unit (FRU). • On the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 107
blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power slot has completed initializing the ports. Recommended No action is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 108
one or more of the internal ports was not online. The switch is faulted. Recommended Action Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 109
Action Reboot or power cycle the blade. If the message persists, replace the blade. Severity CRITICAL BL-1024 Message , [BL-1024], ,, INFO, , All ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 110
Recommended Action Reboot or power cycle the switch. If the message persists, replace the switch. Severity CRITICAL BL-1029 Message , [BL-1029], ,, INFO, , All ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 111
Indicates that back-end (non-user) ports have not come ONLINE within time limit. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 112
waiting for disable messages from the user ports after disabling the ports. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 113
], , FFDC, CRITICAL, , ASIC driver detected Slot port as faulty (reason: ) Probable Cause Indicates that a blade regulation problem was reported on the specified slot number. The blade is faulted. The possible reason codes are as - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 114
6 BLL-1000 If the message persists, replace the blade. Severity CRITICAL 62 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 115
to determine whether a non-disruptive firmware download is supported between the versions. As the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If needed, send the AP blade back to the factory for a firmware update. Severity ERROR BM-1002 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 116
. On the Brocade Action DCX, 7500 or 7600, switch off and on all primary power in order to power-cycle the unit. Severity WARNING BM-1006 Message , [BM-1006], ,, INFO, , Blade is not configured. Persistently disabling all ports for blade in slot - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 117
commands or reseat the affected blade. On the Brocade Action 7500 or 7600, switch off and on all primary power in order to power-cycle the unit. Severity WARNING BM-1010 Message , [BM-1010], ,, INFO, , Resetting port configuration and linkcost for all - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 118
On the Brocade 7500 or 7600, switch off and on all primary power to power-cycle the unit. Action Severity WARNING BM-1054 Message , [BM-1054], ,, INFO, , AP firmware is not consistent with system firmware . Auto-leveling - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 119
under a different mode. Recommended Configure the switch to persistently enable all ports. Action Severity INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue firmwaredownload to recover. Probable Cause - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 120
7 BM-1058 68 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 121
name>, Port port fault (the configured speed may not be supported by the ports on the blade/switch will be disrupted. Recommended For a bladed system, perform slotpoweroff and slotpoweron on the blade to recover the system. For Action a non-bladed system, perform fastboot on the switch - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 122
,, ERROR, , Rate limit configuration is not effective on S() user port because QoS license is not present. Probable Cause Indicates that the switch does not have the QoS license added. Rate Limit is a licensed feature and requires QoS license - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 123
, , Port chip faulted due to internal error. Probable Cause Internal error. Recommended For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover Action the system. For a non-bladed system, perform fastBoot on the switch to recover the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 124
specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Whenever this error occurs, reboot the system at the next maintenance window. If the problem Action persists, replace the blade. Severity ERROR 72 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 125
Cause Indicates that the high-availability (HA) synchronization between the active and standby control processors (CPs) is broken, because there is downlevel firmware loaded on the standby CP. The standby CP does not support the Advanced Performance Tuning module when the fibre connectivity (FICON - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 126
10 CER-1001 74 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 127
operation was initiated and completed successfully. The message string that follows is a description of the class of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description. Recommended No action is required. Action Severity - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 128
to be disabled. Recommended Disable the switch and try to download configuration again. Action Severity INFO CONF-1030 Message , [CONF-1030], ,, WARNING, , Configuration database full, data not committed (key:. Probable - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 129
range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Run the fanShow faulted. Recommended Action On Brocade 24000 and 48000, try reseating the specified FRU. Reboot or power cycle the switch. Fabric OS Message Reference 77 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 130
and an optional number to identify the unit, slot, or port. The Brocade 3250 has one power supply and three fans, and the Brocade 3850 has two power supplies and four fans. Values for the individual fans and power supplies for these switches might display, but these parts cannot be replaced: the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 131
the faulty slot or the switch for nonbladed switches. Recommended Action There is most likely a voltage hardware problem on the blade or motherboard of the switch. For the Brocade DCX, 24000 and 48000, replace the blade field-replaceable unit (FRU). For the Brocade 3900 replace the motherboard FRU - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 132
FRU. Refer to the Brocade 48000 Hardware Reference Manual for more information about chassisConfig modes and supported blades. Severity CRITICAL EM-1010 to be powered up after four seconds. Recommended Try reseating the blade. If this fails to correct the error, replace the blade. Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 133
serious internal Fabric OS configuration or hardware problems on the switch. Recommended Action On Brocade DCX, 24000 and 48000, try reseating the indicated field-replaceable unit (FRU). If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 134
Recommended Monitor the switch. If the problem persists, a reBoot or power cycle is required to resolve the Action problem. Severity WARNING EM FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING EM-1017 Message , [EM-1017 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 135
CP) blade is supported by the firmware The problems were encountered when the software attempted to problem. The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or port. Recommended Action If the message persists, reboot or power cycle the switch - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 136
is being retried. Probable Cause Indicates that the I2C bus had problems and a timeout occurred. Recommended Action This is often a 48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 137
problems. Refer to the Fabric OS Command Reference for more information on this command. If the message persists, replace the FRU. Severity ERROR EM-1035 Message , [EM-1035], ,, ERROR, , 2 circuit paired Power Supplies are faulty, please check the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 138
. Recommended Action Reseat the FRU card. If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this command. If the message persists - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 139
responding to commands and should be replaced. Action Severity WARNING EM-1044 Message , [EM-1044], ,, WARNING, , Can't power on , its logical switch is shut down Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 140
is indicating a predicted failure. If new_state is Down (not enough power), a newly inserted port blade was not powered on because there was not enough power available. Recommended The Brocade 24000 requires only a single power supply for a fully populated chassis; however, you Action should always - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 141
access to the field-replaceable unit (FRU) has become available again. Recommended The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is Action displayed. Severity INFO EM-1049 Message , [EM-1049], ,, INFO, , FRU - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 142
be run at the configured port speed. If the port media is extended long wavelength, move it to a port that can support the heat generated. Severity the switch does not reach the reset threshold for the switch/blade. If the reset threshold is reached on the switch/blade, the switch/blade will - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 143
with your switch type. Action Severity CRITICAL EM-1060 Message , [EM-1060], ,, WARNING, , Stopping synchronization of the system due to blade incompatibility with software version on standby CP. Probable Cause A blade in the system is not supported by - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 144
Fault reason>. Probable Cause The blade is power off since a hardware (HW) application specific integrated circuit (ASIC) ERROR was detected, and the user has selected to power off the problem blade when such a condition occurred. Recommended Contact support. Action Severity CRITICAL 92 Fabric - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 145
The previously incompatible Fabric OS or Storage Application Services (SAS) firmware have been upgraded and are now compatible. non-bladed systems. Recommended Action On bladed systems, try reseating the specified FRU. On nonbladed switches, reboot or power cycle the switch. If the problem - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 146
12 EM-2003 94 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 147
Action Discontinue the firmware download, identify the downlevel switch or switches that do not support the Coordinated HotCode protocol, and upgrade the downlevel switches. Then, restart the firmware download on this switch. Note that upgrading a downlevel Brocade switch in a mixed interop - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 148
. Probable Cause During the Coordinated HotCode protocol, a switch in the fabric has rejected the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message. Recommended - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 149
id.> Probable Cause The event could not be sent to the remote proxy because the remote proxy switch cannot be reached through in-band. Recommended Please make sure that the specified remote domain is present in the fabric. Action Severity WARNING Fabric OS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 150
14 EVMD-1001 98 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 151
Cause Indicates that an internal link service (ILS) information unit of invalid size has been received. The neighbor switch has sent an invalid sized payload. Recommended Action Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch to view the error log for - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 152
switch service provider. Severity WARNING FABR-1004 Message , [FABR-1004], ,, WARNING, , port: - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 153
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1007 Message , [FABR-1007], information unit. This message is rare and usually indicates a problem with the Fabric OS. Recommended Action In case of severe - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 154
message is rare and usually indicates a problem with the Fabric OS. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FABR-1011 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 155
not enough memory in the switch for the fabric module to allocate. This message is rare and usually indicates a problem with the Fabric OS. switch service provider. Severity CRITICAL FABR-1014 Message , [FABR-1014], , FFDC, ERROR, , Port - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 156
>, [FABR-1016], ,, WARNING, , ficonMode is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface command. Recommended No action is required. Action Severity WARNING FABR-1017 Message , [FABR-1017], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 157
, FFDC, CRITICAL, , Critical fabric size () exceeds supported configuration (). Probable Cause Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified limit to the number of - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 158
changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1023 Message , [FABR-1023], ,, INFO, , Fabric size is within supported configuration (). Fabric limit timer ( - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 159
In both of the previous modes, the buffer credits are fixed, based on the port configuration information. In this mode, the buffer credits are negotiated from port exceeded. Probable Cause Indicates that fabric exhausted the maximum number of retries sending internal link service (ILS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 160
>running an unsupported FOS version v2.x has joined the fabric. Probable Cause Indicates that a switch with an unsupported Fabric OS version 2.x has joined the fabric. Recommended Remove the switch with the unsupported Fabric OS version 2.x from the fabric. Action 108 Fabric OS Message Reference - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 161
