Honeywell YRTH7500D1009 Quick Start Guide

Honeywell YRTH7500D1009 - 5 Day Program Thermostat Manual

Honeywell YRTH7500D1009 manual content summary:

  • Honeywell YRTH7500D1009 | Quick Start Guide - Page 1
    and where to properly and safely dispose of your old thermostat. CAUTION: To avoid possible compressor damage, do not run air conditioner if the outside temperature drops below 50°F (10°C). Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422
  • Honeywell YRTH7500D1009 | Quick Start Guide - Page 2
    thermostat controls fan operation). 12b Preferences (optional) Use the Setup and Navigation steps in 12a to set Display Preferences. Function Settings & Options 0300 Manual/Auto Changeover 0 Manual use the new 2007 DST calendar). 0500 Furnace Filter Change 0 Off (no reminder) Reminder 1
  • 1
  • 2

MCR33842
Go Back
Next
Done
6
15
2012
MCR33763
50
60
70
80
F
OFF
AUTO
EM. HEAT
EM. HEAT
AUX. HEAT
50 60
70
80
MCR33835
Installation is Easy
Label wires and remove your old thermostat
Install and wire your new thermostat
Set your new thermostat to match your heating/cooling
system
This thermostat works with virtually all System
Types
It is preset for the most common system
We are here to help.
Call 1-800-468-1502 for
wiring assistance before
returning the thermostat to
the store.
Remove old thermostat but leave wallplate with
wires attached.
2
Remove Old Thermostat
1
Turn
OFF
Power to Heating/
Cooling System
Is there a sealed tube containing
mercury? If so, see back cover for
proper disposal instructions.
Leave wallplate in
place
Old thermostat
Cover
Label the wires using the supplied wire labels as you
disconnect them, then remove the old wallplate.
3
Label Wires with Tags
Wire Labels
Wire color might not match labels.
M31545
Remove wallplate from the new thermostat.
M28073
4
Separate Wallplate from
New Thermostat
Wallplate
Mount the new wallplate using the included screws
and anchors.
5
Mount Wallplate
MCR28094
Drill 3/32-in. holes for plaster
Drill 3/16-in. holes for drywall
MCR27518
Simply match wire labels.
Remove metal jumper if you have both
R
and
Rc
wires.
MCR28070
W2
Y2
C
G
Y
W
RC
R
LABELED WIRES
SCREW
CONVENTIONAL
INSERT WIRES
THEN TIGHTEN SCREWS
WIRE HOLE
Y
G
R
W
CONVENTIONAL
6
Connect Wires
Labels don’t match?
See Wiring Notes (over).
Have a Heat Pump system?
See Wiring Notes (over).
Call 1-800-468-1502 for wiring assistance.
Install two AA alkaline batteries and remove tab.
MCR28101
Back of thermostat
Remove tab.
7
Install Batteries
M27519
Install thermostat onto the wallplate on the wall.
Turn the power back on to the heating/cooling system.
8
Install Thermostat onto Wallplate
9
Turn Power Back
ON
If your system type is:
q
Single Stage Heat and Cool
Congratulations, you’re done!
Thermostat is set with energy saving schedule; see operating
manual to adjust schedule.
If your system type is:
q
Multistage Heat and Cool
q
Heat Pump* without Backup Heat
q
Heat Pump* with Backup Heat
q
Heat Only
q
Cool Only
Continue to step 12a to match your thermostat to your
system type.
*Heat Pump—an air conditioner that provides cooling in the
summer, and also runs in reverse in the winter to provide
heating.
This thermostat works on 24 volt or 750 mV systems. It will
NOT work on 120/240 Volt systems.
11
If your system type is...
10
Set Time and Date
Press
s
or
t
to set month, then press NEXT.
Press
s
or
t
to set day, then press NEXT.
Press
s
or
t
to set year, then press DONE.
Press
s
or
t
to set time, then press DONE to save and
exit.
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
® U.S. Registered Trademark.
© 2012 Honeywell International Inc.
69-2722—01
M.S.
05-12
Printed in U.S.A.
Automation and Control Solutions
MERCURY NOTICE:
Do not place your old
thermostat in the trash if it contains mercury in a
sealed tube. Contact the Thermostat Recycling
Corporation at www.thermostat-recycle.org or 800-
238-8192 for information on how and where to
properly and safely dispose of your old thermostat.
CAUTION:
To avoid possible compressor damage,
do not run air conditioner if the outside temperature
drops below 50°F (10°C).
This thermostat contains a Lithium battery which
may contain Perchlorate material.
Perchlorate Material—special handling may apply,
See www.dtsc.ca.gov/hazardouswaste/perchlorate
NOTE:
Jumper wire used on old thermostat? If yes, note
what letters the jumper connected and review in wiring
section.
Month
Year
Day
or
or
69-2722-01
Quick Start Guide
Programmable Thermostat
RTH7400/RTH7500 Series
MCR33843
Done
10:10
If you are not sure of your system type or if you have
other questions, call us toll-free at 1-800-468-1502.