HP StorageWorks 4/8 HP StorageWorks DC and DC04 SAN Backbone Director Switches
HP StorageWorks 4/8 - SAN Switch Manual
View all HP StorageWorks 4/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/8 manual content summary:
- HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 1
HP StorageWorks DC and DC04 SAN Backbone Director Switches hardware reference guide Part number: 5697-7814 Second edition: February 2009 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 2
2008-2009 Hewlett-Packard Development Company, L.P. © Copyright 2008 Brocade Communications Systems, Incorporated The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 3
support ...17 Customer self repair ...17 Subscription service ...17 HP websites ...18 Documentation feedback ...18 1 HP StorageWorks DC SAN Backbone Director Switch Overview 19 HP StorageWorks DC SAN Director Power Pack 19 Features ...19 Hardware components ...20 Port side of the DC SAN Director - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 4
Establishing a serial connection and log on to the DC SAN Director 49 Configuring IP addresses ...51 Default IP addresses and password 51 Establishing an Ethernet connection 52 Customizing a switch name ...53 Setting the domain ID ...53 Verifying the Port Identifier mode and connecting to the - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 5
a serial connection and logging on to the DC04 SAN Director 145 Configuring IP addresses ...147 Default IP addresses and password 147 Establishing an Ethernet connection 148 Customizing a switch name ...149 Setting the domain ID ...149 Setting the date and time ...150 Setting the date ...150 HP - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 6
up the configuration ...152 9 Monitoring DC04 SAN Director system components 153 Introduction ...153 Monitoring Director blade status 153 Monitoring Control Processor blade (CP8) status 160 Monitoring core switch blade (CR4S-8) status 162 Monitoring power supply status 164 Monitoring blower - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 7
200 Configuring the new chassis serial number 200 Verifying that the blade 224 Installing the FR4-18i blade in the Director 224 Configuring FCIP and Fibre Channel Routing Services and enable the ports 226 Cabling the FR4-18i blade HP StorageWorks DC and DC04 SAN Backbone Director Switches 7 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 8
...236 Battery replacement notice 236 Taiwan battery recycling notice 237 Power cords ...237 Japanese power cord notice 237 D Port numbering templates 239 HP StorageWorks DC SAN Backbone Director Switch templates 239 HP StorageWorks DC04 SAN Backbone Director Switch templates 245 Index 251 8 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 9
27 Removing or replacing the cable management comb 75 28 Director blade (FC8-48 shown 77 29 Director blade filler panel 79 30 Control processor blade (CP8 83 31 Core switch blade (CR8 87 32 Power supply ...89 33 Blower assembly ...91 HP StorageWorks DC and DC04 SAN Backbone Director Switches 9 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 10
51 DC04 SAN Director to DC SAN Director ICL cabling 143 52 FC8-16 Director blade 154 53 FC8-32 Director blade 155 54 FC8-48 Director blade 156 55 FC10-6 Director blade 157 56 FR4-18i router blade 158 58 Control Processor blade (CP8 161 59 Core switch blade (CR4S-8 163 60 Power supply ...165 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 11
with four FC8-32 port blades, two CR4S-8 blades, and two CP8 blades ...247 84 Port side populated with four FC8-16 port blades, two CR4S-8 blades, and two CP8 blades ...248 85 FC10-6 port blades 249 86 FR4-18i router blades 250 HP StorageWorks DC and DC04 SAN Backbone Director Switches 11 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 12
descriptions 72 16 WWN LED patterns 92 17 Commands identifying the WWN card status 92 18 WWN card related system log messages 93 19 Critical information checklist 98 20 Cable routing table for DC SAN Director (48 ports shown 110 21 Blades available for the DC04 SAN Director 118 22 Security - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 13
SAN Director power specifications 216 49 Power cords ...216 50 DC SAN Director environmental requirements 219 51 DC04 SAN Director environmental requirements 220 52 Supported cable speeds and distances 222 53 Hazardous substances 233 HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 14
14 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 15
Setting up and configuring the HP StorageWorks DC SAN Backbone Director Switch (DC SAN Director) and the HP StorageWorks DC04 SAN Backbone Director Switch (DC04 SAN Director) • Maintaining and operating the products • Installing FRUs • Installing the optional blades • Diagnostics and troubleshooting - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 16
conventions Convention Blue text: Table 1 Blue, underlined text: http://www.hp.com Bold text Element Cross-reference links and e-mail addresses Website addresses or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. 16 About this guide - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 17
product at the Subscriber's Choice for Business website: http://www.hp.com/go/wwalerts After registering, you will receive e-mail notification of product enhancements, new driver versions, firmware updates, and other product resources. HP StorageWorks DC and DC04 SAN Backbone Director Switches 17 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 18
http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 18 About this guide - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 19
flexible system configuration • Supports 1-, 2-, 4-, and 8-Gb/s auto-sensing FC ports. Trunking technology groups up to eight ports to create high performance 64-Gb/s ISL trunks between switches. 10 Gb/s ports (FC10-6) are 10 Gb/s only. HP StorageWorks DC and DC04 SAN Backbone Director Switches 19 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 20
at 2 Gb, 4 Gb or 8 Gb.) • Extended Form-factor Pluggable (XFP) optical transceivers (10-Gb/s) • All blades are serviced from the port side of the DC SAN Director. Blowers, power supplies, and power cables are serviced from the non-port side 20 HP StorageWorks DC SAN Backbone Director Switch Overview - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 21
of the port side of the DC SAN Director. 1 2 3 4 5 25369a Figure 1 Port side of the DC SAN Director (sample configuration) 1. Exhaust Vent 3. CP blade (CP8 5. Cable management comb 2. Core switch blade (CR8) 4. FC8-48 Director blade HP StorageWorks DC and DC04 SAN Backbone Director Switches 21 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 22
Director Figure 2 displays a sample configuration of the non-port side view of the DC SAN Director. 1 2 3 25370a Figure 2 Non-port side of the DC SAN Director (sample configuration) 1. WWN bezel (logo plate) 3. Blower assembly 2. Power supply 22 HP StorageWorks DC SAN Backbone Director Switch - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 23
-18i blade integrates sixteen physical FC SFP ports supporting FCR Services and two physical Gigabit Ethernet (GbE) SFP ports supporting Fibre Channel Over IP (FCIP). The two physical GbE ports can support up to sixteen virtual E_ports. HP StorageWorks DC and DC04 SAN Backbone Director Switches 23 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 24
, checksum, and illegal address checking • Power-on self-test (POST) • Dual CP Blades that enable hot, non-disruptive fast firmware upgrades • Each CP Blade contains one serial port and two Ethernet ports, for management and for service. Offline CP Blade diagnostics and remote diagnostics simplify - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 25
Watch Security Class) FC security policies: DCC and SCC Trusted Switch (FCS) for central security management Management access controls (SNMPv3, Telnet, FTP, serial port, front panel) Hardware-enforced zoning by WWN and/or domain/port ID HP StorageWorks DC and DC04 SAN Backbone Director Switches 25 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 26
SMI-S, and Management Server, support a "port N within blade M" naming scheme. The DC SAN Director supports SNMPv1 and SNPMv3. When SNMP devices send SNMP messages to a management console running SAN management software, the information is stored in a Management Information Base (MIB). Fabric OS - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 27
HP StorageWorks DC SAN Director Power Supply Director blades HP StorageWorks SAN Director 16 Port 8Gb FC blade (FC8-16) HP StorageWorks SAN Director 32 Port 8Gb FC blade (FC8-32) HP StorageWorks SAN Director 48 Port 8Gb FC blade (FC8-48) HP StorageWorks SAN Director 6 Port 10Gb FC blade (FC10-6) HP - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 28
OM2 LC/SC Fibre Channel Cable HP 30 m Multi-mode OM2 LC/SC Fibre Channel Cable HP 50 m Multi-mode OM2 LC/SC Fibre Channel Cable Part number 221692-B22 221692-B23 221692-B26 221692-B27 221691-B21 221691-B22 221691-B23 221691-B26 221691-B27 28 HP StorageWorks DC SAN Backbone Director Switch Overview - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 29
power cables and powering on the DC SAN Director 30 minutes 30 minutes 20 minutes See "Installing the DC Director in the 14U Rack Mount Kit" on page 32. Power cables and serial cable (provided in the DC SAN Director accessory kit) HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 30
. Refer to the HP StorageWorks Fabric OS 6.2.x administrator guide for Port Identifier (PID). Site preparation, unpacking the DC SAN Director IMPORTANT: See "Regulatory compliance and safety notices" on page 229 for important safety guidelines before setting up the DC SAN Director. The following - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 31
so that the non-port side has access to intake air (cool). 17. Reinstall the cable management comb. See "Installing a cable management comb" on page 75. 18. Reinstall the chassis door. See "Installing the chassis door" on page 74. HP StorageWorks DC and DC04 SAN Backbone Director Switches 31 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 32
