HP StorageWorks 4000 RAID Array 4000 Redundant Configuration Poster

HP StorageWorks 4000 - RAID Array Manual

HP StorageWorks 4000 manual content summary:

  • 1
  • 2

To install the Compaq StorageWorks RAID Array 4000 redundant
components, you will need to perform the following procedures:
1.
Shut down the server and the storage system.
2.
Install the RA4000 Redundant Controller
by completing these steps:
A.
Remove the blank panel located at the rear of the
RA4000.
B.
Insert the RA4000 Redundant Controller into the
tracks in the rear panel opening.
C.
Push the board in as far as it will go and close both
latches against the rear panel. The levers on each
latch should catch behind the metal lip, drawing the
board into position and securing it into place.
3.
Install the second Compaq Fibre Channel Storage Hub in the
rack or other location. Refer to the documentation supplied
with this device for details.
4.
Install the second Compaq Fibre Channel Host Adapter
in a convenient slot in the server. Refer to the
Compaq
StorageWorks Fibre Channel Host Adapter Installation Guide
.
5.
Install the GigaBit Interface Converter (GBIC) modules in
the receptacles provided on the Fibre Channel host adapter,
RA4000 Controllers, and Fibre Channel Hubs.
©1999 Compaq Computer Corporation.
All rights reserved. Printed in the U.S.A.
Compaq, ProLiant, ProSignia, and ROMpaq
registered United States Patent and Trademark Office.
First Edition (June 1999)
Part Number 340426-001
340426- 001
RA4000 Controller
RA4000 Array
GigaBit Interface Converters
Fibre Channel Host Adapters
Fibre Channel Storage Hub 7 or 12
Server
6.
Connect the Fibre Channel host adapter, the RA4000
Controller, and the Storage Hub, using the appropriate
length of multi-mode Fibre Channel cable. Two GBIC
modules are required for each Fibre channel cable installed.
7.
Apply power to the equipment in the following order:
A. Storage Hubs (accomplished by plugging in A/C
power cord)
B. RA4000
C. Server
The following features apply to the Compaq StorageWorks RAID Array
4000:
Models
Rack-Mountable or Tower
Maximum Number of Drives
Twelve, 1-inch
Eight, 1.6-inch
Hard Drive Interface
Wide-Ultra SCSI-3
Fast-Wide SCSI-2
SCSI ID Select
Automatic
Hubs
Storage Hub 7
Storage Hub 12
GBICs
GBIC-SW, GBIC-LW
Fibre Channel Cable Types
50-micron multimode
62.5-micron multimode
9-micron single mode
Option
Redundant Power Supply
Hot-Pluggable Components
Hard Drives
Fan Assembly
Redundant Power Supplies
Fibre Channel Host Adapters
RA4000 Controllers
Fibre Channel Cable
Status Indicators
Storage System Front Panel
Fan Assembly RA4000 Controller
6
1
2
1
2
3
4
5
3
3