Chapter FABS System Messages 16 FABS-1001 Message < problem has been detected by the software. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 162
which could be any whole number. Recommended Action Reboot or power cycle the active CP (for modular systems) or the switch (for single-board systems). If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1006 Message , [FABS-1006 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 163
16 FABS-1007 FABS-1007 Message , [FABS-1007], ,, WARNING, < internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 164
an unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1011 Message , [FABS-1011], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 165
enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR Fabric OS Message Reference 113 53-1000600 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 166
16 FABS-1015 114 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 167
Action The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 168
17 FBC-1001 116 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 169
, FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 170
18 FCIP-1001 118 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 171
allocate new memory for an information unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message Reference 119 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 172
19 FCMC-1001 120 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 173
the firmware on the device controller on the specified port has a defect. Action Check with the device vendor for a firmware upgrade not supported in this port type Probable Cause Private devices will not respond to the switch port login (PLOGI) during probing. Recommended Action The Brocade DCX, - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 174
20 FCPD-1003 122 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 175
". This function creates a Fibre Channel driver instance. The failed function call is "kmalloc_wrapper failed". This function call is for kernel memory allocation. Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 176
21 FCPH-1001 124 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 177
: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to. HP - Host Port number: This is a 1 byte hexidecimal value that represents the switch port of the switch that the FICON Channel is directly connected to. DD - Device Domain - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 178
FICN-1005], ,, INFO, , FICON GEPort TID Feature Change verified Xrc . Probable Cause User changed the configuration manually. Recommended No action is required. Action Severity INFO FICN-1006 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 179
as a part of path recovery. Recommended If there was a job failure associated with this event, please contact your vendor's customer support Action for assistance. Severity ERROR FICN-1009 Message , [FICN-1009], ,, INFO, , DevIng:CmdReject Sense Data - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 180
FICON Channel. Recommended If there was a job or IO failure associated with this event, please contact your vendor's customer Action support for assistance. Severity INFO FICN-1011 Message , [FICN-1011], ,, ERROR, , DevDiskIng:XRC Incorrect RRS SeqNum - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 181
22 FICN-1014 Recommended If there was a job or IO failure associated with this event, please contact your vendor's customer Action support for assistance. Severity INFO FICN-1014 Message , [FICN-1014], ,, INFO, , DevEgr:Device level exception flag found - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 182
FICON Control Unit sent a frame that cannot be associated with a FICON Control Unit CUADDR. Recommended Please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1019 Message , [FICN-1019], ,, ERROR, , DevTapeEgr:AS Link - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 183
associated with this event, please contact your vendor's Action customer support for assistance. Severity ERROR FICN-1022 Message , [ The FICON channel issued a Selective Reset for a device that was active in emulation. Recommended If there was an unexpected job failure associated - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 184
with this event, please contact your Action vendor's customer support for assistance. Severity ERROR FICN-1025 Message , [FICN the frame that included the Device Level Exception>. Probable Cause An active emulation device delivered a Device Level Exception frame to the emulation - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 185
22 FICN-1029 Probable Cause An active emulation device received a cancel operation from the FICON channel. Recommended If there was an unexpected job failure or IO Error associated with this event, please contact your Action vendor's customer support for assistance. Severity ERROR FICN-1029 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 186
This indicates that the channel side noted corruption from the device/CU side processing. Recommended Please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1035 Message , [FICN-1035], ,, WARNING, , HostIng:FICON System - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 187
No action is required. This is a part of the FICON path activation. Action Severity INFO FICN-1038 Message , [FICN-1038], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 188
0xB=0x. Probable Cause An active disk emulation device received a FICON Purge Path from the channel. Recommended with this event, please contact your Action vendor's customer support for assistance. Severity ERROR FICN-1041 Message , [FICN - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 189
CU or network errors can cause Selective Reset. Recommended If this was an unexpected event, please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1044 Message , [FICN-1044], ,, ERROR, , HostTapeIng:FICON Selective Reset - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 190
an internal emulation error and should not be encountered. Recommended This is an unexpected event, please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1048 Message , [FICN-1048], ,, WARNING, , DevDiskEgr:FICON Cancel - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 191
to break an XRC session with the extended DASD device. Recommended If this was an unexpected event, please contact your vendor's customer support for assistance. Action Severity INFO FICN-1053 Message , [FICN-1053], ,, INFO, , XRC Withdraw From Session - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 192
break an XRC session with the extended DASD device. Recommended If this was an unexpected event, please contact your vendor's customer support for assistance. Action Severity WARNING FICN-1055 Message , [FICN-1055], ,, WARNING, , XRC All Devices Suspended - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 193
could not be created and sent to an LPAR. Recommended This is an unexpected event, please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1060 Message , [FICN-1060], ,, ERROR, , Error return from fcFwdPrcEgressFrame - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 194
for an active emulation exchange. Recommended This is an unexpected event, please contact your vendor's customer support for assistance. Number> VEPort= from SID=0x to DID=0x. Probable Cause An abort operation has been received - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 195
CH exchange. Recommended If there were associated IO errors at the same time as this event, please contact your vendor's Action customer support for assistance. Severity ERROR FICN-1068 Message , [FICN-1068], ,, ERROR, , Ingress Abort:Oxid=0x - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 196
device or error status (including Unit Check 0x02) is received from an active emulation device. Recommended The end of tape is a normal event during pipelining messages with this event, please contact your vendor's customer support for assistance. Severity INFO FICN-1071 Message , [ - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 197
22 FICN-1073 FICN-1073 Message , [FICN-1073], ,, INFO, , HostTapeIngr:Unloaded:Path=:states=0x:cmds=0x:status=0x - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 198
22 FICN-1076 FICN-1076 Message , [FICN-1076], ,, INFO, , HostTapeIngr:ReadCpReport:Path=:Emuls=0x:Cmds=0x - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 199
channel indicates that the channel does not have a path established to the CU. Recommended This is normally an unexpected event, please contact your vendor's customer support for Action assistance. Severity WARNING Fabric OS Message Reference 147 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 200
= Domain=0x Port=0x. Probable Cause An attached port which had an FICON emulated path established has logged out from the switch. Recommended This may be an unexpected event, please contact your vendor's customer support for assistance. Action Severity - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 201
>,tunnel Id=. Probable Cause A FICON FCIP tunnel has been terminated to the peer switch. Recommended If this is an unexpected event, please contact your vendor's customer support for assistance. Action Severity ERROR Fabric OS Message Reference 149 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 202
22 FICN-1086 150 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 203
The error variable is an internal error number. Recommended Action If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference for - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 204
using the ficonCupSet command. Refer to the Fabric OS Administrator's Guide for information on core PID mode and the Fabric OS Command within the fibre connectivity control unit port (FICON-CUP) daemon failed. Recommended Download a new firmware version using the firmwareDownload command. Refer - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 205
transient problem. Recommended Action If the message persists, check the memory usage on the switch, run the supportSave command and contact your switch service provider. Severity WARNING FICU-1008 Message < to port address conflict or port address being reserved for CUP management port. - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 206
Server mode (fmsMode) was not enabled because the specified port has an address conflict with the CUP management port is in use. Recommended Use the portDisable command to disable the specified port to avoid the port address conflict. Action Severity WARNING 154 Fabric OS Message Reference - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 207
WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 208
24 FKLB-1001 156 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 209
, FFDC, WARNING, , Unknown LSR type: port , type Probable Cause Indicates that the link Probable Cause Indicates that the LSU size exceeds what the system can support. Recommended Reduce the number of switches in the fabric or reduce the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 210
25 FLOD-1005 FLOD-1005 Message , [FLOD-1005], ,, WARNING, , Invalid received domain ID: Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended No action is required; the LSR is discarded. Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 211
Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended No action is required. Action Severity ERROR FSPF-1002 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 212
than 0 is incompatible in a fabric of Brocade switches. Disconnect the offending switch. Severity ERROR FSPF-1006 Message , [FSPF-1006], ,, ERROR, , FSPF Version not supported, input port = Probable Cause Indicates that the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 213
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSS-1002 Message , [FSS-1002], ,, WARNING, , Component () sending too - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 214
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR FSS-1005 Message , [FSS-1005], ,, WARNING, , FSS read failure Probable Cause - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 215
active CP and standby CP (interface eth1) by issuing net commands such as ifconfig eth1 (as root) or run supportShow/supportSave to validate the network configuration; then try to restore the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 216
27 FSS-1007 164 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 217
on the active CP and try resynchronizing the HA state. If the HA state does not become synchronized, run the haDump command to diagnose the problem. If the problem persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 218
>, Incompatible software version in HA synchronization. Probable Cause Indicates that the active control processor (CP) and the standby CP in a dual CP system are running firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive. In a non-bladed system - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 219
means that the fans and airflow of a switch are functioning normally. Verify that the location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Severity WARNING Fabric OS Message Reference 167 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 220
> . Probable Cause Indicates that the internal temperature of the switch has changed from a value outside of the acceptable range to a that the speed of the fan has changed. Fan problems typically contribute to temperature problems. Recommended Action No action is required. Respond to this - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 221
is . Probable Cause Indicates that the speed of the fan has fallen below the low boundary. Fan problems typically contribute to temperature problems. Recommended Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan Action field-replaceable unit - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 222
