Holmes HM7600 Instruction Manual - Page 2

Please Read And Save, These Important, Safety Instructions

Page 2 highlights

HM760007EM1.qxd 6/2/07 15:02 Page 2 PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS Thank you for purchasing this Holmes® product. We understand the value of quality and are committed to making superior products that stand the test of time. We trust this product will exceed your expectations of quality and reliability. We hope that you enjoy this product and will consider purchasing another Holmes® product in the future. To see our full product line or if you have any questions or comments about this product, please visit our website at: www.holmesproducts.com. When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before using the appliance. 2. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet. 3. Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers. 4. DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. DO locate your humidifier on an inside wall near an electrical outlet. The humidifier should be at least 4" away from the wall for best results. 5. NEVER place humidifier in an area where it is accessible to children. NEVER use humidifier in a closed room, particularly where a child may be sleeping, resting, or playing (a closed room may result in excessive humidity). 6. WARNING: Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet. Failure to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord. 7. Never place anything over moisture outlet when the unit is running. 8. NEVER drop or insert any object into any openings. 9. DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair. 10.Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by the manufacturer may cause hazards. 11.DO NOT use outdoors. 12. Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture. 13.DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wall paper. 14.Humidifier should be unplugged when not in use. 15.NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit. 16.This humidifier requires daily and weekly maintenance to operate appropriately. Refer to daily and weekly cleaning procedures. Use only cleaners and additives recommended by the manufacturer. THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS SAFETY FEATURE IN ANY WAY. PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS 17. NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier. 18.Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF. 19.Do not use humidifier in an area where humidity level is in excess of 50%. Use a hygrometer, available at your local retailer or through the manufacturer, to measure the humidity. 20.DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only. 21.Never place housing under water flow or immerse in liquids. 22.Do not plug in the cord with wet hands: electric shock could result. 23.Do not pour water in any openings other than the water tank. 24. To prevent damage to surfaces, do not place humidifier under overhanging surfaces. 25.NEVER operate unit without water in the tank. 26.Do not move unit after it has been used until unit cools completely. 27.Use both hands when carrying full tank of water. PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS Consumer Safety Information NOTE: This is an electrical appliance and requires attention when in use. NOTE: If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage. NOTE: DO NOT block air inlet or outlet. Cord and Plug Installation Safety Instructions The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier. Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over. HOW COOL MIST WORKS Your Holmes® Cool Mist humidifier draws dry air through the rear air intake grill area. This air is then passed through a moisture-laden wick filter, which retains the minerals and deposits in the water. The resulting moist air is directed back into the room from the top air grill. NOTE: This humidification system provides a cool, invisible moisture output. It is normal not to see the mist. NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%. PRE-OPERATING INSTRUCTIONS 1. Be sure the humidifier is switched off. 2. Select a location for your humidifier, on a flat level surface about 4" away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by too much moisture or water. Place on a moisture resistant surface. OPERATING INSTRUCTIONS 1. Remove the tank and the main housing. 2. Make sure the wick is in place. 3. Bring the tank to the sink, turn upside down and twist off the tank cap by turning counter clockwise. Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank FIRMLY. The tank will hold 1 gallon of water. 4. Replace the top housing and tank. The tank will immediately begin to empty into the base. 5. Plug the humidifier into a 120V electrical outlet. FEATURES - OPERATIONS CLEANING/MAINTENANCE 6. To turn the unit on, switch the knob to either the High (III), Med (II) or Low (I) setting. High will produce the maximum moisture and Low will produce the longest run time and quieter performance. 7. To turn the unit off, switch the knob to Off (O). Manual Humidistat Operation: 1. Adjust the Humidity Control Knob and the Humidistat as desired. 