Hitachi CPX400 User Manual - Page 28

To adjust CUSTOM function in GAMMA and COLOR TEMP

Page 28 highlights

PICTURE Menu PICTURE Menu (continued) To adjust CUSTOM function in GAMMA and COLOR TEMP Selecting a mode whose name includes CUSTOM in GAMMA or COLOR TEMP item and then pressing the ► button or ENTER button displays a dialog to aid you in adjusting the mode. Choose an item using the ◄/► buttons, and adjust the level using the ▲/▼ buttons. • When this function is performed, lines or other GAMMA distortion may appear. COLOR TEMP You can display a test pattern on the top of the screen for checking the effect of your adjustment by pressing the ENTER button. Each time you press the ENTER button, the pattern changes as below. No pattern  Gray scale of 9 steps   Ramp  Gray scale of 15 steps test pattern • You can also adjust each function without displaying test patterns. for adjusting GAMMA You can change the brightness of particular tones. The eight equalizing bars correspond to eight tone levels of the test pattern (Gray scale of 9 steps) except the darkest in the left end. If you want to adjust the 2nd tone from left end on the test pattern, use the equalizing adjustment bar "1". The darkest tone at the left end of the test pattern cannot be controlled with any of equalizing adjustment bar. for adjusting COLOR TEMP You can change the intensity of each of 3 colors (Red, Green, Blue). OFFSET adjustments change the color intensity on the whole tones of the test pattern. GAIN adjustments mainly affect color intensity on the brighter tones of the test pattern. 28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

²8
PICTURE Menu
To adjust CUSTOM function in GAMMA and COLOR TEMP
Selecting a mode whose name includes
CUSTOM in GAMMA or COLOR TEMP item
and then pressing the ► button or ENTER
button displays a dialog to aid you in adjusting
the mode.
Choose an item using the ◄/► buttons, and
adjust the level using the ▲/▼ buttons.
• When this function is performed, lines or other
distortion may appear.
You can display a test pattern on the top of the screen for
checking the effect of your adjustment by pressing the ENTER
button. Each time you press the ENTER button, the pattern
changes as below.
No pattern
Gray scale of 9 steps
Ramp
Gray scale of 15 steps
• You can also adjust each function without displaying test patterns.
for adjusting GAMMA
You can change the brightness of particular tones.
The eight equalizing bars correspond to eight tone levels of the test pattern (Gray scale of
9 steps) except the darkest in the left end. If you want to adjust the 2nd tone from left end
on the test pattern, use the equalizing adjustment bar “1”. The darkest tone at the left end
of the test pattern cannot be controlled with any of equalizing adjustment bar.
for adjusting COLOR TEMP
You can change the intensity of each of 3 colors (Red, Green, Blue).
OFFSET adjustments change the color intensity on the whole tones of the test pattern.
GAIN adjustments mainly affect color intensity on the brighter tones of the test pattern.
GAMMA
COLOR TEMP
PICTURE Menu (continued)
test pattern