that it is seated correctly in the chassis. Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. Severity INFO FW-1010 Message , [FW-1010], ,, WARNING, , , is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 223
>, is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the power supply counter changed from a value outside of the acceptable range to a value within the acceptable range. Recommended No action is required. Respond - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 224
, , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The receive performance area measures the amount of incoming laser to help you - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 225
name>, , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has fallen below the low boundary. The receive performance area measures the amount of incoming - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 226
Label>, is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has fallen below the low boundary. The transmit performance area measures the amount of outgoing laser - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 227
is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed from a value outside of the acceptable range to a value within the acceptable range - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 228
29 FW-1047 FW-1047 Message , [FW-1047], ,, WARNING, , , is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 229
29 FW-1050 FW-1050 Message , [FW-1050], ,, WARNING, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 230
SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 231
fabric reconfigurations has changed. The following actions can cause a fabric reconfiguration: • two switches with the same domain ID have connected to one another. • two fabrics have error and might not require troubleshooting. Severity INFO Fabric OS Message Reference 179 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 232
below the low boundary. The following occurrences can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to one another. • Two fabrics have a transient error and might not require troubleshooting. Severity INFO 180 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 233
changes has changed. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 234
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended No action is required - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 235
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. A low number of segmentation errors - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 236
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended No action is required - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 237
Low=). Current value is . Probable Cause Indicates that the number of fabric logins has changed. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. Recommended No action is required. Respond to this message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 238
Current value is . Probable Cause Indicates that the number of fabric logins has fallen below the low boundary. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. A low number of fabric logins means that the fabric is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 239
fallen below the low boundary. SFP state changes occur when the SFP is inserted or removed. A low number of SFP state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 240
failures that the port experiences has fallen problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 241
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot that the port experiences has troubleshoot your host bus adaptor (HBA) and contact your switch service provider - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 242
you continue to experience loss-of-synchronization errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity WARNING FW-1167 Message , [FW-1167], ,, INFO, , , , is between high and low boundaries - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 243
of signal losses that the port experiences has changed. Loss of signal generally indicates a physical problem. Recommended Check both ends of that the switch is functioning normally. Severity INFO FW-1170 Message , [FW-1170], ,, WARNING, , , - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 244
number of protocol errors that the port experiences has fallen below the low boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. Recommended No - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 245
Cause Indicates that the number of protocol errors that the port experiences has risen above the high boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. Recommended Check both ends of your connection. Verify that your - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 246
number of invalid words that the port experiences has fallen below the low boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 247
policy of the Action end-user installation. A low number of invalid CRCs means that the switch is functioning normally. Severity INFO FW-1182 Message , [FW-1182], ,, WARNING, , , , is above high boundary(High=, Low= - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 248
High=, Low=). Current value is . Probable Cause Indicates that the percentage of incoming traffic that the port experiences has changed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 249
(High=, Low=). Current value is . Probable Cause Indicates that the percentage of incoming traffic that the port experiences has risen above the high boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 250
(High=, Low=). Current value is . Probable Cause Indicates that the percentage of outgoing traffic that the port experiences has fallen below the low boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 251
, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 252
E_Port, has become an F_Port, has segmented, or has become a trunk port. Recommended No action is required. Respond to this message as is appropriate to numbers of messages indicate a problem in this area. A low level of invalid CRC errors means that the switch is functioning normally. 200 Fabric - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 253
fluctuations, and aging equipment. You should set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 254
29 FW-1240 FW-1240 Message , [FW-1240], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) cyclic redundancy check (CRC) errors has - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 255
=, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 256
High value>, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 257
value>, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has fallen below the low boundary. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 258
>, Low=). Current value is . Probable Cause Indicates that the number of frame types or commands that the port receives has changed. The port has received small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 259
the number of frame types or commands that the port receives has changed from a value outside of the acceptable range to a value within (IP) addresses that are authorized to establish telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 260
an unauthorized IP address. The TELNET_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 261
unauthorized IP address. The HTTP_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish browser connections to the switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 262
network management protocol policy (SNMP_POLICY) contains a list of internet protocol (IP) addresses that are authorized to establish API connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 263
network management protocol policy (SNMP_POLICY) contains a list of internet protocol (IP) addresses that are authorized to establish API connections to switches in the fabric. Recommended No action is required. Action Severity INFO FW-1308 Message , [FW-1308], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 264
29 FW-1310 FW-1310 Message , [FW-1310], ,, WARNING, , , is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of simple network management protocol read (RSNMP) - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 265
29 FW-1313 FW-1313 Message , [FW-1313], ,, INFO, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of simple network management protocol write (WSNMP) - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 266
SES violations indicate that an small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world-wide name (WWN). The SES_POLICY contains a list of WWNs of device ports that are allowed to access the SES Server functionality. Recommended No action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 267
violations indicate that an small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world-wide name (WWN). The MS_POLICY contains a list of WWNs of device ports that are allowed to access the Management Server functionality. Recommended Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 268
number of serial violations has changed. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch world-wide names (WWNs) for which serial port access is enabled. Recommended Action Run the errShow command to determine the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 269
has fallen below the low boundary. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch world-wide names (WWNs) for which serial port access is enabled. Recommended No action is required. Action Severity INFO FW-1326 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 270
violations has changed. Front panel violations indicate that an unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch world-wide names (WWNs) for which front panel access is enabled. Recommended Action Run the errShow command to determine the WWN of - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 271
within the acceptable range. Front panel violations indicate that an unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch world-wide names (WWNs) for which front panel access is enabled. Recommended No action is required. Action Severity INFO FW-1332 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 272
performing FLOGI is done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 273
performing FLOGI is done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 274
device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports. DCC policies ensure that whenever a device performs a fabric login (FLOGI) request that the world-wide name (WWN - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 275
has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 276
from the primary world-wide name (WWN). When the primary fabric configuration server (FCS) downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 277
violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 278
-signature violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 279
violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 280
in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets received - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 281
the low boundary. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 282
the high boundary. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 283
>, is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of switch link authentication protocol (SLAP) faulty packets has risen above the high boundary. This counter keeps track of the number of unexpected SLAP packets - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 284
is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has fallen below the low boundary. Recommended No action is required. Action Severity INFO FW-1366 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 285
Current value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed from a value outside of the acceptable fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 286
finds that there are no FCSs in the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 287
to a value within the acceptable range. This violation indicates the number of secure switches with different version stamps have been detected. When a switch is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible security - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 288
tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 289
Indicates that the flash usage percentage has changed. Flash increases and decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 290
usage percentage has risen above the high boundary. Flash increases and decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended You might have to remove some unwanted files to create some flash space. Run the supportSave Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 291
Severity WARNING FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 292
29 FW-1428 FW-1428 Message , [FW-1428], ,, WARNING, , Switch status change contributing factor Power supply: absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of missing - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 293
same level of firmware to both CPs. Replace any faulty CPs. If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to clear the problem. Severity WARNING Fabric - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 294
, [FW-1436], ,, WARNING, , Switch status change contributing factor Marginal ports: marginal ports. (Port(s) ) Probable Cause Indicates that the switch status is not in a healthy state. This occurred - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 295
FW-1437 Message , [FW-1437], ,, WARNING, , Switch status change contributing factor faulty ports: . (Port(s) . Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 296