instructions • ESD grounding straps • Two AC power cords appropriate to the country of installation • Two power cord retainers • RS-232 serial cable 14U rack mount kit (includes rear brackets and bottom support rails) IMPORTANT: Order SFP transceivers separately. The DC SAN Director 8Gb port blades - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 33
cm-kgs) For cabinets that have rails with square holes 10-32 retainer nut 1/4-20 x 1/2 in. (1.27 cm) panhead Phillips screw, with glue (torque to 80 in.-lbs, 92 cm-kgs) 0.375 in. (0.953 cm) alignment washer Quantity 1 1 6 6 16 6 16 16 HP StorageWorks DC and DC04 SAN Backbone Director Switches 33 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 34
Figure 3 14U Rack Mount Kit contents 26419a 34 DC SAN Director Installation - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 35
rails adjustable ends installed on the side of the rack on the intake air aisle. 1. Locate the shelf brackets in the 14U Rack Mount Kit. HP StorageWorks DC and DC04 SAN Backbone Director Switches 35 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 36
2. Locate and loosen the adjusting screws on the brackets (see Figure 4, items A and B) to allow for adjustment to cabinet depth. Figure 4 Left and right shelf brackets installed on rails 26420a 36 DC SAN Director Installation - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 37
Shelf bracket and clip or retainer nut placement on cabinet rails 26421a NOTE: Standard EIA rails have holes in sets of three; spaces between the holes are 1.58 cm, 1.58 cm, and 1.27 cm (5/8 in., to a torque of 37 cm-kgs (32 in.-lbs). HP StorageWorks DC and DC04 SAN Backbone Director Switches 37 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 38
nuts are used for securing the port side of the chassis to the rack rails using 10-32 x 5/8-inch screws. Use the DC SAN Director in the cabinet: CAUTION: A fully populated DC SAN Director (eight FC8-48 port cards, 384 ports) weighs supported during the transfer. 38 DC SAN Director Installation - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 39
mounting bracket because the door will interfere with the screw heads. 2 1 Figure 6 Positioning the DC SAN Director for installation in a cabinet 1. Rack cabinet (shown without sheet metal) 2. Air-instake side of chassis 26422a HP StorageWorks DC and DC04 SAN Backbone Director Switches 39 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 40
Figure 7 Attaching port side of chassis to rack rails 26423a Replacing the chassis door To reinstall the chassis door: NOTE: The door is not hinged the door straight into the chassis. 2. Snap the door into place over the ball studs (see Figure 8 and Figure 9). 40 DC SAN Director Installation - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 41
Inside view of door Outside view of door 3 1 2 Figure 9 Inserting DC SAN Director door on chassis ball studs 1. Ball stud on chassis (outside view of door) 3. Ball stud on chassis (inside view of door) 2. Mounting hardware 26425a HP StorageWorks DC and DC04 SAN Backbone Director Switches 41 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 42
1 through 12, from left to right when facing the port side of the DC SAN Director. Control Processor blades (CP8) can be installed only in slots 6 and 7. Core switch blades (CR8) can be installed only in slots 5 and 8. • FC8-16 port blade-ports are numbered from 0 through 15 from bottom to top - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 43
alternate with eight ports marked with oval outlines. See Table 52 on page 222 for a listing of supported cable speeds and distances. Using the optional HP StorageWorks DC SAN Director Inter-Chassis Link (ICL) cable kit You can purchase the optional HP StorageWorks DC SAN Director Inter-Chassis Link - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 44
1 2 LINK ATTN ICL 1 LINK ATTN ICL 0 3 4 LINK ATTN ICL 0 5 1. Status LED 3. LINK LED 5. ICL connector 26378a Figure 10 ICL connectors on CR8 blade 2. Power LED 4. ATTN LED 44 DC SAN Director Installation - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 45
26372a Figure 11 Inter-chassis link (ICL) connections (configuration 1) 1. Chassis 1 3. Core Processor blades (CP8) 5. ICL connector (ICL 1) 7. ICL cables 2. Core switch blades (CR8) 4. Port blades 6. ICL connector (ICL 0) 8. Chassis 2 HP StorageWorks DC and DC04 SAN Backbone Director Switches 45 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 46
1 2 3 4 5 6 7 8 26373a Figure 12 Inter-chassis link (ICL) connections (configuration 2) 1. Chassis 1 3. Core Processor blades (CP8) 5. ICL connector (ICL 1) 7. ICL cables 2. Core switch blades (CR8) 4. Port blades 6.ICL connector (ICL 0) 8. Chassis 2 46 DC SAN Director Installation - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 47
26374a Figure 13 Inter-chassis link (ICL) connections (configuration 3) 1. Chassis 1 3. Core Processor blades (CP8) 5. ICL connector (ICL 1) 7. ICL cables 2. Core switch blades (CR8) 4. Port blades 6.ICL connector (ICL 0) 8. Chassis 2 HP StorageWorks DC and DC04 SAN Backbone Director Switches 47 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 48
1 2 3 4 5 6 7 8 26375a Figure 14 Inter-chassis link (ICL) connections (configuration 4) 1. Chassis 1 3. Core Processor blades (CP8) 5. ICL connector (ICL 1) 7. ICL cables 2. Core switch blades (CR8) 4. Port blades 6.ICL connector (ICL 0) 8. Chassis 2 48 DC SAN Director Installation - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 49
SAN Director To establish a serial connection and log on to the DC SAN Director: 1. Verify that the DC SAN Director is powered on and that POST is complete by verifying that all power LED indicators on the port, control processor, and core switch blades display a steady green light. HP StorageWorks - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 50
SERVICE port on the active CP. Use the serial cable provided with the DC SAN Director to connect the SERVICE port on the active CP to a computer workstation. The active CP blade is indicated by an illuminated (blue) LED. NOTE: The SERVICE port is intended primarily for the initial setting of the IP - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 51
(CP0 and CP1) and for the single logical switch (shown as SWITCH under the ipAddrShow command) in the DC SAN Director. Default IP addresses and password The default IP addresses and host names for the DC SAN Director are: • 10.77.77.75 / CP0 (the CP blade in slot 6 at the time of configuration) • 10 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 52
and replace the shipping cap on the port. Establishing an Ethernet connection NOTE: Connecting the CP blades to a private network/VLAN is recommended. After using a serial connection to configure the IP addresses for the DC SAN Director (see "Configuring IP addresses" on page 51), you can connect - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 53
prompt: Fabric parameters (yes, y, no, n): [no] y 4. Enter a unique Domain ID: Domain: (1.239) [1] 3 5. Complete the remaining prompts or press Ctrl+D to accept the settings and exit. 6. Type switchEnable to re-enable the DC SAN Director. HP StorageWorks DC and DC04 SAN Backbone Director Switches 53 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 54
64-bit chassis ID is required to obtain and activate licenses for the DC SAN Director. The chassis ID is available through the licenseIdShow command. The licenseShow and licenseIdShow commands must be typed through the active CP blade. Refer to the HP StorageWorks Fabric OS 6.2.x administrator guide - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 55
• ipaddrShow • licenseShow • switchShow Keep copies of key data such as passwords, license keys, and IP addresses in a secure location. NOTE: Passwords are not saved in the configuration file, and are not uploaded during a configUpload. HP StorageWorks DC and DC04 SAN Backbone Director Switches 55 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 56
56 DC SAN Director log in and configuration - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 57
diagnostic tests. For information about how to interpret the LED patterns, see Table 9. 3. Type slotShow to check blade status. Table 9 on page 63 describes the Director blade LED patterns and the recommended actions for those patterns. HP StorageWorks DC and DC04 SAN Backbone Director Switches 57 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 58
1 2 3 4 1. Power LED 3. FC port 25362a Figure 15 FC8-16 Director blade 2. Status LED 4. Port status LED 58 Monitoring DC SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 59
1 2 3 4 1. Power LED 3. FC port 25367a Figure 16 FC8-32 Director blade 2. Status LED 4. Port status LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 59 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 60
21 44 20 ! 47 1 2 43 19 42 18 41 17 40 16 39 15 38 14 37 35 13 11 36 12 34 3 10 35 11 33 4 34 9 10 33 32 9 8 32 8 31 7 30 6 29 5 28 4 27 3 26 2 25 1 24 0 25366a Figure 17 FC8-48 Director blade 2. Status LED 4. Port status LED 60 Monitoring DC SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 61
1 2 3 4 1. Power LED 3. FC port 1. Power LED 3. FC port 25368a Figure 18 FC10-6 Director blade 2. Status LED 4. Port status LED 2. Status LED 4. Port status LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 61 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 62
1. Power LED 3. FC port ! 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 GE0 GE1 ! 1 2 7 6 3 5 4 4 FR4 18i 25359a Figure 19 FR4-18i Director blade 2. Status LED 4. Port status LED 62 Monitoring DC SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 63
. Slow-flashing amber (on 2 seconds, then off 2 seconds) Port is disabled due to diagnostic tests or portDisable or portCfgPersistentEnable command. Reset port from workstation using the portEnable or portCfgPersistentEnable command. HP StorageWorks DC and DC04 SAN Backbone Director Switches 63 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 64
