HP StorageWorks MSA 2/8 HP StorageWorks SAN Switch rack mount kit installation - Page 2
About the Plenum, Installation and safety guidelines - san switch
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
About the Plenum The plenum is an air duct that attaches to the switch rails, enabling the switch to draw in cooler air from outside the rack instead of drawing in heated air from inside the rack. The plenum ships with the following switch models only: • SAN Switch 2/8V • SAN Switch 2/8 • SAN Switch 2/16V • 4/8 SAN Switch • 4/16 SAN Switch • 4/32B SAN Switch • 8/8 SAN Switch • 8/24 SAN Switch See "Installing the plenum (if required)" on page 6 for instructions on installing a plenum. Installation and safety guidelines Verify that the rack and the area surrounding the rack meet the following requirements: • Plan a rack space that is 1.5 units high (6.7 cm or 2.6 inches), 48.3 cm (19 inches) wide, and at least 68.6 cm (23 inches) deep. For the MP Router, 4/64 SAN Switch, 8/80 SAN Switch, and Encryption SAN Switch, plan a rack space that is at least 2 units high. • Ground all equipment in the rack through a reliable branch circuit connection, and maintain ground at all times. Do not rely on a secondary connection to a branch circuit, such as a power strip. • Ensure that airflow and temperature requirements are met on an ongoing basis. • Secure the rack to ensure stability in case of unexpected movement. Installing the SAN Switch Rack Mount Kit in an HP custom rack Use the SAN Switch Rack Mount Kit to install your HP device in the following HP custom racks: • HP System/e Rack • HP 10000 Series Rack For optimal cable management, HP recommends that you install the SAN Switch Rack Mount Kit to allow the nonport side of the device to slide out of the cool-air side of the rack. In this installation, the port side of the device is set back from the edge of the rack, allowing a more gradual bend in the fiber optic cables. NOTE: The SAN Switch Rack Mount Kit installation requires one technician. The following items are required to install the device in a rack: • Power cables • #2 Phillips screwdriver • 7/16-inch wrench or socket • Plenum (if required) See "About the Plenum" on page 2 to determine if you need to install a plenum before rack mounting your device. • SAN Switch Rack Mount Kit hardware See Table 1, which identifies the rails and rail-mounting hardware. Depending upon your configuration, one of the following devices may be required: • SAN Switch or MP Router • FCoE Converged Network Switch • Encryption SAN Switch Table 1 SAN Switch Rack Mount Kit hardware Item Description Two rear mounting brackets A right inner rail and a right outer rail A left inner rail and a left outer rail 14 #8-32 x 3/16-inch Phillips panhead screws with thread lock for use with the SAN Switch 2/32 only. 14 #8-32 x 5/16-inch Phillips panhead SEMS screws for use with the 4/8, 4/16, 4/32, 4/64 SAN and 4/32B SAN Switches, and the 2/16, 2/ 8V, 2/16V, MP Router, 400 MP Router, 8/8, 8/24, 8/40, 8/80, and FCoE Converged Network Switch NOTE: All devices require 10 screws except for the 4/32B SAN Switch, MP Router, Encryption SAN Switch, 1606 Extension SAN Switch, and FCoE Converged Network Switch, which require only 6 screws. Ten #10-32 x 1/2-inch Phillips panhead screws with captive star lock washers Eight #10 alignment washers Page 2