that the state of the specified field-replaceable unit (FRU) has changed to "inserted". This means that an FRU is inserted but not powered on. Recommended No action is required. Verify that the event was planned. Action Severity INFO FW-1442 Message , [FW-1442], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 297
default values when an AP blade is or has been present are: 2 out of service indicates switch status is DOWN, 1 out of service indicates switch status is MARGINAL Recommended Action To maintain full (2X) redundancy and proper monitoring by Fabric Watch, 4 active power supplies should be supplied - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 298
29 FW-1500 FW-1500 Message , [FW-1500], ,, WARNING, , Mail overflow - Alerts being discarded. Probable Cause Indicates that mail alert overflow condition has occurred. Recommended Resolve or disable the mail alert using the fwMailCfg command. Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 299
minor". The active CP will blade by ejecting the card and reseating it. If the problem switch errors. The switch processor reboots can be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands. Some examples of errors that might initiate this message are hardware errors, software - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 300
• Reboot:WebTool • Fastboot:WebTool • Software Fault:Software Watchdog • Software Fault:Kernel Panic • Software Fault:ASSERT • Reboot:SNMP • Fastboot: threshold. Probable Cause Indicates that either the Active CP EMAC controller or standby CP is down.The active CP will run diagnostic test on the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 301
30 HAM-1006 Recommended The standby CP will take over and reset the active CP.The system will be non-redundant as the Action standby becomes the active CP. Severity CRITICAL Fabric OS Message Reference 249 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 302
30 HAM-1006 250 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 303
command and contact your switch service provider. Severity CRITICAL HAMK-1002 Message , [HAMK-1002], ,, INFO, , Heartbeat down. Probable Cause Indicates that the active control processor (CP) blade determined that the standby CP blade is down. This can - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 304
31 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], ,, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. This message is typically seen when the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 305
32 HIL-1101 Message , [HIL-1101], ,, ERROR, , Slot faulted, () is above threshold. Probable Cause Indicates that the blade voltage is above the threshold. Recommended Replace the faulty blade or switch - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 306
, and 4024 the entire switch must be replaced, because these switches do not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100, 4900, 5000, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 307
, and 4024 the entire switch must be replaced, because these switches do not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100, 4900, 5000, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 308
not applicable to the Brocade 24000, or 48000. Recommended Action For the Brocade 3900 replace the fan field-replaceable unit (FRU). For the Brocade 3016, 3250 and 3850, the entire switch must be replaced, because these switches do not have FRUs. Severity ERROR 256 Fabric OS Message Reference - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 309
32 HIL- problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000, or 48000. Recommended For the Brocade range of your switch. Refer to the hardware reference manual for your switch for the operational temperature - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 310
32 HIL-1301 HIL-1301 Message , [HIL-1301], ,, WARNING, < been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity WARNING HIL-1302 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 311
32 HIL-1305 Severity ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fan(s) failed. Replace failed fan FRUs immediately. - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 312
32 HIL-1309 Recommended Replace the faulty fan field-replaceable units (FRUs) immediately. by a low fan speed message. Recommended Since the fans are not field replaceable, replace the switch if the temperature is high. Action Severity WARNING HIL-1311 Message , [HIL-1311], < - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 313
32 HIL-1402 Probable Cause Indicates that one fan field-replaceable unit (FRU) has , , Slot , high temperature (). Indicates that the temperature of this blade has risen above the warning threshold. Fabric OS Message Reference 261 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 314
and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the blade. Severity CRITICAL HIL-1503 Message , [HIL-1503], , FFDC - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 315
32 HIL-1505 Recommended No action is required. Action Severity INFO problems, make sure that all the fans are working properly. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 316
32 HIL-1508 HIL-1508 Message , [HIL-1508], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 317
> fans out of service. System is shutting down immediately. Probable Cause Indicates that total fan failure count is greater than or equal to two. Recommended In order to avoid causing damage to the switch, the system shuts down automatically. To help Action prevent future problems, make sure that - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 318
32 HIL-1650 Severity ERROR 266 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 319
HLO-1003], , FFDC, ERROR, , Invalid Hello received from port , Domain = , Remote Port =. Indicates that the HLO message received was invalid and the frame was dropped. The Brocade switch will not accept FSPF frames from the remote - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 320
an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 321
Action Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 269 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 322
34 HMON-1001 270 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 323
>, [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that information on PID, format refer to the Fabric OS Administrator's Action Guide. Severity INFO HTTP-1002 Message , [HTTP-1002], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 324
35 HTTP-1003 272 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 325
Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Power off and power on the blade using the slotPowerOff and slotPowerOn commands. On the Action Brocade 7500 or 7600, switch off and on all primary power in order to power-cycle the unit - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 326
36 IBD-1001 274 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 327
-name>, iSCSI login sessions exceed the maximum limit at slot port ge Probable Cause Indicates that the iSCSI login sessions exceed the supported limit per port. Recommended Use another port to login. Action Severity WARNING Fabric OS Message Reference 275 53-1000600 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 328
37 IBPD-1003 276 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 329
or power cycle the switch. Severity ERROR ICPD-1002 Message , [ICPD-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the ICPD failed. Recommended Download a new firmware - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 330
ICPD-1007 Message , [ICPD-1007], ,, INFO, , iSNSC service is on the switch. Probable Cause Indicates that the iSNSC service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO 278 Fabric OS Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 331
38 ICPD-1008 ICPD-1008 Message , [ICPD-1008], ,, INFO, , iSCSI switch () is . Probable Cause Indicates that the iSCSI switch is reachable or unreachable. Recommended No action is required. Action Severity INFO Fabric OS Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 332
38 ICPD-1008 280 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 333
and prefix> Probable Cause Indicates that a change in local IP address has occurred. If the source of the address change is manual, this means that the address change was initiated by a user. If the source of the address change is the dynamic host configuration protocol (DHCP - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 334
39 IPAD-1001 282 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 335
transfers; then run the supportSave command and contact your switch service provider. Severity WARNING IPS-1004 Message , [IPS-1004], ,, WARNING, , Port Config Mode Mismatch slot () port(ge): current mode is () Fabric OS Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 336
WARNING IPS-1005 Message , [IPS-1005], ,, WARNING, , Tunnel Authorization Failure for slot () port(ge) tunnel ID() reason () Probable Cause Indicates that tunnel setup failed due to authorization failure from the remote - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 337
[ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates that specified port has crashed. Recommended No action is required; the port will restart automatically. Action Severity ERROR Fabric OS Message Reference - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 338
41 ISCS-1000 286 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 339
name>, Start peering with external iSNS server slot/port /ge. Probable Cause Indicates that peering has started with the specified external internet storage name service (iSNS) server. Recommended No action is required. Action Severity INFO ISNS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 340
Start re-register with external iSNS server slot/port /ge. Probable Cause Indicates that the re-register with the specified external internet storage name service (iSNS) server has started. Recommended No action is required. Action Severity INFO - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 341
with a valid slot/port. Refer to the appropriate hardware reference manual for valid slot and Action port ranges. Severity WARNING ISNS-1011 Message Probable Cause Recommended Action , [ISNS-1011], ,, INFO, , iSNS Client Service is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 342
Start peering with external iSNS server on management port. Probable Cause Indicates that peering has started with the specified external internet storage name service (iSNS) on the management port. Recommended No action is required. Action Severity INFO 290 Fabric OS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 343
action is required. Action Severity INFO FCR-1003 Message , [FCR-1003], ,, INFO, ,FC router physical devices newly exported at port . Probable Cause Indicates that one or more physical devices have been newly exported through the specified - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 344
. Action Severity INFO FCR-1006 Message , [FCR-1006], ,, INFO, , FC router LSAN zone device added at port . Probable Cause Indicates that a device is added to a logical storage area network (LSAN) zone in the edge fabric. Recommended No - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 345
required. Action Severity INFO FCR-1010 Message , [FCR-1010], ,, INFO, , FC router LSAN zone disabled at port . Probable Cause Indicates that a logical storage area network (LSAN) zone is disabled in the edge fabric attached to the specified - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 346
build completed on port . Probable Cause the specified port. Recommended No completed on port . or VEX_Port added on port in domain < on the specified port in the specified domain fabric no longer reachable at port id fabric ID - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 347
. Use the fcrProxyDevShow command to view how many proxy devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove, zoneDelete, cfgDelete, and cfgDisable in the edge fabric. Proxy devices can be removed - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 348
FCR-1023 Message Probable Cause , [FCR-1023], ,, WARNING, , Local phantom port WWN entries exhausted. Indicates that the number of port world-wide names (WWNs) in use exceeds the local port WWN resources. 296 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 349
a translate domain (which limits the number of translate domain ports required) by limiting the devices specified in logical storage area network that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 350
Cause Indicates that the port world-wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected to not be in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 351
. Action Severity INFO FCR-1033 Message Probable Cause , [FCR-1033], ,, INFO, , Edge fabric disabled security on port in fabric . Indicates that Secure mode was turned off in the edge fabric. Fabric OS Message Reference 299 53 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 352
43 FCR-1034 Recommended No action is required. Action Severity INFO FCR-1034 Message , [FCR-1034], ,, INFO, , LSAN zone added in backbone fabric. Probable Cause Indicates that a new logical storage area network (LSAN) zone was added to the backbone - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 353
: . Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch's zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN) Action zones - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 354
was not set. Recommended Action Setting port credits failed. Execute the portEnable command. If the problem persists try rebooting the switch. If the message persists, collect switch information using the supportShow command, and contact your switch service provider. Severity ERROR 302 Fabric - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 355