on the CP blade (see Figure 21). The LED patterns may temporarily change during POST and other diagnostic tests. For information about how to interpret the LED patterns, see Table 10. 2. Check port blade status by typing slotShow and haShow. 64 Monitoring DC SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 65
1 2 3 4 5 6 7 8 1. Status LED 3. USB LED 5. Console port (10101) 7. Ethernet port (SERVICE) 26401a Figure 21 Control Processor blade (CP8) 2. Power LED 4. USB port 6. Ethernet port (MGMT) 8. Active CP LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 65 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 66
light (LED is off) CP blade is either healthy or does Verify that the power LED is on. not have power. Steady amber CP blade is faulty or the switch is Ensure blade is firmly seated and still booting. switch has completed booting. If LED remains yellow, contact HP. Slow-flashing amber (on CP - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 67
1 2 LINK ATTN ICL 1 LINK ATTN ICL 0 3 4 LINK ATTN ICL 0 5 1. Status LED 3. LINK LED 5. ICL connector 26397a Figure 22 Core switch blade (CR8) 2. Power LED 4. ATTN LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 67 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 68
light (LED is off) CP blade is either healthy or Verify that the power LED is on. does not have power. Steady amber CP blade is faulty or the switch Ensure blade is firmly seated and is still booting. switch has completed booting. If LED remains yellow, contact HP Slow-flashing amber (on 2 CP - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 69
24). The LED patterns may temporarily change during POST and other diagnostic tests; for information about how to interpret the LED patterns, see Table 13. HP StorageWorks DC and DC04 SAN Backbone Director Switches 69 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 70
power. Steady amber Blower assembly has a failure Replace blower assembly. (full or partial). Slow-flashing amber (on Blower assembly is not seated Pull unit out and reseat. If LED con- 2 sec, then off 2 sec) correctly or is faulty. tinues to flash, replace unit. 70 Monitoring DC SAN Director - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 71
): Switch: switchname, Error EMWWN_ABSENT, 2, WWN #1 not present Writing to the FRU history log (hilSetFruHistory) has failed. 0x24c (fabos): Switch: switchname, Error EMHIL_FAIL, 2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT 3 HP StorageWorks DC and DC04 SAN Backbone Director Switches 71 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 72
No light (LED is OFF) Power is OK. Blade is faulty. Blade is OK. No action required Check blade. No action required NOTE: If a blade slot or power supply bay has a filler panel installed, the corresponding LEDs on the WWN blade do not light up. 72 Monitoring DC SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 73
page 79 • "Replacing a core switch blade (CR8)" on page 86 • "Replacing a power supply" on page 88 • "Replacing a blower assembly" on page 89 • "Replacing the WWN bezel (logo plate) and WWN card" on page 91 • "Replacing SFPs and XFPs" on page 96 • "Replacing the DC SAN Director chassis" on page 97 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 74
a #1 Phillips screwdriver. Removing a cable management comb CAUTION: Wear a grounded ESD strap when handling DC SAN Director components. The Director chassis provides a grounding connection above the power connectors. Also, store ESD-sensitive components in antistatic packaging. 74 Replacing DC - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 75
blade takes less than ten minutes. The following items are required for the Director blade and filler panel replacement: • Electrostatic Discharge (ESD) grounding strap • Workstation computer • Replacement Director blade or filler panel HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 76
(identify each cable by its physical port). If multiple blades are being replaced, replace one blade at a time. 7. Ensure that traffic is not flowing through the blade. 8. Disconnect all cables and SFP or XFP transceivers from the blade. 76 Replacing DC SAN Director field-replaceable units (FRUs) - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 77
28 Director blade (FC8-48 shown) Installing a Director blade Slots are numbered from 1 through 12, from left to right when facing the port side of the DC SAN Director. Director blades can be installed in slots 1 through 4 and 9 through 12. HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 78
when handling a Director blade. Use the grounding connections above the power connectors on the chassis. 1. Orient the blade so that the ports are at the front of the chassis and the flat side of the blade is on the left. See Figure 28. 2. FC8-16, FC8-32, FC8-48 Director blades: Adjust the ejectors - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 79
. Each DC SAN Director has two CP8 blades, which are located in slot 6 and slot 7. NOTE: If the new CP blade does not have the same firmware as the active CP blade, you must upgrade the new blade to the active CP blade's firmware version. HP StorageWorks DC and DC04 SAN Backbone Director Switches 79 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 80
the DC SAN Director configuration before you replace a CP blade. Refer to the HP StorageWorks Fabric OS 6.x administrator guide for backup information. To record critical DC SAN Director information: 1. Login to the functioning CP blade as admin, using either a Telnet or a serial console connection - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 81
, Heartbeat Up, HA State Synchronized 5. Type firmwareShow to note the firmware version of the active CP blade. 6. Type haDisable from the active CP blade to prevent failover or communication between the CP blades during the replacement. HP StorageWorks DC and DC04 SAN Backbone Director Switches 81 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 82
IP Address [host]: 123.456.78.90 User Name [None]: user File Name [config.txt]: config.txt Password: xxxxxxxx upload complete Removing a control processor blade (CP8) The DC SAN Director continues to operate while a CP blade is complete. 4. Power off the blade by sliding the slider switch in the top - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 83
handle up, to cover the thumb screw. 5. Verify that the power LED is green. If it is not, ensure that the CP blade has power and is firmly seated and that the ejectors are in the locked position. 6. Connect the cables to the new CP blade. HP StorageWorks DC and DC04 SAN Backbone Director Switches 83 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 84
versions of firmware, please retry firmwaredownload command. swDir:admin> 6. If the firmware version on the replacement blade does not match that on the active CP blade, bring the replacement blade to the same firmware level as the active blade. 84 Replacing DC SAN Director field-replaceable - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 85
Type firmwareDownload -s to download the firmware to one of the CP blades. Enter all requested information (use default values): swDir:admin> firmwaredownload -s Server Name or IP Address: 192.168.100.1 User Name: user File Name: /software/v6.0.0/release.plist Password: ******** Do Auto-Commit - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 86
indicate a problem with a core switch blade • Function fail messages for the core switch blade master For more information about error messages, refer to the Fabric OS Message Reference. Removing a core switch blade (CR8) The DC SAN Director continues to operate while a core switch blade is being - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 87
switch blade inside the lower and upper blade guides in the slot, and then slide the core switch blade into the slot until it is firmly seated (see Figure 31). 3. Tighten the thumb screw inside each handle using the Phillips screwdriver. HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 88
that the core switch blade has power and is firmly seated and that the ejectors are in the locked position. 6. Connect to the new core switch blade. 7. Pack the faulty core switch blade in the packaging provided with the new core switch blade, and contact the DC04 SAN Director supplier for the - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 89
4. Verify that the power LED on the power supply displays a steady green light. 26398a Figure 32 Power supply Replacing a blower assembly IMPORTANT: To ensure Phillips #2 screwdriver Removing a blower assembly To remove a blower assembly: HP StorageWorks DC and DC04 SAN Backbone Director Switches 89 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 90
ESD strap when handling DC SAN Director components. The Director chassis provides a grounding connection above the power connectors. Also, store ESD- The power LEDs should be steady green. 2. Use the screwdriver to loosen the captive screws at the top and bottom of blower assembly. 3. Support the - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 91
status of the components • Power or Status LEDs on WWN card (beneath logo plate) indicate a problem • Problems viewing or modifying the data stored on the WWN card, see Table 17 • Error messages regarding WWN units #1 or #2, see Table 18 HP StorageWorks DC and DC04 SAN Backbone Director Switches 91 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 92
view of the port, CP, and CR blade status (see Table 16). If a blade slot has a filler panel installed, the corresponding LEDs on the WWN card do not light up. Table 16 WWN LED patterns LED location/purpose Color Status Recommended action Director blade/CP/CR blade power Director blade/CP/CR - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 93
The default password is "password". 2. Verify that you are logged into the active CP. Run the haShow command to determine the active CP. 3. Type fruReplace wwn from the active CP blade and wait for the phrase "Do you wish to continue [y/n]?" to display; then type y. HP StorageWorks DC and DC04 SAN - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 94
