Holmes HAP8650B Instruction Manual - Page 2

Important Safeguards, Features, Cleaning/maintenance - u filters

Page 2 highlights

IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. These precautions include: 1. Read all instructions before using the appliance. 2. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet. 3. If the filter is covered by a bag when shipped, remove plastic bag before use. 4. Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiators, stoves, or heaters. 5. To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water. 6. Close supervision is necessary when any appliance is used by or near children, or disabled persons. 7. Always unplug the air purifier before moving or cleaning the unit, opening the grill, changing the filters and whenever the unit is not in use. To disconnect the unit, be sure to pull the plug and not the cord. 8. NEVER drop or insert any objects into the openings of the unit. 9. Do not operate any appliance with a damaged cord or plug. If the motor fan fails to operate or the unit has been dropped or damaged in any manner, return appliance to manufacturer for examination and / or repair. 10. Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by Jarden Consumer Solutions may cause hazards. 11. DO NOT use outdoors. 12. NEVER place on a soft surface such as a bed or sofa as this could cause the unit to tip over and block the air inlet or outlet grills. 13. Keep unit away from heated surfaces and open flames. 14. DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so may cause injuries and void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by Jarden Consumer Solutions or an authorized Jarden Consumer Solutions Center. 15. DO NOT place anything on top of unit. 16. Always turn the appliance off before unplugging it. 17. Always turn the appliance off before unplugging it. 18. This appliance should only be used in a room with temperatures between 40° F and 110° F. 19. To reduce the risk of fire or electric shock, DO NOT use this appliance with any solid-state speed control device. SAVE SAFETY INSTRUCTION POWER CORD INSTRUCTIONS • The length of cord used on this appliance was selected to reduce tangling or tripping hazards. • If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the electrical rating of the air purifier (see rating label marked on product). • Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over. THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS SAFETY FEATURE IN ANY WAY. FEATURES GET TO KNOW YOUR AIR PURIFIER Your true HEPA air cleaner removes up to 99.97% of airborne allergens as small as 0.3 microns, such as ragweed pollen, grass pollen, tree pollen, household dust, dust mite debris, mold spores, pet dander and smoke from the air passing through the filter. TRUE HEPA FILTER HEPA (High Efficiency Particulate Air) filters are designed to remove up to 99.97% of airborne pollutants at 0.3 microns or larger, from the air that passes through them. These include tobacco smoke, household dust, pet dander, and pollen. HIGH, MEDIUM, LOW AND SLEEP SPEED SETTINGS For optimum air filtration, operate your Holmes® Air Purifier continuously on the MEDIUM (3) setting. For quieter operation (such as in a bedroom), select LOW (2) or SLEEP (1) setting. When high levels of allergens are present, select the HIGH (4) setting. PRE-OPERATING INSTRUCTIONS NOTE: The door should not be opened when the unit is on its side. 1. After removing the unit from the box, take the plastic covering off the unit and properly dispose of it. 2. Lay the air purifier flat on its back with the front grill pointing up. 3. Open the front grill door of the air purifier by gently pulling it forward. 4. The carbon filters, which are packed in a plastic bag in the box, should be removed from the bag and then placed on each of the pre-installed HEPA filters. The plastic tabs on HEPA filters will hold the carbon filters in place (see Figure 1). 5. Close the front grill door by pushing firmly against the right hand side of the door. Figure. 1 B A. HEPA FILTER B. CARBON FILTER FILTER LIFE MONITOR The Filter Life Monitor uses a series of lights to give you an indication of the remaining filter life. When the filters are new and in good condition, the top light will be illuminated green. As the filter life progresses, the Filter Life Monitor will move to yellow. At this point, the carbon and HEPA filters should be checked. When the Filter Life Monitor light is red, it is time to change the filters. DUAL POSITION The air purifier can stand upright or lie on its side. Also designed to fit with its back flush against the wall. When positioning the unit, please be sure the air inlet grill, filters and air outlet are not blocked to ensure maximum airflow. A OPERATING INSTRUCTIONS IMPORTANT: • Remove all plastic bags from filters before use. • DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL. To operate your air purifier: 1. Select location where air intake grill and filtered air outlet are not obstructed. 2. Plug into a 120V AC electrical outlet. 3. The air purifier is now ready for use. Set the air purifier to the desired speed setting; HIGH (4), MEDIUM (3), LOW (2) or SLEEP (1) by turning the speed control knob. CLEANING/MAINTENANCE Figure. 2 Hang Tabs CLEANING/MAINTENANCE INSTRUCTIONS 1. Turn the air purifier off and unplug it before cleaning. 2. The outside of the air purifier can be cleaned with a soft, clean damp cloth. 3. The filtered air outlet / top air vent can be cleaned of dust with a small, soft brush. 4. If you wish to clean the inside of the air purifier, please remove filters and only use a dry, soft cloth to wipe it down. 5. DO NOT wash filters. WARNING: Do not allow moisture to come in contact with the main housing of the air purifier. Figure. 3 Figure. 4 A B C D A. FILTERED AIR OUTLET B. SPEED CONTROL E KNOB C. FILTER LIFE MONITOR D. RESET BUTTON E. AIR INTAKE GRILL SPEED CONTROL KNOB FILTER LIFE MONITOR RESET BUTTON FILTER REPLACEMENT INSTRUCTIONS IMPORTANT: • NOTE: DO NOT attempt to wash and re-use HEPA filters. • If new filters are enclosed in plastic bags, remove them before use. NOTE: On average, HEPA filters need to be replaced every 12-18 months. Carbon filters need to be replaced every 3-6 months. Filter life will vary depending on air quality and usage. 1. Turn off and unplug the air purifier. 2. For models with the pre-filter (HAP633 & HAP8650), periodically check the condition of the foam pre-filter by opening the front grill door and examining it. Remove any dust or lint from the pre-filter by washing it in warm soapy water. Rinse and drip dry. Replace the pre-filter and secure it with the latch frame on the front grill door. 3. Remove each of the filters from the unit by pulling gently towards you. 4. To replace carbon filters, simply remove the old carbon filter and insert a new carbon in its place, using the plastic tabs as a guideline (see Figure 1). 5. DO NOT attempt to clean the old HEPA filter. To replace HEPA filters, discard the old HEPA filters. Put the carbon filter back on the new HEPA filter. Insert the new HAPF600 HEPA filter into the unit, by sliding it onto the hang tabs. (see Figure 2) 6. Close the front grill door by pushing firmly against the right hand side of the door. 7. After replacing the HEPA filters, RESET the Filter Life Monitor by inserting a small object (such as a pin or paper clip) into the hole below the red filter change light marked RESET and holding it down for 2-3 seconds. HAP8615_HAP8625_HAP8650_HAP633_16EM2.indd 2 11/29/16 9:51 AM