2. The Automatic Humidistat Control is designed to operate between 25% and 60% Relative Humidity range. The recommended setting is between 40% and 50%. When the humidity level in the room is below the level you have set, the humidifier will operate to produce moisture. When the set humidity level in the room is reached, the humidifier will stop. When the humidity again drops below the set level, the unit will automatically start and produce moisture again. NOTE: If moisture forms on the walls or windows, turn off the humidifier. REMOVING PERMANENT FILTER FOR CLEANING Through normal use, waterborne minerals and sediment become trapped in the wick filter. The harder your water, the greater the amount of minerals in the water, and the more often you will need to wash your filter. Figure 1 A B C G H A. Water Tank ED B. 3 Speed Fan Control C. Manual Humidistat Control D. Exhaust Grill E. FilterCleanTM Indicator F. Air Intake Grill G. Humidifier Base F H. Humidifier Housing You will be able to monitor the life of the filter in your humidifier by checking the FilterCleanTM Indicator. When the unit is off, the FilterCleanTM Indicator will read in the OFF position. After 60 minutes of use, FilterCleanTM Indicator (refer to Figure 2 for close-up of indicator) will move from the OFF position and indicate your filter condition. A brand new filter will Figure 2 register in the blue section reading GOOD filter. After frequent use of your humidifier, the FilterCleanTM Indicator will let you know when the filter needs to be washed. When the needle is in the red (Wash Filter) section, this means the proper amount of moisture is not getting into your air due to the excessive minerals and sediment that have become trapped on your filter. At this point, you should wash your filter. It is important to wash your filter as indicated to obtain stated performance level. To remove filter for cleaning follow the steps below: 1. Turn the unit off and disconnect from the electrical outlet. 2. Remove the tank and main housing to access the base tray. 3. Remove the filter and follow the filter and weekly cleaning procedure. 4. Insert the refreshed filter. 5. Repeat Operating Instructions. It will take about 30 minutes for the humidifier to reach maximum output. You can purchase replacement filters (model HWF65P (Part Number 7400001000425)) at your local retailer, by calling 1-800-546-5637, filling out the accessory card, or by visiting www.holmesproducts.com. It is recommended that a replacement filter is purchased for uninterrupted use. CLEANING AND MAINTENANCE INSTRUCTIONS Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use. In addition, if you do not follow the recommended care and CLEANING/MAINTENANCE STORAGE INSTRUCTIONS maintenance guidelines, micro-organisms may be able to grow in the water within the water tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up. Filter Washing Procedure: 1. The water tray should be cleaned when you clean the filter. The water tray is a convenient way to carry the filter to prevent dripping. 2. Mix 1 gallon warm tap water with 1 teaspoon concentrated antibacterial liquid dish washing soap. 3. Fully submerge filter in soap solution for 15-20 minutes. 4. Dunk filter in soap solution several times then gently press to release the soapy water. Be sure not to wring, pull or scrub filter as this will degrade the filter. 5. Run under cool tap water until there is no soap remaining. Some discoloration may still be visible, this is normal and does not affect performance. 6. Gently shake or press the filter to remove excess water. 7. The filter can be put directly into the humidifier while still damp if it is to be used right away, or allow filter to dry completely if humidifier is to be stored. Should your filter become damaged or lost, please call the customer service number listed in the manual for a replacement part. The part number for this filter is: HWF65P (Part Number 7400001000425). Daily Maintenance: 1. Be sure the unit is OFF and is disconnected from the electrical outlet. 2. Remove the housing and the tank from the humidifier and place in sink or tub. 3. Carry the base of the unit to the sink, remove the wick, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean, and dry with a clean cloth or paper towel. 4. Drain the water from the tank into the sink and rinse tank thoroughly. Wipe clean, and dry with a clean cloth or paper towel. 5. Put filter back in, replace the housing, then refill tank with cool tap water as instructed earlier in the Filling Instructions. DO NOT overfill. 6. Follow Operating Instructions. Weekly Maintenance: To Remove Scale: 1. Repeat steps 1-4 above. 2. Clean the base by partially filling the base with one 8-oz cups of undiluted white vinegar, or by using CleanseCleanTM (Model S1710) by the manufacturer. Leave this solution in the base for 20 minutes, while cleaning all the interior surfaces with a soft brush. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar. 3. Rinse with clean warm water to remove the cleaning solution before disinfecting the tank. To Disinfect Humidifier Base and Tank: 1. Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Carefully empty the tank after 20 minutes, and rinse with warm water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel. 4. Place filter back into tank an refill the water tank as directed in Operating Instructions, and turn the unit on. STORAGE INSTRUCTIONS If your humidifier will not be in use for two days or more, or at the end of the season follow these instructions. 1. Clean and dry the humidifier thoroughly as per the "Weekly Maintenance" instructions. 2. Let the humidifier dry completely before storing. Do not store with water inside the base or water tank. 3. Remove the tank cap. Do not store with the tank cap in place. 4. Follow Filter Washing Procedure before storage. Ensure that the filter is completely dry before being stored. 5. Store in a cool dry location.

