USER'S GUIDE Ultra320 SCSI to PCI-X Host Adapters July 2003 Version 2.1 ® DB15-000192-01 - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 2
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to it may cause radio interference. Install and use the equipment according to the instruction manual. LSI Logic Asia, Inc. Taiwan Branch 10/F, 156, Min Sheng E. - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 3
Logic products are not intended for use in life-support appliances, devices, or systems. Use of any reference source for all revisions/releases of this product until rescinded by an update. The PCI and PCI-X interface of LSI Logic Corporation. Windows and Windows NT are registered trademarks of - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 4
iv Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved. - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 5
and appendixes: • Chapter 1, Quick Installation Procedures, provides quick instructions for installing your Ultra320 SCSI host adapter and Windows device drivers. • Chapter 2, Detailed Host Adapter Installation, provides detailed instructions for installing your Ultra320 SCSI host adapter. • Chapter - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 6
Logic Corporation, Document number DB14-000176-04 LSI53C1030 PCI to Dual Channel Ultra320 SCSI Multifunction Controller Technical Manual, LSI Logic Corporation, Document number DB14-000156-03 Fusion-MPT™ Device Management User's Guide, LSI Logic Corporation, Document number DB15-000186-01 Revision - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 7
General Description 1.2 Quick Host Adapter Installation 1.3 Quick Windows Driver Installation Chapter 2 Detailed Host Adapter Installation 2.1 Installing Host Adapter Termination 2.4.3 LSI22320 Host Adapter Termination 2.5 Setting SCSI IDs 2.6 Completing the Installation Chapter 3 Ultra320 SCSI - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 8
3.1.2 LSI21320 Dual Channel Host Adapters 3.1.3 LSI22320 Dual Channel Host Adapters 3.2 Host Adapter Characteristics 3.3 Technical Specifications 3.3.1 Electrical Characteristics 3.3.2 Thermal and Atmospheric Characteristics 3.3.3 Safety Characteristics Appendix A Glossary of Terms Customer Feedback - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 9
Figures 2.1 Hardware Connections for the Host Adapter 2.2 Inserting the Host Adapter 2.3 SCSI Cable - 68-pin High Density with Terminator 2.4 SCSI Cable - 68-pin High Density without Terminator 2.5 SCSI Cable - 68-pin VHDCI 2.6 Connecting Internal SCSI Cable to Host Adapter 2.7 Connecting Multiple - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 10
x Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved. - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 11
Controllers and Host Adapters 2.1 SCSI ID Record for Dual Channel Adapter 2.2 Host Adapter Installation Check List 3.1 Ultra320 SCSI, 64-bit, 133 MHz PCI-X Host Adapters 3.2 Host Adapter Characteristics 3.3 Maximum Power Requirements 1-1 2-12 2-13 3-1 3-8 3-9 xi Version 2.1 Copyright © 2002-2003 - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 12
xii Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved. - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 13
computer users. It also provides quick installation instructions for Windows device drivers. This chapter includes these topics: • Section PCI-X computer systems with a standard bracket type. Ultra320 SCSI to PCI-X Host Adapters User's Guide 1-1 Version 2.1 Copyright © 2002-2003 by LSI - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 14
software support includes SureLINK™ Domain Validation on Windows drivers and better performance. To obtain a device driver that supports your operating system, contact the LSI Logic technical support Turn off and unplug the computer. Warning: Be sure to disconnect the computer's power before - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 15
connections secure? • Is the SCSI bus terminated correctly? • Have the SCSI IDs been set and recorded for each device? Step 12. Replace the cabinet cover on your computer. Step 13. Plug in all power cords and turn on power to all devices and your computer. Step 14. Wait for your computer to start up - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 16
8. If you are installing Windows NT 4.0, also install the Service Packs 5 or higher after Windows NT 4.0 has been installed. Note: Refer to the Fusion-MPT™ Device Management User's Guide for detailed configuration and installation instructions for all firmware and drivers. 1-4 Quick Installation - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 17
