If You Can't Start the SETUP Program, If Your Application Software Does Not Work
View all HP Vectra XM 5/xxx manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
4 Troubleshooting Your PC and Using the SETUP Program If Your PC Has a Software Problem If You Can't Start the SETUP Program This may happen if the copy of the PC's configuration stored in memory is corrupted. You will need to erase this bad configuration. To clear the configuration: 1 Switch off the PC and remove the cover (refer to chapter 3). 2 Set the system board switch 3 (CONFG) on the switch block to ON to clear the configuration (refer to page 91 for the switch location). 3 Switch on the PC to erase the memory. 4 Check that error codes 0240 and 0130 are displayed, and wait until the PC has started. 5 Switch off the PC. 6 Set the system board switch 3 (CONFG) on the switch block to OFF to re-enable the configuration. 7 Replace the cover (refer to chapter 3). 8 Switch on the PC and run SETUP by pressing when appears. (Error code 0130 will appear when the PC starts.) 9 Press to save the configuration and exit from SETUP. If Your Application Software Does Not Work If the PC reports the system is OK but some software won't run, and the indicator light over the power switch is illuminated: 1 Check to see if the AUTOEXEC.BAT file is present with the correct settings. Refer to the operating system and application software manuals. 2 If Windows does not run properly, refer to the Windows manual for guidance. 74 English