N8788V1 5/99 Rev. B ADEMCO 5814 DOOR/WINDOW TRANSMITTER INSTALLATION INSTRUCTIONS Use the 5814 Door/Window Transmitter only with alarm systems that support 5800 series wireless devices. The transmitter has its own unique serial number permanently assigned during manufacture, which must be entered into the control panel prior to the transmitterÕs usage. Refer to the control unit's installation instructions for programming details. Note: During programming of the control unit, 5814 transmitters should be treated as "RF" (i.e. supervised RF) Type (mandatory for UL installations ). The 5814 is assigned one zone. MOUNTING The unit is generally mounted as shown in the diagram, with the magnet located to the unit's right. However, it can be installed in any position, as long as the relationship of the unit to the magnet is maintained. Before mounting the transmitter permanently, conduct Go/No Go tests (see control's instructions) to verify adequate signal strength from the mounting location. 1. Mount using double -faced tape (supplied) by affixing it to the back of the unit and mounting the unit in place. Warning: Do not mount unit in a location where temperature my approach freezing point (32°F). 2. Mount the magnet (supplied) adjacent to the alignment mark on the unitÕs case (see Diagram). BATTERY (+SIDE UP) PC BOARD COVER PRY OFF POINT « 1/2" MAX SPACING REED SWITCH ON UNDERSIDE OF PC BOARD (IN UNIT) MAGNET 5814 WITH BACK COVER OFF q SLOYCMABTOIOL NONOFSIRDEEEODFSGFCWOUARIISTDECMEHASMGHANOREWKTS FCC STATEMENT FCC ID: ÊCFS8DL5814 This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:ÊÊ(1) This device may not cause harmful interference, and (2) must accept any interference received, including interference that may cause undesired operation. SPECIFICATIONS Unit Dimensions: 1-1/2Ó (37mm) x 1-3/16Ó (30mm) x 5/8Ó (15mm) Battery: Duracell DL2430 or Renata/Sanyo/Varta CR2430 REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION, AND DETAILS REGARDING THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 165 Eileen Way, Syosset, New York 11791 Copyright © 2004 Honeywell International Inc. www.honeywell.com/security àN8788V1Üä N8788V1 5/99 Rev. B

  • 1

DOOR/WINDOW
TRANSMITTER
INSTALLATION INSTRUCTIONS
Use the 5814 Door/Window Transmitter only with
alarm systems that support 5800 series wireless
devices. The transmitter has its own unique serial
number permanently assigned during manufacture,
which must be entered into the control panel prior to
the transmitter°s usage. Refer to the control unit’s
installation instructions for programming details.
Note:
During programming of the control unit, 5814
transmitters should be treated as "RF" (i.e. supervised
RF) Type (
mandatory for UL installations
). The 5814 is
assigned one
zone.
MOUNTING
The unit is generally mounted as shown in the
diagram, with the magnet located to the unit’s right.
However, it can be installed in
any
position, as long as
the relationship of the unit to the magnet is
maintained.
Before mounting the transmitter permanently, conduct
Go/No Go tests (see control’s instructions) to verify
adequate signal strength from the mounting location.
1.
Mount using double
-
faced tape
(supplied) by
affixing it to the back of the unit and mounting the
unit in place.
Warning:
Do not mount unit in a location
where temperature my approach freezing point
(32
°
F).
2.
Mount the magnet
(supplied) adjacent to the
alignment mark on the unit°s case (see Diagram).
MAGNET
COVER PRY
OFF POINT
1/2” MAX
SPACING
«
5814 WITH BACK
COVER OFF
BATTERY
(
+
SIDE UP)
PC BOARD
REED SWITCH
ON UNDERSIDE
OF PC BOARD
(IN UNIT)
SYMBOL ON SIDE OF CASE SHOWS
LOCATION OF REED SWITCH
q
FCC STATEMENT
FCC ID: CFS8DL5814
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions: (1) This
device may not cause harmful interference, and (2) must
accept any interference received, including interference that
may cause undesired operation.
SPECIFICATIONS
Unit Dimensions
:
1-1/2± (37mm) x 1-3/16± (30mm) x 5/8± (15mm)
Battery:
Duracell DL2430 or Renata/Sanyo/Varta
CR2430
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE
RECEIVER/CONTROL WITH WHICH THIS DEVICE IS
USED FOR WARRANTY INFORMATION, AND DETAILS
REGARDING THE LIMITATIONS OF THE ENTIRE ALARM
SYSTEM.
àN8788V1Üä
N8788V1
5/99
Rev. B
N8788V1
5/99
Rev. B
ADEMCO 5814
165 Eileen Way, Syosset, New York 11791
Copyright
© 2004 Honeywell International Inc.
www.honeywell.com/security