link protocol (ELP) command was issued and it is not supported. Recommended Action Run the portEnable and portDisable commands to enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , [FCR-1053], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 356
edge routing is not needed. Otherwise replace the switch with Action one that supports backbone to edge routing. Severity INFO FCR- port configuration on both sides of the link using the portCfgShow command. Investigate the other switch for more details. Run the errShow command on the other switch - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 357
, etc. Run the portCfgExport command to modify the appropriate parameters on the local switch. Run the appropriate configuration command to modify the switch or port parameters on the remote switch. Severity WARNING FCR-1059 Message , [FCR-1059], ,, INFO, - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 358
Port disabled, system only supports EX/VEX_ports. Probable Cause Indicates that the maximum number of supported >. Probable Cause Indicates that the fabric ID of the switch does not match the local switch. Recommended Run the switchShow command to display the fabric - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 359
by entries; max entries: . Probable Cause Indicates that the total number of zone configurations created in the connected fabric exceeds the maximum number supported by the Fibre Channel. The limit includes both active and configured information that is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 360
with the fcrState set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity INFO number>,, INFO, , Port is changed from FCR port to non FCR port. Indicates that the port is no longer an EX_Port or - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 361
than characters in the edge fabric connected to port . Probable Cause Indicates that the zone name configuration size created in the connected fabric exceeds the maximum supported by the FC Router. This size is equal to the total number of characters used by all the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 362
Port rejected fabric binding request/check from the M-Model switch; . Probable Cause Indicates that an M-Model edge switch attempted to either activate or check the fabric binding. This port LSAN name exceeds the limit of 64 characters. Recommended Please change the name - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 363
found, run supportFtp to send all core files to a secure server location. Copy the warning message along with any core file information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 311 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 364
44 KSWD-1003 312 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 365
>, Dump memory size exceeds dump file size Probable Cause Indicates that the dump memory size has exceeded the dump file size. Recommended No Cannot open ATA dump device Probable Cause Indicates that the ATA dump driver is not initialized properly. Recommended No action is required. Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 366
45 KTRC-1005 Recommended No action is required. Action Severity ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that Trace was unable to - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 367
or the haFailover command on bladed switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING LOG-1002 Message , [LOG-1002], , FFDC - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 368
46 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates that the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 316 Fabric OS Message Reference 53- - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 369
valid link state ID is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR LSDB-1002 Message , [LSDB-1002], ,, INFO, - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 370
domain Probable Cause Indicates that there is no link state record for the specified local domain. Recommended No action is required. The other switch will pass the LSD when the fabric has become stable. Action Severity WARNING 318 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 371
Chapter MFIC System Messages 48 MFIC-1001 Message , [MFIC-1001], ,, ERROR, to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MFIC-1002 Message , [MFIC-1002], ,, - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 372
48 MFIC-1003 MFIC-1003 Message , [MFIC-1003], ,, WARNING, , Effective Insistent domain ID for the fabric changed from to Probable Cause Indicates that one or more switches joined the fabric with a different insistent domain ID (IDID) mode - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 373
Chapter MPTH System Messages 49 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Cause Indicates that a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 374
49 MPTH-1003 322 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 375
• 7 - MSG_LINIT_IU • 8 - MSG_RSCN • 9 - MSG_IOCTL • 10 - MSG_ACCEPT • 11 - MSG_IU_FREE • 12 - MSG_US • 13 - MSG_EXT_RSCN • 14 - MSG_RDTS_START • 15 - MSG_RDTS_SENDEFP • 16 - MSG_RDTS_RESET Recommended No action is required. Action Severity ERROR Fabric OS Message Reference 323 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 376
50 MQ-1004 324 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 377
. Recommended Action: Set the flag for the MS Platform Service. • The GCAP (MS Get Capabilities) is not supported by another switch. Recommended Action: Upgrade the firmware level on the switch to a level that supports RCS. • The request to the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 378
by> Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater transfers; then run the supportSave command and contact your switch service provider. Severity INFO MS-1004 Message , [MS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 379
received information unit (IU) data of unexpected size. The IU payload and the IU size might be inconsistent with each other or with the up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MS-1008 Message , [MS-1008], < - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 380
>, RLIR event. Switch Port ID is . Device Port Tag is . . likely due to SAN hardware problems such as bad switch service provider. Severity ERROR MS-1022 Message , [MS-1022], ,, INFO, , Management Server Platform Service - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 381
, [MS-1023], ,, INFO, , Management Server Topology Discovery Service Probable Cause Indicates that Management Server Topology Discovery Service is being enabled or disabled. Recommended No action is required. Action Severity INFO MS - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 382
51 MS-1024 330 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 383
this error occurs repeatedly, it means the protocol implementation between two connected switches has problems. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then this message can safely be ignored. Otherwise, run the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 384
on the specified port. Neighbor finite state machine (NBFSM) states are as follows: • 0 - Down • 1 - Init • 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full Recommended No action is required. The Fabric OS auto recovers from this problem. Action Severity WARNING - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 385
> is larger than the max frame size the remote switch can support! Probable Cause Indicates that the response payload exceeds the maximum frame size that the remote switch can handle. Recommended Action Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, as - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 386
of the lowest version of firmware. Severity INFO NS-1005 Message , [NS-1005], ,, WARNING, , Zone size of has over the supporting limit of for the remote switch domain ID . Probable Cause - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 387
. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 335 53 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 388
PDM) process ran out of memory. Recommended Action Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 389
. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 337 53 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 390
. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1012 Message , [PDM - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 391
firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service PDM-1021], ,, WARNING, , Failed to download area port map. Fabric OS Message Reference 339 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 392
is not supported by older firmware. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 393
54 PDM-1024 Fabric OS Message Reference 341 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 394
54 PDM-1024 342 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 395
Chapter PDTR System Messages 55 PDTR-1001 Message , [PDTR-1001], ,, INFO, , < informational message > Probable Cause Indicates that information has been written to the panic dump files. The watchdog register codes are as follows: • 0x10000000 bit set - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 396
55 PDTR-1002 344 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 397
run the supportSave command and contact your switch service provider. Severity CRITICAL PLAT-1001 Message < a CP that is in the process of becoming the active CP. Note that in certain circumstances a CP may experience problem. If Action the problem still persists, then replace the CP. Fabric - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 398
56 PLAT-1002 Severity CRITICAL 346 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 399
> Faulted because of many Link Failures Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple failures that exceed an internally set threshold on the port. This problem is typically related to hardware. Recommended Action Check and replace (if - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 400
portCfgLport to clear configuration. Probable Cause Indicates that the specified port is configured to be an L_port, but that port does not support L_port. If an L_port is connected, then the port will be disabled because it does not support L_port. If an E_port or F_port is connected then the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 401
software error has occurred in Advanced Performance Monitoring. The Performance Monitor has failed to initialize. Recommended The CP should reboot (or fail over) automatically. If it does not, reboot or power cycle the switch to Action reinitiate the firmware Administrator's Guide for more activating - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 402
the restoring configuration has attempted to set the end-to-end monitoring mask on at least one ISL port. Recommended No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is Action enabled. ISL monitoring can only be disabled through the Fabric Access API - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 403
INFO PSWP-1003 Message , [PSWP-1003], ,, INFO, , Port Swap feature disabled. Probable Cause Indicates that the portSwap feature has been disabled in the switch. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 351 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 404
59 PSWP-1003 352 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 405
that the maximum storage size for FFDC data capture is reached. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1004 Message , [RAS-1004], , FFDC, WARNING, , Software 'verify' error detected - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 406
60 RAS-1006 Probable Cause Indicates an internal software error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support data file () - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 407
60 RAS-3001 Probable Cause A user has changed the configured classes of the audit feature. Recommended No action is required. Action Severity INFO RAS-3001 Message , [RAS-3001], , INFO, , USB storage device plug-in detected. Probable Cause Indicates that - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 408
60 RAS-3004 Recommended No action is required. Action Severity INFO 356 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 409
and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message , [RCS . Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. Severity ERROR Fabric OS Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 410
in Fabric OS v2.6, v3.1 and greater, v4.1 and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message , [RCS-1005], ,, INFO, , Phase , - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 411
remote domain rejected an RCS phase initiated by an application on the local switch. If the reject phase is ACA, the remote domain might be busy and size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 412
61 RCS-1008 360 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 413
-name>, Permission denied accessing certificate file. Secure RPCd is disabled. Probable Cause Indicates that the SSL certificate file configured on the switch could not be accessed because root did not have read-level access. Recommended Change the file system access level for the certificate - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 414
, , Permission denied accessing private key file. Secure RPCd is disabled. Probable Cause Indicates that the private key file configured on the switch could not be accessed because root did not have read-level access. Recommended Change the file system access level for the private key - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 415
Possible detail values include: • RTWRTransmit: Max retries exhausted • detail1: Port • detail2: Domain • detail3: Retry Count • detail4: Status fabricShow command to see if the specified domain ID is online. Enable the switch with the specified domain ID. If the message persists, run supportFtp (as - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 416