  • 1
  • 2

17.NEVER use detergents, gasoline, glass cleaner, furniture
polish, paint thinner, or other household solvents to
clean any part of the humidifier.
18.Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
19.Do not use humidifier in an area where humidity level
is in excess of 50%. Use a hygrometer, available at
your local retailer or through the manufacturer, to
measure the humidity.
20.DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed by
qualified personnel only.
21.Never place housing under water flow or immerse in
liquids.
22.Do not plug in the cord with wet hands: electric shock
could result.
23.Do not pour water in any openings other than the
water tank.
24.To prevent damage to surfaces, do not place humidifier
under overhanging surfaces.
25.NEVER operate unit without water in the tank.
26.Do not move unit after it has been used until unit cools
completely.
27.Use both hands when carrying full tank of water.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
Consumer Safety Information
NOTE:
This is an electrical appliance and requires
attention when in use.
NOTE:
If moisture forms on the walls or windows of the
room, turn off the humidifier. The room already has plenty
of humidity and additional moisture may cause damage.
NOTE:
DO NOT block air inlet or outlet.
Cord and Plug Installation Safety Instructions
The length of cord used on this appliance was selected to
reduce the hazards of becoming tangled in, or tripping over a
longer cord. If a longer cord is necessary, an approved extension
cord may be used. The electrical rating of the extension cord must
be equal to or greater than the rating of the humidifier.
Care must be taken to arrange the extension cord so that
it will not drape over the countertop or tabletop where it
can be pulled on by children or accidentally tripped over.
HOW COOL MIST WORKS
Your Holmes
®
Cool Mist humidifier draws dry air through
the rear air intake grill area. This air is then passed
through a moisture–laden wick filter, which retains the
minerals and deposits in the water. The resulting moist air
is directed back into the room from the top air grill.
NOTE:
This humidification system provides a cool, invisible
moisture output. It is normal not to see the mist.
NOTE:
A humidity level below 20% can be unhealthy and
uncomfortable. The recommended humidity level is
between 40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched off.
2. Select a location for your humidifier, on a flat level
surface about 4” away from the wall. DO NOT place the
humidifier on a finished floor or near furniture, which
can be damaged by too much moisture or water. Place
on a moisture resistant surface.
OPERATING INSTRUCTIONS
1. Remove the tank and the main housing.
2. Make sure the wick is in place.
3.
Bring the tank to the sink, turn upside down and twist off
the tank cap by turning counter clockwise. Fill tank with
cool, fresh tap water. DO NOT fill with warm water as this
may cause leaking. Replace the cap on tank FIRMLY. The
tank will hold 1 gallon of water.
4.
Replace the top housing and tank. The tank will immediately
begin to empty into the base.
5. Plug the humidifier into a 120V electrical outlet.
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
CLEANING/MAINTENANCE
STORAGE INSTRUCTIONS
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
Thank you for purchasing this Holmes
®
product. We
understand the value of quality and are committed to
making superior products that stand the test of time. We
trust this product will exceed your expectations of quality
and reliability. We hope that you enjoy this product and will
consider purchasing another Holmes
®
product in the
future. To see our full product line or if you have any
questions or comments about this product, please visit our
website at: www.holmesproducts.com.
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
1.
Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance
directly into a 120V AC electrical outlet.
3.
Keep the cord out of heavy traffic areas. To avoid fire
hazard, NEVER put the cord under rugs or near heat
registers.
4. DO NOT place humidifier near heat sources such as
stoves, radiators, and heaters. DO locate your
humidifier on an inside wall near an electrical outlet.
The humidifier should be at least 4” away from the wall
for best results.
5.