process is not complete due to a power cycle, or CP failover, please follow the recovery procedure in Core Switch WWN Card Removal and Replacement document. Do you wish to continue [y/n]? Backing up WWN card data, please wait about 25 seconds for further instruction. Please install the new FRU now - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 95
CAUTION: Wear a grounded ESD strap when handling the WWN card. Use the grounding connections above the power connectors on the chassis. 1. Unpack the new WWN card and save the packaging for the faulty WWN on the chassis (see Figure 34). HP StorageWorks DC and DC04 SAN Backbone Director Switches 95 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 96
with the new card and return it to the DC SAN Director supplier. Replacing SFPs and XFPs To remove an SFP or XFP (FC10-6 blade only) transceiver, pull the bale down and out, sliding the transceiver out of the Director blade. To install an SFP or XFP, position one of the transceivers so that the - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 97
pads for protecting all blades and WWN cards • Serial cable and workstation computer with a terminal emulator application (such as HyperTerminal for Windows systems or TIP for Solaris systems), required only if serial console session used HP StorageWorks DC and DC04 SAN Backbone Director Switches 97 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 98
CP8), core switch (CR8), or port blade even though the blade has been replaced. Recording critical DC SAN Director and SAN information All commands for recording critical DC SAN Director and SAN information must be entered from a CLI session (Telnet or serial) to the active CP blade unless otherwise - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 99
. rsl8-st03-dcx-1:admin> configupload Protocol (scp or ftp) [ftp]: ftp Server Name or IP Address [host]: 123.123.123.123 User Name [user]: Admin24 File Name [config.txt]: config-switch0.txt Password: Upload complete rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director Switches 99 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 100
SW BLADE Slot: 1 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: 2 -50 60-0001532-03 KP000000195 Day: 1 Month: 1 Year: 2007 Day: 14 Month: 3 Year: 2012 187 days 3 days 100 Replacing DC SAN Director field - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 101
Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: switch rsl8-st03-dcx-1:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 102
power switches to "0". (The power supply Status LED should turn off.) 3. Remove the power cords from the power supplies and the power outlets. 4. Label the cables connected to all blades and record the connections in Table 20. 5. Disconnect the cables from the port blades and set them aside. The SFP - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 103
SAN Director components and port blades. The chassis provides a grounding connection above the power replacement chassis CAUTION: A fully populated DC SAN Director (eight FC8-48 port cards, 384 ports) weighs approximately 104 kg (228 lbs) HP StorageWorks DC and DC04 SAN Backbone Director Switches 103 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 104
Verify that the DC SAN Director is powered on and POST is complete (all power LED indicators on the port, control processor, and core switch blades should be a Configuring the new chassis serial number To configure a new chassis serial number: 104 Replacing DC SAN Director field-replaceable units ( - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 105
rsl8-st03-dcx-1:root> 3. Verify that the chassis serial number has been entered correctly by typing chassisShow at the prompt. Verifying that the system is operating correctly To verify that the DC SAN Director is operating correctly: HP StorageWorks DC and DC04 SAN Backbone Director Switches 105 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 106
the DC SAN Director as admin: rsl8-st03-dcx-1:admin> login login: admin password: xxxxxxxx rsl8-st03-dcx-1:admin> 2. Type slotShow command and verify that all the installed cards are detected and that their status is operational (enabled). rsl8-st03-dcx-1:admin> slotShow Slot Blade Type ID Status - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 107
CP1 Ethernet IP Address: 10.32.50.11 Ethernet Subnetmask: 255.55.0.0 HostName : cp1 Gateway Address: 10.32.40.1 Backplane IP address of CP0 : 10.0.0.5 Backplane IP address of CP1 : 10.0.0.6 rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director Switches 107 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 108
DC SAN Director is not modified using other connections during the rest of this procedure. 2. Reconnect the transceivers and cables to the port blades: NOTE: The ports and cables used in trunking groups must meet specific requirements. For a list of these requirements, refer to the HP StorageWorks - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 109
:29:46; na Fabric Port Name: 20:0f:00: IP Address [host]: 123.123.123.123 User Name [None]: Admin24 File Name [config.txt]: config-switch.txt Password: xxxxxxxx download complete rsl8-st03-dcx-1:admin> • If other issues exist, contact HP. HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 110
. Expand the table for the number of ports in the DC SAN Director. Table 20 Cable routing table for DC SAN Director (48 ports shown) Slot/port Slot Port Cable labels Switch end Device end Connected device Slot/port of device 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 110 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 111
Slot/port Slot Port 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Cable labels Switch end Device end Connected device Slot/port of device HP StorageWorks DC and DC04 SAN Backbone Director Switches 111 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 112
112 Replacing DC SAN Director field-replaceable units (FRUs) - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 113
to create high performance 64-Gb/s ISL trunks between switches. 10-Gb/s ports (FC10-6) are 10 Gb/s only. • Dual-redundant CP blades (CP8) and core switch blades (CR8) provide high availability and enable non-disruptive software upgrades. HP StorageWorks DC and DC04 SAN Backbone Director Switches 113 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 114
-swappable Director blades: • 16-port, 8-Gb/s blades (FC8-16) • 32-port, 8-Gb/s blades (FC8-32) • 48-port, 8-Gb/s blades (FC8-48) • 6-port, 10-Gb/s blades (FC10-6) • Modular hot-swappable application blades: • FR4-18i, 18-port (16 FC + 2 GbE), up to four blades per chassis, supporting FCR Services - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 115
, 2 Gb or 4 Gb. 8-Gb SFPs operate at 2 Gb, 4 Gb or 8 Gb.) • Extended Form-factor Pluggable (XFP) optical transceivers (10-Gb/s) • All blades are serviced from the port side of the DC04 SAN Director. Blowers, power supplies, and power cables are serviced from the non-port side • World Wide Name (WWN - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 116
Port side of the DC04 SAN Director (sample configuration) 1. FC8-48 port blade 3. Control Processor blade (CP8) 2. Core switch blade (CR4S-8) 4. Exhaust Vent Figure 37 Port side of the DC04 SAN Director with the port side exhaust kit installed 116 HP StorageWorks DC04 SAN Backbone Director Switch - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 117
of the non-port side view of the DC04 SAN Director without the port side exhaust kit installed. Figure 38 Non-port side of the DC04 SAN Director (sample configuration) 1. WWN bezel (logo plate) 3. Blower assembly 2. Power supply HP StorageWorks DC and DC04 SAN Backbone Director Switches 117 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 118
SAN Director, and the DC04 SAN Director. A 6-port Director blade supporting 10-Gb/s port speed. Blade provides 10-Gb/s ISLs. This Director blade is compatible with the 4/256 SAN Director, the DC SAN Director, and the DC04 SAN Director. 118 HP StorageWorks DC04 SAN Backbone Director Switch Overview - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 119
SFP ports supporting FCR Services and two physical Gigabit Ethernet (GbE) SFP ports supporting Fibre Channel Over IP (FCIP). The two physical GbE ports can support up to 16 virtual E_ports. This Director blade is compatible with the 4/256 SAN Director, the DC SAN Director, and the DC04 SAN Director - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 120
• Syslog auditing • Reliable Commit Service (RCS) • Network Time Protocol (NTP) • Tasks to manage address assignment, routing, link initialization, fabric initialization, link shutdown, DC04 SAN Director shutdown, and the user interface. 120 HP StorageWorks DC04 SAN Backbone Director Switch Overview - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 121
own IP address and appears as a separate entity to the Telnet protocol and SNMP. All management interfaces, such as Telnet, Web Tools, standards compliant SMI-S, and Management Server, support a "port N within blade M" naming scheme. HP StorageWorks DC and DC04 SAN Backbone Director Switches 121 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 122
the high performance extension services for either IP or FC connectivity in the B-Series MP Router Blade (FR4-18i). IP and FC extension services are mutually exclusive. This option also includes the Encryption Services license. T4427A 122 HP StorageWorks DC04 SAN Backbone Director Switch Overview - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 123
One HP StorageWorks DC04 SAN Director Power Supply Director blades HP StorageWorks DC SAN Director 16 Port 8Gb FC blade (FC8-16) HP StorageWorks DC SAN Director 32 Port 8Gb FC blade (FC8-32) HP StorageWorks DC SAN Director 48 Port 8Gb FC blade (FC8-48) HP StorageWorks DC SAN Director 6 Port 10Gb - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 124
Accessory HP 50 m Multi-mode OM2 LC/SC Fibre Channel Cable Part number 221691-B27 124 HP StorageWorks DC04 SAN Backbone Director Switch Overview - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 125