ID is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO 364 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 417
Chapter SAS System Messages 64 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 418
64 SAS-1001 366 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 419
for the specified daemon name is full. This might be caused by software watchdog will cause the daemon to dump the core and reboot the switch . If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 420
65 SCN-1001 368 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 421
. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1002 Message , [SEC-1002], ,, ERROR, , Security data fails: - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 422
switch encountered an error accepting the database download. The primary switch will segment the failed switch after 30 tries. Recommended Action Reset the version stamp on the switch then run the supportSave command and contact your switch service provider. Severity WARNING SEC-1005 Message < - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 423
was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the HTTP connection. Action Severity INFO SEC-1009 Message , [SEC-1009], ,, INFO, , Security violation - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 424
key infrastructure (PKI) objects exist on the switch. If the private key does not exist, , outlined in the Secure Fabric OS Administrator's Guide. If a certificate does not exist or is Indicates that the size of the security database is too large for the flash memory. The size of the security - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 425
fabric configurations server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the fabric configurations server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 426
configurations server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in that the security database size is not supported by the standby control processor (CP). Recommended Reduce the security policy size by deleting entries within - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 427
command. Only the secPolicyCreate command supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the switch connection control (SCC) policy. Refer - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 428
world-wide name (WWN) entered in the policy member list had an invalid format. Recommended Run the command again using the standard WWN format, 16 hexadecimal digits grouped as eight Action colon separated pairs. For example: 50:06:04:81:D6:F3:45:42. Severity ERROR SEC-1038 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 429
Severity ERROR SEC-1041 Message , [SEC-1041], ,, ERROR, , Invalid port member in portlist (). . Probable Cause Indicates that the port member is invalid for one of the following reasons: • The value is not a number. • The - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 430
SEC-1045], ,, ERROR, , Too many port members. Probable Cause Indicates that there has been a corruption during the configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 431
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 432
list . Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 433
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 434
configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in either that no domains or domains more than the maximum number supported are specified. Recommended Enter the correct number of domains. Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 435
. Probable Cause Indicates that the public key infrastructure (PKI) objects on the switch are not in a valid state and the signature operation failed. Recommended Run the command Action and contact your switch service provider. Severity ERROR Fabric OS Message Reference 383 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 436
no changes in the defined security policy database need to be activated at this time. Recommended Verify that the security event was planned FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1073 Message , [SEC-1073], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 437
not allowed in non-secure mode is attempted, do not perform the operation in non-secure mode. In secure mode, run the command from a switch that has required privilege, that is, either a backup FCS or primary FCS. Severity ERROR SEC-1075 Message , [SEC-1075], ,, ERROR - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 438
. Probable Cause Indicates that the policy could not be activated. Possible reasons that the policy could not be activate include not enough memory or a busy switch. Recommended Run the secFabricShow command to verify that all switches in the fabric are in the ready state. Action Retry the command - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 439
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 440
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 441
the security database has more data than can be distributed to some of the switches in the fabric. Recommended Reduce the number of entries in the security policies to decrease the security database size. Action Severity ERROR SEC-1088 Message , [SEC-1088], ,, ERROR - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 442
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 443
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 444
timestamp>, [SEC-1097], ,, ERROR, , Cannot find policy set. Probable Cause Indicates that the specified policy could not supportSave command and contact your switch service provider. Severity ERROR 392 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 445
, , No FCS list. Probable Cause Indicates that the specified policy could not be found. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 446
more switches in switches in the fabric are in the ready state. When all switches download . Probable Cause Indicates that the switch failed to download certificate, security database, or policies. This can happen when switch Indicates that the switch failed to primary switch has - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 447
for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. Severity ERROR SEC-1107 Message , [SEC-1107], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 448
the secFabricShow command to verify that all switches in the fabric are in the ready state. When all switches are in the ready state, retry in common with current active FCS list. Fail to download defined database. Probable Cause Indicates that the defined and active fabric configurations server ( - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 449
-name>, FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch. Probable Cause Indicates that either a security policy download is attempted with an active policy that does not have the fabric configurations server (FCS) policy - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 450
all switches are in the ready state, retry the operation. Severity INFO SEC-1118 Message , [SEC-1118], ,, INFO, , Fail to set SNMP string. Probable Cause Indicates that the SNMP string could not be set. Recommended Usually this problem is transient - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 451
Probable Cause Indicates that the time on the switch is not synchronized with the primary fabric configurations switches are in the ready state, retry the operation. Severity INFO SEC-1123 Message , [SEC-1123], ,, INFO, , Security database downloaded - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 452
INFO SEC-1130 Message , [SEC-1130], ,, INFO, , The Primary FCS has failed over to a new switch. Probable Cause Indicates that an FCS failover operation was completed successfully. Recommended Action Verify that the security event was planned. If the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 453
switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service fabric configurations server (FCS) switch received a security database download. Recommended Action Verify that the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 454
from the primary fabric configurations server (FCS) switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or the signature verification failed. Signature verification - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 455
support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 456
can be either defined, active, or both. A negative value means that a policy set was failed by the daemon. Recommended Reduce the size of the specified policy database supportSave command and contact your switch service provider. Severity INFO 404 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 457
updated for that specific switch. Severity INFO SEC-1160 Message , [SEC-1160], ,, INFO, , Duplicate port in port list (). Probable Cause Indicates that a duplicate port member exists in the specified port list. Recommended Verify - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 458
Severity ERROR SEC-1165 Message , [SEC-1165], ,, ERROR, , Low memory, failed to enable security on all switches. Probable Cause Indicates that the system is low on memory. Recommended Wait a few minutes and try the command again. Action Severity ERROR - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 459
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 460
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 461
to set password. Probable Cause Indicates that the FCS or non-FCS password could not be set. Recommended Verify that all switches in the fabric are in time synchronization with the primary and that no Action external entity is trying to access the fabric. When verification is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 462
sequence-number>,, ERROR, , Policy to binary conversion error: Port is out range. Probable Cause Indicates that a security database run the supportSave command and contact your switch service provider. Severity ERROR 410 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 463
DB. Probable Cause Indicates that the switch database was enabled or disabled as the secondary authentication, accounting, and authorization (AAA) mechanism when the Remote Authentication Dial-in User Service (RADIUS) / Lightweight Directory Access Protocol (LDAP) is the primary AAA mechanism - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 464
,, INFO, , Security violation: Unauthorized device tries to FLOGI to index/area of switch . Probable Cause Indicates that a device connection control (DCC) security violation was reported. The specified device attempted to - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 465
66 SEC-1190 SEC-1190 Message , [SEC-1190], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP read operation. Probable Cause Indicates that an SNMP security violation was reported. The specified unauthorized - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 466
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 467
all default account names. Probable Cause Indicates that the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Reset the default admin and user account names on the switch that reported the warning and retry Action enabling security. Severity - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 468
-1199 SEC-1199 Message , [SEC-1199], ,, INFO, , Security violation: Unauthorized access to serial port of switch . Probable Cause Indicates that a serial connection policy security violation was reported. An attempt was made to access the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 469
access from MS device node name , device port name . Probable Cause Indicates that a management server (MS) security run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 417 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 470
run the supportSave command and contact your switch service provider. Severity ERROR SEC-1300 Message , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Probable Cause Indicates that the switch is set up with VC-encoded - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 471
the currently installed software version does not support the Brocade Secure Fabric OS feature. Recommended Run the firmwareDownload command to update the firmware to the latest version for your specific Action switch. Verify that the firmware you are installing supports the Brocade Secure Fabric - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 472
to validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. If PKI objects are valid, verify that an unauthorized switch is not trying to access the fabric. Severity INFO 420 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 473
/LDAP server identity>. Probable Cause Indicates that after some servers timed out, the specified remote authentication dial-in user service (RADIUS/LDAP) server responded to a switch request. Recommended If the message appears frequently, move the responding server to the top of the RADIUS/LDAP - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 474
of the password policies is not set to default value. Probable Cause Indicates that the security enable failed on the fabric because one or more switches in the fabric have password policies that are not set to the default value. Recommended Action Verify that the security event was planned. If - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 475
EM module to retrieve the IP address failed. Recommended Please reboot the system to fix this error. If the problem persists contact your switch service Action provider. Severity ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, , command - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 476
, , Non-acl domain tries to join a fabric with strict fabric wide policy Probable Cause Indicates that a domain not supporting an access control list (ACL) policy tried to join a fabric with a strict fabric-wide policy. Recommended No action is required. The domain is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 477