NEVER place humidifier in an area where it is accessible
to children. NEVER use humidifier in a closed room,
particularly where a child may be sleeping, resting, or
playing (a closed room may result in excessive
humidity).
6.
WARNING: Do not attempt to refill humidifier without
first unplugging the unit from its electrical outlet.
Failure to heed this warning may cause personal injury.
Be sure to unplug the unit by pulling on the plug and
not the cord.
7.
Never place anything over moisture outlet when the
unit is running.
8.
NEVER drop or insert any object into any openings.
9.
DO NOT operate any appliance with a damaged cord or
plug, after the appliance malfunctions, or if it has been
dropped or damaged in any manner.
Return appliance
to manufacturer for examination, electrical or
mechanical adjustment, or repair.
10.Use appliance only for intended household use as
described in this manual. Any other use not
recommended by the manufacturer may cause fire,
electric shock, or injury to persons. The use of
attachments not recommended or sold by the
manufacturer may cause hazards.
11.DO NOT use outdoors.
12.Always place humidifier on a firm, flat, level surface.
A
waterproof mat or pad is recommended for use under
the humidifier. NEVER place it on a rug or carpet, or on
a finished floor that may be damaged by exposure to
water or moisture.
13.DO NOT allow the Moisture Outlet to directly face the
wall. Moisture could cause damage, particularly to wall
paper.
14.Humidifier should be unplugged when not in use.
15.NEVER tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit.
16.This humidifier requires daily and weekly maintenance
to operate appropriately. Refer to daily and weekly
cleaning procedures. Use only cleaners and additives
recommended by the manufacturer.
maintenance guidelines, micro-organisms may be able to
grow in the water within the water tank. You must routinely
follow the cleaning procedures that follow in order to ensure
proper, efficient operation of your humidifier. Proper
maintenance and cleaning is essential to the continued
performance of your unit and the avoidance of algae or bacteria
build-up.
Filter Washing Procedure:
1. The water tray should be cleaned when you clean the filter.
The water tray is a convenient way to carry the filter to
prevent dripping.
2.
Mix 1 gallon warm tap water with 1 teaspoon concentrated
antibacterial liquid dish washing soap.
3.
Fully submerge filter in soap solution for 15-20 minutes.
4. Dunk filter in soap solution several times then gently press
to release the soapy water.
Be sure not to wring, pull or
scrub filter as this will degrade the filter.
5. Run under cool tap water until there is no soap remaining.
Some discoloration may still be visible, this is normal and
does not affect performance.
6.
Gently shake or press the filter to remove excess water.
7. The filter can be put directly into the humidifier while still
damp if it is to be used right away, or allow filter to dry
completely if humidifier is to be stored.
Should your filter become damaged or lost, please call the
customer service number listed in the manual for a replacement
part. The part number for this filter is: HWF65P (Part Number
7400001000425).
Daily Maintenance:
1. Be sure the unit is OFF and is disconnected from the
electrical outlet.
2. Remove the housing and the tank from the humidifier
and place in sink or tub.
3. Carry the base of the unit to the sink, remove the wick,
place in sink, drain any remaining water and rinse
thoroughly to remove any sediment or dirt. Wipe clean,
and dry with a clean cloth or paper towel.
4.
Drain the water from the tank into the sink and rinse tank
thoroughly. Wipe clean, and dry with a clean cloth or
paper towel.
5.
Put filter back in, replace the housing, then refill tank with
cool tap water as instructed earlier in the Filling
Instructions. DO NOT overfill.
6. Follow Operating Instructions.
Weekly Maintenance:
To Remove Scale:
1.
Repeat steps 1-4 above.
2.
Clean the base by partially filling the base with one 8-oz
cups of undiluted white vinegar, or by using
CleanseClean
TM
(Model S1710) by the manufacturer.
Leave this solution in the base for 20 minutes, while
cleaning all the interior surfaces with a soft brush.
Remove base scale by wiping the base with a cloth
dampened with undiluted white vinegar.
3. Rinse with clean warm water to remove the cleaning
solution before disinfecting the tank.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier tank 1/2 full with water and 1/2
tablespoon of chlorine bleach.
2.
