STEP 8. CUSTOMIZE THE THERMOSTAT Set Fuel Switch (CT8775C Only) ❑ To adjust the fuel switch, locate the switch labeled E/F on the wallplate (see Fig. 3). The fuel switch is factory set in the F position. This is the correct setting for gas or oil systems. If you have an electric heat system, or a heat pump, set the switch to E. The E setting allows the fan to turn on immediately with the heating system where the G terminal is connected. DIP Switch ❑ To adjust the heat cycle rate or the Fahrenheit/Celsius indication, locate DIP switch 1, 2 and 3 on the back of the thermostat. See Fig. 4. Set Heat Cycle Rate ❑ Use DIP switches 1 and 2 to set the heat cycle rate. See Table 3. NOTE: The CT8775A,C Thermostats will provide optimal temperature control if DIP switches 1 and 2 are set according to your particular heating system. FUEL SWITCH M19497 Fig. 3. Fuel switch. BACK OF THERMOSTAT ON 123 69-1676-1 DIP SWITCH M19567 Fig. 4. DIP switch. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

69-1676±1
10
STEP 8. CUSTOMIZE THE THERMOSTAT
Set Fuel Switch (CT8775C Only)
To adjust the fuel switch, locate the switch labeled E/F on the wallplate
(see Fig. 3). The fuel switch is factory set in the F position. This is the
correct setting for gas or oil systems. If you have an electric heat
system, or a heat pump, set the switch to E. The E setting allows the
fan to turn on immediately with the heating system where the G
terminal is connected.
DIP Switch
To adjust the heat cycle rate or the Fahrenheit/Celsius indication,
locate DIP switch 1, 2 and 3 on the back of the thermostat. See Fig. 4.
Set Heat Cycle Rate
Use DIP switches 1 and 2 to set the heat cycle rate. See Table 3.
NOTE:
The CT8775A,C Thermostats will provide optimal temperature
control if DIP switches 1 and 2 are set according to your partic-
ular heating system.
Fig. 3. Fuel switch.
Fig. 4. DIP switch.
M19497
FUEL SWITCH
ON
1
2
3
M19567
BACK OF THERMOSTAT
DIP SWITCH