Indicates that the security enable failed on the fabric because switch has conflicting configuration such as fabric wide consistency configuration or to support a device connection control (DCC) policy with more than 256 ports. Recommended Reconfigure any policy that includes more than 256 ports in - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 478
error: Probable Cause Indicates that the reliable commit service (RCS) transaction failed with specified reason code. Recommended Verify that number>,, ERROR, , Security enforcement: Switch connecting to port is not authorized to stay in fabric - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 479
Recommended Action None, the domain is denied by disallowing all its E-ports connected to the fabric. If the domain should be allowed to FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1330 Message Probable Cause , - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 480
. Probable Cause Indicates that the secModeEnable command failed on the fabric, because default IP Filter policies are not active on the switch, or an active transaction exists on IP Filter policies. Recommended Action Verify that the security event was planned. If the security event was - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 481
Cause Indicates that the initialization of the simple network management protocol (SNMP) service failed and you will not be able to query the switch through SNMP. Recommended Reboot or power cycle the switch. This will automatically initialize SNMP. Action Severity ERROR SNMP-1003 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 482
Incorrect SNMP configuration. Probable Cause Indicates that the simple network management protocol (SNMP) configuration is incorrect and the SNMP service will not work correctly. Recommended Change the SNMP configuration back to the default. Action Severity ERROR SNMP-1005 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 483
Probable Cause Indicates that the supportSave command was used to transfer support information to a remote location. Recommended No action is required. command to set the FTP or SCP parameters. Action After the problem is corrected, rerun the supportSave command. Severity WARNING SS-1002 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 484
due to possible errors in subcommands being executed by the supportSave command. Recommended Run usbstorage to check the USB storage device settings. After the USB problem is corrected, Action rerun the supportSave command. Severity WARNING 432 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 485
continue without disruption. Do not fail over or power down the system during firmware upgrade. No action is required. Run the firmwareDownloadStatus Indicates that the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 486
sequence-number>,, INFO, , Forced failover succeeded. New Active CP is running new firmware. Probable Cause Indicates that the previous standby has now become the active CP and is running the new firmware version. Recommended Action No action is required. The firmwareDownload command - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 487
failed because FABRIC OS is disabled on Active CP." "Sanity check failed because HAMD is disabled on Active CP." "Sanity check failed because failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 488
CP." "firmwareCommit has completed successfully on Standby CP." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareCommit has started on both Active and Standby CPs." "firmwareCommit has completed successfully on both CPs." "firmwareCommit failed on - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 489
be started to recover the 0xa2 blade." "Blade rebooted during firmwareCommit. The operation will be restarted." 0xa3 "Firmware has been downloaded successfully. Blade is rebooting with the new firmware." 0xa4 "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 490
. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 491
Cannot download 5.1 because Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding." 0x2d "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 492
may be caused by an unsupported blade type in the chassis. Remove or power off the unsupported blades before proceeding. Another possible cause may networking issues. Please reload firmware packages on the file server, then retry firmwareDownload. If the problem persists, contact your system - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 493
director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of firmware active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting your switch service provider. - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 494
trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message Probable Cause , [SULB-1021],, AUDIT, WARNING, , Firmware is being downloaded to the blade in slot . Indicates - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 495
version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 496
slot will reboot with the new firmware. Probable Cause Indicates that new firmware has been downloaded to the specified AP blade and that the AP blade will reboot to active it. Recommended Wait for the blade to reboot. Action Severity WARNING SULB-1026 Message , [SULB - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 497
by inconsistent internal firmware image. It may also be caused by the internal Ethernet or persistent storage hardware failure. Recommended Reset the switch. This will cause the internal image to be relocated again. If the problem persists, Action contact your switch service provider. Severity - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 498
generally logged before download and after download of the firmware to store version information. Recommended No action is required. Action Severity INFO SULB-1037 Message , [SULB-1037], , AUDIT, INFO, , HCL failed. Reboot the switch manually using the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 499
as inconsistent during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR Fabric OS Message Reference 447 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 500
or AP7600 switch, reboot or power cycle the switch. Severity ERROR SWCH-1006 Message , [SWCH-1006], ,, WARNING, , HA state out of sync: Standby CP (ver = ) does not support NPIV functionality. (active ver = , NPIV - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 501
that already has area swapped. Recommended Action Replace the blade with ports that support port swap. Then port swap the ports back to ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. Severity WARNING Fabric OS Message Reference 449 53 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 502
70 SWCH-1008 450 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 503
more programs to register with system services or to fail over to active status. Recommended Action The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before rebooting the chassis, record the firmware version on the switch or control processor (CP) and run - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 504
supported by CP Blade with ID - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 505
Action Run the memShow command to view the switch memory usage. Reboot or power cycle the switch. Run supportFtp as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message , [SYSM - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 506
is properly seated in its slot. Action Severity CRITICAL SYSM-1006 Message , [SYSM-1006], , FFDC, CRITICAL, , CP blade in slot is incompatible with the chassis type. Probable Cause Indicates that this chassis type is not compatible with the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 507
WATCHDOG EXPIRED generated by hardware watchdog expiration • MANUAL generated by the tracedump -n command Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity WARNING TRCE-1002 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 508
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR TRCE-1004 Message , [TRCE-1004], ,, WARNING, , Trace dump< optional slot indicating on - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 509
that the active CP is unable to alert the standby CP of a change in trace status. This message is only applicable to the Brocade 24000, and automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1008 Message , [TRCE-1008 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 510
command to verify that the current CP is standby and the active CP is active. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1010 Message , [TRCE-1010 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 511
system and the indicated slot is unavailable. Recommended Check that the AP blade is enabled and retry the command. If the AP blade is already enabled, run Action the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 459 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 512
73 TRCE-1012 460 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 513
message indicates a typing error by an authorized user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of a failed login is reported to the error log. Severity INFO TRCK-1003 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 514
, , Config file change from task: Probable Cause Indicates that the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload. This message is not - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 515
has the clock server IP configured correctly. Verify that this clock server is accessible to the switch and functional. If the principal or primary FCS does not support the feature, either choose a different switch for the role or reset the clock server to LOCL. Severity INFO Fabric OS Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 516
The message might be one of the following: • Init failed. Time Service exiting Probable Cause: Initialization error, Time Server exits. • Synchronizing time or role change of the principal or primary fabric configuration server (FCS) switch. If the message does not recur, it should be ignored. • - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 517
Cause Indicates that there is a change in the source of fabric time synchronization distributed from the principal or primary fabric configuration server (FCS) switch. Another clock server in the list of clock servers configured is being used. This happens when the network time protocol (NTP) query - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 518
75 TS-1008 466 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 519
Message , [UCST-1007], , FFDC, CRITICAL, , Inconsistent route detected: Port = , should be Probable Cause Indicates that the switch detected an inconsistency in the routing database between the routing protocol and the hardware - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 520
76 UCST-1020 468 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 521
, [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates that the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list (domain ID list). Recommended No action is required - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 522
77 UPTH-1001 470 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 523
Chapter WEBD System Messages 78 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured to be enabled but could not be started. Probable Cause Indicates that the SSL certificate file is either invalid or - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 524
will be restarted for logfile truncation Probable Cause Indicates that the size of HTTP logfile exceeded the maximum limit. Recommended No action of IP Address Probable Cause Indicates that the IP address of the switch changed and the HTTP server is restarted. Recommended No action is required - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 525
HTTP server cannot be started Probable Cause Indicates a rare error condition, where the built-in recovery process has failed to restore http services. The problem often results from invalid configuration of ssl certs., but there can be more than one reason for such failure. Recommended Run the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 526
78 WEBD-1008 474 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 527
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command to save these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 475 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 528
79 ZOLB-1001 476 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 529
zone groups during port login (PLOGI) trap processing. This messages usually indicates problems when adding content- switch service provider. Severity WARNING ZONE-1003 Message , [ZONE-1003], ,, WARNING, , zone() contains (, - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 530
-wide name (WWN) in one zone and in another, this will cause that port to go session based hard zoning. In session-based zoning, the zone enforcement is checked by the software. In hardware-enforced zoning, zone or alias members are defined using exclusively or - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 531
. Recommended Action There are two ways to avoid this problem. • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single port group on the switch. Severity INFO ZONE-1008 Message , [ZONE-1008], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 532
number>,, WARNING, , WARNING All ports are offline. Probable Cause Indicates that all the ports in a zone are offline. Recommended Check If the QuickLoop zoning configuration is enabled on the switch, it will not be supported. Recommended Edit the zone database to remove the QuickLoop - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 533