  • 1
  • 2

IMPORTANT SAFEGUARDS
FEATURES
CLEANING/MAINTENANCE INSTRUCTIONS
1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned with a
soft, clean damp cloth.
3. The filtered air outlet / top air vent can be cleaned of
dust with a small, soft brush.
4. If you wish to clean the inside of the air purifier, please
remove filters and only use a dry, soft cloth to wipe it down.
5. DO NOT wash filters.
WARNING:
Do not allow moisture to come in contact
with the main housing of the air purifier.
FILTER REPLACEMENT INSTRUCTIONS
IMPORTANT:
NOTE:
DO NOT attempt to wash and re-use HEPA filters.
• If new filters are enclosed in plastic bags, remove them
before use.
NOTE:
On average, HEPA filters need to be replaced
every 12-18 months. Carbon filters need to be replaced
every 3-6 months. Filter life will vary depending on air
quality and usage.
1. Turn off and unplug the air purifier.
2. For models with the pre-filter (HAP633 & HAP8650),
periodically check the condition of the foam pre-filter by
opening the front grill door and examining it. Remove
any dust or lint from the pre-filter by washing it in warm
soapy water. Rinse and drip dry. Replace the pre-filter
and secure it with the latch frame on the front grill door.
3. Remove each of the filters from the unit by pulling
gently towards you.
4. To replace carbon filters, simply remove the old carbon
filter and insert a new carbon in its place, using the
plastic tabs as a guideline (see Figure 1).
5. DO NOT attempt to clean the old HEPA filter. To
replace
HEPA filters, discard the old HEPA filters. Put the
carbon filter back on the new HEPA filter. Insert the
new HAPF600 HEPA filter into the unit, by sliding it
onto the hang tabs. (see Figure 2)
6. Close the front grill door by pushing firmly against the
right hand side of the door.
7. After replacing the HEPA filters, RESET the Filter Life
Monitor by inserting a small object (such as a pin or
paper clip) into the hole below the red filter change light
marked RESET and holding it down for 2-3 seconds.
GET TO KNOW YOUR AIR PURIFIER
Your true HEPA air cleaner removes up to 99.97% of
airborne allergens as small as 0.3 microns, such as
ragweed pollen, grass pollen, tree pollen, household dust,
dust mite debris, mold spores, pet dander and smoke
from the air passing through the filter.
TRUE HEPA FILTER
HEPA
(High Efficiency Particulate Air) filters are
designed to remove up to 99.97% of airborne pollutants
at 0.3 microns or larger, from the air that passes through
them. These include tobacco smoke, household dust, pet
dander, and pollen.
HIGH, MEDIUM, LOW AND SLEEP SPEED
SETTINGS
For optimum air filtration, operate your Holmes
®
Air
Purifier continuously on the MEDIUM (3) setting. For
quieter operation (such as in a bedroom), select LOW (2)
or SLEEP (1) setting. When high levels of allergens are
present, select the HIGH (4) setting.
FILTER LIFE MONITOR
The Filter Life Monitor uses a series of lights to give you
an indication of the remaining filter life. When the filters
are new and in good condition, the top light will be
illuminated green. As the filter life progresses, the Filter
Life Monitor will move to yellow. At this point, the carbon
and HEPA filters should be checked. When the Filter Life
Monitor light is red, it is time to change the filters.
DUAL POSITION
The air purifier can stand upright or lie on its side. Also
designed to fit with its back flush against the wall. When
positioning the unit, please be sure the air inlet grill,
filters and air outlet are not blocked to ensure maximum
airflow.
PRE-OPERATING INSTRUCTIONS
NOTE: The door should not be opened when the unit is on
its side.
1.
After removing the unit from the box, take the plastic
covering off the unit and properly dispose of it.
2.
Lay the air purifier flat on its back with the front grill
pointing up.
3.
Open the front grill door of the air purifier by gently
pulling it forward.
4.
The carbon filters, which are packed in a plastic bag in
