HP Surestore Disk Array FC60 Disk Array FC60 User's Guide (A5277A) - Page 161
Frqwuroohuvµ
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 161 highlights
Note Managing the Disk Array on HP-UX Command parameter ArrayID cntrlrID channel:ID LUN Description Identifies the disk array. The ArrayID may be either the disk array ID (its S/N), or an alias name assigned to the array. Each disk array must have a unique ArrayID. The disk array S/N and alias can be determined using the amdsp -i command. Identifies the controller within the disk array controller subsystem. Values can be either A or B, depending on which slot the controller is installed in. Identifies a disk within the disk array. The channel value indicates the SCSI channel that the disk enclosure containing the disk is connected to. The ID value indicates the SCSI ID assigned to the slot in which the disk is installed. Valid channel values are 1 - 6, and valid SCSI ID values are 0 - 4, 8 12. Identifies a specific LUN on the disk array. Valid LUN values are 0 31. 161