Let the solution stand for 20 minutes, swishing every few
minutes. Wet all surfaces.
3.
Carefully empty the tank after 20 minutes, and rinse with
warm water until you cannot detect any bleach smell. Dry
with a clean cloth or paper towel.
4. Place filter back into tank an refill the water tank as
directed in Operating Instructions, and turn the unit on.
STORAGE INSTRUCTIONS
If your humidifier will not be in use for two days or more,
or at the end of the season follow these instructions.
1.
Clean and dry the humidifier thoroughly as per the
“Weekly Maintenance” instructions.
2.
Let the humidifier dry completely before storing. Do
not store with water inside the base or water tank.
3.
Remove the tank cap. Do not store with the tank cap
in place.
4.
Follow Filter Washing Procedure before storage.
Ensure that the filter is completely dry before being
stored.
5.
Store in a cool dry location.
6.
To turn the unit on, switch the knob to either the High (III), Med
(II) or Low (I) setting.
High will produce the maximum
moisture and Low will produce the longest run time and quieter
performance.
7. To turn the unit off, switch the knob to Off (O).
Manual Humidistat Operation:
1. Adjust the Humidity Control Knob and the Humidistat as
desired.
2.
The Automatic Humidistat Control is designed to operate
between 25% and 60% Relative Humidity range. The
recommended setting is between 40% and 50%. When
the humidity level in the room is below the level you have
set, the humidifier will operate to produce moisture.
When the set humidity level in the room is reached, the
humidifier will stop. When the humidity again drops
below the set level, the unit will automatically start and
produce moisture again.
NOTE:
If moisture forms on the walls or windows, turn
off the humidifier.
REMOVING PERMANENT FILTER
FOR CLEANING
Through normal use, waterborne minerals and sediment
become trapped in the wick filter. The harder your water,
the greater the amount of minerals in the water, and the
more often you will need to wash your filter.
You will be able to monitor the life of the filter in your
humidifier by checking the FilterClean
TM
Indicator. When the
unit is off, the FilterClean
TM
Indicator will read in the OFF
position. After 60 minutes of use, FilterClean
TM
Indicator (refer
to Figure 2 for close-up of indicator) will move from the OFF
position and indicate your filter
condition. A brand new filter will
register in the blue section reading
GOOD filter.
After frequent use of
your humidifier, the FilterClean
TM
Indicator will let you know when
the filter needs to be washed.
When the needle is in the red (Wash Filter) section, this means
the proper amount of moisture is not getting into your air due
to the excessive minerals and sediment that have become
trapped on your filter. At this point, you should wash your filter.
It is important to wash your filter as indicated to obtain stated
performance level.
To remove filter for cleaning follow the steps
below:
1.
Turn the unit off and disconnect from the electrical outlet.
2.
Remove the tank and main housing to access the base tray.
3.
Remove the filter and follow the filter and weekly cleaning
procedure.
4.
Insert the refreshed filter.
5.
Repeat Operating Instructions.
It will take about 30 minutes for the humidifier to reach
maximum output.
You can purchase replacement filters (model HWF65P (Part
Number 7400001000425)) at your local retailer, by calling
1-800-546-5637, filling out the accessory card, or by visiting
www.holmesproducts.com. It is recommended that a
replacement filter is purchased for uninterrupted use.
CLEANING AND MAINTENANCE
INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry, heated
indoor air. To benefit most from the humidifier and avoid
product misuse, follow all instructions carefully. Please note that
this is an electrical appliance and requires attention when in use.
In addition, if you do not follow the recommended care and
Figure 2
FEATURES - OPERATIONS
CLEANING/MAINTENANCE
A.
Water Tank
B.
3 Speed Fan
Control
C.
Manual Humidistat
Control
D.
Exhaust Grill
E. FilterClean
TM
Indicator
F.
Air Intake Grill
G.
Humidifier Base
H.
Humidifier Housing
A
B
C
D
E
Figure 1
G
H
F
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in
a polarized outlet only one way. If the plug does not fit fully in the
outlet, reverse the plug. If it still does not fit, contact a qualified
electrician to install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
HM760007EM1.qxd
6/2/07
15:02
Page 2