on page 128 • "Powering on the DC04 Director" on page 138 • "Port numbering" on page 139 • "Managing cables" on page 139 • "Using the optional HP StorageWorks DC SAN Backbone Director Inter-Chassis Link (ICL) cable kit" on page 140 Time and items required for installation You can set up and install - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 126
to the HP StorageWorks Fabric OS 6.2.x administrator guide for Port Identifier (PID) information. Site preparation, unpacking the DC04 SAN Director IMPORTANT: See "Regulatory compliance and safety notices" on page 229 for important safety guidelines before setting up your DC04 SAN Director. The - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 127
with the power cords TIP: To maximize fault tolerance, connect each power cord to a separate power source. 5. port side exhaust kit, shipping bracket kit, accessory kit, packing foam, and antistatic plastic from the chassis and set aside. HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 128
door The accessory kit includes: • HP StorageWorks product documentation • ESD grounding strap • RS-232 serial cable, with an adapter at one end to provide an RJ-45-style connector IMPORTANT: Order SFP transceivers separately. The DC04 SAN Director supports SWL, LWL, and ELWL transceivers. See - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 129
that have rails with round holes 8 G 10-32 retainer nut for cabinets that have rails with square holes 8 H Alignment washer for cabinets that have rails with square holes 12 I 6-32 x 0.635 cm (0.25 in.) Phillips screw 2 HP StorageWorks DC and DC04 SAN Backbone Director Switches 129 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 130
hardware Torque requirements Use the torque settings listed in Table 28 when tightening screws that secure the rack mount kit and DC04 SAN Director to the equipment cabinet. Table 28 Torque requirements Screw size 6-32 x .635 cm (0.25 in. ) Phillips screw 10-32 x 1.60 cm 0(.63 in.) Phillips screw - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 131
Installing the cabinet hardware 1. Position the DC04 SAN Director in the equipment cabinet so that the non-port side has access to cool intake air. HP StorageWorks DC and DC04 SAN Backbone Director Switches 131 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 132
2. Install the mounting nuts in the cabinet rail locations shown in Figure 40. These nuts secure the 10-32 screws that mount the port-side exhaust kit shelf and DC04 SAN Director to the cabinet. • For rails with round holes-Install the clip nuts (F in Figure 39). • For rails with square holes- - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 133
to 31 inches) to accommodate the cabinet size. To lengthen or shorten the shelf, loosen the four 6-32 screws in the four slots on the shelf (I-4 through I-7 in Figure 39, page 130) and adjust . Figure 42 Installing the air-duct assembly HP StorageWorks DC and DC04 SAN Backbone Director Switches 133 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 134
10-32 screws (D in Figure 39, page 130) with blue Loctite on the threads and alignment washers (H in Figure 39, page 130) on each end of the top-rail assembly. Installing the DC04 SAN Director in the cabinet CAUTION: A fully populated DC04 SAN Director weighs 68 kg (150 lb) with four FC8-48 port - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 135
the 10-32 screws. Tighten the screws according to the specifications listed in Table 28, page 130. Figure 44 Installing the DC04 SAN Director in the cabinet 6. Reinstall the chassis door. See Installing the chassis door, page 170. HP StorageWorks DC and DC04 SAN Backbone Director Switches 135 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 136
sets of discrete holes, marked 27 through 31. Use the holes that correspond with the cabinet's rail-to-rail depth. See Table 29. Tighten the screws to 10 in/lbs. 3. Install the DC04 SAN Director the port-side rack brackets. 5. Secure the L-brackets to the cabinet rails using the six 10-32 panhead - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 137
Figure 45 DC04 SAN Director shipping brackets (left side) Figure 46 Installing the shipping brackets on the DC04 SAN Director HP StorageWorks DC and DC04 SAN Backbone Director Switches 137 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 138
the required voltage, and is properly grounded. To power on the DC04 SAN Director: 1. Connect the AC power cords to the power supply assemblies. One to four power cords are required, depending on electrical service. 2. Connect the power cords to a power source with voltage of 200 to 240 VAC, 47 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 139
paths to prevent cables from hanging down in front of other blades. See Figure 48. Follow these cabling recommendations: • Leave at least 1 m (3.28 ft) of slack for each port cable. This provides room to remove and replace the switch. HP StorageWorks DC and DC04 SAN Backbone Director Switches 139 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 140
switch through the cable management fingers. • Route port cables and other cables away from the LEDs to ensure that the LEDs are visible. Figure 48 Vertical cable management finger assemblies Using the optional HP StorageWorks DC SAN Director Because the blades in the DC04 SAN Director are installed - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 141
chassis and the slot 6 CR4S-8 blade on the second chassis as long as the left-to-right (top-to-bottom) rule is followed. 1. Status LED 3. LINK LED 5. ICL connector Figure 49 ICL connectors on CR4S-8 blade 2. Power LED 4. ATTN LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 141 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 142
Figure 50 DC04 SAN Director ICL cabling 1. Chassis 1 2. Core Switch blades (CR4S-8) 3. Control Processor blades (CP8) 4. Port blades 5. ICL connector (ICL1) 6. ICL connector (ICL 0) 7. ICL cables 8. Chassis 2 142 DC04 SAN Director Installation - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 143
DC04 SAN Director to DC SAN Director ICL cabling 1. DC04 SAN Director chassis 2. Core Switch blades (CR4S-8) 3. Control Processor blades (CP8) 4. Port blades 5. ICL connector (ICL1) 6. ICL connector (ICL 0) 7. ICL cables 8. DC SAN Director chassis HP StorageWorks DC and DC04 SAN Backbone Director - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 144
144 DC04 SAN Director Installation - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 145
• IP addresses, host names, subnet masks, and gateway addresses for both CP blades • Switch name • Domain ID for the DC04 SAN Director (optional) • WWN for the DC04 SAN Director The DC04 SAN Director WWN is initially set by the factory to match the license ID (which is based on the chassis serial - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 146
the serial cable provided with the DC04 SAN Director to connect the CONSOLE port on the active CP to a computer workstation. The active CP blade is indicated by an illuminated (blue) LED. NOTE: The CONSOLE port is intended primarily for the initial setting of the IP address and for service purposes - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 147
(CP0 and CP1) and for the single logical switch (shown as SWITCH under the ipAddrShow command) in the DC04 SAN Director. Default IP addresses and password The default IP addresses and host names for the DC04 SAN Director are: • 10.77.77.75 / CP0 (the CP blade in slot 4 at the time of configuration - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 148
and replace the shipping cap on the port. Establishing an Ethernet connection NOTE: Connecting the CP blades to a private network/VLAN is recommended. After using a serial connection to configure the IP addresses for the DC04 SAN Director (see "Configuring IP addresses" on page 147), you can connect - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 149
: Fabric parameters (yes, y, no, n): [no] y 4. Enter a unique domain ID: Domain: (1.239) [1] 3 5. Complete the remaining prompts or press Ctrl+D to accept the settings and exit. 6. Type switchEnable to re-enable the DC04 SAN Director. HP StorageWorks DC and DC04 SAN Backbone Director Switches 149 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 150
and time; a switch with an incorrect date and time value still functions properly. However, because the date and time are used for logging, error detection, and troubleshooting, they should be set correctly. Setting the date To set the date: 1. If necessary, log on to the DC04 SAN Director by Telnet - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 151
IP address or DNS name of the first NTP server, which the switch must be able to access. The variable ntp2 is the second NTP server and is optional. The operand "" is optional; by default through 3 for the remaining ports. HP StorageWorks DC and DC04 SAN Backbone Director Switches 151 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 152
licenseShow and licenseIdShow commands must be typed through the active CP blade. Refer to the HP StorageWorks Fabric OS 6.2.x administrator guide. Backing up the configuration Save all key configuration data for the DC04 SAN Director, including license key information, and upload it to a host for - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 153
tests. For information about how to interpret the LED patterns, see Table 30. 3. Type slotShow to check blade status. Table 30 on page 159 describes the Director blade LED patterns and the recommended actions for those patterns. HP StorageWorks DC and DC04 SAN Backbone Director Switches 153 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 154
1. Power LED 3. FC port Figure 52 FC8-16 Director blade 2. Status LED 4. Port status LED 154 Monitoring DC04 SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 155
1. Power LED 3. FC port Figure 53 FC8-32 Director blade 2. Status LED 4. Port status LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 155 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 156
1. Power LED 3. FC port Figure 54 FC8-48 Director blade 2. Status LED 4. Port status LED 156 Monitoring DC04 SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 157