the box, should be removed from the bag and then
placed on each of the pre-installed HEPA filters. The
plastic tabs on HEPA filters will hold the carbon filters
in place (see Figure 1).
5.
Close the front grill door by pushing firmly against the
right hand side of the door.
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons. These precautions include:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance
directly into a 120V AC electrical outlet.
3. If the filter is covered by a bag when shipped,
remove plastic bag before use.
4. Keep the cord out of heavy traffic areas. To avoid
fire hazard, NEVER put the cord under rugs, near
heat registers, radiators, stoves, or heaters.
5. To protect against electrical hazards, DO NOT immerse
in water or other liquids. Do not use near water.
6. Close supervision is necessary when any appliance is
used by or near children, or disabled persons.
7. Always unplug the air purifier before moving or
cleaning the unit, opening the grill, changing the filters
and whenever the unit is not in use. To disconnect the
unit, be sure to pull the plug and not the cord.
8. NEVER drop or insert any objects into the openings of
the unit.
9. Do not operate any appliance with a damaged cord
or plug. If the motor fan fails to operate or the unit
has been dropped or damaged in any manner, return
appliance to manufacturer for examination and / or
repair.
10. Use appliance only for intended household use as
described in this manual. Any other use not
recommended by the manufacturer may cause fire,
electric shock, or injury to persons. The use of
attachments not recommended or sold by Jarden
Consumer Solutions may cause hazards.
11. DO NOT use outdoors.
12. NEVER place on a soft surface such as a bed or sofa
as this could cause the unit to tip over and block the
air inlet or outlet grills.
13. Keep unit away from heated surfaces and open flames.
14. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so may cause
injuries and void your warranty. The inside of the unit
contains no user serviceable parts. All servicing should
be performed by Jarden Consumer Solutions or an
authorized Jarden Consumer Solutions Center.
15. DO NOT place anything on top of unit.
16. Always turn the appliance off before unplugging it.
17. Always turn the appliance off before unplugging it.
18. This appliance should only be used in a room with
temperatures between 40° F and 110° F.
19. To reduce the risk of fire or electric shock, DO NOT
use this appliance with any solid-state speed control
device.
SAVE SAFETY
INSTRUCTION
POWER CORD INSTRUCTIONS
The length of cord used on this appliance was
selected to reduce tangling or tripping hazards.
If a longer cord is necessary, an approved extension
cord may be used. The electrical rating of the
extension cord must be equal to or greater than the
electrical rating of the air purifier (see rating label
marked on product).
Care must be taken to arrange the extension cord so
that it will not drape over the countertop or tabletop
where it can be pulled on by children or accidentally
tripped over.
CLEANING/MAINTENANCE
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to
install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
Figure. 1
Figure. 2
Figure. 3
Figure. 4
A
A. HEPA FILTER
B. CARBON FILTER
Hang Tabs
A
B
C
D
E
A. FILTERED AIR OUTLET
B. SPEED CONTROL
KNOB
C. FILTER LIFE MONITOR
D. RESET BUTTON
E. AIR INTAKE GRILL
SPEED CONTROL
KNOB
FILTER LIFE
MONITOR
RESET BUTTON
B
OPERATING INSTRUCTIONS
IMPORTANT:
• Remove all plastic bags from filters before use.
• DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL.
To operate your air purifier:
1. Select location where air intake grill and filtered air
outlet are not obstructed.
2. Plug into a 120V AC electrical outlet.
3. The air purifier is now ready for use. Set the air
purifier to the desired speed setting; HIGH (4),
MEDIUM (3), LOW (2) or SLEEP (1) by turning the
speed control knob.
HAP8615_HAP8625_HAP8650_HAP633_16EM2.indd
2
11/29/16
9:51 AM