Hotpoint RGA724EKWH Use and Care Manual / Warranty - Page 28
Flexible Connector, Rigid Pipe Hookup, Hookup, Recommended Gas And Electric Supply Location
UPC - 084691131717
View all Hotpoint RGA724EKWH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Installation Instructions RECOMMENDED GAS AND ELECTRIC SUPPLY LOCATION NOTE: Recommended gas hook-up locations behind range. Gas fittings and shut-off cock should NOT protrude more than 2″ from the wall to allow the range to fit against the wall. C D A 13″ 1/4″ Max 18″ Min. 30″ Min. 30″ Check local codes before making connections. 12″ 14″ 8″ 3″ 8″ 8″ 8″ 36″ Models 20″ Wide 24″ Wide Electrical Connection Area A 203⁄8″ 243⁄8″ B Minimum distance to walls above the cooktop on each side B C D 2″ 2″ 21⁄2″ 2″ 3″ 51⁄2″ 5″ 2″ 2″ Gas Hookup Area A FLEXIBLE CONNECTOR HOOKUP (Example) Pressure regulator Adapter 1/2″ or 3/4″ Gas pipe Installer: Inform the consumer of the location of the gas shut-off valve. Gas Flow into Range Gas Flow into Range RIGID PIPE HOOKUP (Example) Flex connector (41⁄2 ft. max.) Adapter Gas shut-off valve Pressure regulator Black iron pipe 41⁄2" 90° Elbow Nipple (may not be needed) 90° Elbow Black iron pipe Union Nipple 1/2″ or 3/4″ Gas pipe Gas shut-off valve Installer: Inform the consumer of the location of the gas shut-off valve. 28