Probable Cause Indicates that the required zoning license is missing. Recommended Install the zoning license using the licenseAdd command. Refer to your switch supplier to obtain a Action Zoning license if you do not have one. Severity ERROR ZONE-1015 Message , [ZONE-1015], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 534
port. This is a software error. A QuickLoop zone type (value = 4) or an uninitialized type (value = 0) are invalid. The valid zone type values are: • hard port zone (value = 1) • hard wwn zone (value = 2) • session based hard zoning (value = 3) • FA zone (value = 5) QuickLoop zones are not supported - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 535
operation. This usually occurs if the switch on the other side of the port is busy. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE-1024 Message - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 536
edit the zoning database to have zoned PIDs for that Action port. Severity INFO ZONE-1027 Message , [ZONE-1027], < User Command: A user aborted the current zoning transaction. • Switch Shutting Down: The switch is currently shutting down. Recommended Action Many of the causes - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 537
switches in your fabric. Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING ZONE-1030 Message , [ZONE-1030 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 538
switch, port) members not supported. The switch is set to interop mode using the interopMode command. Interop mode does not allow members in the active -name>, Domain Max Zone DB size . Probable Cause Indicates that the specified domain does not - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 539
is not found. Recommended Use the firmwareDownload command to reinstall the firmware. Action Severity WARNING ZONE-1035 Message , [ZONE-1035], is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 540
OS cannot examine the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR ZONE-1038 Message , [ZONE-1038], - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 541
configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity or faulty cable. Recommended Check the SFP and cable at the specified port and verify that they are not faulty. Replace the SFP Action and - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 542
80 ZONE-1044 ZONE-1044 Message , [ZONE-1044], ,, INFO, , The Default Zone access mode is set to All Access. Probable Cause Indicates that the Default Zone access mode is set to All Access. Recommended Verify that this Default Zone access mode change was - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 543
Chapter AUDIT AUTH System Messages 81 AUTH-3001 Message AUDIT, , [AUTH-3001], INFO, SECURITY, , , , Event: , Status: success, Info: type has been changed from [] to []. Probable Cause Indicates - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 544
that an invalid entity attempted to connect to the switch. Recommended Action Check the connection port for a possible security attack. Check the shared ; then run the supportSave command and contact your switch service provider. Severity INFO 492 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 545
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-3008 Message AUDIT, , [AUTH- location>, , Event: , Status: failed, Info: Port has been disabled due to authentication failure with code '< - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 546
81 AUTH-3008 494 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 547
[CONF-1022], WARNING, CFG, , , , Downloading configuration without disabling the switch was unsuccessful. Probable Cause The system attempted to download a configuration without disabling the switch was unsuccessful because there are one or more parameters - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 548
82 CONF-1022 496 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 549
Chapter AUDIT HTTP System Messages 83 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 550
83 HTTP-1003 498 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 551
Event Name can be one of the following: - There has been an fabric configurations server (FCS) failover. - A security policy has been activated. - A security policy has been saved. - A security policy has been aborted. - A non-FCS password has changed. Recommended Action Verify that the security - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 552
84 SEC-3003 SEC-3003 Message AUDIT, , [SEC-3003], INFO, SECURITY, , , , Event: , Status: success, Info: Created policy, with member(s) . Probable Cause Indicates that a new security policy was created - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 553
84 SEC-3006 SEC-3006 Message AUDIT, , [SEC-3006], INFO, SECURITY, , , , Event: , Status: success, Info: Removed member(s) from policy . Probable Cause Indicates that a user has removed the specific - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 554
84 SEC-3009 SEC-3009 Message AUDIT, , [SEC-3009], INFO, SECURITY, , , , Event: , Status: success, Info: Security Transaction aborted. Probable Cause Indicates that the pending security transaction was aborted. Recommended Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 555
Name>, Status: success, Info: RADIUS server for AAA services. Probable Cause Indicates that a user has changed the remote authentication dial-in user service (RADIUS) configuration. Recommended Action Verify that the RADIUS configuration was changed intentionally. If - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 556
name> to position . Probable Cause Indicates that a user has changed the position of the remote authentication dial-in user service (RADIUS) server. Recommended Action Verify that the RADIUS server position was intentionally changed. If the RADIUS server position was intentionally - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 557
84 SEC-3018 SEC-3018 Message AUDIT, , [SEC-3018], INFO, SECURITY, , , , Event: , Status: success, Info: Parameter [] changed from [] to []. Probable Cause Indicates that the specified passwdCfg - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 558
password attempts exceeded, the account has been locked. Recommended The Account may automatically unlock after the lockout duration has expired or an administrator Action may manually unlock the account. Severity INFO 506 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 559
84 SEC-3024 SEC-3024 Message AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: , Status: success, Info: User account [], password changed. Probable Cause Indicates that the user's password changed. Recommended Action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 560
84 SEC-3027 SEC-3027 Message AUDIT, , [SEC-3027], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] []. Probable Cause Indicates that user account properties were changed. - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 561
SEC-3032 Message AUDIT, , [SEC-3032], INFO, SECURITY, , , , Event: , Status: success, Info: Switch is configured to database. Probable Cause Indicates that the specified event has occurred to accept - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 562
84 SEC-3033 SEC-3033 Message AUDIT, , [SEC-3033], INFO, SECURITY, , , , Event: fddcfg --fabwideset, Status: success, Info: Fabric wide configuration set to . Probable Cause Indicates that the specified - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 563
Filter Policy> ipfilter policy activated. Probable Cause Indicates that the specified IP filter policy has been activated. Recommended Action Verify that the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Take Action appropriate action - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 564
84 SEC-3044 SEC-3044 Message AUDIT, , [SEC-3044], INFO, SECURITY, , , FIPS mode has been changed to . Probable Cause Indicates that there was a change in the FIPS mode. Recommended Action Verify that the security event was planned. - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 565
84 SEC-3048 Severity INFO SEC-3048 Message AUDIT, , [SEC-3048], INFO, SECURITY, , , FIPS mode has been enabled in the system using force option. Probable Cause Indicates that the system has been forced to FIPS mode. Recommended Action Verify - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 566
84 SEC-3049 514 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 567
, Incorrect SNMP configuration. Probable Cause Indicates that the simple network management protocol (SNMP) configuration s incorrect and the SNMP service will not work correctly. Recommended Reset the SNMP configuration to default. Action Severity ERROR SNMP-1005 Message Probable Cause AUDIT - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 568
85 SNMP-1006 516 Fabric OS Message Reference 53-1000600-01 - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 569
continue without disruption. Do not fail over or power down the system during firmware upgrade. Run the firmwareDownloadStatus command for more information. Indicates that the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 570
failed because FABRIC OS is disabled on Active CP." "Sanity check failed because HAMD is disabled on Active CP." "Sanity check failed because failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 571
CP." "firmwareCommit has completed successfully on Standby CP." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareCommit has started on both Active and Standby CPs." "firmwareCommit has completed successfully on both CPs." "firmwareCommit failed on - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 572
be started to recover the 0xa2 blade." "Blade rebooted during firmwareCommit. The operation will be restarted." 0xa3 "Firmware has been downloaded successfully. Blade is rebooting with the new firmware." 0xa4 "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 573
. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 574
Cannot download 5.1 because Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding." 0x2d "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 575
may be caused by an unsupported blade type in the chassis. Remove or power off the unsupported blades before proceeding. Another possible cause networking issues. Please reload firmware packages on the file server, then retry firmwareDownload. If the problem persists, contact your system - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 576
on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 Message AUDIT, , [SULB-1010], INFO - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 577
another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message AUDIT, , [SULB-1021], WARNING, FIRMWARE, , , , Firmware is being downloaded to the blade in slot . Probable - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 578
version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message AUDIT - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 579
rebooted. Run the firmwareDownloadStatus Action command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message AUDIT, , [SULB-1032], WARNING, FIRMWARE, , , , Relocating an internal - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 580
to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, , , , HCL failed. Reboot the switch manually using the reboot command. However - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 581
Chapter AUDIT ZONE System Messages 87 ZONE-3001 Message AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \" - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 582
87 ZONE-3003 ZONE-3003 Message AUDIT, , [ZONE-3003], INFO, ZONE, , , , Event: , Status: success, Info: \"\" deleted. Probable Cause Indicates that the specified zone object has been deleted. The - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 583
87 ZONE-3006 ZONE-3006 Message AUDIT, , [ZONE-3006], INFO, ZONE, , , , Event: , Status: success, Info: Current zone configuration disabled. . Probable Cause Indicates that the current zone configuration has been disabled. - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 584
87 ZONE-3009 ZONE-3009 Message AUDIT, , [ZONE-3009], INFO, ZONE, , , , Event: , Status: success, Info: . Probable Cause Indicates that the specified zone transaction has been aborted. Recommended Verify that the - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 585
, , , Event: , Status: success, Info: has been activated. Probable Cause Indicates that the specified admin domain (AD) has been activated. Recommended Verify that the event was planned. If the event was planned, no action is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 586
87 ZONE-3015 ZONE-3015 Message AUDIT, , [ZONE-3015], INFO, FABRIC, , , , Event: , Status: success, Info: AD configurations applied. Probable Cause Indicates that the current admin domain (AD) configuration has been saved to flash is - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 587
87 ZONE-3018 ZONE-3018 Message AUDIT, , [ZONE-3018], INFO, FABRIC, , , , Event: , Status: success, Info: has been deactivated. Probable Cause Indicates that the specified admin domain (AD) object has been - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 588
87 ZONE-3021 ZONE-3021 Message AUDIT, , [ZONE-3021], INFO, FABRIC, , , , Event: , Status: success, Info: AD object \"\" renamed to \"\". Probable Cause Indicates that the specified admin domain ( - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 589
87 ZONE-3024 ZONE-3024 Message AUDIT, , [ZONE-3024], INFO, FABRIC, , , , Command: , Status: success, Info: executed. . Probable Cause Indicates that the admin domain ad --transabort operation was successful in the specified - HP StorageWorks 4/8 | Brocade Error Message Reference Guide v6.0.0 (53-1000600-0 - Page 590
87 ZONE-3025 538 Fabric OS Message Reference 53-1000600-01
53-1000600-01
19 October 2007
Fabric OS
Message Reference
Supporting Fabric OS v6.0.0