1. Power LED 3. FC port Figure 55 FC10-6 Director blade 2. Status LED 4. Port status LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 157 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 158
1. Power LED 3. FC port Figure 56 FR4-18i router blade 2. Status LED 4. Port status LED 158 Monitoring DC04 SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 159
. Slow-flashing amber (on 2 seconds, then off 2 seconds) Port is disabled due to diagnostic tests or portDisable or portCfgPersistentEnable command. Reset port from workstation using the portEnable or portCfgPersistentEnable command. HP StorageWorks DC and DC04 SAN Backbone Director Switches 159 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 160
is bypassed Recommended action Change transceiver or reset switch from workstation. Reset port from workstation using the portEnable or portCfgPersistentEnable command. Monitoring Control Processor blade (CP8) status To determine the status of a CP8 blade: 1. Check the LED indicators on the CP - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 161
1. Status LED 3. USB LED 5. Console port (10101) 7. Ethernet port (SERVICE) 2. Power LED 4. USB port 6. Ethernet port (MGMT) 8. Active CP LED Table 31 describes the CP blade LED patterns and the recommended actions for those patterns. HP StorageWorks DC and DC04 SAN Backbone Director Switches 161 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 162
the core switch blade (see Figure 59). The LED patterns may temporarily change during POST and other diagnostic tests; for information about how to interpret the LED patterns, see Table 32. 2. Check the core switch blade status by typing slotShow and haShow. 162 Monitoring DC04 SAN Director system - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 163
1. Status LED 3. LINK LED 5. ICL connector Figure 59 Core switch blade (CR4S-8) 2. Power LED 4. ATTN LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 163 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 164
light (LED is off) CP blade is either healthy or Verify that the power LED is on. does not have power. Steady amber CP blade is faulty or the switch Ensure blade is firmly seated and is still booting. switch has completed booting. If LED remains yellow, contact HP Slow-flashing amber (on 2 CP - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 165
61). The LED patterns may temporarily change during POST and other diagnostic tests; for information about how to interpret the LED patterns, see Table 34. HP StorageWorks DC and DC04 SAN Backbone Director Switches 165 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 166
is also provided. If a blower assembly is absent or faulty, contact HP. Figure 61 Blower assembly 1. Power LED 2. Fault LED Table 34 Blower assembly LED descriptions LED purpose Color Status or is faulty. tinues to flash, replace unit. 166 Monitoring DC04 SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 167
): Switch: switchname, Error EMWWN_ABSENT, 2, WWN #1 not present Writing to the FRU history log (hilSetFruHistory) has failed. 0x24c (fabos): Switch: switchname, Error EMHIL_FAIL, 2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT 3 HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 168
Figure 62 WWN bezel (logo plate) 168 Monitoring DC04 SAN Director system components - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 169
into receiving hardware on the door in the cabinet. 1. Grip the side of the door. Support the door to prevent it from falling. 2. Gently pull the door straight out from the chassis until it snaps out of the ball studs on the chassis. HP StorageWorks DC and DC04 SAN Backbone Director Switches 169 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 170
management fingers. Due to the horizontal orientation of the blades in the DC04 SAN Director, the finger assemblies are attached to the uprights of strap when handling DC04 SAN Director components. The DC04 SAN Director chassis provides a grounding connection above the power connectors. Also, store - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 171
• Replacement DC04 SAN Director blade or filler panel • Phillips screwdriver • Small form-factor pluggable (SFP) or extended form-factor pluggable (XFP, FC10-6 Director blade only) transceivers (as needed) • Optical cables (as needed) HP StorageWorks DC and DC04 SAN Backbone Director Switches 171 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 172
identifying each cable by its physical port. If multiple blades are being replaced, replace one blade at a time. 7. Ensure that traffic is not flowing through the blade. 8. Disconnect all cables and SFP or XFP transceivers from the blade. 9. FC8-16, FC8-32, FC8-48 blades: Adjust the ejectors to the - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 173
ESD strap when handling a blade. Use the grounding connections above the power connectors on the chassis. 1. Orient the blade so that the ports are at the front of the chassis and the flat side of the blade is on the left. See Figure 65. HP StorageWorks DC and DC04 SAN Backbone Director Switches 173 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 174
Open the ejectors to approximately 45 degrees, align the flat side of the port blade inside the left and right rail guides in the slot, and slide the blade into the slot until it is firmly seated. 3. FC8-16, FC8-32, FC8-48 blades: Adjust the ejectors to the closed position by pulling them away from - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 175
. The following items are required for the CP blade replacement: • ESD grounding strap • Workstation computer • Serial cable • IP address of an FTP server for backing up the DC04 SAN Director configuration • Phillips #2 screwdriver HP StorageWorks DC and DC04 SAN Backbone Director Switches 175 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 176
before you replace a CP blade. Refer to the HP StorageWorks Fabric OS 6.2.x administrator guide for backup information. To record critical DC04 SAN Director information: 1. Login to the functioning CP blade as admin, using either a Telnet or a serial console connection. 2. Type haShow to - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 177
, Heartbeat Up, HA State Synchronized 5. Type firmwareShow to note the firmware version of the active CP blade. 6. Type haDisable from the active CP blade to prevent failover or communication between the CP blades during the replacement. HP StorageWorks DC and DC04 SAN Backbone Director Switches 177 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 178
IP Address [host]: 123.456.78.90 User Name [None]: user File Name [config.txt]: config.txt Password: xxxxxxxx upload complete Removing a control processor blade (CP8) The DC04 SAN Director continues to operate while a CP blade complete. 4. Power off the blade by sliding the slider switch in the top - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 179
the left, to cover the thumb screw. 5. Verify that the power LED is green. If it is not, ensure that the CP blade has power and is firmly seated and that the ejectors are in the locked position. 6. Connect the cables to the new CP blade. HP StorageWorks DC and DC04 SAN Backbone Director Switches 179 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 180
versions of firmware, please retry firmwaredownload command. swDir:admin> 6. If the firmware version on the replacement blade does not match that on the active CP blade, bring the replacement blade to the same firmware level as the active blade. 180 Replacing DC04 SAN Director field-replaceable - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 181
Type firmwareDownload -s to download the firmware to one of the CP blades. Enter all requested information (use default values): swDir:admin> firmwaredownload -s Server Name or IP Address: 192.168.100.1 User Name: user File Name: /software/v6.2.0/release.plist Password: ******** Do Auto-Commit - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 182
that indicate a problem with a core switch blade • Function fail messages for the core switch blade master For more information about error messages, refer to the Fabric OS Message Reference. Removing a core switch blade The DC04 SAN Director continues to operate while a core switch blade is being - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 183
. 6. Connect to the new core switch blade. 7. Pack the faulty core switch blade in the packaging provided with the new core switch blade, and contact the DC04 SAN Director supplier for the procedure for returning the faulty blade. HP StorageWorks DC and DC04 SAN Backbone Director Switches 183 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 184
supply slot at all times to ensure power to the DC04 SAN Director. 2. Turn off the power switch. 3. Remove the power cord. 4. Loosen the thumb screw. 5. Grasp the handle and pull, sliding the power supply from the chassis and supporting the power supply from beneath as you remove it (see Figure - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 185
power cord. 5. Turn on the power switch. 6. Verify that the power LED on the power supply displays a steady green light. Figure 70 Power supply Replacing a blower assembly IMPORTANT: The DC04 SAN Director • Phillips #2 screwdriver HP StorageWorks DC and DC04 SAN Backbone Director Switches 185 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 186
assembly To remove a blower assembly: CAUTION: Wear a grounded ESD strap when handling DC04 SAN Director components. The Director chassis provides a grounding connection above the power connectors. Also, store ESD-sensitive components in antistatic packaging. 1. Before removing a blower assembly - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 187
• If a serial console session is used: serial cable and a Problems viewing or modifying the data stored on the WWN card, see Table 37 • Error messages regarding WWN units #1 or #2, see Table 38 To determine the status of a WWN card: HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 188
