Honeywell HE360A Owners Guide - Page 3

Operating Your Humidifier, HE360A, How Your Humidifier Works - installation

Page 3 highlights

HE360A POWERED FLOW-THROUGH HUMIDIFIER OPERATING YOUR HUMIDIFIER HE360A Your HE360A Humidifier is controlled by the H8908 Humidistat. The humidistat is installed either on an interior wall in the living area, or on the return air duct. Choose the humidity control setting using the combination relative humidity/outdoor temperature setting scale on your humidity control dial. Match the dial setting to the outdoor temperature for optimizing the humidity level while reducing the moisture condensation on your windows. The table below can also be used to adjust the humidity control to the recommended setting. At Outside Temperature -20°F (-30°C) -10°F (-25°C) 0°F (-20°C) +10°F (-10°C) +20°F (-5°C) Above 20° (Above 0°C) Recommended Control Setting 15 20 25 30 35 40 M20838 HOW YOUR HUMIDIFIER WORKS Your humidifier uses the principle that vapor (evaporated water) is created when warm air blows over a water-soaked area. As the vapor circulates, the relative humidity rises. Your humidity control monitors the relative humidity and activates the humidifier accordingly. The humidifier has a water supply that dispenses water evenly over a humidifier pad. The warm dry air, from the furnace, passes over the humidifier pad and picks up the moist air to circulate it throughout your home. Humidified air feels warmer and more comfortable so you may be able to lower your thermostat heating setpoint, which saves money on your heating fuel bills. The end result is that your humidifier gives you a comfortable environment that is also energy efficient. 3 69-1656

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

HE360A POWERED FLOW-THROUGH HUMIDIFIER
3
69-1656
OPERATING YOUR HUMIDIFIER
HE360A
Your HE360A Humidifier is controlled by the H8908 Humidistat. The humidistat is
installed either on an interior wall in the living area, or on the return air duct. Choose
the humidity control setting using the combination relative humidity/outdoor
temperature setting scale on your humidity control dial. Match the dial setting to the
outdoor temperature for optimizing the humidity level while reducing the moisture
condensation on your windows. The table below can also be used to adjust the
humidity control to the recommended setting.
HOW YOUR HUMIDIFIER WORKS
Your humidifier uses the principle that vapor (evaporated water) is created when warm
air blows over a water-soaked area. As the vapor circulates, the relative humidity rises.
Your humidity control monitors the relative humidity and activates the humidifier
accordingly. The humidifier has a water supply that dispenses water evenly over a
humidifier pad. The warm dry air, from the furnace, passes over the humidifier pad and
picks up the moist air to circulate it throughout your home.
Humidified air feels warmer and more comfortable so you may be able to lower your
thermostat heating setpoint, which saves money on your heating fuel bills. The end
result is that your humidifier gives you a comfortable environment that is also energy
efficient.
At Outside Temperature
Recommended
Control Setting
-20³F (-30³C)
15
-10³F (-25³C)
20
0³F (-20³C)
25
+10³F (-10³C)
30
+20³F (-5³C)
35
Above 20³ (Above 0³C)
40
M20838