instructions for installing your host adapter and connecting your SCSI devices to it. The following illustrations show the LSI22320-R Dual Step 1. Turn off and unplug your computer Warning: Be sure to disconnect the computer's power before 's Guide 2-1 Version 2.1 Copyright © 2002-2003 by - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 18
Caution: You must touch a grounded metal surface before handling the host adapter because static charges on your body can damage electronic components. Handle plug-in boards by the edge; do not touch board components or gold connector contacts. LSI Logic recommends that you use a static ground - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 19
2.1.2 Inserting the Host Adapter Perform the following steps to install your Ultra320 SCSI host adapter in the PC mainboard. Step 1. Remove the blank bracket panel on the back of the computer that is aligned with the PCI-X slot you have selected. Save the bracket screw. Step 2. Carefully insert the - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 20
Step 4. Be sure to tighten the bracket screw into the bracket securely before you connect the internal and external SCSI devices. 2.2 SCSI Device Cables For reliable Ultra320 operation, be sure to use an Ultra320 rated SCSI cable. The Ultra320 SCSI cable also has built-in low voltage differential - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 21
2.2.2 External SCSI Cable You can connect all external SCSI devices to the host adapter with shielded cables. You need one 68-pin very high density cable for each device. Figure 2.5 shows an example of an external SCSI cable. Figure 2.5 SCSI Cable - 68-Pin VHDCI SCSI Device Cables Version 2.1 - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 22
Connecting Internal SCSI Devices This section provides step-by-step instructions for connecting internal SCSI devices. The figures show the and two external connectors. Other Ultra320 SCSI host adapter models have different numbers of connectors. Refer to Section 2.2.1, "Internal SCSI Cables," page - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 23
cable to it. Figure 2.7 shows how to do this. You can connect other devices if the cable has more connectors. The Ultra320 SCSI host adapters support up to 15 SCSI devices connected to each SCSI channel. Step 4. Be sure that termination is enabled at the end of the cable that is - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 24
matter as long as all four pins are connected. If the LED does not light during SCSI bus activity from this host adapter, you may have to rotate the the connector on one end or the other of J5. If the LED does not light when there is SCSI activity, move the connector to the other half of J5. 2-8 - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 25
2.3.3 Connecting External SCSI Devices This section provides step-by-step instructions for connecting external SCSI devices. Refer to Section 2.2.2, "External SCSI Cable," page 2-5 for examples of external cables. Step 1. Plug the 68-pin VHDCI connector on - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 26
Step 3. Connect any additional SCSI devices to one another with shielded external SCSI cables. You need a separate SCSI cable for each additional device. Figure 2.10 shows how to connect multiple external SCSI devices. Figure 2.10 Connecting Multiple External SCSI Devices Enable termination on the - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 27
2.4 Terminating the SCSI Bus The SCSI bus contains all the devices that you connect with SCSI cables. When you connect the first and last physical SCSI devices on the ends of the SCSI bus, you must have termination active. You must remove or disable termination on all other SCSI devices on the same - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 28
highest priority to the host adapter. If you plan to boot your computer from a SCSI hard disk drive, you must assign SCSI ID 0 to the drive. Normally, you do not change the host adapter SCSI ID setting from its default value. Typically, you set the SCSI ID of the SCSI device with jumpers or - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 29
items on the checklist, follow these steps: Step 1. Replace the cabinet cover on your computer. Step 2. Plug in all power cords, and turn on power to all devices and your computer. Step 3. Wait for your computer to boot up. Note: To change default configurations of the Ultra320 SCSI host adapters - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 30
2-14 Detailed Host Adapter Installation Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved. - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 31
a number of I/O components to the processor and memory subsystems low profile bracket types. Table 3.1 lists Dual Channel Ultra320 SCSI Standard 6.6 x 4.0 inches, 167.6 x 106.7 mm Dual Channel Ultra320 SCSI Standard 6.6 x 4.0 inches, 167.6 x 106.7 mm Ultra320 SCSI to PCI-X Host Adapters User's Guide - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 32