WWN card Use the following commands wwn, chassisShow chassisShow Ethernet and Fibre Channel IP address information for the CP blades History log information Name of switch ipAddrShow, ipAddrSet historyShow, historyLastShow switchName 188 Replacing DC04 SAN Director field-replaceable units (FRUs) - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 189
from the chassis and set it aside. The WWN cards and their status LEDs are visible. See Figure 72 4. Type fruReplace wwn from the active CP blade and wait for the phrase Do you wish to continue [y/n]? to be displayed, and then type y. HP StorageWorks DC and DC04 SAN Backbone Director Switches 189 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 190
process is not complete due to a power cycle, or CP failover, please follow the recovery procedure in Core Switch WWN Card Removal and Replacement document. Do you wish to continue [y/n]? Backing up WWN card data, please wait about 25 seconds for further instruction. Please install the new FRU now - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 191
WWN card. Use the grounding connections above the power connectors on the chassis. 1. Unpack the new serial console session is active, several removal detected and insertion detected messages display on the console because of the replacement. HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 192
with the new card and return it to the DC04 SAN Director supplier. Replacing SFPs and XFPs NOTE: The 8-Gb/s SFPs autonegotiate at 2-, 4-, and 8-Gb/s. The 4-Gb/s SFPs autonegotiate at 1-, 2-, and 4-Gb/s. To remove an SFP or XFP (FC10-6 blade only) transceiver, pull the bale down and out, sliding the - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 193
for protecting all blades and WWN cards • Serial cable and workstation computer with a terminal emulator application (such as HyperTerminal for Windows systems or TIP for Solaris systems), required only if serial console session used HP StorageWorks DC and DC04 SAN Backbone Director Switches 193 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 194
processor (CP8), core switch (CR4S8), or port blade even though the blade has been replaced. Recording critical DC04 SAN Director and SAN information All commands for recording critical DC04 SAN Director and SAN information must be entered from a CLI session (Telnet or serial) to the active CP - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 195
rsl8-st03-dcx-1:admin> configupload Protocol (scp or ftp) [ftp]: ftp Server Name or IP Address [host]: 123.123.123.123 User Name [user]: Admin24 File Name [config.txt]: config-switch0.txt Password: Upload complete rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director Switches 195 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 196
SW BLADE Slot: 1 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: 2 -50 60-0001532-03 KP000000195 Day: 1 Month: 1 Year: 2007 Day: 14 Month: 3 Year: 2012 187 days 3 days 196 Replacing DC04 SAN Director field - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 197
Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: switch rsl8-st03-dcx-1:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 198
the power outlets. 4. Label the cables connected to all blades and record the connections in Table 40. 5. Remove the chassis door. 6. Disconnect the cables from the port blades and set them aside. The SFP or XFP transceivers can be left in the port blades or removed. 198 Replacing DC04 SAN Director - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 199
SAN Director components and port blades. The Director chassis provides a grounding connection above the power chassis CAUTION: A fully populated DC04 SAN Director (four FC8-48 port cards, 192 ports) weighs approximately 68 kg (150 lbs HP StorageWorks DC and DC04 SAN Backbone Director Switches 199 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 200
that the DC04 SAN Director is powered on and POST is complete (all power LED indicators on the port, control processor, and core switch blades should be a Configuring the new chassis serial number To configure a new chassis serial number: 200 Replacing DC04 SAN Director field-replaceable units ( - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 201
rsl8-st03-dcx-1:root> 3. Verify that the chassis serial number has been entered correctly by typing chassisShow at the prompt. Verifying that the system is operating correctly To verify that the DC04 SAN Director is operating correctly: HP StorageWorks DC and DC04 SAN Backbone Director Switches 201 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 202
50 ENABLED 6 CORE BLADE 52 ENABLED 7 UNKNOWN VACANT 8 SW BLADE 55 ENABLED rsl8-st03-dcx-1:admin> 3. Verify that the DC04 SAN Director is functioning correctly by typing switchShow or switchStatusShow. This switchShow command displays DC04 SAN Director and port status information. rsl8 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 203
DC04 SAN Director can be accessed by remote connection using any of the available management tools, such as Telnet or Web Tools. Ensure that the DC04 SAN Director is not modified using other connections during the rest of this procedure. HP StorageWorks DC and DC04 SAN Backbone Director Switches 203 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 204
2. Reconnect the transceivers and cables to the port blades: NOTE: The ports and cables used in trunking groups must meet specific requirements. For a list of these requirements, refer to the HP StorageWorks Fabric OS 6.2.x administrator guide. a. Position one of the transceivers so that the key is - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 205
-01 rsl8-st03-dcx-1:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name rsl8-st03-dcx-1:admin> • Number of devices • ISL and port states • Number of switches in the fabric HP StorageWorks DC and DC04 SAN Backbone Director Switches 205 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 206
[config.txt]: config-switch.txt Password: xxxxxxxx download complete rsl8-st03-dcx-1:admin> • If other issues exist, contact HP. Cable routing table Table 40 is a 48-port template for a cable-routing table. Expand the table for the number of ports in the DC04 SAN Director. Table 40 Cable routing - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 207
Slot/port Slot Cable labels Port 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Switch end Device end Connected device Slot/port of device HP StorageWorks DC and DC04 SAN Backbone Director Switches 207 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 208
Slot/port Slot Cable labels Port 41 42 43 44 45 46 47 48 Switch end Device end Connected device Slot/port of device 208 Replacing DC04 SAN Director field-replaceable units (FRUs) - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 209
with FC-SW 5.0 Complies with FC-IP 2.3 of the FCA profile DC SAN Director: 6144 Gb/s, end-to-end DC04 SAN Director: 3 Tbps per chassis Port to port latency Less than 2 microseconds with no contention (destination port is free) HP StorageWorks DC and DC04 SAN Backbone Director Switches 209 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 210
Aggregate bandwidth Switch latency Can use up to 8 ports in a trunk group to form a 64 Gb/s trunk 6144 Gb/s, end-to-end, when using eight FC4-48 port blades FC8-16 blade: - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 211
Monitoring, FICON CUP, ACL (Access Control Lists), Admin Domains, Reliable Commit Service, NTP, Syslog, RASlog, auditing Inter-chassis linking (ICL) Chassis-to-chassis linkage through connectors on the core switch blade (CR8) HP StorageWorks DC and DC04 SAN Backbone Director Switches 211 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 212
Switch latency Can use up to 8 ports in a trunk group to form a 64 Gb/s trunk 3 Tbps per chassis FC8-16 blade: - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 213
in.) 61.24 cm (24.11 in./8U) 68.90 cm (27.12 in./9U) with Port Side Exhaust Kit Depth Depth (with door) DC04 SAN Director: 192-port configuration with four FC8-48 port blades 61.29 cm (24.09 in.) 73.20 cm (28.82 in.) 68 kg (150 lb.) HP StorageWorks DC and DC04 SAN Backbone Director Switches 213 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 214
FRU CP blade (CP8) CR blade (CR8, CR4S-8) FC8-16 port blade FC8-32 port blade FC8-48 port blade FC10-6 port blade FR4-18i application blade Port card filler panel Power supply Blower assembly WWN bezel Cable management comb (DC SAN Director) Vertical cable management fingers (DC04 SAN Director) WWN - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 215
port blades, two CP8 blades, two CR8 blades, and three blower assemblies.. Table 47 DC SAN Director power specifications Specification Input voltage Supported power range Input frequency range Power supplies (each) AC inrush current Ride through Under voltage protection Value A fully loaded switch - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 216
, peak AC power consumption is configuration-specific. A system with four FC8-48 port blades (loaded with 1W SFPs), two CP8 blades, two CR4S-8 blades, and two blower assemblies consumes 841W. Power cords The types of power cords provided with the DC SAN Director and DC04 SAN Director are specific - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 217
Czech, Rep. of X Denmark X Egypt X England X Finland X X France X Germany X Greece X Hong Kong X Hungary X India X Indonesia X Ireland, North X Ireland, South X Israel X Italy X Japan X Korea, South X HP StorageWorks DC and DC04 SAN Backbone Director Switches 217 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 218
Country Plug style NEMA L6-20 USA, Canada, Mexico, other North American locations CEE-7/7 "Schuko" Continental Europe/Ireland BS-1363A United Kingdom/ Hong Kong AS 3112 Australia/New Zealand IEC-60309 32A-6h, 230 V~ Malaysia Alternate Mexico X Monaco X Netherlands New Zealand Norway - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 219
, 11ms duration, half-sine wave Acceptable range during non-operation -40° to +70° C outside switch (-40° to 158° F) 10% to 93% RH noncondensing, at 70° Celsius 0 to 12 km (40,000 ft.) above sea level 33G, 11ms duration, half-sine wave HP StorageWorks DC and DC04 SAN Backbone Director Switches 219 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 220