• LSI Logic Integrated Mirroring™ (IM) technology for boot volume and operating system protection (IM is for the • J5: PCI and PCI-X, 64-bit, universal type board edge connector • J1: 68-pin very high density initialization, the system loads the ID numbers into the Subsystem Vendor ID and Subsystem - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 33
Figure 3.1 illustrates the LSI20320, LSI20320-R, or LSI20320L host adapter. The LSI20320L adapter uses a PCI low profile bracket. Figure 3.2 illustrates the LSI20320H host adapter. Figure 3.1 LSI20320, LSI20320-R and LSI21320L Host Adapters HDR2 Connector for Channel A J3 Channel A Internal SCSI - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 34
-R are dual channel Ultra320 LSI Logic Integrated Mirroring (IM) technology for boot volume and operating system protection (IM is • J1: PCI and PCI-X, 64-bit, universal type board edge connector • J2: 68-pin high density cable , the system loads the ID numbers into the Subsystem Vendor ID and - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 35
J6 for Channels A and B 3.1.3 LSI22320 Dual Channel Host Adapters The LSI Logic LSI22320 and LSI22320-R are dual channel Ultra320 SCSI to PCI-X host adapters /SE termination • LSI Logic Integrated Mirroring (IM) technology for boot volume and operating system protection (IM is for the LSI22320-R - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 36
LSI22320-R host adapters are • J1: PCI and PCI-X, 64-bit, universal type board edge connector • J2 and J3: 68-pin very high density cable • Subsystem ID: 0x1010 During system initialization, the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the embedded SCSI - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 37
Flash Serial LVD/SE Ultra320 SCSI ROM1 EEPROM2 Signaling Data Transfers Yes Yes 16-bit SE or LVD interfaces Up to 320 Mbytes/s as well as Fast, Ultra, Ultra2, and Ultra160 speeds; Synchronous offsets up to 62. 1. For boot code and firmware 2. For BIOS drivers lists the maximum power requirements - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 38
Table 3.3 Maximum Power Requirements Host Adapter LSI20320 LSI20320-R LSI20320-L LSI20320-H LSI21320 LSI21320-R LSI22320 LSI22320-R PCI/PCI-X +5.0 V 1.5 A 1.5 A 5A PCI/PCI-X +3.3 V 2.0 A 2.5 A 0.0 A PCI PRSNT1#/ Over the PRSNT2# Power Operating Range 15 W 0 ˚C to 55 ˚C 15 W 25 W 0 ˚C to 55 - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 39
Usually kept as firmware (ROM based). The system BIOS on the mainboard of a computer is used to boot and control the system. The SCSI BIOS on the host adapter acts as an extension of the system BIOS. Refers to the way a computer is set up; the combined hardware components (computer, monitor, keyboard - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 40
memory. The PCI Local Bus allows transparent upgrades from support SCSI IDs 0 through 7. A device gains ownership of the bus according to the priority of its SCSI ID. The order of priority, from highest to lowest, is: 7, 6, 5, 4, 3, 2, 1, 0, 15, 14, 13, 12, 11, 10, 9. The host adapter is usually set - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 41
SureLINK Ultra SCSI Ultra2 SCSI Ultra160 SCSI Ultra320 SCSI VHDCI The domain validation method developed and used by LSI Logic. SureLINK provides three levels of integrity checking: Basic (level 1), Enhanced (level 2), and Margined (level 3). A standard for SCSI data transfers. It allows a transfer - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 42
A-4 Glossary of Terms Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved. - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 43
shown. If appropriate, please also fax copies of any marked-up pages from this document. Important: Please include your name, phone number, fax number, and company address so that we may contact you directly for clarification or additional information. Thank you for your help in improving the - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 44
: Ultra320 SCSI to PCI-X Host Adapters User's Guide. Place a check mark in the appropriate blank of examples and illustrations Overall manual Excellent Good Average Fair Poor errors in this document, please specify the error and page number. If appropriate, please fax a marked-up copy of - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 45
You can find a current list of our U.S. distributors, international distributors, and sales offices and design resource centers on our web site at http://www.lsilogic.com/contacts/index.html - HP Xw8200 | LSI 20320A-R PCI: Ultra 320 SCSI to PCI-X Host Adapters Users Guide - Page 46
®
Ultra320
SCSI to PCI-X
Host Adapters
DB15-000192-01
USER’S GUIDE
July 2003
Version 2.1