or 2869 BTU/hr (Four FC8-48 blades, two CP8 blades, and two CR4S-8 blades) Not applicable. NOTE: The 10° to 40° Celsius range applies to the ambient air temperature at the air intake vents on the non-port side of the DC SAN Director or DC04 SAN Director. The temperature inside the product chassis - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 221
of becoming F_Ports (fabric ports), FL_Ports (fabric loop enabled), or E_Ports (expansion ports). The ports meet all required safety standards. For a listing of these standards, see "Regulatory compliance and safety notices" on page 229. HP StorageWorks DC and DC04 SAN Backbone Director Switches 221 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 222
Data transmission ranges Table 52 provides the data transmission ranges for different cable types and port speeds. Table 52 Supported cable speeds and distances Cable type Speed Single Mode 9 microns 2 Gb/s 4 Gb/s 8 Gb/s Multi Mode 50 microns 2 Gb/s 4 Gb/s 8 Gb/s 62.5 microns 2 Gb/s 4 Gb - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 223
in the DC SAN Director and the DC04 SAN Director. The optional B-Series MP Router blade (FR4-18i) integrates sixteen physical Fibre Channel SFP ports supporting the Fibre Channel Routing Services, and two physical Gigabit Ethernet (GbE) SFP ports supporting the Fibre Channel Over IP (FCIP) feature - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 224
SFP transceivers • Two SFP transceivers for the GbE ports Installing and configuring the FR4-18i blade To configure the FR4-18i, complete the following tasks: 1. "Installing the FR4-18i blade into the Director" on page 224 2. "Configuring FCIP and Fibre Channel Routing Services and enable the ports - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 225
1. Blade power LED 3. FC port 5. Thumb screw 7. ON/OFF slider switch 9. GbE ports (2) 11. Lower ejector 13. GbE port status LED 2. Blade status LED 4. Upper ejector. 6. FC port status LED 8. FC port 10. Thumb screw 12. FC port status LED HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 226
the VE_Ports. See the HP StorageWorks Fabric OS 6.2.x administrator guide for detailed instructions on configuring the Fibre Channel Router ports and GbE ports on the FR4-18i blade. Cabling the FR4-18i blade To complete the switch configuration: 1. Install the SFP transceivers in the Fibre Channel - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 227
management before installing the blade. • Leave at least one meter of slack for each port cable. This provides room to remove and replace the blades, and helps prevent the cables from being bent to less than the minimum bend radius. HP StorageWorks DC and DC04 SAN Backbone Director Switches 227 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 228
228 Intelligent blades - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 229
installed and used in accordance with the instruction manual, may cause harmful interference to radio not expressly approved by Hewlett-Packard Company may void the user's authority to operate the equipment. Cables Connections to HP StorageWorks DC and DC04 SAN Backbone Director Switches 229 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 230
to open the laser device enclosure. There are no user-serviceable components inside. • Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. • Allow only HP authorized service technicians to repair the laser device. Certification and - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 231
optional label in Figure 75 or equivalent may be located on the surface of the HP supplied laser device. This label indicates that the product is classified as a CLASS GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany HP StorageWorks DC and DC04 SAN Backbone Director Switches 231 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 232
Japanese notice Korean notices Korean Notice 232 Regulatory compliance and safety notices - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 233
HP StorageWorks DC SAN Backbone Director Switch and the HP StorageWorks DC04 SAN Backbone Director Switch Brocade provides with respect to its products as set forth in the applicable contract between Brocade and its customer. Brocade manual of the product. EPUP EPUP FRU Brocade Brocade - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 234
(PBB) Polybrominated Diphenyl Ether (PBDE) Fan, Blower assemblies X O O O O O PCBA cards X O O O O O Power Supply kit X O O O O O SFPs (optical cable connectors) X O O O O O Sheet Metal X O O O O O Chassis Assembly X O O O O O Mechanical brackets and - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 235
. Electrostatic discharge recommendations To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may HP StorageWorks DC and DC04 SAN Backbone Director Switches 235 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 236
part designated for this product. For more information about battery replacement or proper disposal, contact an HP authorized reseller or HP authorized service provider. WARNING! Your switch contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. There is - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 237
the recovery marks on the batteries used in sales, giveaway or promotion. Contact a qualified Taiwanese recycler for proper battery disposal. Power cords The power cord set must cords exit from the product. Japanese power cord notice HP StorageWorks DC and DC04 SAN Backbone Director Switches 237 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 238
238 Regulatory compliance and safety notices - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 239
SAN Director or DC04 SAN Director. HP StorageWorks DC SAN Backbone Director Switch templates The following port templates are provided for the DC SAN Director: • Port side populated with eight FC8-48 port blades, two CR8 blades, and two CP8 blades • Port side populated with eight FC8-32 port blades - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 240
Figure 76 Port side populated with eight FC8-48 port blades, two CR8 blades, and two CP8 blades 240 Port numbering templates - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 241
26389a Figure 77 Port side populated with eight FC8-32 port blades, two CR8 blades, and two CP8 blades HP StorageWorks DC and DC04 SAN Backbone Director Switches 241 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 242
26388a Figure 78 Port side populated with eight FC8-16 port blades, two CR8 blades, and two CP8 blades 242 Port numbering templates - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 243
Figure 79 FC10-6 port blades HP StorageWorks DC and DC04 SAN Backbone Director Switches 243 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 244
Figure 80 FR4-18i router blade 244 Port numbering templates - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 245
HP StorageWorks DC04 SAN Backbone Director Switch templates The following port templates are provided for the DC04 SAN Director: • Port side populated with four FC8-48 port blades, two CR4S-8 blades, and two CP8 blades • Port side populated with four FC8-32 port blades, two CR4S-8 blades, and two - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 246
Figure 82 Port side populated with four FC8-48 port blades, two CR4S-8 blades, and two CP8 blades 246 Port numbering templates - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 247
Figure 83 Port side populated with four FC8-32 port blades, two CR4S-8 blades, and two CP8 blades HP StorageWorks DC and DC04 SAN Backbone Director Switches 247 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 248
Figure 84 Port side populated with four FC8-16 port blades, two CR4S-8 blades, and two CP8 blades 248 Port numbering templates - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 249
Figure 85 FC10-6 port blades HP StorageWorks DC and DC04 SAN Backbone Director Switches 249 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 250
Figure 86 FR4-18i router blades 250 Port numbering templates - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 251
blade, DC04 See CP blade, DC04, 113 conventions document, 16 text symbols, 16 cord. See power cord, 237 core switch blade, DC04 See CR blade, DC04, 113 core switch blade, DC See CR blade, DC, 19 CP blade, DC replacing, 79 status, 64 HP StorageWorks DC and DC04 SAN Backbone Director Switches - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 252
ranges, 222 DC SAN Director port numbering templates, 239 blades available for, 23 environmental requirements, 219 features, 19 hardware components, 20 high availability features, 24 installation tasks, 29 IP address, 51 network manageability features, 26 power requirement, 215 powering on, 42 rack - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 253
panel replacing, 174 power supply, 164 power supply LEDs, 165 replacing, 184 WWN bezel replacing, 187 WWN card replacing, 187 H hardware components, DC, 20 hardware components, DC04, 114 hardware kits, DC, 27 hardware kits, DC04, 123 HP StorageWorks DC and DC04 SAN Backbone Director Switches 253 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 254
, 42 ports, DC04 numbering, 139 power supply, DC status, 68 power supply, DC04 status, 164 power cord compliance notice, 237 current rating, 237 replacement, 237 set, 237 voltage rating, 237 power cords specifications, 216 power requirements DC SAN Director, 215 DC04 SAN Director, 215 power supply - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 255
Fibre Channel port, 220 power cords, 216 status, port blade, DC, 57 status, port blade, DC04, 153 Subscriber's Choice, HP, 17 switch name, DC, customizing, 53 switch name, DC04, customizing, 149 symbols in text, 16 system architecture, DC SAN Director, 210 system architecture, DC04 SAN Director, 212 - HP StorageWorks 4/8 | HP StorageWorks DC and DC04 SAN Backbone Director Switches - Page 256
256
HP StorageWorks DC and DC04 SAN
Backbone Director Switches
hardware reference guide
Part number: 5697–7814
Second edition: February 2009